SN54ACT04_15 [TI]

HEX INVERTERS;
SN54ACT04_15
型号: SN54ACT04_15
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

HEX INVERTERS

文件: 总5页 (文件大小:79K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SN54ACT04, SN74ACT04  
HEX INVERTERS  
SCAS518A – JULY 1995 – REVISED APRIL 1996  
SN54ACT04 . . . J OR W PACKAGE  
SN74ACT04 . . . D, DB, N, OR PW PACKAGE  
(TOP VIEW)  
Inputs Are TTL-Voltage Compatible  
EPIC (Enhanced-Performance Implanted  
CMOS) 1-µm Process  
Package Options Include Plastic  
1A  
1Y  
2A  
2Y  
3A  
V
CC  
1
2
3
4
5
6
7
14  
13  
12  
11  
10  
9
Small-Outline (D), Shrink Small-Outline  
(DB), Thin Shrink Small-Outline (PW), DIP  
(N) Packages, Ceramic Chip Carriers (FK),  
Flat (W), and DIP (J) Packages  
6A  
6Y  
5A  
5Y  
4A  
4Y  
3Y  
GND  
description  
8
The ‘ACT04 contain six independent inverters.  
The devices perform the Boolean function Y = A.  
SN54ACT04 . . . FK PACKAGE  
(TOP VIEW)  
The SN54ACT04 is characterized for operation  
over the full military temperature range of 55°C  
to 125°C. The SN74ACT04 is characterized for  
operation from 40°C to 85°C.  
3
2
1
20 19  
18  
2A  
NC  
2Y  
6Y  
NC  
5A  
NC  
5Y  
4
5
6
7
8
FUNCTION TABLE  
(each inverter)  
17  
16  
15  
14  
NC  
3A  
INPUT  
A
OUTPUT  
Y
9 10 11 12 13  
H
L
L
H
NC – No internal connection  
logic symbol  
logic diagram, each inverter (positive logic)  
1
1A  
3
2
4
1
1Y  
2Y  
3Y  
4Y  
5Y  
6Y  
A
Y
2A  
5
6
3A  
9
8
4A  
11  
10  
12  
5A  
13  
6A  
This symbol is in accordance with ANSI/IEEE Std 91-1984 and  
IEC Publication 617-12.  
Pin numbers shown are for the D, DB, J, N, PW, and W packages.  
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of  
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.  
EPIC is a trademark of Texas Instruments Incorporated.  
Copyright 1996, Texas Instruments Incorporated  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of Texas Instruments  
standard warranty. Production processing does not necessarily include  
testing of all parameters.  
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ACT04, SN74ACT04  
HEX INVERTERS  
SCAS518A – JULY 1995 – REVISED APRIL 1996  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V  
CC  
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to V  
+ 0.5 V  
+ 0.5 V  
I
CC  
CC  
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to V  
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA  
IK  
I
I
CC  
Output clamp current, I  
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA  
OK  
O O CC  
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
Continuous current through V  
Maximum power dissipation at T = 55°C (in still air) (see Note 2): D package . . . . . . . . . . . . . . . . . . 1.25 W  
O
O
CC  
CC  
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±200 mA  
A
DB package . . . . . . . . . . . . . . . . . 0.5 W  
N package . . . . . . . . . . . . . . . . . . . 1.1 W  
PW package . . . . . . . . . . . . . . . . . 0.5 W  
Storage temperature range, T  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
stg  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.  
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils,  
except for the N package, which has a trace length of zero.  
recommended operating conditions (see Note 3)  
SN54ACT04  
SN74ACT04  
UNIT  
MIN  
4.5  
2
MAX  
MIN  
4.5  
2
MAX  
V
V
V
V
V
Supply voltage  
5.5  
5.5  
V
V
CC  
IH  
IL  
High-level input voltage  
Low-level input voltage  
Input voltage  
0.8  
0.8  
V
0
0
V
V
0
0
V
V
V
I
CC  
CC  
Output voltage  
V
O
CC  
CC  
I
I
High-level output current  
Low-level output current  
Input transition rise or fall rate  
Operating free-air temperature  
– 24  
24  
– 24  
24  
8
mA  
mA  
ns/V  
°C  
OH  
OL  
t/v  
0
8
0
T
55  
125  
40  
85  
A
NOTE 3: Unused inputs must be held high or low to prevent them from floating.  
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ACT04, SN74ACT04  
HEX INVERTERS  
SCAS518A – JULY 1995 – REVISED APRIL 1996  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
T
A
= 25°C  
TYP  
SN54ACT04  
SN74ACT04  
PARAMETER  
TEST CONDITIONS  
V
UNIT  
CC  
MIN  
4.4  
MAX  
MIN  
4.4  
MAX  
MIN  
4.4  
MAX  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
5.5 V  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
4.49  
I
I
= – 50 µA  
OH  
5.4  
5.49  
5.4  
5.4  
3.86  
4.86  
3.7  
3.76  
4.76  
V
OH  
V
= – 24 mA  
= – 50 mA  
OL  
4.7  
I
I
3.85  
OH  
= 75 mA  
3.85  
OH  
0.001  
0.001  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
I
= 50 µA  
OL  
OL  
0.36  
0.36  
0.5  
0.44  
0.44  
V
OL  
I
= 24 mA  
V
0.5  
I
I
= 50 mA  
1.65  
OL  
= 75 mA  
1.65  
±1  
OL  
I
I
V = V  
or GND  
or GND,  
±0.1  
±1  
µA  
µA  
I
I
CC  
CC  
V = V  
I = 0  
O
2
40  
20  
CC  
I
One input at 3.4 V,  
Other inputs at GND or V  
I  
CC  
5.5 V  
5 V  
0.6  
4.5  
1.6  
1.5  
mA  
pF  
CC  
C
V = V  
or GND  
CC  
i
I
Not more than one output should be tested at a time, and the duration of the test should not exceed 2 ms.  
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V  
.
CC  
switching characteristics over recommended operating free-air temperature range,  
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)  
V
CC  
T
A
= 25°C  
TYP  
6
SN54ACT04  
SN74ACT04  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
MIN  
1
MAX  
8.5  
8
MIN  
1
MAX  
9
MIN  
1
MAX  
9
t
t
PLH  
A
Y
ns  
1
5.5  
1
8.5  
1
8.5  
PHL  
operating characteristics, V  
= 5 V, T = 25°C  
A
CC  
PARAMETER  
Power dissipation capacitance  
TEST CONDITIONS  
= 50 pF, f = 1 MHz  
L
TYP  
UNIT  
C
C
45  
pF  
pd  
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ACT04, SN74ACT04  
HEX INVERTERS  
SCAS518A – JULY 1995 – REVISED APRIL 1996  
PARAMETER MEASUREMENT INFORMATION  
3 V  
0 V  
TEST  
/t  
S1  
Input  
(see Note B)  
1.5 V  
1.5 V  
t
Open  
PLH PHL  
t
t
t
PHL  
PLH  
PHL  
2 × V  
CC  
V
OH  
In-Phase  
Output  
S1  
50% V  
CC  
50% V  
50% V  
500 Ω  
Open  
CC  
From Output  
Under Test  
V
OL  
t
PLH  
C
= 50 pF  
L
500 Ω  
V
OH  
(see Note A)  
Out-of-Phase  
Output  
50% V  
CC  
CC  
V
OL  
LOAD CIRCUIT  
VOLTAGE WAVEFORMS  
NOTES: A.  
C includes probe and jig capacitance.  
L
B. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, Z = 50 , t 2.5 ns, t 2.5 ns.  
O
r
f
C. The outputs are measured one at a time with one input transition per measurement.  
Figure 1. Load Circuit and Voltage Waveforms  
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
IMPORTANT NOTICE  
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue  
any product or service without notice, and advise customers to obtain the latest version of relevant information  
to verify, before placing orders, that information being relied on is current and complete. All products are sold  
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those  
pertaining to warranty, patent infringement, and limitation of liability.  
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in  
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent  
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily  
performed, except those mandated by government requirements.  
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF  
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL  
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR  
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER  
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO  
BE FULLY AT THE CUSTOMER’S RISK.  
In order to minimize risks associated with the customer’s applications, adequate design and operating  
safeguards must be provided by the customer to minimize inherent or procedural hazards.  
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent  
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other  
intellectual property right of TI covering or relating to any combination, machine, or process in which such  
semiconductor products or services might be or are used. TI’s publication of information regarding any third  
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.  
Copyright 1998, Texas Instruments Incorporated  

相关型号:

SN54ACT08

QUADRUPLE 2-INPUT POSITIVE-AND GATES
TI

SN54ACT08FK

QUADRUPLE 2-INPUT POSITIVE-AND GATES
TI

SN54ACT08J

QUADRUPLE 2-INPUT POSITIVE-AND GATES
TI

SN54ACT08W

QUADRUPLE 2-INPUT POSITIVE-AND GATES
TI

SN54ACT08_03

QUADROPLE 2-INPUT POSITIVE - AND GATES
TI

SN54ACT08_06

QUADRUPLE 2-INPUT POSITIVE-AND GATES
TI

SN54ACT08_08

QUADRUPLE 2-INPUT POSITIVE-AND GATES
TI

SN54ACT08_10

QUADRUPLE 2-INPUT POSITIVE-AND GATES
TI

SN54ACT10

TRIPLE 3-INPUT POSITIVE-NAND GATES
TI

SN54ACT10FK

TRIPLE 3-INPUT POSITIVE-NAND GATES
TI

SN54ACT10J

TRIPLE 3-INPUT POSITIVE-NAND GATES
TI

SN54ACT10W

TRIPLE 3-INPUT POSITIVE-NAND GATES
TI