SN54ALS137AJ [TI]

3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS WITH ADDRESS LATCHES; 3线路至8线路解码器与地址锁存器​​/多路解复用器
SN54ALS137AJ
型号: SN54ALS137AJ
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS WITH ADDRESS LATCHES
3线路至8线路解码器与地址锁存器​​/多路解复用器

解码器 解复用器 锁存器 双倍数据速率
文件: 总15页 (文件大小:516K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SN54ALS137A, SN74ALS137A, SN74AS137  
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS  
WITH ADDRESS LATCHES  
SDAS203C – APRIL 1982 – REVISED JANUARY 1995  
SN54ALS137A . . . J PACKAGE  
SN74ALS137A, SN74AS137 . . . D OR N PACKAGE  
(TOP VIEW)  
Combines Decoder and 3-Bit Address  
Latch  
Incorporates Two Output Enables to  
Simplify Cascading  
A
B
V
CC  
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
Package Options Include Plastic Small-  
Outline (D) Packages, Ceramic Chip  
Carriers (FK), and Standard Plastic (N) and  
Ceramic (J) 300-mil DIPs  
Y0  
Y1  
Y2  
Y3  
Y4  
Y5  
Y6  
C
LE  
G2  
G1  
Y7  
description  
GND  
The SN54ALS137A, SN74ALS137A, and  
SN74AS137 are 3-line to 8-line decoders/  
demultiplexers with latches on the three address  
inputs. When the latch-enable (LE) input is low,  
the devices act as decoders/demultiplexers.  
When LE goes from low to high, the address  
present at the select (A, B, and C) inputs is stored  
in the latches. Further address changes are  
ignored as long as LE remains high. The  
output-enable controls (G1 and G2) control the  
outputs independently of the select or  
latch-enable inputs. All of the outputs are forced  
high if G1 is low or G2 is high. These devices are  
ideally suited for implementing glitch-free  
decoders in strobed (stored-address) applications  
in bus-oriented systems.  
SN54ALS137A . . . FK PACKAGE  
(TOP VIEW)  
3
2
1
20 19  
18 Y1  
C
LE  
4
5
6
7
8
17  
16  
15  
14  
Y2  
NC  
Y3  
Y4  
NC  
G2  
G1  
9 10 11 12 13  
NC – No internal connection  
The SN54ALS137A is characterized for operation  
over the full military temperature range of 55°C  
to 125°C. The SN74ALS137A and SN74AS137  
are characterized for operation from 0°C to 70°C.  
FUNCTION TABLE  
INPUTS  
OUTPUTS  
ENABLE  
SELECT  
LE  
X
X
L
G1  
X
G2  
C
X
X
L
B
X
X
L
A
X
X
L
Y0  
H
H
L
Y1  
H
H
H
L
Y2  
H
H
H
H
L
Y3  
H
H
H
H
H
L
Y4  
H
H
H
H
H
H
L
Y5  
H
H
H
H
H
H
H
L
Y6  
H
H
H
H
H
H
H
H
L
Y7  
H
X
L
L
L
L
L
L
L
L
L
H
H
H
H
H
H
H
H
H
L
L
H
H
H
H
H
H
H
H
H
L
L
L
H
L
H
H
H
H
H
H
H
L
L
H
H
L
H
H
H
H
H
H
L
L
H
L
H
H
H
H
H
L
H
H
H
H
X
H
H
H
H
L
L
H
L
H
H
H
L
H
H
X
H
H
L
H
X
H
H
Outputs corresponding to stored address = L; all others = H  
Copyright 1995, Texas Instruments Incorporated  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of Texas Instruments  
standard warranty. Production processing does not necessarily include  
testing of all parameters.  
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS137A, SN74ALS137A, SN74AS137  
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS  
WITH ADDRESS LATCHES  
SDAS203C – APRIL 1982 – REVISED JANUARY 1995  
logic symbols (alternatives)  
X/Y  
DMUX  
4
4
15  
14  
13  
12  
11  
10  
9
15  
14  
13  
12  
11  
10  
9
C8  
8D  
C8  
8D  
0
1
2
3
4
5
6
7
Y0  
Y1  
Y2  
Y3  
Y4  
Y5  
Y6  
Y7  
0
1
2
3
4
5
6
7
Y0  
Y1  
Y2  
Y3  
Y4  
Y5  
Y6  
Y7  
LE  
LE  
1
1
2
3
A
B
C
A
B
C
1
0
2
3
0
7
G
2
4
2
6
6
5
&
&
G1  
G2  
G1  
G2  
5
EN  
7
7
These symbols are in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.  
Pin numbers shown are for the D, J, and N packages.  
logic diagram (positive logic)  
15  
1
Y0  
Y1  
Y2  
A
14  
13  
2
Select  
Inputs  
B
12  
11  
Y3  
Y4  
Data  
Outputs  
3
4
C
10  
9
Y5  
Y6  
Y7  
Latch  
Enable  
LE  
7
5
6
G2  
G1  
Output  
Enables  
Pin numbers shown are for the D, J, and N packages.  
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS137A, SN74ALS137A, SN74AS137  
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS  
WITH ADDRESS LATCHES  
SDAS203C – APRIL 1982 – REVISED JANUARY 1995  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
CC  
Input voltage, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
I
Operating free-air temperature range, T : SN54ALS137A . . . . . . . . . . . . . . . . . . . . . . . . . . . 55°C to 125°C  
A
SN74ALS137A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
recommended operating conditions  
SN54ALS137A  
MIN NOM MAX  
SN74ALS137A  
MIN NOM MAX  
UNIT  
V
V
V
Supply voltage  
4.5  
2
5
5.5  
4.5  
2
5
5.5  
V
V
CC  
High-level input voltage  
IH  
Low-level input voltage  
0.7  
0.4  
4
0.8  
0.4  
8
V
IL  
I
I
t
t
t
High-level output current  
Low-level output current  
Pulse duration, LE low  
mA  
mA  
ns  
ns  
ns  
°C  
OH  
OL  
w
15  
15  
10  
10  
5
Setup time at A, B, and C before LE↑  
Hold time at A, B, and C after LE↑  
Operating free-air temperature  
su  
h
5
T
A
55  
125  
0
70  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
SN54ALS137A  
SN74ALS137A  
PARAMETER  
TEST CONDITIONS  
UNIT  
MIN TYP  
MAX  
MIN TYP  
MAX  
V
V
V
V
= 4.5 V,  
I = 18 mA  
1.5  
1.5  
V
V
IK  
CC  
I
= 4.5 V to 5.5 V,  
I
I
I
= 0.4 mA  
= 4 mA  
V
CC  
–2  
V
CC  
–2  
OH  
CC  
OH  
OL  
OL  
0.25  
0.4  
0.25  
0.35  
0.4  
0.5  
V
OL  
V
CC  
= 4.5 V  
V
= 8 mA  
I
I
I
I
I
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
= 5.5 V,  
= 5.5 V,  
= 5.5 V,  
= 5.5 V,  
= 5.5 V  
V = 7 V  
0.1  
20  
0.1  
mA  
µA  
I
I
V = 2.7 V  
I
20  
IH  
IL  
V = 0.4 V  
I
0.1  
112  
11  
0.1  
112  
11  
mA  
mA  
mA  
§
V
O
= 2.25 V  
20  
30  
O
5
5
CC  
§
All typical values are at V  
= 5 V, T = 25°C.  
A
CC  
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I  
.
OS  
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS137A, SN74ALS137A, SN74AS137  
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS  
WITH ADDRESS LATCHES  
SDAS203C – APRIL 1982 – REVISED JANUARY 1995  
switching characteristics (see Figure 1)  
V
C
R
= 4.5 V to 5.5 V,  
= 50 pF,  
CC  
L
L
= 500 ,  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
T
A
= MIN to MAX  
SN54ALS137A SN74ALS137A  
MIN  
5
MAX  
25  
MIN  
5
MAX  
20  
t
t
t
t
t
t
t
t
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
A, B, C  
Y
Y
Y
Y
ns  
ns  
ns  
ns  
6
25  
6
20  
4
15  
3
12  
G2  
G1  
5
18  
4
15  
5
21  
4
17  
5
19  
4
15  
7
27  
6
22  
LE  
7
25  
7
20  
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
CC  
Input voltage, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V  
I
Operating free-air temperature range, T : SN74AS137 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C  
A
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
recommended operating conditions  
SN74AS137  
MIN NOM  
UNIT  
MAX  
V
V
V
Supply voltage  
4.5  
2
5
5.5  
V
V
CC  
High-level input voltage  
IH  
Low-level input voltage  
0.8  
–2  
20  
V
IL  
I
I
t
t
t
High-level output current  
Low-level output current  
Pulse duration, LE low  
mA  
mA  
ns  
ns  
ns  
°C  
OH  
OL  
w
6.5  
4
Setup time at A, B, and C before LE↑  
Hold time at A, B, and C after LE↑  
Operating free-air temperature  
su  
h
1
T
A
0
70  
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS137A, SN74ALS137A, SN74AS137  
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS  
WITH ADDRESS LATCHES  
SDAS203C – APRIL 1982 – REVISED JANUARY 1995  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
SN74AS137  
PARAMETER  
TEST CONDITIONS  
UNIT  
MIN TYP  
MAX  
V
V
V
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
= 4.5 V,  
I = 18 mA  
1.2  
V
IK  
I
= 4.5 V to 5.5 V,  
= 4.5 V,  
I
= 2 mA  
= 20 mA  
V 2  
CC  
V
OH  
OL  
OH  
OL  
I
0.35  
0.5  
0.1  
V
I
I
I
I
I
= 5.5 V,  
V = 7 V  
I
mA  
µA  
mA  
mA  
mA  
I
= 5.5 V,  
V = 2.7 V  
I
20  
IH  
IL  
= 5.5 V,  
V = 0.4 V  
I
–1  
= 5.5 V,  
V
O
= 2.25 V  
30  
– 112  
24  
O
= 5.5 V  
15  
CC  
All typical values are at V  
= 5 V, T = 25°C.  
A
CC  
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I  
.
OS  
switching characteristics (see Figure 1)  
V
C
R
= 4.5 V to 5.5 V,  
= 50 pF,  
CC  
L
L
= 500 ,  
FROM  
TO  
(OUTPUT)  
§
PARAMETER  
(INPUT)  
UNIT  
T
A
= MIN to MAX  
SN74AS137  
MIN  
2
MAX  
12.5  
12.5  
8
t
t
t
t
t
t
t
t
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
A, B, C  
Y
Y
Y
Y
ns  
ns  
ns  
ns  
2
2
G2  
G1  
2
8.5  
10  
2
2
9
3
13.5  
14  
LE  
3
§
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.  
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ALS137A, SN74ALS137A, SN74AS137  
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS  
WITH ADDRESS LATCHES  
SDAS203C – APRIL 1982 – REVISED JANUARY 1995  
PARAMETER MEASUREMENT INFORMATION  
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES  
7 V  
R
= R1 = R2  
V
CC  
L
S1  
R1  
R
L
Test  
Point  
From Output  
Under Test  
From Output  
Under Test  
Test  
Point  
Test  
Point  
From Output  
Under Test  
C
C
L
R
L
R2  
L
C
L
(see Note A)  
(see Note A)  
(see Note A)  
LOAD CIRCUIT FOR  
BI-STATE  
TOTEM-POLE OUTPUTS  
LOAD CIRCUIT  
FOR OPEN-COLLECTOR OUTPUTS  
LOAD CIRCUIT  
FOR 3-STATE OUTPUTS  
3.5 V  
3.5 V  
Timing  
Input  
High-Level  
1.3 V  
1.3 V  
1.3 V  
Pulse  
0.3 V  
0.3 V  
t
h
t
w
t
su  
3.5 V  
3.5 V  
0.3 V  
Data  
Input  
Low-Level  
1.3 V  
1.3 V  
1.3 V  
1.3 V  
Pulse  
0.3 V  
VOLTAGE WAVEFORMS  
SETUP AND HOLD TIMES  
VOLTAGE WAVEFORMS  
PULSE DURATIONS  
3.5 V  
0.3 V  
Output  
Control  
(low-level  
enabling)  
1.3 V  
1.3 V  
3.5 V  
t
PZL  
Input  
1.3 V  
1.3 V  
t
PLZ  
0.3 V  
PHL  
3.5 V  
t
Waveform 1  
S1 Closed  
(see Note B)  
t
PLH  
1.3 V  
V
OH  
In-Phase  
Output  
1.3 V  
1.3 V  
1.3 V  
V
OL  
0.3 V  
V
OL  
t
PHZ  
t
PLH  
t
PZH  
t
PHL  
V
OH  
V
Waveform 2  
S1 Open  
(see Note B)  
OH  
OL  
Out-of-Phase  
Output  
(see Note C)  
1.3 V  
1.3 V  
0.3 V  
V
0 V  
VOLTAGE WAVEFORMS  
PROPAGATION DELAY TIMES  
VOLTAGE WAVEFORMS  
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS  
NOTES: A.  
C includes probe and jig capacitance.  
L
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.  
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.  
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.  
D. All input pulses have the following characteristics: PRR 1 MHz, t = t = 2 ns, duty cycle = 50%.  
r
f
E. The outputs are measured one at a time with one transition per measurement.  
Figure 1. Load Circuits and Voltage Waveforms  
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
PACKAGE OPTION ADDENDUM  
www.ti.com  
26-Sep-2005  
PACKAGING INFORMATION  
Orderable Device  
Status (1)  
Package Package  
Pins Package Eco Plan (2) Lead/Ball Finish MSL Peak Temp (3)  
Qty  
Type  
LCCC  
CDIP  
CFP  
Drawing  
5962-9066501M2A  
5962-9066501MEA  
5962-9066501MFA  
SN74ALS137AD  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
FK  
J
20  
16  
16  
16  
1
1
1
TBD  
TBD  
TBD  
Call TI  
Call TI  
Call TI  
Level-NC-NC-NC  
Level-NC-NC-NC  
Level-NC-NC-NC  
W
D
SOIC  
40 Green (RoHS & CU NIPDAU Level-1-260C-UNLIM  
no Sb/Br)  
SN74ALS137ADE4  
SN74ALS137ADR  
SN74ALS137ADRE4  
SN74ALS137AN  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
SOIC  
SOIC  
SOIC  
PDIP  
PDIP  
SO  
D
D
16  
16  
16  
16  
16  
16  
16  
40 Green (RoHS & CU NIPDAU Level-1-260C-UNLIM  
no Sb/Br)  
2500 Green (RoHS & CU NIPDAU Level-1-260C-UNLIM  
no Sb/Br)  
D
2500 Green (RoHS & CU NIPDAU Level-1-260C-UNLIM  
no Sb/Br)  
N
25  
Pb-Free  
(RoHS)  
CU NIPDAU Level-NC-NC-NC  
SN74ALS137ANE4  
SN74ALS137ANSR  
SN74ALS137ANSRE4  
N
25  
Pb-Free  
(RoHS)  
CU NIPDAU Level-NC-NC-NC  
NS  
NS  
2000 Green (RoHS & CU NIPDAU Level-1-260C-UNLIM  
no Sb/Br)  
SO  
2000 Green (RoHS & CU NIPDAU Level-1-260C-UNLIM  
no Sb/Br)  
SN74AS137D  
SN74AS137DR  
SN74AS137N  
OBSOLETE  
OBSOLETE  
OBSOLETE  
ACTIVE  
SOIC  
SOIC  
PDIP  
LCCC  
CDIP  
CFP  
D
D
16  
16  
16  
20  
16  
16  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
Call TI  
N
Call TI  
SNJ54ALS137AFK  
SNJ54ALS137AJ  
SNJ54ALS137AW  
FK  
J
1
1
1
Level-NC-NC-NC  
Level-NC-NC-NC  
Level-NC-NC-NC  
ACTIVE  
ACTIVE  
W
(1) The marketing status values are defined as follows:  
ACTIVE: Product device recommended for new designs.  
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.  
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in  
a new design.  
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.  
OBSOLETE: TI has discontinued the production of the device.  
(2)  
Eco Plan  
-
The planned eco-friendly classification: Pb-Free (RoHS) or Green (RoHS  
&
no Sb/Br)  
-
please check  
http://www.ti.com/productcontent for the latest availability information and additional product content details.  
TBD: The Pb-Free/Green conversion plan has not been defined.  
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements  
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered  
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.  
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame  
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)  
(3)  
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder  
temperature.  
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is  
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the  
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take  
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on  
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited  
information may not be available for release.  
Addendum-Page 1  
PACKAGE OPTION ADDENDUM  
www.ti.com  
26-Sep-2005  
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI  
to Customer on an annual basis.  
Addendum-Page 2  
MECHANICAL DATA  
MLCC006B – OCTOBER 1996  
FK (S-CQCC-N**)  
LEADLESS CERAMIC CHIP CARRIER  
28 TERMINAL SHOWN  
A
B
NO. OF  
TERMINALS  
**  
18 17 16 15 14 13 12  
MIN  
MAX  
MIN  
MAX  
0.342  
(8,69)  
0.358  
(9,09)  
0.307  
(7,80)  
0.358  
(9,09)  
19  
20  
11  
10  
9
20  
28  
44  
52  
68  
84  
0.442  
(11,23)  
0.458  
(11,63)  
0.406  
(10,31)  
0.458  
(11,63)  
21  
B SQ  
22  
0.640  
(16,26)  
0.660  
(16,76)  
0.495  
(12,58)  
0.560  
(14,22)  
8
A SQ  
23  
0.739  
(18,78)  
0.761  
(19,32)  
0.495  
(12,58)  
0.560  
(14,22)  
7
24  
25  
6
0.938  
(23,83)  
0.962  
(24,43)  
0.850  
(21,6)  
0.858  
(21,8)  
5
1.141  
(28,99)  
1.165  
(29,59)  
1.047  
(26,6)  
1.063  
(27,0)  
26 27 28  
1
2
3
4
0.080 (2,03)  
0.064 (1,63)  
0.020 (0,51)  
0.010 (0,25)  
0.020 (0,51)  
0.010 (0,25)  
0.055 (1,40)  
0.045 (1,14)  
0.045 (1,14)  
0.035 (0,89)  
0.045 (1,14)  
0.035 (0,89)  
0.028 (0,71)  
0.022 (0,54)  
0.050 (1,27)  
4040140/D 10/96  
NOTES: A. All linear dimensions are in inches (millimeters).  
B. This drawing is subject to change without notice.  
C. This package can be hermetically sealed with a metal lid.  
D. The terminals are gold plated.  
E. Falls within JEDEC MS-004  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
IMPORTANT NOTICE  
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,  
enhancements, improvements, and other changes to its products and services at any time and to discontinue  
any product or service without notice. Customers should obtain the latest relevant information before placing  
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms  
and conditions of sale supplied at the time of order acknowledgment.  
TI warrants performance of its hardware products to the specifications applicable at the time of sale in  
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI  
deems necessary to support this warranty. Except where mandated by government requirements, testing of all  
parameters of each product is not necessarily performed.  
TI assumes no liability for applications assistance or customer product design. Customers are responsible for  
their products and applications using TI components. To minimize the risks associated with customer products  
and applications, customers should provide adequate design and operating safeguards.  
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,  
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process  
in which TI products or services are used. Information published by TI regarding third-party products or services  
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.  
Use of such information may require a license from a third party under the patents or other intellectual property  
of the third party, or a license from TI under the patents or other intellectual property of TI.  
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without  
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction  
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for  
such altered documentation.  
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that  
product or service voids all express and any implied warranties for the associated TI product or service and  
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.  
Following are URLs where you can obtain information on other Texas Instruments products and application  
solutions:  
Products  
Applications  
Audio  
Amplifiers  
amplifier.ti.com  
www.ti.com/audio  
Data Converters  
dataconverter.ti.com  
Automotive  
www.ti.com/automotive  
DSP  
dsp.ti.com  
Broadband  
Digital Control  
Military  
www.ti.com/broadband  
www.ti.com/digitalcontrol  
www.ti.com/military  
Interface  
Logic  
interface.ti.com  
logic.ti.com  
Power Mgmt  
Microcontrollers  
power.ti.com  
Optical Networking  
Security  
www.ti.com/opticalnetwork  
www.ti.com/security  
www.ti.com/telephony  
www.ti.com/video  
microcontroller.ti.com  
Telephony  
Video & Imaging  
Wireless  
www.ti.com/wireless  
Mailing Address:  
Texas Instruments  
Post Office Box 655303 Dallas, Texas 75265  
Copyright 2005, Texas Instruments Incorporated  

相关型号:

SN54ALS137FH

暂无描述
TI

SN54ALS137FH-00

ALS SERIES, OTHER DECODER/DRIVER, INVERTED OUTPUT, CQCC20
TI

SN54ALS138A

3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
TI

SN54ALS138AFK

3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
TI

SN54ALS138AJ

3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
TI

SN54ALS138A_07

3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
TI

SN54ALS138A_08

3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
TI

SN54ALS138A_14

3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
TI

SN54ALS138FH

Decoder/Driver
TI

SN54ALS138FH-00

ALS SERIES, OTHER DECODER/DRIVER, INVERTED OUTPUT, CQCC20
TI

SN54ALS139

DUAL 2-LINE TO 4-LINE DECODERS/DEMULTIPLEXERS
TI

SN54ALS139FH

IC,DECODER/DEMUX,2-TO-4-LINE,ALS-TTL,LLCC,20PIN,CERAMIC
TI