SN74ALS29823NT3 [TI]
ALS SERIES, 9-BIT DRIVER, TRUE OUTPUT, PDIP24;型号: | SN74ALS29823NT3 |
厂家: | TEXAS INSTRUMENTS |
描述: | ALS SERIES, 9-BIT DRIVER, TRUE OUTPUT, PDIP24 驱动 光电二极管 输出元件 逻辑集成电路 触发器 |
文件: | 总12页 (文件大小:264K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SN54ALS29823, SN74ALS29823
9-BIT BUS-INTERFACE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SDAS146B – JANUARY 1986 – REVISED JANUARY 1995
SN54ALS29823 . . . JT PACKAGE
SN74ALS29823 . . . DW OR NT PACKAGE
(TOP VIEW)
• Functionally Equivalent to AMD’s AM29823
• Provide Extra Data Width Necessary for
Wider Address/Data Paths or Buses With
Parity
OE
1D
2D
3D
4D
5D
6D
7D
8D
V
CC
1
2
3
4
5
6
7
8
9
24
• Outputs Have Undershoot-Protection
23 1Q
22 2Q
21 3Q
20 4Q
19 5Q
18 6Q
17 7Q
16 8Q
15 9Q
14 CLKEN
13 CLK
Circuitry
• Power-Up High-Impedance State
• Buffered Control Inputs Reduce dc Loading
Effects
• Package Options Include Plastic
Small-Outline (DW) Packages and Standard
Plastic (NT) and Ceramic (JT) 300-mil DIPs
9D 10
CLR 11
GND 12
description
These 9-bit flip-flops feature 3-state outputs
designed specifically for driving highly capacitive
or relatively low-impedance loads. They are particularly suitable for implementing wider buffer registers, I/O
ports, bidirectional bus drivers, parity bus interfacing, and working registers.
With the clock-enable (CLKEN) input low, the nine D-type edge-triggered flip-flops enter data on the low-to-high
transitions of the clock (CLK) input. Taking CLKEN high disables the clock buffer, latching the outputs. The
′ALS29823 have noninverting data (D) inputs. Taking the clear (CLR) input low causes the nine Q outputs to
go low independently of the clock.
Abufferedoutput-enable(OE)inputplacesthenineoutputsineitheranormallogicstate(highorlowlogiclevels)
or a high-impedance state. The outputs also are in the high-impedance state during power-up and power-down
conditions. The outputs remain in the high-impedance state while the device is powered down. In the
high-impedance state, the outputs neither load nor drive the bus lines significantly. The high-impedance state
and increased drive provide the capability to drive bus lines without interface or pullup components.
OE does not affect the internal operation of the flip-flops. Old data can be retained or new data can be entered
while the outputs are in the high-impedance state.
The SN54ALS29823 is characterized for operation over the full military temperature range of –55°C to 125°C.
The SN74ALS29823 is characterized for operation from 0°C to 70°C.
FUNCTION TABLE
(each flip-flop)
INPUTS
OUTPUT
Q
OE
L
CLR CLKEN CLK
D
X
H
L
L
H
H
H
X
X
L
X
↑
L
H
L
L
L
L
↑
L
H
X
X
X
X
X
Q
0
H
Z
Copyright 1995, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN54ALS29823, SN74ALS29823
9-BIT BUS-INTERFACE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SDAS146B – JANUARY 1986 – REVISED JANUARY 1995
†
logic symbol
1
EN
OE
11
R
CLR
14
G1
CLKEN
13
CLK
1C2
2
23
22
21
20
19
18
17
16
15
1D
2D
1Q
2Q
3Q
4Q
5Q
6Q
7Q
8Q
9Q
3
2D
4
3D
5
4D
6
5D
7
6D
8
7D
9
8D
10
9D
†
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
logic diagram (positive logic)
1
OE
11
CLR
14
CLKEN
R
13
CLK
23
C1
1D
1Q
2
1D
To Eight Other Channels
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN54ALS29823, SN74ALS29823
9-BIT BUS-INTERFACE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SDAS146B – JANUARY 1986 – REVISED JANUARY 1995
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
CC
Input voltage, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
I
Voltage applied to a disabled high-impedance output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range, T : SN54ALS29823 . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to 125°C
A
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS29823
MIN NOM MAX
UNIT
V
V
V
Supply voltage
4.5
2
5
5.5
V
V
CC
High-level input voltage
Low-level input voltage
High-level output current
Low-level output current
IH
0.8
–18
32
V
IL
I
I
mA
mA
OH
OL
CLR low
7
8
t
w
t
su
t
h
Pulse duration
ns
CLK high or low
CLR inactive
Data
7
4
ns
Setup time before CLK↑
CLKEN high or low
CLKEN
8
2
ns
Hold time after CLK↑
Data
4
T
A
Operating free-air temperature
–55
25
125
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
SN54ALS29823
PARAMETER
UNIT
V
TEST CONDITIONS
‡
MIN TYP
MAX
V
V
V
V
V
= 4.5 V,
I = –18 mA
I
–1.2
IK
CC
I
I
I
= –12 mA
= –18 mA
= 32 mA
= 2.4 V
2.4
2
3.3
OH
OH
OL
= 4.5 V
V
OH
CC
V
CC
V
CC
V
CC
V
CC
V
CC
V
CC
V
CC
= 4.5 V,
= 5.5 V,
= 5.5 V,
= 5.5 V,
= 5.5 V,
= 5.5 V,
= 5.5 V,
0.25
0.5
50
V
OL
OZH
OZL
I
I
I
I
I
I
I
V
µA
µA
mA
µA
mA
mA
O
O
V
= 0.4 V
–50
0.1
V = 5.5 V
I
V = 2.7 V
20
IH
I
V = 0.4 V
–0.5
–250
90
IL
I
§
V
= 0
–75
OS
O
Outputs high
Outputs low
Outputs open
I
V
CC
= 5.5 V
105
115
mA
CC
‡
§
All typical values are at V
= 5 V, T = 25°C.
A
CC
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN54ALS29823, SN74ALS29823
9-BIT BUS-INTERFACE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SDAS146B – JANUARY 1986 – REVISED JANUARY 1995
switching characteristics (see Figure 1)
†
V
T
A
= MIN to MAX ,
CC
= MIN to MAX
†
FROM
TO
(OUTPUT)
PARAMETER
(INPUT)
TEST CONDITIONS
UNIT
SN54ALS29823
MIN
2
MAX
11.5
11.5
21
t
t
t
t
t
t
t
t
t
t
t
t
t
PLH
PHL
PLH
PHL
PHL
PZH
PZL
PZH
PZL
PHZ
PLZ
PHZ
PLZ
CLK
ns
Any Q
C
= 50 pF
L
2
2
CLK
CLR
OE
ns
ns
ns
Any Q
Any Q
C
= 300 pF
= 50 pF
L
2
21
C
C
1
17.5
17
L
L
1
Any Q
Any Q
Any Q
Any Q
= 50 pF
= 300 pF
= 50 pF
1
17
1
25
ns
ns
ns
OE
OE
OE
C
L
1
29.5
16
1
C
L
1
14
1
12
C
= 5 pF
L
1
11
†
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
CC
Input voltage, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
I
Voltage applied to a disabled 3-state output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range, T : SN74ALS29823 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
A
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74ALS29823
MIN NOM MAX
UNIT
V
V
V
Supply voltage
4.75
2
5
5.25
V
V
CC
High-level input voltage
Low-level input voltage
High-level output current
Low-level output current
IH
0.8
–24
48
V
IL
I
mA
mA
OH
OL
I
CLR low
5
5
5
2
6
0
2
0
t
t
t
Pulse duration
ns
w
su
h
CLK high or low
CLR inactive
Data
ns
Setup time before CLK↑
CLKEN high or low
CLKEN
ns
Hold time after CLK↑
Data
T
Operating free-air temperature
25
70
°C
A
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN54ALS29823, SN74ALS29823
9-BIT BUS-INTERFACE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SDAS146B – JANUARY 1986 – REVISED JANUARY 1995
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
SN74ALS29823
PARAMETER
UNIT
V
TEST CONDITIONS
†
MIN TYP
MAX
V
V
V
V
V
= 4.75 V,
I = –18 mA
I
–1.2
IK
CC
I
I
I
= –15 mA
= –24 mA
= 48 mA
= 2.4 V
2.4
2
3.3
3.1
OH
OH
OL
= 4.75 V
V
OH
CC
V
CC
V
CC
V
CC
V
CC
V
CC
V
CC
V
CC
V
CC
= 4.75 V,
= 5.25 V,
= 5.25 V,
= 5.25 V,
= 5.25 V,
= 5.25 V,
= 5.25 V,
= 5.25 V,
0.35
0.5
20
V
OL
OZH
OZL
I
I
I
I
I
I
I
I
V
V
µA
µA
mA
µA
mA
mA
mA
O
O
= 0.4 V
–20
0.1
V = 5.5 V
I
V = 2.7 V
20
IH
I
V = 0.4 V
–0.2
–250
115
IL
I
‡
V
= 0
–75
OS
O
Outputs open
80
CC
†
‡
All typical values are at V
= 5 V, T = 25°C.
A
CC
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
switching characteristics (see Figure 1)
§
V
T
A
= MIN to MAX ,
CC
= MIN to MAX
§
FROM
TO
(OUTPUT)
PARAMETER
(INPUT)
TEST CONDITIONS
UNIT
SN74ALS29823
MIN
2
MAX
10
10
16
16
12
14
14
20
23
14
12
9
t
t
t
t
t
t
t
t
t
t
t
t
t
PLH
PHL
PLH
PHL
PHL
PZH
PZL
PZH
PZL
PHZ
PLZ
PHZ
PLZ
CLK
ns
Any Q
C
= 50 pF
L
2
CLK
CLR
OE
ns
ns
ns
Any Q
Any Q
C
= 300 pF
= 50 pF
L
C
C
L
L
Any Q
Any Q
Any Q
Any Q
= 50 pF
= 300 pF
= 50 pF
ns
ns
ns
OE
OE
OE
C
L
C
L
C
= 5 pF
L
9
§
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN54ALS29823, SN74ALS29823
9-BIT BUS-INTERFACE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SDAS146B – JANUARY 1986 – REVISED JANUARY 1995
PARAMETER MEASUREMENT INFORMATION
Test Point
V
CC
SWITCH POSITION TABLE
S1
From Output
Under Test
TEST
S1
S2
R
= 180 Ω
L
t
t
Closed
Closed
Open
Closed
Closed
Closed
Closed
Closed
Closed
Open
Closed
Closed
PLH
PHL
PZH
All Diodes
1N916 or 1N3064
R1
1 kΩ
C
L
t
t
(see Note A)
t
PZL
PHZ
S2
t
PLZ
LOAD CIRCUIT
1.5 V
3 V
0
High-Level
Pulse
3 V
1.5 V
1.5 V
1.5 V
Timing Input
0
t
w
t
h
t
su
3 V
0
3 V
0
Low-Level
Pulse
1.5 V
1.5 V
Data Input
1.5 V
VOLTAGE WAVEFORMS
PULSE DURATIONS
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
3 V
0
Output
Control
1.5 V
1.5 V
t
PZL
t
PLZ
≈ 4.5 V
≈ 1.5 V
3 V
Input
1.5 V
1.5 V
Waveform 1
(see Note B)
0
1.5 V
t
PHL
t
V
OL
PLH
V
OH
OL
0.5 V
t
In-Phase
Output
PHZ
1.5 V
1.5 V
1.5 V
t
t
PZH
V
V
OH
PLH
t
PHL
Waveform 2
(see Note B)
0.5 V
V
OH
1.5 V
≈ 1.5 V
Out-of-Phase
Output
1.5 V
≈ 0
V
OL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A.
C
L
includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, Z = 50 Ω, t ≤ 2.5 ns, t ≤ 2.5 ns.
O
r
f
Figure 1. Load Circuit and Voltage Waveforms
6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
25-Sep-2013
PACKAGING INFORMATION
Orderable Device
Status Package Type Package Pins Package
Eco Plan Lead/Ball Finish
MSL Peak Temp
Op Temp (°C)
Device Marking
Samples
Drawing
Qty
(1)
(2)
(3)
(4/5)
5962-9067501MLA
ACTIVE
CDIP
JT
24
1
TBD
A42
N / A for Pkg Type
-55 to 125
5962-9067501ML
A
SNJ54ALS29823J
T
SN74ALS29823DW
SN74ALS29823DWR
SN74ALS29823NT
SNJ54ALS29823JT
OBSOLETE
OBSOLETE
OBSOLETE
ACTIVE
SOIC
SOIC
PDIP
CDIP
DW
DW
NT
JT
24
24
24
24
TBD
TBD
TBD
TBD
Call TI
Call TI
Call TI
A42
Call TI
Call TI
0 to 70
0 to 70
Call TI
0 to 70
1
N / A for Pkg Type
-55 to 125
5962-9067501ML
A
SNJ54ALS29823J
T
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com
25-Sep-2013
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
OTHER QUALIFIED VERSIONS OF SN54ALS29823, SN74ALS29823 :
Catalog: SN74ALS29823
•
Military: SN54ALS29823
•
NOTE: Qualified Version Definitions:
Catalog - TI's standard catalog product
•
Military - QML certified for Military and Defense Applications
•
Addendum-Page 2
MECHANICAL DATA
MCER004A – JANUARY 1995 – REVISED JANUARY 1997
JT (R-GDIP-T**)
CERAMIC DUAL-IN-LINE
24 LEADS SHOWN
PINS **
A
24
28
DIM
13
24
1.280
(32,51) (37,08)
1.460
A MAX
1.240
(31,50) (36,58)
1.440
B
A MIN
B MAX
B MIN
0.300
(7,62)
0.291
(7,39)
1
12
0.070 (1,78)
0.030 (0,76)
0.245
(6,22)
0.285
(7,24)
0.320 (8,13)
0.290 (7,37)
0.015 (0,38) MIN
0.100 (2,54) MAX
0.200 (5,08) MAX
Seating Plane
0.130 (3,30) MIN
0.023 (0,58)
0.015 (0,38)
0°–15°
0.014 (0,36)
0.008 (0,20)
0.100 (2,54)
4040110/C 08/96
NOTES: A. All linear dimensions are in inches (millimeters).
B. This drawing is subject to change without notice.
C. This package can be hermetically sealed with a ceramic lid using glass frit.
D. Index point is provided on cap for terminal identification.
E. Falls within MIL STD 1835 GDIP3-T24, GDIP4-T28, and JEDEC MO-058 AA, MO-058 AB
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
Automotive and Transportation www.ti.com/automotive
Communications and Telecom www.ti.com/communications
Amplifiers
Data Converters
DLP® Products
DSP
Computers and Peripherals
Consumer Electronics
Energy and Lighting
Industrial
www.ti.com/computers
www.ti.com/consumer-apps
www.ti.com/energy
dsp.ti.com
Clocks and Timers
Interface
www.ti.com/clocks
interface.ti.com
logic.ti.com
www.ti.com/industrial
www.ti.com/medical
Medical
Logic
Security
www.ti.com/security
Power Mgmt
Microcontrollers
RFID
power.ti.com
Space, Avionics and Defense
Video and Imaging
www.ti.com/space-avionics-defense
www.ti.com/video
microcontroller.ti.com
www.ti-rfid.com
www.ti.com/omap
OMAP Applications Processors
Wireless Connectivity
TI E2E Community
e2e.ti.com
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated
相关型号:
©2020 ICPDF网 联系我们和版权申明