SN74AS623FN-00 [TI]
AS SERIES, 8-BIT TRANSCEIVER, TRUE OUTPUT, PQCC20;型号: | SN74AS623FN-00 |
厂家: | TEXAS INSTRUMENTS |
描述: | AS SERIES, 8-BIT TRANSCEIVER, TRUE OUTPUT, PQCC20 输出元件 逻辑集成电路 |
文件: | 总19页 (文件大小:719K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SN74ALS620A, SN74ALS621A, SN74ALS623A, SN74AS623
OCTAL BUS TRANSCEIVERS
SDAS226A – DECEMBER 1982 – REVISED JANUARY 1995
DW OR N PACKAGE
(TOP VIEW)
• Local Bus-Latch Capability
• Choice of True or Inverting Logic
• Package Options Include Plastic
Small-Outline (DW) Packages and Standard
Plastic (N) 300-mil DIPs
OEAB
A1
V
CC
OEBA
1
2
3
4
5
6
7
8
9
10
20
19
18
17
16
15
14
A2
A3
A4
A5
A6
A7
A8
GND
B1
B2
B3
B4
DEVICE
SN74ALS620A
OUTPUT
3 state
LOGIC
Inverting
True
B5
SN74ALS621A
Open collector
3 state
13 B6
12 B7
SN74ALS623A, SN74AS623
True
11
B8
description
These octal bus transceivers are designed for asynchronous two-way communication between data buses. The
control-function implementation allows for maximum flexibility in timing.
These devices allow data transmission from the A bus to the B bus or from the B bus to the A bus, depending
upon the logic levels at the output-enable (OEAB and OEBA) inputs.
The output-enable inputs disable the device so that the buses are effectively isolated. The dual-enable
configuration gives the transceivers the capability to store data by simultaneously enabling OEAB and OEBA.
Each output reinforces its input in this transceiver configuration. When both OEAB and OEBA are enabled and
all other data sources to the two sets of bus lines are in the high-impedance state, both sets of bus lines (16 total)
remain at their last states. The 8-bit codes appearing on the two sets of buses are identical for the
SN74ALS621A, SN74ALS623A, and SN74AS623 or complementary for the SN74ALS620A.
The -1 versions of the SN74ALS620A and SN74ALS621A are identical to the standard versions, except that
the recommended maximum I is increased to 48 mA in the -1 versions.
OL
The SN74ALS620A, SN74ALS621A, SN74ALS623A, and SN74AS623 are characterized for operation from
0°C to 70°C.
FUNCTION TABLE
INPUTS
OPERATION
SN74ALS621A
OEAB
SN74ALS620A
SN74ALS623A
SN74AS623
OEBA
L
H
H
L
H
L
B data to A bus
A data to B bus
Isolation
B data to A bus
A data to B bus
Isolation
B data to A bus,
A data to B bus
B data to A bus,
A data to B bus
L
H
Copyright 1995, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN74ALS620A, SN74ALS621A, SN74ALS623A, SN74AS623
OCTAL BUS TRANSCEIVERS
SDAS226A – DECEMBER 1982 – REVISED JANUARY 1995
†
logic symbols
SN74ALS620A
19
EN1
OEBA
OEAB
1
EN2
2
18
17
16
15
14
13
12
11
A1
A2
A3
A4
A5
A6
A7
A8
B1
B2
B3
B4
B5
B6
B7
B8
1
2
3
4
5
6
7
8
9
SN74ALS623A, SN74AS623
SN74ALS621A
19
1
19
1
EN1
EN2
EN1
EN2
OEBA
OEAB
OEBA
OEAB
2
18
17
2
18
A1
B1
A1
B1
1
1
2
2
17
16
15
3
4
3
4
B2
B3
B4
B2
A2
A3
A2
A3
16
15
B3
B4
5
6
5
6
A4
A5
A4
A5
14
13
12
14
13
12
B5
B6
B7
B5
B6
B7
7
7
8
9
A6
A6
A7
A8
8
9
A7
A8
11
11
B8
B8
†
These symbols are in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN74ALS620A, SN74ALS621A, SN74ALS623A, SN74AS623
OCTAL BUS TRANSCEIVERS
SDAS226A – DECEMBER 1982 – REVISED JANUARY 1995
logic diagrams (positive logic)
SN74ALS620A
SN74ALS621A
19
19
OEBA
OEBA
1
1
OEAB
OEAB
18
B1
18
2
2
A1
A1
B1
To Seven Other Transceivers
To Seven Other Transceivers
SN74ALS623A, SN74AS623
19
1
OEBA
OEAB
2
18
A1
B1
To Seven Other Transceivers
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
CC
Input voltage, V : All inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
I
I/O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range, T : SN74ALS620A, SN74ALS623A . . . . . . . . . . . . . . . . . 0°C to 70°C
A
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN74ALS620A, SN74ALS621A, SN74ALS623A, SN74AS623
OCTAL BUS TRANSCEIVERS
SDAS226A – DECEMBER 1982 – REVISED JANUARY 1995
recommended operating conditions
SN74ALS620A
SN74ALS623A
UNIT
MIN NOM
MAX
V
V
V
Supply voltage
4.5
2
5
5.5
V
V
CC
High-level input voltage
Low-level input voltage
High-level output current
Low-level output current
Operating free-air temperature
IH
0.8
–15
24
V
IL
I
I
mA
mA
°C
OH
OL
T
A
0
70
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
SN74ALS620A
SN74ALS623A
PARAMETER
TEST CONDITIONS
UNIT
†
MIN TYP
MAX
V
V
V
V
= 4.5 V,
I = –18 mA
–1.2
V
IK
CC
I
= 4.5 V to 5.5 V,
I
I
I
I
I
= –0.4 mA
= –3 mA
= –15 mA
= 12 mA
V
–2
CC
OH
OH
OH
OL
OL
CC
2.4
3.2
V
OH
V
CC
V
CC
V
CC
V
CC
= 4.5 V
2
0.25
0.35
0.4
0.5
0.1
0.1
20
V
OL
= 4.5 V
= 5.5 V
= 5.5 V,
V
‡
= 24 mA
Control inputs
A or B ports
V = 7 V
I
I
I
mA
µA
I
V = 5.5 V
I
Control inputs
V = 2.7 V
I
IH
IL
§
A or B ports
20
Control inputs
–0.1
–0.1
–112
34
I
I
V
V
= 5.5 V,
= 5.5 V,
V = 0.4 V
I
mA
mA
CC
§
A or B ports
¶
V
O
= 2.25 V
–30
O
CC
Outputs high
Outputs low
24
31
33
32
39
42
SN74ALS620A
SN74ALS623A
V
= 5.5 V
= 5.5 V
44
CC
CC
Outputs disabled
Outputs high
Outputs low
47
I
mA
CC
43
V
50
Outputs disabled
55
†
All typical values are at V
= 5 V, T = 25°C.
A
CC
Applies only to the -1 version and only if V
‡
§
¶
is between 4.75 V and 5.25 V
CC
For I/O ports, the parameters I and I include the off-state output current.
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I
IH IL
.
OS
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN74ALS620A, SN74ALS621A, SN74ALS623A, SN74AS623
OCTAL BUS TRANSCEIVERS
SDAS226A – DECEMBER 1982 – REVISED JANUARY 1995
switching characteristics (see Figure 1)
V
C
= 4.5 V to 5.5 V,
= 50 pF,
CC
L
R1 = 500 Ω,
R2 = 500 Ω,
T
A
FROM
TO
(OUTPUT)
PARAMETER
(INPUT)
UNIT
†
= MIN to MAX
SN74ALS620A SN74ALS623A
MIN
2
MAX
10
10
10
10
17
25
12
18
18
25
12
18
MIN
2
MAX
13
11
t
t
t
t
t
t
t
t
t
t
t
t
PLH
PHL
PLH
PHL
PZH
PZL
PHZ
PLZ
PZH
PZL
PHZ
PLZ
A
B
ns
ns
ns
ns
ns
ns
B
A
A
A
B
B
2
3
2
2
13
11
2
3
3
5
22
22
16
19
22
22
16
19
OEBA
OEBA
OEAB
OEAB
5
5
2
2
3
2
3
5
5
5
2
2
3
2
†
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
CC
Input voltage, V : All inputs and I/O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
I
Operating free-air temperature range, T : SN74ALS621A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
A
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74ALS621A
MIN NOM MAX
UNIT
V
V
V
V
Supply voltage
4.5
2
5
5.5
V
V
CC
High-level input voltage
Low-level input voltage
High-level output voltage
IH
0.8
5.5
24
V
IL
V
OH
mA
mA
°C
I
Low-level output current
OL
§
48
70
T
A
Operating free-air temperature
0
§
Applies only to the -1 version and only if V
CC
is between 4.75 V and 5.25 V
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN74ALS620A, SN74ALS621A, SN74ALS623A, SN74AS623
OCTAL BUS TRANSCEIVERS
SDAS226A – DECEMBER 1982 – REVISED JANUARY 1995
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
SN74ALS621A
PARAMETER
TEST CONDITIONS
UNIT
†
MIN TYP
MAX
–1.5
0.1
0.5
0.5
0.1
0.1
20
V
IK
V
V
= 4.5 V,
I = –18 mA
I
V
CC
I
= 4.5 V,
V
OH
= 5.5 V
mA
OH
CC
I
I
= 24 mA
= 48 mA
0.35
0.35
OL
V
OL
V
CC
V
CC
V
CC
V
CC
V
CC
= 4.5 V
V
‡
OL
Control inputs
A or B ports
V = 7 V
I
I
I
I
I
= 5.5 V
= 5.5 V,
= 5.5 V,
= 5.5 V
mA
µA
I
V = 5.5 V
I
Control inputs
V = 2.7 V
I
IH
IL
§
A or B ports
Control inputs
20
–0.1
–0.1
40
V = 0.4 V
I
mA
mA
§
A or B ports
Outputs high
Outputs low
29
35
CC
48
†
‡
§
All typical values are at V
= 5 V, T = 25°C.
A
CC
Applies only to the -1 version and only if V
is between 4.75 V and 5.25 V
CC
For I/O ports, the parameters I and I include the off-state output current.
IH IL
switching characteristics (see Figure 1)
V
C
R
= 4.5 V to 5.5 V,
= 50 pF,
CC
L
L
= 680 Ω,
FROM
TO
(OUTPUT)
¶
PARAMETER
(INPUT)
UNIT
T
A
= MIN to MAX
SN74ALS621A
MIN
10
5
MAX
33
t
t
t
t
t
t
t
t
PLH
PHL
PLH
PHL
PLH
PHL
PLH
PHL
A
B
ns
ns
ns
ns
B
A
A
B
20
10
5
33
20
10
12
10
12
39
OEBA
OEAB
35
39
35
¶
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN74ALS620A, SN74ALS621A, SN74ALS623A, SN74AS623
OCTAL BUS TRANSCEIVERS
SDAS226A – DECEMBER 1982 – REVISED JANUARY 1995
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
CC
Input voltage, V : All inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
I
I/O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range, T : SN74AS623 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
A
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74AS623
MIN NOM
UNIT
MAX
V
V
V
Supply voltage
4.5
2
5
5.5
V
V
CC
High-level input voltage
Low-level input voltage
High-level output current
Low-level output current
Operating free-air temperature
IH
0.8
–15
64
V
IL
I
I
mA
mA
°C
OH
OL
T
A
0
70
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
SN74AS623
PARAMETER
TEST CONDITIONS
UNIT
‡
MIN TYP
MAX
V
V
V
V
V
= 4.5 V,
I = –18 mA
–1.2
V
IK
CC
I
= 4.5 V to 5.5 V,
I
I
I
I
= –2 mA
= –3 mA
= –15 mA
= 64 mA
V
–2
CC
OH
OH
OH
OL
CC
2.4
3.2
V
OH
OL
V
CC
V
CC
V
CC
= 4.5 V
2
= 4.5 V,
0.35
0.55
0.1
V
Control inputs
A or B ports
V = 7 V
I
I
I
= 5.5 V
mA
V = 5.5 V
I
0.1
Control inputs
20
I
V
= 5.5 V,
V = 2.7 V
µA
IH
IL
CC
I
§
A or B ports
70
Control inputs
–0.5
–0.75
–150
93
I
I
V
V
= 5.5 V,
= 5.5 V,
V = 0.4 V
I
mA
mA
CC
§
A or B ports
¶
V
O
= 2.25 V
–30
O
CC
Outputs high
Outputs low
57
16
71
I
V
CC
= 5.5 V
189
116
mA
CC
Outputs disabled
‡
§
¶
All typical values are at V
= 5 V, T = 25°C.
A
CC
For I/O ports, the parameters I and I include the off-state output current.
IH
IL
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I
.
OS
7
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN74ALS620A, SN74ALS621A, SN74ALS623A, SN74AS623
OCTAL BUS TRANSCEIVERS
SDAS226A – DECEMBER 1982 – REVISED JANUARY 1995
switching characteristics (see Figure 1)
V
C
= 4.5 V to 5.5 V,
= 50 pF,
CC
L
R1 = 500 Ω,
R2 = 500 Ω,
FROM
(INPUT)
TO
(OUTPUT)
PARAMETER
UNIT
†
T
= MIN to MAX
A
SN74AS623
MIN
1
MAX
t
t
t
t
t
t
t
t
t
t
t
t
9
8
PLH
PHL
PLH
PHL
PZH
PZL
PHZ
PLZ
PZH
PZL
PHZ
PLZ
A
B
ns
ns
ns
ns
ns
ns
B
A
A
A
B
B
1
1
9
1
8.5
11
2
OEBA
OEBA
OEAB
OEAB
2
10
7.5
11.5
11.5
11
1
1
2
2
1
7
1
9
†
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
8
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN74ALS620A, SN74ALS621A, SN74ALS623A, SN74AS623
OCTAL BUS TRANSCEIVERS
SDAS226A – DECEMBER 1982 – REVISED JANUARY 1995
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
7 V
R
= R1 = R2
V
CC
L
S1
R1
R
L
Test
Point
From Output
Under Test
From Output
Under Test
Test
Point
Test
Point
From Output
Under Test
C
C
L
R
L
R2
L
C
L
(see Note A)
(see Note A)
(see Note A)
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
3.5 V
3.5 V
Timing
Input
High-Level
1.3 V
1.3 V
1.3 V
Pulse
0.3 V
0.3 V
t
h
t
w
t
su
3.5 V
3.5 V
0.3 V
Data
Input
Low-Level
1.3 V
1.3 V
1.3 V
1.3 V
Pulse
0.3 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
3.5 V
0.3 V
Output
Control
(low-level
enabling)
1.3 V
1.3 V
3.5 V
t
PZL
Input
1.3 V
1.3 V
t
PLZ
0.3 V
PHL
3.5 V
t
Waveform 1
S1 Closed
(see Note B)
t
PLH
1.3 V
V
OH
In-Phase
Output
1.3 V
1.3 V
1.3 V
V
OL
0.3 V
V
OL
t
PHZ
t
PLH
t
PZH
t
PHL
V
OH
V
Waveform 2
S1 Open
(see Note B)
OH
OL
Out-of-Phase
Output
(see Note C)
1.3 V
1.3 V
0.3 V
V
0 V
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A.
C includes probe and jig capacitance.
L
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.
D. All input pulses have the following characteristics: PRR ≤ 1 MHz, t = t = 2 ns, duty cycle = 50%.
r
f
E. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuits and Voltage Waveforms
9
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
26-Aug-2013
PACKAGING INFORMATION
Orderable Device
SN74ALS620ADW
SN74ALS620ADWE4
SN74ALS620ADWG4
Status Package Type Package Pins Package
Eco Plan Lead/Ball Finish
MSL Peak Temp
Op Temp (°C)
0 to 70
Device Marking
Samples
Drawing
Qty
(1)
(2)
(3)
(4/5)
ACTIVE
SOIC
SOIC
SOIC
DW
20
20
20
25
Green (RoHS
& no Sb/Br)
CU NIPDAU
CU NIPDAU
CU NIPDAU
Level-1-260C-UNLIM
Level-1-260C-UNLIM
Level-1-260C-UNLIM
ALS620A
ACTIVE
ACTIVE
DW
DW
25
25
Green (RoHS
& no Sb/Br)
0 to 70
ALS620A
ALS620A
Green (RoHS
& no Sb/Br)
0 to 70
SN74ALS620ADWR
SN74ALS620AN
OBSOLETE
ACTIVE
SOIC
PDIP
DW
N
20
20
TBD
Call TI
Call TI
0 to 70
0 to 70
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
SN74ALS620AN
SN74ALS620AN
SN74ALS620ANE4
ACTIVE
PDIP
N
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
0 to 70
SN74ALS621A-1DWE4
SN74ALS621A-1DWG4
SN74ALS621A-1N
ACTIVE
ACTIVE
ACTIVE
SOIC
SOIC
PDIP
DW
DW
N
20
20
20
TBD
Call TI
Call TI
Call TI
Call TI
0 to 70
0 to 70
0 to 70
ALS621A-1
TBD
ALS621A-1
20
20
25
25
25
20
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
SN74ALS621A-1N
SN74ALS621A-1NE4
SN74ALS621ADW
SN74ALS621ADWE4
SN74ALS621ADWG4
SN74ALS621AN
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
PDIP
SOIC
SOIC
SOIC
PDIP
PDIP
N
DW
DW
DW
N
20
20
20
20
20
20
Pb-Free
(RoHS)
CU NIPDAU
CU NIPDAU
CU NIPDAU
CU NIPDAU
CU NIPDAU
CU NIPDAU
N / A for Pkg Type
Level-1-260C-UNLIM
Level-1-260C-UNLIM
Level-1-260C-UNLIM
N / A for Pkg Type
N / A for Pkg Type
0 to 70
0 to 70
0 to 70
0 to 70
0 to 70
0 to 70
SN74ALS621A-1N
ALS621A
Green (RoHS
& no Sb/Br)
Green (RoHS
& no Sb/Br)
ALS621A
Green (RoHS
& no Sb/Br)
ALS621A
Pb-Free
(RoHS)
SN74ALS621AN
SN74ALS621AN
SN74ALS621ANE4
N
Pb-Free
(RoHS)
SN74ALS623A-1DW
SN74ALS623A-1DWR
SN74ALS623A-1N
SN74ALS623ADW
OBSOLETE
OBSOLETE
OBSOLETE
ACTIVE
SOIC
SOIC
PDIP
SOIC
DW
DW
N
20
20
20
20
TBD
TBD
TBD
Call TI
Call TI
Call TI
Call TI
0 to 70
0 to 70
0 to 70
0 to 70
Call TI
Call TI
DW
25
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
ALS623A
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com
26-Aug-2013
Orderable Device
Status Package Type Package Pins Package
Eco Plan Lead/Ball Finish
MSL Peak Temp
Op Temp (°C)
0 to 70
Device Marking
Samples
Drawing
Qty
(1)
(2)
(3)
(4/5)
SN74ALS623ADWE4
SN74ALS623ADWG4
SN74ALS623AN
ACTIVE
SOIC
SOIC
PDIP
DW
20
20
20
25
Green (RoHS
& no Sb/Br)
CU NIPDAU
CU NIPDAU
CU NIPDAU
Level-1-260C-UNLIM
Level-1-260C-UNLIM
N / A for Pkg Type
ALS623A
ACTIVE
ACTIVE
DW
N
25
20
Green (RoHS
& no Sb/Br)
0 to 70
ALS623A
Pb-Free
(RoHS)
0 to 70
SN74ALS623AN
SN74ALS623AN3
SN74ALS623ANE4
OBSOLETE
ACTIVE
PDIP
PDIP
N
N
20
20
TBD
Call TI
Call TI
0 to 70
0 to 70
20
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
SN74ALS623AN
ALS623A
SN74ALS623ANSR
SN74ALS623ANSRE4
SN74ALS623ANSRG4
ACTIVE
ACTIVE
ACTIVE
SO
SO
SO
NS
NS
NS
20
20
20
2000
2000
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
CU NIPDAU
CU NIPDAU
Level-1-260C-UNLIM
Level-1-260C-UNLIM
Level-1-260C-UNLIM
0 to 70
0 to 70
0 to 70
Green (RoHS
& no Sb/Br)
ALS623A
Green (RoHS
& no Sb/Br)
ALS623A
SN74AS623DW
SN74AS623DWR
SN74AS623N
OBSOLETE
OBSOLETE
OBSOLETE
SOIC
SOIC
PDIP
DW
DW
N
20
20
20
TBD
TBD
TBD
Call TI
Call TI
Call TI
Call TI
Call TI
Call TI
0 to 70
0 to 70
0 to 70
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Addendum-Page 2
PACKAGE OPTION ADDENDUM
www.ti.com
26-Aug-2013
(4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 3
PACKAGE MATERIALS INFORMATION
www.ti.com
14-Jul-2012
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
B0
K0
P1
W
Pin1
Diameter Width (mm) (mm) (mm) (mm) (mm) Quadrant
(mm) W1 (mm)
SN74ALS623ANSR
SO
NS
20
2000
330.0
24.4
8.2
13.0
2.5
12.0
24.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
14-Jul-2012
*All dimensions are nominal
Device
Package Type Package Drawing Pins
SO NS 20
SPQ
Length (mm) Width (mm) Height (mm)
367.0 367.0 45.0
SN74ALS623ANSR
2000
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
Automotive and Transportation www.ti.com/automotive
Communications and Telecom www.ti.com/communications
Amplifiers
Data Converters
DLP® Products
DSP
Computers and Peripherals
Consumer Electronics
Energy and Lighting
Industrial
www.ti.com/computers
www.ti.com/consumer-apps
www.ti.com/energy
dsp.ti.com
Clocks and Timers
Interface
www.ti.com/clocks
interface.ti.com
logic.ti.com
www.ti.com/industrial
www.ti.com/medical
Medical
Logic
Security
www.ti.com/security
Power Mgmt
Microcontrollers
RFID
power.ti.com
Space, Avionics and Defense
Video and Imaging
www.ti.com/space-avionics-defense
www.ti.com/video
microcontroller.ti.com
www.ti-rfid.com
www.ti.com/omap
OMAP Applications Processors
Wireless Connectivity
TI E2E Community
e2e.ti.com
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated
相关型号:
©2020 ICPDF网 联系我们和版权申明