TS5A3159-Q1_14 [TI]

1-Ω SPDT ANALOG SWITCH;
TS5A3159-Q1_14
型号: TS5A3159-Q1_14
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

1-Ω SPDT ANALOG SWITCH

光电二极管
文件: 总25页 (文件大小:919K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TS5A3159-Q1  
www.ti.com  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
1-Ω SPDT ANALOG SWITCH  
Check for Samples: TS5A3159-Q1  
1
FEATURES  
Low Charge Injection  
Excellent ON-Resistance Matching  
Low Total Harmonic Distortion  
Qualified for Automotive Applications  
AEC-Q100 Qualified with the Following  
Results:  
1.65-V to 5.5-V Single-Supply Operation  
Device Temperature Grade 1: –40°C to  
125°C Ambient Operating Temperature  
Range  
APPLICATIONS  
Cell Phones  
Device HBM ESD Classification Level H2  
Device CDM ESD Classification Level C3B  
PDAs  
Portable Instrumentation  
Specified Break-Before-Make Switching  
Low ON-State Resistance (1 Ω)  
Control Inputs are 5-V Tolerant  
DESCRIPTION  
The TS5A3159-Q1 is a single-pole double-throw (SPDT) analog switch that is designed to operate from 1.65 V to  
5.5 V. The device offers a low ON-state resistance and an excellent ON-resistance, matching with the break-  
before-make feature to prevent signal distortion during the transferring of a signal from one channel to another.  
The device has an excellent total harmonic distortion (THD) performance and consumes very low power. These  
features make this device suitable for portable audio applications.  
SOT-23 PACKAGE  
(TOP VIEW)  
TS5A3159  
NO  
GND  
NC  
1
2
3
6
5
4
IN  
V
+
COM  
Table 1. FUNCTION TABLE  
IN  
NC TO  
NO TO  
COM, COM COM, COM  
TO NC  
ON  
TO NO  
OFF  
L
H
OFF  
ON  
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of  
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of the Texas  
Instruments standard warranty. Production processing does not  
necessarily include testing of all parameters.  
Copyright © 2012, Texas Instruments Incorporated  
 
TS5A3159-Q1  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
www.ti.com  
Table 2. Summary of Characteristics  
V+ = 5 V and TA = 25°C  
2:1 Multiplexer / Demultiplexer  
(1 × SPDT)  
Configuration  
Number of channels  
1
1.3 Ω  
ON-state resistance (ron  
)
ON-state resistance match (Δron  
ON-state resistance flatness (ron(flat)  
Turn on/turn off time (tON / tOFF  
)
0.1 Ω  
)
0.15 Ω  
)
20 ns / 15 ns  
12 ns  
Break-before-make time (tBBM  
Charge injection (QC)  
Bandwidth (BW)  
)
36 pC  
100 MHz  
–65 dB at 1 MHz  
–65 dB at 1 MHz  
0.01%  
OFF isolation (OISO  
Crosstalk (XTALK  
)
)
Total harmonic distortion (THD)  
Leakage current (INO(OFF) / INC(OFF)  
Package option  
)
±6 nA  
6-pin DBV  
ORDERING INFORMATION(1)  
ORDERABLE PART NUMBER(2)  
TS5A3159QDBVRQ1  
TA  
TOP-SIDE MARKING  
–40°C to 125°C  
UAAQ  
(1) Package drawings, thermal data, and symbolization are available at www.ti.com/packaging.  
(2) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI  
web site at www.ti.com.  
ABSOLUTE MAXIMUM RATINGS(1)  
over operating free-air temperature range (unless otherwise noted)  
MIN  
–0.5  
–0.5  
MAX UNIT  
V+  
Supply voltage range(2)  
Analog voltage range(2)(3)(4)  
6.5  
V+ + 0.5  
±50  
V
V
VNO, VCOM  
II / OK  
Analog port diode current  
VNO, VCOM < 0 or VNO, VCOM > V+  
VNO, VCOM = 0 to V+  
mA  
mA  
mA  
V
INO, ICOM  
ONstate switch current  
±200  
±400  
6.5  
ONstate peak switch current(5)  
Digital input voltage range(2)(3)  
Digital input clamp current  
Continuous current through V+ or GND  
Storage temperature range  
VIN  
IIK  
0.5  
VIN < 0  
50  
mA  
mA  
°C  
kV  
V
±100  
150  
Tstg  
–65  
Human body model (HBM) AEC-Q100 classification level H2  
Charged device model (CDM) AEC-Q100 classification level C3B  
2
ESD Rating  
750  
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings  
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating  
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
(2) All voltages are with respect to ground, unless otherwise specified.  
(3) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.  
(4) This value is limited to 5.5 V maximum.  
(5) Pulse at 1 ms duration < 10% duty cycle.  
2
Submit Documentation Feedback  
Copyright © 2012, Texas Instruments Incorporated  
Product Folder Links: TS5A3159-Q1  
 
 
TS5A3159-Q1  
www.ti.com  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
THERMAL INFORMATION  
TS5A3159-Q1  
UNIT  
THERMAL METRIC(1)  
DBV (6 PINS)  
θJA  
Junction-to-ambient thermal resistance  
192.9  
133.3  
θJCtop  
θJB  
Junction-to-case (top) thermal resistance  
Junction-to-board thermal resistance  
37.6  
°C/W  
38.9  
ψJT  
Junction-to-top characterization parameter  
Junction-to-board characterization parameter  
Junction-to-case (bottom) thermal resistance  
ψJB  
37.1  
N/A  
θJCbot  
(1) For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.  
Electrical Characteristics for 5-V Supply  
V+ = 4.5 V to 5.5 V and TA = 40°C to 125°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
TA  
V+  
MIN TYP(1) MAX UNIT  
Analog Switch  
VCOM  
VNO,VNC  
,
Analog signal range  
Peak ON resistance  
0
V+  
V
25°C  
Full  
1
1.5  
1.5  
1.3  
1.3  
0 VNO or VNC V+,  
ICOM = 30 mA  
Switch ON,  
See Figure 11  
rpeak  
4.5 V  
25°C  
Full  
0.75  
VNO or VNC = 2.5 V,  
ICOM = 30 mA  
Switch ON,  
See Figure 11  
ron  
ON-state resistance  
4.5 V  
4.5 V  
ON-state resistance match  
between channels  
VNO or VNC = 2.5 V,  
ICOM = 30 mA  
Switch ON,  
See Figure 11  
ron  
25°C  
25°C  
0.1  
0 VNO or VNC V+,  
ICOM = 30 mA  
0.233  
Switch ON,  
See Figure 11  
ron(flat)  
ON-state resistance flatness  
4.5 V  
VNO or VNC = 1 V, 1.5 V,  
2.5 V,  
ICOM = 30 mA  
25°C  
0.15  
0.2  
25°C  
Full  
6  
150  
6  
6
150  
6
INC(OFF)  
,
NC, NO  
VNC or VNO = 4.5 V,  
VCOM = 0  
Switch OFF,  
See Figure 12  
5.5 V  
5.5 V  
nA  
nA  
INO(OFF)  
OFF leakage current  
25°C  
Full  
2.8  
INC(ON)  
,
NC, NO  
VNC or VNO = 4.5 V,  
VCOM = Open  
Switch ON,  
See Figure 13  
INO(ON)  
ON leakage current  
150  
8  
150  
8
VNC or VNO = 4.5 V or  
Open,  
VCOM = 4.5 V  
25°C  
0.47  
COM  
ON leakage current  
Switch ON,  
See Figure 13  
ICOM(ON)  
5.5 V  
nA  
Full  
150  
150  
Digital Inputs (IN)  
VIH  
Input logic high  
Full  
Full  
Full  
2.4  
0
5.5  
0.8  
1
V
V
VIL  
Input logic low  
IIH, IIL  
Dynamic  
Input leakage current  
VIN = 5.5 V or 0  
5.5 V  
1  
µA  
25°C  
Full  
4.5 V  
to 5.5  
V
20  
15  
35  
40  
20  
35  
VCOM = V+,  
RL = 50 Ω,  
CL = 35 pF,  
See Figure 15  
tON  
Turn-on time  
ns  
ns  
ns  
25°C  
Full  
4.5 V  
to 5.5  
V
VCOM = V+,  
RL = 50 Ω,  
CL = 35 pF,  
See Figure 15  
tOFF  
Turn-off time  
25°C  
Full  
4.5 V  
to 5.5  
V
1
1
12 14.5  
VNC = VNO = V+ / 2,  
RL = 50 Ω,  
CL = 35 pF,  
See Figure 16  
tBBM  
Break-before-make time  
QC  
CNC(OFF)  
CNO(OFF) OFF capacitance  
Charge injection  
NC, NO  
CL = 1 nF, VGEN = 0 V,  
See Figure 20  
See Figure 14  
25°C  
5 V  
36  
23  
pC  
pF  
,
VNC or VNO = V+ or GND,  
Switch OFF,  
25°C  
5 V  
(1) TA = 25°C  
Copyright © 2012, Texas Instruments Incorporated  
Submit Documentation Feedback  
3
Product Folder Links: TS5A3159-Q1  
 
 
 
 
TS5A3159-Q1  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
www.ti.com  
Electrical Characteristics for 5-V Supply (continued)  
V+ = 4.5 V to 5.5 V and TA = 40°C to 125°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
TA  
V+  
MIN TYP(1) MAX UNIT  
CNC(ON)  
,
NC, NO  
ON capacitance  
VNC or VNO = V+ or GND,  
Switch ON,  
See Figure 14  
25°C  
5 V  
84  
pF  
CNO(ON)  
CCOM(ON)  
CIN  
COM  
ON capacitance  
VCOM = V+ or GND,  
Switch ON,  
See Figure 14  
See Figure 14  
See Figure 17  
25°C  
25°C  
25°C  
5 V  
5 V  
5 V  
84  
2.1  
pF  
pF  
Digital input capacitance  
VIN = V+ or GND,  
RL = 50 Ω,  
Switch ON,  
BW  
Bandwidth  
100  
MHz  
RL = 50 Ω,  
f = 1 MHz,  
Switch OFF,  
See Figure 18  
OISO  
OFF isolation  
Crosstalk  
25°C  
25°C  
5 V  
5 V  
–65  
–65  
dB  
dB  
RL = 50 Ω,  
f = 1 MHz,  
Switch ON,  
See Figure 19  
XTALK  
f = 600 Hz to 20  
kHz,  
See Figure 21  
RL = 600 Ω,  
CL = 50 pF,  
THD  
Total harmonic distortion  
Positive supply current  
25°C  
5 V  
0.01  
%
Supply  
25°C  
Full  
0.1  
0.5  
I+  
VIN = V+ or GND,  
Switch ON or OFF  
5.5 V  
µA  
Electrical Characteristics for 3.3-V Supply  
V+ = 3 V to 3.6 V and TA = 40°C to 125°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
TA  
V+  
MIN TYP(1)  
MAX UNIT  
Analog Switch  
VCOM  
VNO,VNC  
,
Analog signal range  
0
V+  
V
25°C  
Full  
1.35  
2.2  
2.2  
1.8  
1.8  
0 VNO or VNC V+,  
ICOM = 24 mA,  
Switch ON,  
See Figure 11  
rpeak  
Peak ON-state resistance  
3 V  
25°C  
Full  
1.15  
VNO or VNC = 2 V,  
ICOM = 24 mA,  
Switch ON,  
See Figure 11  
ron  
ON-state resistance  
3 V  
3 V  
ON-state resistance match  
between channels  
VNO or VNC = 2 V, 0.8 V,  
ICOM = 24 mA,  
Switch ON,  
See Figure 11  
ron  
25°C  
25°C  
25°C  
0.11  
0.225  
0.25  
0.2  
0 VNO or VNC V+,  
ICOM = 24 mA,  
Switch ON,  
See Figure 11  
ron(flat)  
ON-state resistance flatness  
3 V  
VNO or VNC = 2 V, 0.8 V,  
ICOM = 24 mA,  
INC(OFF)  
INO(OFF)  
,
NC, NO  
OFF leakage current  
VNC or VNO = 3 V,  
VCOM = 0,  
Switch OFF,  
See Figure 12  
25°C 3.6 V  
25°C 3.6 V  
25°C 3.6 V  
nA  
nA  
nA  
INC(ON)  
INO(ON)  
,
NC, NO  
ON leakage current  
VNC or VNO = 3 V,  
VCOM = Open,  
Switch ON,  
See Figure 13  
2.8  
COM  
ON leakage current  
VNC or VNO = 3 V or Open,  
VCOM = 3 V,  
Switch ON,  
See Figure 13  
ICOM(ON)  
0.47  
Digital Inputs (IN)  
VIH  
Input logic high  
Full  
2
5.5  
1
V
V
VIL  
Input logic low  
Full  
0
0.6  
IIH, IIL  
Dynamic  
Input leakage current  
VIN = 5.5 V or 0  
Full 3.6 V  
–1  
µA  
25°C  
Full  
3 V  
to  
3.6 V  
30  
20  
40  
55  
25  
40  
VCOM = V+,  
RL = 50 Ω  
CL = 35 pF,  
See Figure 15  
tON  
Turn-on time  
Turn-off time  
ns  
ns  
25°C  
Full  
3 V  
to  
3.6 V  
VCOM = V+,  
RL = 50 Ω  
CL = 35 pF,  
See Figure 15  
tOFF  
(1) TA = 25°C  
Submit Documentation Feedback  
4
Copyright © 2012, Texas Instruments Incorporated  
Product Folder Links: TS5A3159-Q1  
 
 
 
TS5A3159-Q1  
www.ti.com  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
Electrical Characteristics for 3.3-V Supply (continued)  
V+ = 3 V to 3.6 V and TA = 40°C to 125°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
TA  
V+  
MIN TYP(1)  
MAX UNIT  
25°C  
3 V  
to  
3.6 V  
1
1
21  
29  
ns  
VNC = VNO = V+ / 2,  
RL = 50 Ω  
CL = 35 pF,  
See Figure 16  
tBBM  
Break-before-make time  
Full  
QC  
Charge injection  
CL = 1 nF, VGEN = 0 V  
See Figure 20  
See Figure 14  
25°C 3.3 V  
25°C 3.3 V  
20  
23  
pC  
pF  
CNC(OFF)  
,
VNC or VNO = V+ or GND,  
Switch OFF  
NC, NO OFF capacitance  
CNO(OFF)  
CNC(ON)  
CNO(ON)  
,
VNC or VNO = V+ or GND,  
Switch ON  
NC, NO ON capacitance  
See Figure 14  
25°C 3.3 V  
84  
pF  
VCOM = V+ or GND,  
Switch ON  
CCOM(ON) COM ON capacitance  
See Figure 14  
See Figure 14  
See Figure 17  
25°C 3.3 V  
25°C 3.3 V  
25°C 3.3 V  
84  
2.1  
pF  
pF  
CIN  
Digital input capacitance  
Bandwidth  
VIN = V+ or GND  
RL = 50 Ω,  
Switch ON  
BW  
100  
MHz  
RL = 50 Ω,  
f = 1 MHz  
Switch OFF,  
See Figure 18  
OISO  
OFF isolation  
Crosstalk  
25°C 3.3 V  
25°C 3.3 V  
–65  
–65  
dB  
dB  
RL = 50 Ω,  
f = 1 MHz  
Switch ON,  
See Figure 19  
XTALK  
f = 600 Hz to 20  
kHz,  
See Figure 21  
RL = 600 Ω,  
CL = 50 pF  
THD  
Total harmonic distortion  
Positive supply current  
25°C 3.3 V  
0.015  
%
Supply  
25°C  
3.6 V  
Full  
0.1  
μA  
0.5  
Switch ON or  
OFF  
I+  
VIN = V+ or GND  
Electrical Characteristics for 2.5-V Supply  
V+ = 2.3 V to 2.7 V and TA = 40°C to 125°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
TA  
V+  
MIN TYP(1) MAX UNIT  
Analog Switch  
VCOM  
VNO,VNC  
,
Analog signal range  
0
V+  
V
25°C  
Full  
1.7  
2.9  
2.9  
2.3  
2.3  
0 VNO or VNC V+,  
ICOM = 8 mA  
Switch ON,  
See Figure 11  
rpeak  
Peak ON-state resistance  
2.5 V  
2.5 V  
25°C  
Full  
1.45  
VNO or VNC = 1.8 V,  
ICOM = 8 mA  
Switch ON,  
See Figure 11  
ron  
ON-state resistance  
ON-state resistance match  
between channels  
VNO or VNC = 0.8 V, 1.8 V, Switch ON,  
ICOM = 8 mA  
ron  
25°C 2.5 V  
0.7  
0.5  
See Figure 11  
0 VNO or VNC V+,  
ICOM = 8 mA  
25°C  
2.5 V  
25°C  
Switch ON,  
See Figure 11  
ron(flat)  
ON-state resistance flatness  
VNO or VNC = 0.8 V, 1.8 V,  
ICOM = 8 mA  
0.45  
0.2  
INC(OFF)  
INO(OFF)  
,
NC, NO  
Off leakage current  
VNC or VNO = 2.3 V,  
VCOM = 0  
Switch OFF,  
See Figure 12  
25°C 2.7 V  
25°C 2.7 V  
nA  
nA  
INC(ON)  
INO(ON)  
,
NC, NO  
On leakage current  
VNC or VNO = 2.3 V,  
VCOM = Open  
Switch ON,  
See Figure 13  
2.8  
VNC or VNO = 2.3 V or  
Open,  
VCOM = 2.3 V  
COM  
On leakage current  
Switch ON,  
See Figure 13  
ICOM(ON)  
25°C 2.7 V  
0.47  
nA  
Digital Inputs (IN)  
VIH  
Input logic high  
Full  
1.8  
0
5.5  
1
V
V
VIL  
Input logic low  
Full  
0.6  
IIH, IIL  
Input leakage current  
VIN = 5.5 V or 0  
Full 2.7 V  
1  
µA  
(1) TA = 25°C  
Copyright © 2012, Texas Instruments Incorporated  
Submit Documentation Feedback  
5
Product Folder Links: TS5A3159-Q1  
 
 
 
TS5A3159-Q1  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
www.ti.com  
Electrical Characteristics for 2.5-V Supply (continued)  
V+ = 2.3 V to 2.7 V and TA = 40°C to 125°C (unless otherwise noted)  
PARAMETER  
TEST CONDITIONS  
TA  
V+  
MIN TYP(1) MAX UNIT  
Dynamic  
25°C 2.3 V  
to  
40  
30  
33  
55  
70  
40  
55  
39  
VCOM = V+,  
RL = 50 Ω,  
CL = 35 pF,  
See Figure 15  
tON  
Turn-on time  
ns  
ns  
ns  
Full  
2.7 V  
25°C 2.3 V  
to  
VCOM = V+,  
RL = 50 Ω,  
CL = 35 pF,  
See Figure 15  
tOFF  
Turn-off time  
Full  
2.7 V  
25°C 2.3 V  
to  
1
1
VNC = VNO = V+ / 2,  
RL = 50 Ω,  
CL = 35 pF,  
See Figure 16  
tBBM  
Break-before-make time  
Full  
2.7 V  
QC  
CNC(OFF)  
CNO(OFF) OFF capacitance  
Charge injection  
NC, NO  
CL = 1 nF, VGEN = 0 V,  
See Figure 20  
See Figure 14  
25°C 2.5 V  
25°C 2.5 V  
13  
23  
pC  
pF  
,
VNC or VNO = V+ or GND,  
Switch OFF,  
CNC(ON)  
,
NC, NO  
ON capacitance  
VNC or VNO = V+ or GND,  
Switch ON,  
See Figure 14  
25°C 2.5 V  
84  
pF  
CNO(ON)  
CCOM(ON)  
CIN  
COM  
ON capacitance  
VCOM = V+ or GND,  
Switch ON,  
See Figure 14  
See Figure 14  
See Figure 17  
25°C 2.5 V  
25°C 2.5 V  
25°C 2.5 V  
84  
2.1  
pF  
pF  
Digital input capacitance  
VIN = V+ or GND,  
RL = 50 Ω,  
Switch ON,  
BW  
Bandwidth  
100  
MHz  
RL = 50 Ω,  
f = 1 MHz,  
Switch OFF,  
See Figure 18  
OISO  
OFF isolation  
Crosstalk  
25°C 2.5 V  
25°C 2.5 V  
–64  
–64  
dB  
dB  
RL = 50 Ω,  
f = 1 MHz,  
Switch ON,  
See Figure 19  
XTALK  
f = 600 Hz to 20  
kHz,  
See Figure 21  
RL = 600 Ω,  
CL = 50 pF,  
THD  
Total harmonic distortion  
Positive supply current  
25°C 2.5 V  
0.025  
%
Supply  
25°C  
2.7 V  
Full  
0.1  
0.5  
I+  
VIN = V+ or GND,  
Switch ON or OFF  
μA  
Electrical Characteristics for 1.8-V Supply  
V+ = 1.65 V to 1.95 V and TA = 40°C to 125°C (unless otherwise noted  
TYP(  
PARAMETER  
TEST CONDITIONS  
TA  
V+  
MIN  
MAX UNIT  
1)  
Analog Switch  
VCOM  
VNO,VNC  
,
Analog signal range  
Peak  
0
V+  
V
25°C  
Full  
4
5.2  
5.2  
3.5  
3.5  
0 VNO or VNC V+,  
Switch ON,  
See Figure 11  
rpeak  
1.8 V  
1.8 V  
ON-state resistance ICOM = 2 mA  
25°C  
Full  
1.7  
VNO or VNC = 1.5 V,  
ICOM = 2 mA  
Switch ON,  
See Figure 11  
ron  
ON-state resistance  
ON-state resistance  
match between  
channels  
25°C  
0.7  
0.7  
VNO or VNC = 0.6 V, 1.5 V,  
ICOM = 2 mA  
Switch ON,  
See Figure 11  
ron  
1.8 V  
1.8 V  
Full  
25°C  
Full  
1.85  
1.85  
0.9  
0 VNO or VNC V+,  
ICOM = 2 mA  
ON-state resistance  
flatness  
Switch ON,  
See Figure 11  
ron(flat)  
25°C  
Full  
VNO or VNC = 0.6 V, 1.5 V,  
ICOM = 2 mA  
0.9  
INC(OFF)  
INO(OFF)  
,
NC, NO  
Off leakage current VCOM = 0  
VNC or VNO = 1.65 V,  
Switch OFF,  
See Figure 12  
1.95  
V
25°C  
0.2  
nA  
(1) TA = 25°C  
Submit Documentation Feedback  
6
Copyright © 2012, Texas Instruments Incorporated  
Product Folder Links: TS5A3159-Q1  
 
 
 
TS5A3159-Q1  
www.ti.com  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
Electrical Characteristics for 1.8-V Supply (continued)  
V+ = 1.65 V to 1.95 V and TA = 40°C to 125°C (unless otherwise noted  
TYP(  
PARAMETER  
TEST CONDITIONS  
TA  
V+  
MIN  
MAX UNIT  
1)  
INC(ON)  
INO(ON)  
,
NC, NO  
VNC or VNO = 1.65 V, Switch ON,  
1.95  
V
25°C  
25°C  
2.8  
nA  
nA  
On leakage current VCOM = Open  
See Figure 13  
COM  
VNC or VNO = 1.65 V or Open,  
Switch ON,  
1.95  
V
ICOM(ON)  
0.47  
On leakage current VCOM = 1.65 V  
See Figure 13  
Digital Inputs (IN)  
VIH  
VIL  
Input logic high  
Full  
Full  
1.5  
0
5.5  
0.6  
V
V
Input logic low  
Input leakage  
current  
1.95  
V
IIH, IIL  
VIN = 5.5 V or 0  
Full  
1  
1
µA  
Dynamic  
25°C 1.65  
V to  
65  
40  
60  
70  
95  
55  
70  
72  
VCOM = V+,  
RL = 50 Ω,  
CL = 35 pF,  
See Figure 15  
tON  
Turn-on time  
Turn-off time  
ns  
ns  
ns  
1.95  
V
Full  
25°C 1.65  
V to  
VCOM = V+,  
RL = 50 Ω,  
CL = 35 pF,  
See Figure 15  
tOFF  
1.95  
V
Full  
25°C 1.65  
V to  
1
Break-before-make VNC = VNO = V+ / 2,  
CL = 35 pF,  
See Figure 16  
tBBM  
time  
RL = 50 Ω,  
1.95  
V
Full  
0.5  
QC  
CNC(OFF)  
CNO(OFF) OFF capacitance  
Charge injection  
NC, NO  
CL = 1 nF, VGEN = 0 V,  
See Figure 20  
See Figure 14  
25°C 1.8 V  
13  
23  
pC  
pF  
,
VNC or VNO = V+ or GND,  
Switch OFF,  
25°C 1.8 V  
CNC(ON)  
CNO(ON)  
,
NC, NO  
ON capacitance  
VNC or VNO = V+ or GND,  
Switch ON,  
See Figure 14  
See Figure 14  
See Figure 14  
See Figure 17  
25°C 1.8 V  
25°C 1.8 V  
25°C 1.8 V  
25°C 1.8 V  
25°C 1.8 V  
25°C 1.8 V  
84  
84  
pF  
pF  
COM  
ON capacitance  
VCOM = V+ or GND,  
Switch ON,  
CCOM(ON)  
Digital input  
capacitance  
CIN  
VIN = V+ or GND,  
2.1  
100  
–63  
–63  
pF  
RL = 50 Ω,  
Switch ON,  
BW  
OISO  
Bandwidth  
OFF isolation  
Crosstalk  
MHz  
dB  
RL = 50 Ω,  
f = 1 MHz,  
Switch OFF,  
See Figure 18  
RL = 50 Ω,  
f = 1 MHz,  
Switch ON,  
See Figure 19  
XTALK  
dB  
Supply  
25°C  
Full  
0.1  
0.5  
Positive supply  
current  
1.95  
V
I+  
VIN = V+ or GND,  
Switch ON or OFF  
μA  
Copyright © 2012, Texas Instruments Incorporated  
Submit Documentation Feedback  
7
Product Folder Links: TS5A3159-Q1  
 
TS5A3159-Q1  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
www.ti.com  
TYPICAL CHARACTERISTICS  
ron  
vs  
ron  
vs  
VCOM  
VCOM  
3.5  
3
1.6  
1.4  
1.2  
1
V
= 3 V  
T
A
= 25C  
+
T
= 85°C  
A
T
A
= 25°C  
2.5  
2
V
V
= 1.8 V  
+
T
A
= −40°C  
V
+
= 2.5 V  
0.8  
0.6  
0.4  
0.2  
0
1.5  
1
= 3 V  
+
V
= 4.5 V  
0.5  
0
+
0
1
2
3
4
0
1
2
3
V
(V)  
COM  
V
(V)  
COM  
Figure 1.  
Figure 2.  
Leakage Current  
vs  
tON/OFF  
vs  
Temperature  
V+  
50  
18  
V
= 5 V  
V
T
= V  
COM +  
= 25°C  
+
t
r
t
f
< 20 ns  
16  
14  
12  
10  
8
A
< 20 ns  
40  
30  
20  
10  
0
I
NC(ON)  
6
I
COM(ON)  
4
I
NO(ON)  
2
I
NO(OFF)  
I
NC(OFF)  
0
0
1
2
3
4
5
6
−40  
−20  
0
20  
40  
60  
80  
100  
Supply Voltage (V)  
Temperature (°C)  
Figure 3.  
Figure 4.  
tON/OFF  
vs  
Logic Threshold  
vs  
Temperature  
Power Supply  
20  
2.5  
2
t
r
t
f
= 2.5 ns  
= 2.5 ns  
V
= 5 V  
18  
16  
14  
12  
10  
8
+
V
t+  
V
1.5  
t–  
1
0.5  
0
6
4
2
0
1.5  
2
2.5  
3
3.5  
4
4.5  
5
−40  
−20  
0
20  
40  
60  
80  
100  
Power Supply (V)  
Temperature (°C)  
Figure 5.  
Figure 6.  
8
Submit Documentation Feedback  
Copyright © 2012, Texas Instruments Incorporated  
Product Folder Links: TS5A3159-Q1  
TS5A3159-Q1  
www.ti.com  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
TYPICAL CHARACTERISTICS (continued)  
Power-Supply Current  
vs  
Frequency Response  
Temperature  
14  
12  
10  
8
0
−10  
−20  
−30  
−40  
−50  
−60  
−70  
−80  
0
OFF Isolation  
V = 5 V  
+
−1  
Bandwidth  
−2  
−3  
−4  
Crosstalk  
6
−5  
−6  
4
−7  
−8  
−9  
2
0
−90  
0.1  
−40  
−20  
0
20  
40  
60  
80  
100  
1
10  
100  
1K  
Frequency (MHz)  
Temperature (°C)  
Figure 7.  
Figure 8.  
Total Harmonic Distortion (THD)  
vs  
Frequency  
0.035  
V
= 3 V  
+
0.030  
0.025  
0.020  
0.015  
0.010  
0.005  
0
10  
100  
1K  
10K  
100K  
Frequency (MHz)  
Figure 9.  
Copyright © 2012, Texas Instruments Incorporated  
Submit Documentation Feedback  
9
Product Folder Links: TS5A3159-Q1  
TS5A3159-Q1  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
www.ti.com  
PIN DESCRIPTION  
PIN  
DESCRIPTION  
NO. NAME  
1
2
3
4
5
NO  
Normally-open terminal  
GND Digital ground  
NC  
Normally-closed terminal  
COM Common terminal  
V+  
Power supply  
Digital control pin to connect COM terminal to NO or  
NC terminals  
6
IN  
PARAMETER DESCRIPTION  
SYMBOL  
VCOM  
VNC  
DESCRIPTION  
Voltage at COM  
Voltage at NC  
Voltage at NO  
VNO  
ron  
Resistance between COM and NC or COM and NO ports, when the channel is ON  
Peak ON-state resistance over a specified voltage range  
rpeak  
ron  
Difference of ron between channels  
ron(flat)  
Difference between the maximum and minimum value of ron in a channel over the specified range of conditions  
Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the OFF state under worst-case  
input and output conditions  
INC(OFF)  
INO(OFF)  
INC(ON)  
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the OFF state under worst-case  
input and output conditions  
Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the ON state and the output  
(COM) being open  
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the ON state and the output  
(COM) being open  
INO(ON)  
ICOM(ON)  
Leakage current measured at the COM port, with the corresponding channel (COM to NO or COM to NC) in the ON state  
and the output (NC or NO) being open  
VIH  
Minimum input voltage for logic high for the control input (IN)  
Minimum input voltage for logic low for the control input (IN)  
Voltage at IN  
VIL  
VIN  
IIH, IIL  
Leakage current measured at IN  
Turn-on time for the switch. This parameter is measured under the specified range of conditions and by the propagation  
delay between the digital control (IN) signal and analog outputs (COM, NC, or NO) signal, when the switch is turning ON.  
tON  
Turn-off time for the switch. This parameter is measured under the specified range of conditions and by the propagation  
delay between the digital control (IN) signal and analog outputs (COM, NC, or NO) signal, when the switch is turning OFF.  
tOFF  
tBBM  
Break-before-make time. This parameter is measured under the specified range of conditions and by the propagation delay  
between the output of two adjacent analog channels (NC and NO), when the control signal changes state.  
Charge injection is a measurement of unwanted signal coupling from the control (IN) input to the analog (NC, NO, or COM)  
output. This is measured in coulomb (C) and measured by the total charge induced due to switching of the control input.  
Charge injection, QC = CL × VO, CL is the load capacitance, and VO is the change in analog output voltage.  
QC  
CNC(OFF)  
CNO(OFF)  
CNC(ON)  
CNO(ON)  
CCOM(ON)  
CIN  
Capacitance at the NC port when the corresponding channel (NC to COM) is OFF  
Capacitance at the NO port when the corresponding channel (NO to COM) is OFF  
Capacitance at the NC port when the corresponding channel (NC to COM) is ON  
Capacitance at the NO port when the corresponding channel (NO to COM) is ON  
Capacitance at the COM port when the corresponding channel (COM to NC or COM to NO) is ON  
Capacitance of IN  
OFF isolation of the switch is a measurement OFF-state switch impedance. This is measured in dB in a specific frequency,  
with the corresponding channel (NC to COM or NO to COM) in the OFF state.  
OISO  
Crosstalk is a measurement of unwanted signal coupling from an ON channel to an OFF channel (NC to NO or NO to NC).  
This is measured in a specific frequency and in dB.  
XTALK  
BW  
Bandwidth of the switch. This is the frequency in which the gain of an ON channel is 3 dB below the DC gain.  
10  
Submit Documentation Feedback  
Copyright © 2012, Texas Instruments Incorporated  
Product Folder Links: TS5A3159-Q1  
TS5A3159-Q1  
www.ti.com  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
PARAMETER DESCRIPTION (continued)  
SYMBOL  
DESCRIPTION  
Static power-supply current with the control (IN) pin at V+ or GND  
This is the increase in I+ for each control (IN) input that is at the specified voltage, rather than at V+ or GND.  
I+  
I+  
Copyright © 2012, Texas Instruments Incorporated  
Submit Documentation Feedback  
11  
Product Folder Links: TS5A3159-Q1  
TS5A3159-Q1  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
www.ti.com  
PARAMETER MEASUREMENT INFORMATION  
V
+
V
V
NC  
NO  
NC  
COM  
V
COM  
+
Channel ON  
NO  
VCOM VNO or VNC  
ICOM  
r
on  
I
COM  
V
I
IN  
V = V or V  
I IH IL  
+
GND  
Figure 10. ON-State Resistance (ron)  
V
+
V
V
NC  
NO  
NC  
COM  
V
COM  
+
OFF-State Leakage Current  
Channel OFF  
NO  
V = V or V  
IL  
I
IH  
V
I
IN  
+
GND  
Figure 11. OFF-State Leakage Current (INC(OFF), INO(OFF)  
)
V
+
V
V
NC  
NO  
NC  
COM  
ON-State Leakage Current  
Channel ON  
V
COM  
+
NO  
V = V or V  
IL  
I
IH  
V
I
NOTE: See electrical characteristics for test conditions.  
IN  
+
GND  
Figure 12. ON-State Leakage Current (ICOM(ON), INC(ON), INO(ON)  
)
12  
Submit Documentation Feedback  
Copyright © 2012, Texas Instruments Incorporated  
Product Folder Links: TS5A3159-Q1  
TS5A3159-Q1  
www.ti.com  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
PARAMETER MEASUREMENT INFORMATION (continued)  
V
+
V
COM  
COM  
Capacitance  
Meter  
V
= V or GND  
+
BIAS  
V
NC  
NO  
NC  
V = V or V  
I IH IL  
V
NO  
Capacitance is measured at NC,  
NO, COM, and IN inputs during  
ON and OFF conditions.  
V
BIAS  
IN  
V
I
GND  
Figure 13. Capacitance (CI, CCOM(ON), CNC(OFF), CNO(OFF), CNC(ON), CNO(ON)  
)
V
+
TEST  
R
L
C
L
V
COM  
V
NC  
or V  
C
NC or NO  
NC or NO  
NO  
t
50 Ω  
50 Ω  
35 pF  
35 pF  
V
+
ON  
COM  
V
COM  
(2)  
R
L
L
t
V
+
OFF  
IN  
V
I
V
0
Logic  
Input  
+
(2)  
C
R
L
50%  
50%  
L
Logic  
(1)  
(V )  
I
GND  
Input  
t
t
OFF  
ON  
Switch  
Output  
90%  
90%  
(V  
NC  
or V )  
NO  
(1)  
(2)  
All input pulses are supplied by generators having the following characteristics: PRR10 MHz, Z = 50 Ω, t < 5 ns, t < 5 ns.  
f
O
r
C
L
includes probe and jig capacitance.  
Figure 14. Turn-On (tON) and Turn-Off Time (tOFF  
)
Copyright © 2012, Texas Instruments Incorporated  
Submit Documentation Feedback  
13  
Product Folder Links: TS5A3159-Q1  
TS5A3159-Q1  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
www.ti.com  
PARAMETER MEASUREMENT INFORMATION (continued)  
+
V
+
Logic  
Input  
V
NC  
or V  
NO  
50%  
NC or NO  
NC or NO  
(V )  
I
0
V
COM  
COM  
Switch  
Output  
90%  
t
90%  
(2)  
C
R
L
L
(V  
)
COM  
IN  
V
I
BBM  
Logic  
(1)  
V
or V = V /2  
NO +  
NC  
GND  
Input  
R
= 50 Ω  
L
L
C
= 35 pF  
(1)  
(2)  
All input pulses are supplied by generators having the following characteristics: PRR10 MHz, Z = 50 Ω, t < 5 ns, t < 5 ns.  
f
O
r
C
L
includes probe and jig capacitance.  
Figure 15. Break-Before-Make Time (tBBM  
)
V
+
Network Analyzer  
50  
V
NC  
NC  
NO  
Channel ON: NC to COM  
V = V or V  
V
COM  
COM  
I
IH  
IL  
Source  
Signal  
Network Analyzer Setup  
V
I
IN  
Source Power = 0 dBM  
50  
(632-mV P-P at 50- load)  
+
GND  
DC Bias = 350 mV  
Figure 16. Bandwidth (BW)  
V
+
Network Analyzer  
50  
Channel OFF: NC to COM  
V = V or V  
V
NC  
NC  
I
IH  
IL  
V
COM  
COM  
Source  
50  
NO  
IN  
Signal  
Network Analyzer Setup  
Source Power = 0 dBM  
V
I
(632-mV P-P at 50- load)  
50  
+
GND  
DC Bias = 350 mV  
Figure 17. OFF Isolation (OISO  
)
14  
Submit Documentation Feedback  
Copyright © 2012, Texas Instruments Incorporated  
Product Folder Links: TS5A3159-Q1  
TS5A3159-Q1  
www.ti.com  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
PARAMETER MEASUREMENT INFORMATION (continued)  
V
+
Network Analyzer  
50  
Channel ON: NC to COM  
Channel OFF: NO to COM  
V = V or V  
V
V
NC  
NC  
V
COM  
I
IH  
IL  
Source  
NO  
IN  
NO  
Signal  
Network Analyzer Setup  
50  
V
I
50  
Source Power = 0 dBM  
+
GND  
(632-mV P-P at 50- load)  
DC Bias = 350 mV  
Figure 18. Crosstalk (XTALK  
)
V
IH  
V
+
Logic  
Input  
OFF  
ON  
OFF  
V
(V  
I)  
IL  
R
GEN  
NC or NO  
NC or NO  
COM  
V
COM  
+
V
COM  
V  
COM  
V
GEN  
(2)  
C
L
V
= 0 to V  
GEN  
+
V
I
IN  
R
C
= 0  
GEN  
= 0.1 nF  
L
Logic  
(1)  
GND  
Q
= C × ∆V  
COM  
C
L
Input  
V = V or V  
I IH IL  
(1)  
(2)  
All input pulses are supplied by generators having the following characteristics: PRR10 MHz, Z = 50 Ω, t < 5 ns, t < 5 ns.  
f
O
r
C
L
includes probe and jig capacitance.  
Figure 19. Charge Injection (QC)  
Copyright © 2012, Texas Instruments Incorporated  
Submit Documentation Feedback  
15  
Product Folder Links: TS5A3159-Q1  
TS5A3159-Q1  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
www.ti.com  
PARAMETER MEASUREMENT INFORMATION (continued)  
Channel ON: COM to NC  
= V P-P  
V
V /2  
+
SOURCE  
V = V or V  
+
V
+
I
IH  
IL  
f
= 600 Hz to 20 kHz  
SOURCE  
R
C
L
10  
F
R
= 600 Ω  
L
L
NC  
NO  
C
= 50 pF  
10  
F
Analyzer  
V
O
COM  
IN  
(1)  
L
V
R
L
V
I
SOURCE  
+
GND  
(1)  
C
L
includes probe and jig capacitance.  
Figure 20. Total Harmonic Distortion (THD)  
16  
Submit Documentation Feedback  
Copyright © 2012, Texas Instruments Incorporated  
Product Folder Links: TS5A3159-Q1  
TS5A3159-Q1  
www.ti.com  
SCDS336A NOVEMBER 2012REVISED DECEMBER 2012  
REVISION HISTORY  
Changes from Original (November, 2012) to Revision A  
Page  
Device going from Preview to Production ............................................................................................................................. 1  
Changed ON-state resistance from 1.1 to 1.3 Ω. ................................................................................................................. 2  
Changd leakage current from ±20 nA to ±6 nA. ................................................................................................................... 2  
Changed ron max values from 1.1 to 1.3 ............................................................................................................................... 3  
Changed INC(OFF), INO(OFF) min and max values for 25°C from –2 and 2 to –6 and 6, respectively. Changed min and  
max values for Full from –20 and 20 to –150 and 150, respectively. ................................................................................... 3  
Changed INC(ON), INO(ON) min and max values for 25°C from –4 and 4 to –6 and 6, respectively. Changed min and  
max values for Full from –40 and 40 to –150 and 150, respectively. ................................................................................... 3  
Changed ICOM(ON) min and max values for 25°C from –4 and 4 to –8 and 8, respectively. Changed min and max  
values for Full from –40 and 40 to –150 and 150, respectively. ........................................................................................... 3  
Inserted 25°C above Full in TA column and inserted 0.5 µA max value for I+ ...................................................................... 4  
Changed max values for rpeak from 2.1 to 2.2. ...................................................................................................................... 4  
Changed max values for ron from 1.5 to 1.8. ........................................................................................................................ 4  
Added 25°C to TA column and added 0.5 max value to I+ .................................................................................................... 5  
Changed rpeak max values from 2.7 to 2.9. ........................................................................................................................... 5  
Changed ron max values from 2 to 2.3. ................................................................................................................................. 5  
Added 25°C to TA column and added 0.5 max value to I+. ................................................................................................... 6  
Changed rpeak max values from 4.9 to 5.2. ........................................................................................................................... 6  
Changed ron max values from 3.2 to 3.5. .............................................................................................................................. 6  
Added 25°C to TA column and added 0.5 max value to I+. ................................................................................................... 7  
Copyright © 2012, Texas Instruments Incorporated  
Submit Documentation Feedback  
17  
Product Folder Links: TS5A3159-Q1  
PACKAGE OPTION ADDENDUM  
www.ti.com  
24-Jan-2013  
PACKAGING INFORMATION  
Orderable Device  
Status Package Type Package Pins Package Qty  
Eco Plan Lead/Ball Finish  
MSL Peak Temp  
Op Temp (°C)  
Top-Side Markings  
Samples  
Drawing  
(1)  
(2)  
(3)  
(4)  
TS5A3159QDBVRQ1  
ACTIVE  
SOT-23  
DBV  
6
3000  
Green (RoHS  
& no Sb/Br)  
CU NIPDAU  
Level-1-260C-UNLIM  
UAAQ  
(1) The marketing status values are defined as follows:  
ACTIVE: Product device recommended for new designs.  
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.  
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.  
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.  
OBSOLETE: TI has discontinued the production of the device.  
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability  
information and additional product content details.  
TBD: The Pb-Free/Green conversion plan has not been defined.  
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that  
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.  
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between  
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.  
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight  
in homogeneous material)  
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.  
(4) Only one of markings shown within the brackets will appear on the physical device.  
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information  
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and  
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.  
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.  
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.  
OTHER QUALIFIED VERSIONS OF TS5A3159-Q1 :  
Catalog: TS5A3159  
Enhanced Product: TS5A3159-EP  
Addendum-Page 1  
PACKAGE OPTION ADDENDUM  
www.ti.com  
24-Jan-2013  
NOTE: Qualified Version Definitions:  
Catalog - TI's standard catalog product  
Enhanced Product - Supports Defense, Aerospace and Medical Applications  
Addendum-Page 2  
PACKAGE MATERIALS INFORMATION  
www.ti.com  
19-Dec-2012  
TAPE AND REEL INFORMATION  
*All dimensions are nominal  
Device  
Package Package Pins  
Type Drawing  
SPQ  
Reel  
Reel  
A0  
B0  
K0  
P1  
W
Pin1  
Diameter Width (mm) (mm) (mm) (mm) (mm) Quadrant  
(mm) W1 (mm)  
TS5A3159QDBVRQ1  
SOT-23  
DBV  
6
3000  
180.0  
8.4  
3.23  
3.17  
1.37  
4.0  
8.0  
Q3  
Pack Materials-Page 1  
PACKAGE MATERIALS INFORMATION  
www.ti.com  
19-Dec-2012  
*All dimensions are nominal  
Device  
Package Type Package Drawing Pins  
SOT-23 DBV  
SPQ  
Length (mm) Width (mm) Height (mm)  
202.0 201.0 28.0  
TS5A3159QDBVRQ1  
6
3000  
Pack Materials-Page 2  
IMPORTANT NOTICE  
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other  
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest  
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and  
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale  
supplied at the time of order acknowledgment.  
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms  
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary  
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily  
performed.  
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and  
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide  
adequate design and operating safeguards.  
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or  
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information  
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or  
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the  
third party, or a license from TI under the patents or other intellectual property of TI.  
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration  
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered  
documentation. Information of third parties may be subject to additional restrictions.  
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service  
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.  
TI is not responsible or liable for any such statements.  
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements  
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support  
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which  
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause  
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use  
of any TI components in safety-critical applications.  
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to  
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and  
requirements. Nonetheless, such components are subject to these terms.  
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties  
have executed a special agreement specifically governing such use.  
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in  
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components  
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and  
regulatory requirements in connection with such use.  
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of  
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.  
Products  
Applications  
Audio  
www.ti.com/audio  
amplifier.ti.com  
dataconverter.ti.com  
www.dlp.com  
Automotive and Transportation www.ti.com/automotive  
Communications and Telecom www.ti.com/communications  
Amplifiers  
Data Converters  
DLP® Products  
DSP  
Computers and Peripherals  
Consumer Electronics  
Energy and Lighting  
Industrial  
www.ti.com/computers  
www.ti.com/consumer-apps  
www.ti.com/energy  
dsp.ti.com  
Clocks and Timers  
Interface  
www.ti.com/clocks  
interface.ti.com  
logic.ti.com  
www.ti.com/industrial  
www.ti.com/medical  
Medical  
Logic  
Security  
www.ti.com/security  
Power Mgmt  
Microcontrollers  
RFID  
power.ti.com  
Space, Avionics and Defense  
Video and Imaging  
www.ti.com/space-avionics-defense  
www.ti.com/video  
microcontroller.ti.com  
www.ti-rfid.com  
www.ti.com/omap  
OMAP Applications Processors  
Wireless Connectivity  
TI E2E Community  
e2e.ti.com  
www.ti.com/wirelessconnectivity  
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265  
Copyright © 2013, Texas Instruments Incorporated  

相关型号:

TS5A3159A

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADBVR

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADBVRE4

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADBVRG4

1-Ω SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADBVT

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADBVTE4

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADBVTG4

1-Ω SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADCKR

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADCKRE4

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADCKRG4

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADCKT

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI

TS5A3159ADCKTE4

1-ohm SPDT ANALOG SWITCH 5-V/3.3-V SINGLE-CHANNEL 2:1 MULTIPLEXER/DEMULTIPLEXER
TI