FEATURES
►DIP-24 Plastic Package
►Wide 2:1 Input Range
►High Efficiency up to 84%
►Operating Temp. Range -40°C to +85°C
►Overload Protection
►I/O-Isolation Voltage 1500VDC (opt. 3000VDC)
►Input Filter meets EN 55022,class A and FCC, level A
►3 Years Product Warranty
PRODUCT OVERVIEW
The MIW06 series is a new range of high performance dc-dc converter modules with6W output power, featuring wide 2:1 input voltage ranges and tight
output voltage regulation. The product comes in a DIP-24 package with industry standard footprint.
Excellent efficiency allows an operation temperature range of -40°C to +85°C (with derating).Standard features include overload protection.
Typical applications for these cost optimized converters are battery powered equipment, instrumentation, datacom and industrial electronics.
Model Selection Guide
Model
Input
Voltage
(Range)
VDC
Output
Output
Current
Max.
mA
Input Current
Reflected
Ripple
Max. capacitive
Load
Efficiency
Number
Voltage
(typ.)
@Max. Load
@No Load
mA(typ.)
Current
mA(typ.)
@Max. Load
VDC
3.3
5
mA(typ.)
440
641
609
609
595
534
609
609
214
313
298
298
298
260
298
298
107
156
149
149
149
130
149
149
uF
470
470
100
100
47
%
MIW06-12S033
MIW06-12S05
MIW06-12S12
MIW06-12S15
MIW06-12S24
MIW06-12D05
MIW06-12D12
MIW06-12D15
MIW06-24S033
MIW06-24S05
MIW06-24S12
MIW06-24S15
MIW06-24S24
MIW06-24D05
MIW06-24D12
MIW06-24D15
MIW06-48S033
MIW06-48S05
MIW06-48S12
MIW06-48S15
MIW06-48S24
MIW06-48D05
MIW06-48D12
MIW06-48D15
1200
1200
500
75
78
82
82
84
78
82
82
77
80
84
84
84
80
84
84
77
80
84
84
84
80
84
84
12
15
400
12
(9 ~ 18)
40
20
10
30
20
15
24
250
±5
±12
±15
3.3
5
±500
±250
±200
1200
1200
500
100#
100#
100#
470
470
100
100
47
12
15
400
24
(18 ~ 36)
24
250
±5
±12
±15
3.3
5
±500
±250
±200
1200
1200
500
100#
100#
100#
470
470
100
100
47
12
15
400
48
(36 ~ 75)
24
250
±5
±12
±15
±500
±250
±200
100#
100#
100#
# For each output
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com
MIW06 SERIES
DC/DC CONVERTER 6W, DIP-Package
Total Power International, Inc.
Input Specifications
Parameter
Model
Min.
-0.7
-0.7
-0.7
7
Typ.
---
---
---
8
Max.
25
Unit
12V Input Models
24V Input Models
48V Input Models
12V Input Models
24V Input Models
48V Input Models
12V Input Models
24V Input Models
48V Input Models
50
Input Surge Voltage (1 sec. max.)
Start-Up Voltage
100
9
VDC
14
16
34
---
---
---
---
---
18
32
36
---
8.5
16
Under Voltage Shutdown
---
---
35
Short Circuit Input Power
Internal Power Dissipation
Conducted EMI
---
3000
2500
mW
mW
All Models
---
Compliance to EN 55022,class A and FCC part 15,class A
Output Specifications
Parameter
Conditions
Min.
---
Typ.
±1.0
±1.0
±0.1
±0.6
Max.
±2.0
±2.0
±0.5
±1.2
Unit
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Dual Output, Balanced Loads
Vin=Min. to Max.
---
%
---
%
Load Regulation
Io=0% to 100%
---
%
Min.Load
No minimum Load Requirement
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
---
---
50
---
80
100
600
---
mV P-P
mV P-P
uS
Over Line, Load % Temp.
25% Load Step Change
---
300
±3
---
%
---
±0.01
145
±0.02
---
%/℃
%
Foldback
110
Continuous
General Specifications
Parameter
Conditions
Min.
1500
3000
1000
---
Typ.
---
Max.
---
Unit
VDC
VDC
MΩ
Standard
Suffix H(note 6)
I/O Isolation Voltage (rated)
60 Seconds
---
---
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
500 VDC
---
---
100KHz, 1V
1000
330
---
---
pF
---
---
KHz
Hours
MIL-HDBK-217F@25℃, Ground Benign
1,000,000
---
Safety Approvals(pending)
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Input Fuse
12V Input Models
1500mA Slow-Blow Type
24V Input Models
48V Input Models
700mA Slow-Blow Type
350mA Slow-Blow Type
Environmental Specifications
Parameter
Conditions
Ambient
Min.
-40
---
Max.
Unit
Operating Temperature Range (with Derating)
Case Temperature
+85
+100
+125
95
℃
℃
℃
Storage Temperature Range
Humidity (non condensing)
Cooling
-50
---
% rel. H
Free-Air convection
---
Lead Temperature (1.5mm from case for 10Sec.)
260
℃
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com
MIW06 SERIES
DC/DC CONVERTER 6W, DIP-Package
Total Power International, Inc.
Power Derating Curve
(3.3 & 5V Output Models)
(Other Output Models)
Notes
1
2
3
4
5
6
7
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%
Ripple & Noise measurement bandwidth is 0-20MHz.
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
To order the converter at 3KVDC isolation, please add a suffix H (e.g. MIW06-12S05H) to order code.
Specifications subject to change without notice.
Package Specifications
Mechanical Dimensions
Pin Connections
Pin
Single Output
Dual Output
-Vin
2
-Vin
3
-Vin
-Vin
9
No Pin
Common
-Vout
11
14
16
22
23
NC
+Vout
+Vout
0.50 [0.02]
-Vout
Common
+Vin
+Vin
+Vin
+Vin
2
3
9
11
14
NC: No Connection
Bottom View
23 22
16
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
15.24 [0.60]
31.8 [1.25]
5.08 4.5
[0.20][0.18]
2.54
[0.10]
X.XX±0.13 ( X.XXX±0.005)
►Pin diameter 0.5 ±0.05 (0.02±0.002)
Physical Characteristics
Case Size
Case Material
Weight
:
:
:
31.8x20.3x10.2mm (1.25x0.80x0.40 Inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
12.7g
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com
MIW06 SERIES
DC/DC CONVERTER 6W, DIP-Package
Total Power International, Inc.
Test Configurations
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0Ω at 100 KHz) to simulate source impedance.
Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+Vin
+Out
+
+
Lin
DC / DC
Converter
Current
Probe
Load
Battery
Cin
-Vin
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
Copper Strip
Cout
+Vin
+Out
-Out
Copper Strip
Cout
+Vin
+Out
Com.
-Out
Scope
Scope
Single Output
DC / DC
Converter
Dual Output
DC / DC
Converter
Resistive
Load
Resistive
Load
Scope
Copper Strip
Cout
-Vin
Copper Strip
-Vin
Copper Strip
Design & Feature Considerations
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 3.3uF for the 12V input devices and a 2.2uF for the 24V and 48V devices.
+
+Vin
+Out
+
DC / DC
Converter
DC Power
Source
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3uF capacitors at the output.
+
+Vin
+Out
+
+Vin
+Out
Com.
-Out
Single Output
DC / DC
Converter
Load
Load
Dual Output
DC / DC
Converter
DC Power
Source
Cout
Cout
DC Power
Source
Cout
Load
-
-Vin
-Out
-
-Vin
Maximum Capacitive Load
The MIW06 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 100℃.
The derating curves are determined from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
Air Flow
50mm / 2in
15mm / 0.6in
DUT
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com
相关型号:
©2020 ICPDF网 联系我们和版权申明