960W Single Output Industrial DIN RAIL with PFC Function  
SDR-960 series  
Features :  
AC input 180~264VAC  
130% peak load capability  
Width only 110mm  
Built-in active PFC function compliance to EN61000-3-2  
High efficiency 94% and low power dissipation  
Protections: Short circuit / Overload / Over voltage / Over temperature  
Cooling by free air convection  
Built-in constant current limiting circuit  
Can be installed on DIN rail TS-35/7.5 or 15  
UL508(industrial control equipment)approved  
EN61000-6-2(EN50082-2) industrial immunity level  
Current sharing up to 3840W(3+1)  
Built-in DC OK relay contact  
100% full load burn-in test  
3 years warranty  
SPECIFICATION  
MODEL  
SDR-960-24  
SDR-960-48  
DC VOLTAGE  
24V  
48V  
RATED CURRENT  
CURRENT RANGE  
RATED POWER  
PEAK CURRENT  
PEAK POWER  
40A  
0 ~ 40A  
20A  
0 ~ 20A  
960W  
26A  
960W  
52A  
Note.6 1248W (3sec.)  
OUTPUT  
RIPPLE & NOISE (max.) Note.2 180mVp-p  
VOLTAGE ADJ. RANGE  
VOLTAGE TOLERANCE Note.3 1.0%  
250mVp-p  
48 ~ 55V  
1.0%  
24 ~ 28V  
LINE REGULATION  
LOAD REGULATION  
SETUP, RISE TIME  
HOLD UP TIME (Typ.)  
0.5%  
0.5%  
1.0%  
1.0%  
1000ms, 100ms/230VAC at full load  
14ms / 230VAC at full load  
VOLTAGE RANGE  
Note.7 180 ~ 264VAC  
47 ~ 63Hz  
254 ~ 370VDC  
FREQUENCY RANGE  
POWER FACTOR (Typ.)  
PF 0.95/230VAC at full load  
94%  
EFFICIENCY (Typ.)  
94%  
INPUT  
6A/230VAC  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
COLD START 50A  
<3.5mA / 240VAC  
LEAKAGE CURRENT  
Normally works within 105 ~ 130% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery  
after 30 seconds if the peak load condition is removed  
OVERLOAD  
Constant current limiting within 130 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage, re-power  
on to recover  
PROTECTION  
56 ~ 65V  
Protection type : Shut down o/p voltage, with auto-recovery or re-power on to recover  
90 (TSW) detect on heatsink of power switch  
29 ~ 33V  
OVER VOLTAGE  
5
OVER TEMPERATURE  
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down  
60Vdc/0.3A, 24Vdc/1A, 30Vac/0.5A resistive load  
Please refer to function manual  
DC OK REALY CONTACT RATINGS (max.)  
FUNCTION  
CURRENT SHARING  
-30 ~ +70 (Refer to "Derating Curve")  
Note.5  
WORKING TEMP.  
20 ~ 95% RH non-condensing  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH  
ENVIRONMENT  
TEMP. COEFFICIENT  
VIBRATION  
0.03%/ (0 ~ 50  
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6  
UL508, UL60950-1, TUV EN60950-1 approved  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
EMC EMISSION  
EMC IMMUNITY  
MTBF  
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC  
SAFETY &  
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH  
EMC  
(Note 4)  
Compliance to EN55022 (CISPR22), EN61204-3 , EN61000-3-2,-3  
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A  
69.8K hrs min. MIL-HDBK-217F (25  
110*125.2*150mm (W*H*D)  
)
OTHERS  
NOTE  
DIMENSION  
2.47Kg ; 6pcs/15.8Kg/1.55CUFT  
PACKING  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets  
EMC directives.  
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.  
In case the adjacent device is a heat source, 15mm clearance is recommended.  
6. 3 seconds peak power max. and the average output power should not exceed the rate power.  
7. Derating may be needed under low input voltage. Please check the derating curve for more details.  
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com  
960W Single Output Industrial DIN RAIL with PFC Function  
SDR-960 series  
Mechanical Specification  
Case No.214A  
Unit:mm  
1234  
125.2  
CN205  
1234  
1
2
3
4
5
6
TB1  
1
2
3
TB2  
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15  
Terminal Pin No. Assignment (TB1)  
Pin No. Assignment  
Terminal Pin No. Assignment (TB2)  
Pin No. Assignment  
Control Pin (CN205) : DINKLE ECH250R-04P or equivalent  
Pin No.  
Assignment  
Mating Housing  
Wire Diameter  
DINKLE ESC250V-04P  
1
2
3
FG  
1,2,3 DC OUTPUT +V  
1
2
P-(Current Share)  
P+(Current Share)  
DC OK Relay Contact  
0.081~0.517mm2  
(28~20AWG)  
or equivalent  
(Including in the  
single package)  
AC/N  
AC/L  
3,4,6  
DC OUTPUT -V  
3,4  
Block Diagram  
PFC fosc : 65KHz  
PWM fosc : 60KHz  
DC OK  
RECTIFIERS  
&
FILTER  
EMI FILTER  
&
RECTIFIERS  
POWER  
SWITCHING  
PFC  
+V  
-V  
I/P  
CIRCUIT  
O.C.P.  
U.V.P.  
O.L.P.  
DETECTION  
CIRCUIT  
FG  
PWM & PFC  
CONTROL  
PFC  
CURRENT  
SHARE  
CONTROL  
CURRENT SHARE  
O.V.P.  
DC OK Relay Contact  
Contact Close  
Contact Open  
PSU turns on / DC OK.  
PSU turns off / DC Fail.  
Contact Ratings (max.) 30V/1A resistive load.  
File Name:SDR-960-SPEC 2012-09-07  
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com  
960W Single Output Industrial DIN RAIL with PFC Function  
SDR-960 series  
Peak Loading  
( 1 )  
( 2 )  
1248W  
1248W  
960W  
480W  
50 sec.  
3 sec.  
15 sec. 3 sec.  
Derating Curve  
Output derating VS input voltage  
100  
90  
80  
70  
60  
50  
40  
130  
100  
80  
For 3 sec. (typ.)  
Continuous  
60  
40  
20  
-30  
0
10  
20  
30  
40  
50  
60  
70 (VERTICAL)  
180  
190  
200  
210  
220  
230  
240  
250  
264  
AMBIENT TEMPERATURE (  
)
INPUT VOLTAGE (V) 60Hz  
Function Manual  
1. Current sharing  
(1) Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel).  
(2) Difference of output voltages among parallel units should be less than 0.2V.  
(3) The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9.  
(4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications.  
(5) The power supplies should be paralleled using short and large diameter wiring and then connected to the load.  
(6) When in parallel operation, the minimum output load should be greater than 5% of total output load.  
(Min. load >5% rated current per unit x number of unit)  
(7) In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition.  
The other PSUs (slaves) may go into standby mode and their output LEDs & relays will not turn on.  
(8) Some minor noise may be heard at light load condition under parallel operation.  
This is a normal phenomenon and the performance of the PSU will not be influenced.  
PSU  
PSU  
PSU  
PSU  
TB2  
+V  
TB2  
+V  
TB2  
+V  
TB2  
-V +V  
-V  
-V  
-V  
CN205  
CN205  
CN205  
CN205  
1
2
3
4
P-  
P+  
DC OK  
DC OK  
1
2
3
4
P-  
P+  
DC OK  
DC OK  
1
2
3
4
P-  
P+  
DC OK  
DC OK  
1
2
3
4
P-  
P+  
DC OK  
DC OK  
P-(pin1)  
P+(pin2)  
P+ and P- lines  
should be twisted in pairs  
-V  
+V  
LOAD  
File Name:SDR-960-SPEC 2012-09-07  

相关型号:

SDR-A

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-B

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-BK

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-BL

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-BN

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-G

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-GN

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-GY

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-L

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-L1

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-L2

STD Tape Dispenser SDR Wire Marking Tape
3M

SDR-L3

STD Tape Dispenser SDR Wire Marking Tape
3M