TPS40LB SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY  
KEY FEATURES  
*Universal input  
*Built-in EMI filter  
*LOW COST  
*Optional constant current change (for single output)  
APPLICATIONS  
*Telecommunications  
*Computer peripherals/Lan & Hub  
*Test & industrial equipments  
*Medical instruments  
*Business machines  
ELECTRICAL SPECIFICATIONS  
EMI & EMC (IN PROCESS)  
*FCC part 15, Class B  
INPUT  
*CISPR 22 / EN55022, Class B  
*VCCI ,Class 2  
*Input range-----------90~264 VAC, universal  
*Frequency------------47~63Hz  
*CE , EN61000-3-2 (Class A) and –3 ; EN61000-4-2,  
-3 , -4 , -5 , -6 and -11  
*Inrush current--------30A typical, Cold start @25,115VAC  
*Efficiency------------65% ~80% typical at full load  
*EMI filter------------FCC Class B conducted, CISPR 22  
Class B conducted, EN55022 class B  
Conducted  
SAFETY APPROVAL(IN PROCESS)  
*Line regulation----- +/- 0.5% typical  
*UL1950 / c UL  
*Optional CSA 22.2, LEVEL 3  
*TUV EN60950  
OUTPUT  
*Optional UL 2601(EMI Class A)  
*Maximum power----40W convection(Refer next page)  
*Hold-up time --------10ms typical at full load and 115 VAC  
nominal line  
ENVIRONMENTAL  
*Overload protection-Short circuit protection  
*Overvoltage  
protection ------------Main output 20% to 40% above  
nominal output  
*Operating temperature :  
0 to 50ambient; derate each output at 2.5% per  
degree from 50to 70℃  
*Humidity:  
*Ripple/Noise -------- +/- 1% Max. @full load  
(Optional +/-0.5% per inquiry)  
Operating; non-condensing, 5% to 95%  
*Vibration :  
10~55 Hz at 1G 3 minutes period, 30 minutes along  
X, Y and Z axis  
Power Derating Curve  
65W  
40W  
*Storage temperature:  
-40 to 85℃  
*Temperature coefficient:  
+/- 0.05% per degree C  
Output  
Power  
(Watts)  
Natural  
Convection  
Cooling  
25W  
10W  
0W  
20 W  
*MTBF demonstrated:  
0
10  
20 30 40 50 60 70  
>100,000 hours at full load and 25ambient  
conditions  
°
Ambient Temperature( C)  
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395  
E-mail: sales@total-power.com http://www.total-power.com  
-1-  
TOTAL POWER  
TPS40LB SWITCHING MODE 40W LOW COST BOX TYPE  
OUTPUT ADJUSTMENT MAXIMUM OUTPUT  
VOLTAGE RANGE CURRENT  
PEAK OUTPUT  
MINIMUM OUTPUT  
CURRENT  
TOTAL  
RIPPLE & NOISE  
%P-P(NOTE2)  
PEAK OUTPUT  
POWER(NOTE1)  
MODEL  
CURRENT(NOTE1)  
REGULATION(NOTE3)  
SINGLE OUTPUT MODEL SELECTION CHART  
±10% Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
35W Typical  
TPS40LB-10  
TPS40LB-11  
TPS40LB-12  
TPS40LB-13  
TPS40LB-14  
TPS40LB-15  
+5V  
8A  
10.4A  
4.33A  
3.46A  
2.16A  
1.08A  
10.4A  
0A  
0A  
0A  
0A  
0A  
0A  
±3%  
±3%  
±3%  
±3%  
±3%  
±5%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1.5%  
+ 12V ±10% Typical  
3.33A  
2.66A  
1.66A  
0.83A  
8A  
+15V  
+24V  
+48V  
±10% Typical  
±10% Typical  
±10% Typical  
+3.3V ±10% Typical  
DUAL OUTPUT MODEL SELECTION CHART  
±10% Typical  
+5V  
+12 V  
+5V  
4A  
2.5A  
6A  
7.8A  
5.2A  
0.4A  
0.25A  
0.6A  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±10%  
±5%  
±10%  
±5%  
±10%  
±1.5%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1.5%  
±1%  
±1%  
±1%  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
TPS40LB-20  
TPS40LB-21  
TPS40LB-22  
TPS40LB-23  
TPS40LB-24  
TPS40LB-25  
TPS40LB-26  
Fixed  
±10% Typical  
Fixed  
7.8A  
+24V  
+5 V  
-5V  
0.5A  
5A  
1.3A  
0.05A  
0.5A  
±10% Typical  
Fixed  
6.5A  
3A  
1.3A  
0.3A  
±10% Typical  
Fixed  
+12V  
-12V  
+15V  
-15V  
+3.3V  
+12V  
+5V  
2A  
4.68A  
1.17A  
2.21A  
2.21A  
11.57A  
1.17A  
13A  
0.2A  
2A  
0.2A  
±10% Typical  
Fixed  
1.4A  
1.4A  
8.9A  
0.9A  
1A  
0.14A  
0.14A  
0.89A  
0.09A  
0.1A  
±10% Typical  
Fixed  
±10% Typical  
Fixed  
+48V  
0.8A  
0.26A  
0.08A  
TRIPLE OUTPUT MODEL SELECTION CHART  
±10% Typical  
+ 5V  
+12V  
-5V  
3A  
3.9A  
0.3A  
0.2A  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
Fixed  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
52W Typical  
TPS40LB-30  
TPS40LB-31  
TPS40LB-32  
TPS40LB-33  
TPS40LB-34  
TPS40LB-35  
TPS40LB-36  
TPS40LB-37  
TPS40LB-38  
2A  
2.6A  
Fixed  
0.5A  
3A  
0.65A  
3.9A  
0.05A  
0.3A  
±10% Typical  
+ 5V  
+12V  
- 12V  
+ 5V  
+15V  
-15V  
+5V  
Fixed  
2A  
2.6A  
0.2A  
Fixed  
0.5A  
3A  
0.65A  
3.9A  
0.05A  
0.3A  
±10% Typical  
Fixed  
2A  
2.6A  
0.2A  
Fixed  
0.5A  
3A  
0.65A  
3.9A  
0.05A  
0.3A  
±10% Typical  
Fixed  
+15V  
- 5 V  
+ 5V  
+15V  
-12V  
+ 5V  
+24V  
-12V  
+5V  
2A  
2.6A  
0.2A  
Fixed  
0.5A  
3A  
0.65A  
3.9A  
0.05A  
0.3A  
±10% Typical  
Fixed  
Fixed  
1.5A  
0.5A  
3A  
1.3A  
0.15A  
0.05A  
0.3A  
±
5%  
±
1%  
0.65A  
3.9A  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±1%  
±1%  
±1%  
±1%  
±1.5%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1.5%  
±1%  
±1%  
±10% Typical  
Fixed  
Fixed  
1A  
1.3A  
0.1A  
0.5A  
1A  
0.65A  
9.1A  
0.05A  
0.1A  
±10% Typical  
+12  
Fixed  
Fixed  
2.5A  
0.5A  
3A  
1.95A  
1.04A  
3.9A  
0.25A  
0.05A  
0.3A  
-12V  
+ 5V  
+12V  
+24V  
+5V  
±10% Typical  
Fixed  
Fixed  
1.5A  
0.5A  
2A  
1.3A  
0.15A  
0.05A  
0.2A  
0.65A  
9.1A  
±10% Typical  
+12V  
+48V  
Fixed  
Fixed  
0.5A  
0.6A  
1.95A  
1.04A  
0.05A  
0.06A  
NOTES:  
1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.  
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, 0.1μF and 47μF Cap. on outputs.  
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.  
4) Detailed engineering specification of each model is available for inquiry.  
5) Special output voltage/current inquiry is welcomed.  
6) Specifications subject to change without notice.  
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395  
E-mail: sales@total-power.com http://www.total-power.com  
-2-  

相关型号:

TPS40LB-26

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS40LB-30

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS40LB-31

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS40LB-32

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS40LB-33

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS40LB-34

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS40LB-35

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS40LB-36

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS40LB-37

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS40LB-38

SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
TOTAL-POWER

TPS4100

FOUR CHANNEL BRIDGED OUTPUT POWER STAGE
TRIPATH

TPS4100A

FOUR CHANNEL BRIDGED OUTPUT POWER STAGE
TRIPATH