TBA1-0311 [TRACOPOWER]

Continuous short circuit protection;
TBA1-0311
型号: TBA1-0311
厂家: TRACO ELECTRONIC AG    TRACO ELECTRONIC AG
描述:

Continuous short circuit protection

文件: 总3页 (文件大小:766K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC/DC Converter  
TBA 1 Series, 1 Watt  
Continuous short circuit protection  
I/O isolation: 1'060 VAC  
Operating temperature range  
-40 to +85 °C without derating  
Input voltage ranges (±10%):  
3.3, 5, 12, 24 VDC  
High efficiency up to 82%  
SIP-4 package  
Unregulated outputs  
The TBA 1 is an elementary 1 Watt DC/DC SIP converter series which is specif-  
ically designed to offer a low-cost solution with no concession on quality and  
lifetime. The new design improves on the industry standard features and offers  
an integrated continuous short circuit protection circuit, an operating tempera-  
ture range from –40°C to 85°C without derating and I/O-isolations of either  
1’060 VAC. It offers a broad application range in any space and cost critical ap-  
plication.  
3-year product waranty  
Models  
Order Code  
Input Voltage  
Range  
Output Voltage  
nom.  
Output Current  
max.  
Efficiency  
typ.  
3.3 VDC  
5 VDC  
73 %  
76 %  
75 %  
79 %  
80 %  
82 %  
82 %  
79 %  
79 %  
80 %  
80 %  
79 %  
80 %  
82 %  
82 %  
TBA 1-0310  
TBA 1-0311  
TBA 1-0510  
TBA 1-0511  
TBA 1-0519  
TBA 1-0512  
TBA 1-0513  
TBA 1-1211  
TBA 1-1219  
TBA 1-1212  
TBA 1-1213  
TBA 1-2411  
TBA 1-2419  
TBA 1-2412  
TBA 1-2413  
260 mA  
200 mA  
260 mA  
200 mA  
110 mA  
80 mA  
2.97 - 3.63 VDC  
(3.3 VDC nom.)  
3.3 VDC  
5 VDC  
4.5 - 5.5 VDC  
(5 VDC nom.)  
9 VDC  
12 VDC  
15 VDC  
5 VDC  
65 mA  
200 mA  
110 mA  
80 mA  
9 VDC  
10.8 - 13.2 VDC  
(12 VDC nom.)  
12 VDC  
15 VDC  
5 VDC  
65 mA  
200 mA  
110 mA  
80 mA  
9 VDC  
21.6 - 26.4 VDC  
(24 VDC nom.)  
12 VDC  
15 VDC  
65 mA  
Page 1 / 3  
www.tracopower.com  
August 27, 2019  
TBA 1 Series, 1 Watt  
Input Specifications  
Input Current  
- At no load  
3.3 Vin models: 30 mA typ.  
5 Vin models: 25 mA typ.  
12 Vin models: 15 mA typ.  
24 Vin models: 10 mA typ.  
Surge Voltage  
3.3 Vin models: 5 VDC max. (1 s max.)  
5 Vin models: 9 VDC max. (1 s max.)  
12 Vin models: 18 VDC max. (1 s max.)  
24 Vin models: 30 VDC max. (1 s max.)  
3.3 Vin models: 800 mA (slow blow)  
5 Vin models: 500 mA (slow blow)  
12 Vin models: 200 mA (slow blow)  
24 Vin models: 100 mA (slow blow)  
Recommended Input Fuse  
Input Filter  
Internal Capacitor (external capacitor recom-  
mended)  
Output Specifications  
Voltage Set Accuracy  
±3% max. (at 60% for 5VDC models)  
±3% max. (at 80% for other models)  
1.5% max. (at 1% change of Vin)  
(see application note:  
Regulation  
- Input Variation (Vmin - Vmax)  
- Load Variation  
www.tracopower.com/overview/tba1)  
Ripple and Noise  
Capacitive Load  
- 20 MHz Bandwidth  
200 mVp-p max.  
65 mVp-p typ.  
3.3 Vout models: 3'300 µF max.  
5 Vout models: 2'200 µF max.  
9 Vout models: 1'000 µF max.  
12 Vout models: 470 µF max.  
15 Vout models: 470 µF max.  
Not required  
Minimum Load  
Temperature Coefficient  
Start-up Time  
±0.02 %/K max.  
30 ms max.  
Short Circuit Protection  
Continuous, Automatic recovery  
Safety Specifications  
Safety Standards  
- IT / Multimedia Equipment  
Designed for EN 60950-1 (no certification)  
General Specifications  
Relative Humidity  
95% max. (non condensing)  
–40°C to +95°C  
Temperature Ranges  
- Operating Temperature  
- Case Temperature  
- Storage Temperature  
- High Temperature  
+105°C max.  
–55°C to +125°C  
5 %/K above 85°C  
Natural convection (20 LFM)  
50 - 200 kHz (PWM)  
Functional Insulation  
1'060 VAC  
1'000 MOhm min.  
30 pF max.  
2'000'000 h (MIL-HDBK-217F, ground benign)  
Plastic (UL 94 V-0 rated)  
Epoxy (UL 94 V-0 rated)  
Tinned Copper  
Power Derating  
Cooling System  
Switching Frequency  
Insulation System  
Isolation Test Voltage  
Isolation Resistance  
Isolation Capacitance  
Reliability  
- Input to Output, 60 s  
- Input to Output, 500 VDC  
- Input to Output, 100 kHz, 1 V  
- Calculated MTBF  
Housing Material  
Potting Material  
Pin Material  
Connection Type  
THD (Through-Hole Device)  
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.  
www.tracopower.com August 27, 2019  
Page 2 / 3  
TBA 1 Series, 1 Watt  
Weight  
1.6 g  
www.tracopower.com/info/reach-declaration.pdf  
www.tracopower.com/info/rohs-declaration.pdf  
Environmental Compliance - Reach  
- RoHS  
Supporting Documents  
Overview Link (for additional Documents)  
www.tracopower.com/overview/tba1  
Outline Dimensions  
ꢀꢀ068 (±046)  
Pinout  
Pin  
1
Function  
–Vin (GND)  
+Vin (Vcc)  
–Vout  
2
3
4
+Vout  
Front view  
1
2
3
4
.0±3 min0  
(±0ꢀ2 min0)  
20±.  
(±0±8)  
2034  
(±0ꢀ±)  
2034  
(±0ꢀ±)  
2034  
(±0ꢀ±)  
60±±  
(±024)  
Bottom view  
±03±  
(±0±2)  
Dimensions in mm (inch)  
±03± ! ±023  
(±0±2 ! ±0±ꢀ)  
Tolerances: ± ±0.3 (± ±0±ꢀ)  
©
Copyright 2019 Traco Electronic AG  
Specifications can be changed without notice.  
Rev. August 27, 2019  
www.tracopower.com  
Page 3 / 3  

相关型号:

TBA1-0510

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0511

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0511E

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0511HI

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0512

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0512E

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0512HI

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0513

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0513E

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0513HI

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0519

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TBA1-0519HI

Continuous short circuit protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER