TDR3-2411WI [TRACOPOWER]
DC/DC Converters;型号: | TDR3-2411WI |
厂家: | TRACO ELECTRONIC AG |
描述: | DC/DC Converters |
文件: | 总4页 (文件大小:350K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC/DC Converters
TDR 3WI Series, 3 Watt
UL 60950-1
Features
◆ Compact design in SMD or DIP package
◆ Ultra wide 4:1 input voltage range
◆ Fully regulated outputs
◆ Low ripple and noise
◆ No minimum load required
◆ Temperature range –40°C to +85°C
◆ I/O isolation 1600 VDC
◆ Continuous short-circuit protection
◆ Remote On/Off control
◆ Fully RoHS compliant
The TDR-3WI series is a family of compact 3 W DC/DC converters with 4:1 input
voltage ranges and tightly regulated output voltages even under no load conditions.
The product is available in SMD-package or in DIP-package. They work with high
efficiency over the full load range and come with a remote On/Off input.
The usability in temperature ranges of up to +85°C, continuous short circuit protec-
tion and excellent immunity against environmental influences make these converters
very reliable.
◆ 3-year product warranty
A TDR-3WI converter is the ideal solution for space critical high end applications in
communication equipment, instrumentation and industrial electronics.
Models
Order code
DIP models
Order code
SMD models
Output current
Input voltage range
Output voltage
Efficiency typ.
max.
TDR 3-1211WI
TDR 3-1211WISM
5.0 VDC
12 VDC
15 VDC
12 VDC
15 VDC
5.0 VDC
12 VDC
15 VDC
12 VDC
15 VDC
5.0 VDC
12 VDC
15 VDC
12 VDC
15 VDC
600 mA
81 %
82 %
82 %
82 %
81 %
80 %
82 %
82 %
82 %
81 %
80 %
83 %
82 %
82 %
81 %
TDR 3-1212WI
TDR 3-1213WI
TDR 3-1222WI
TDR 3-1223WI
TDR 3-2411WI
TDR 3-2412WI
TDR 3-2413WI
TDR 3-2422WI
TDR 3-2423WI
TDR 3-4811WI
TDR 3-4812WI
TDR 3-4813WI
TDR 3-4822WI
TDR 3-4823WI
TDR 3-1212WISM
TDR 3-1213WISM
TDR 3-1222WISM
TDR 3-1223WISM
TDR 3-2411WISM
TDR 3-2412WISM
TDR 3-2413WISM
TDR 3-2422WISM
TDR 3-2423WISM
TDR 3-4811WISM
TDR 3-4812WISM
TDR 3-4813WISM
TDR 3-4822WISM
TDR 3-4823WISM
250 mA
200 mA
125 mA
100 mA
600 mA
250 mA
200 mA
125 mA
100 mA
600 mA
250 mA
200 mA
125 mA
100 mA
4.5 – 18 VDC
(12 VDC nominal)
9 – 36 VDC
(24 VDC nominal)
18 – 75 VDC
(48 VDC nominal)
http://www.tracopower.com
Page 1 of 4
DC/DC Converters
TDR 3WI Series
3 Watt
Input Specifications
Input current at no load (nominal input voltage)
12 Vin models: 40 mA typ.
24 Vin models: 20 mA typ.
48 Vin models: 13 mA typ.
Input current at full load (nominal input voltage)
Surge voltage (1 sec. max.)
12 Vin models: 330 mA typ.
24 Vin models: 165 mA typ.
48 Vin models: 80 mA typ.
12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Input filter
capacitor type (see EMC considerations page 3
for compliance to EN 55022 class A/B)
ESD (electrostatic discharge)
EN 61000-4-2, air 8 kV, contact 6 kV,
perf. criteria A
Radiated immunity
EN 61000-4-3 10 V/m, perf. criteria A
Fast transient / Surge
EN 61000-4-4, 2 kV, perf. criteria A
EN 61000-4-5, 1 kV perf. criteria A
with external input capacitor e.g. Nippon
chemi-con KY 220 µF, 100 V, ESR 48 mOhm
Conducted immunity
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
Power frequency magnetic field
Reflected ripple current
12 Vin models: 80 mAp-p typ.
(measured with input filter according class A)
24 Vin models: 40 mAp-p typ.
48 Vin models: 30 mAp-p typ.
Output Specifications
Voltage set accuracy
1 % max
Regulation
– Input variation Vin min. to Vin max.
0.2 % max.
– Load variation 0 – 100 %
– Load variation 10 – 90 %
– Load cross regulation 25/100 %
single output models: 1.0 % max.
dual output models: 1.0 % max. balanced load
single output models: 0.5 % max.
dual output models: 0.8 % max. balanced load
5.0 % max. (dual output models)
Minimum load
0 % of rated max. load
0.02 %/K
Temperature coefficient
Ripple and noise (20 MHz bandwidth)
30 mVp-p typ.
Start up time
(constant resistive load)
– Power On
– Remote On
5 ms typ.
5 ms typ.
Transient response setting time (25 % load step change)
Short circuit protection
250 µs typ.
continuous, automatic recovery
Capacitive load
5 VDC models: 1680 µF max.
12 VDC models: 820 µF max.
15 VDC models: 680 µF max.
12 VDC models: 470 µF max. (each output)
15 VDC models: 330 µF max. (each output)
General Specifications
Temperature ranges
– Operating
– Storage
– Case temperature
–40°C to +85°C
–55°C to +125°C
–40°C to +100°C
Load derating
3.3 %/K above +70°C
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 4
DC/DC Converters
TDR 3WI Series
3 Watt
General Specifications
Humidity (non condensing)
5 – 95 % rel. H max.
Thermal shock
acc. MIL-STD-810F
acc. MIL-STD-810F
>5.7 Mio h
1600 VDC
Vibration
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign)
Isolation voltage (60 sec.) – Input/Output
Isolation capacitance
Isolation resistance
Altitude during operation
Safety approvals
– Input/Output
50 pF max.
>1 GOhm
– Input/Output (500 VDC)
tba.
– UL/cUL 60950-1
www.ul.com -> certifications -> File e188913
100 kHz min.
Switching frequency
Remote On/Off
– On:
open or high impedance
– Off:
2...4 mA current applied via 1KOhm resistor
2.5 mA max.
– Off stand by input current
Environmental compliance – Reach
www.tracopower.com/products/reach-declaration.pdf
RoHS directive 2011/65/EU
– RoHS
Pysical Specifications
Casing material
non-conductive plastic (UL94V-0 rated)
4.5 g (0.16oz)
Package weight
Soldering profile for DIP-package models
Lead-free reflow solder process for SMD-package models
max. 265°C / 10 sec. (wave soldering)
as per J-STD-020D.01 (to find at:
www.jedec.org - free registration required)
245°C
– Peak package body temperature
Moisture sensivity level (for SMD-package models)
level 2a as per J-STD-033B.01 (to find at:
www.jedec.org - free registration required)
Packaging
– Tube
10 pcs packing unit
200 pcs packing unit
– Tape & Reel (only SMD models, add suffix –TR)
Supporting documents: www.tracopower.com/overview/tdr3wi and www.tracopower.com/overview/tdr3wism
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 3 of 4
DC/DC Converters
TDR 3WI Series
3 Watt
Outline Dimensions
DIP-Models
Pin-Out
Pin
1
Single
Dual
–Vin (GND)
0.25 (0.01)
13.55(0.533)
–Vin (GND)
2
Remote On/Off
Remote On/Off
Common
–Vout
8.7 (0.35)
3.8
(0.15)
6
NC
NC
12.8(0.50)
7
8
9
7
6
8
+Vout
+Vout
9
–Vout
Common
+Vin (Vcc)
14
+Vin (Vcc)
NC = not to connect
2
1
14
Recommended Solder Pad
Dimension:
SMD-Models
18.1 (0.71)
0-4°
7.4 (0.29)
17.2(0.68)
1.2
(0.05)
8.7 (0.35)
12.8 (0.50)
8
9
7
6
2.0 (0.08)
2
1
Dimensions in [mm], () = Inch
Tolerances: 0.5 ( 0.02)
14
Pin pich tolerances: 0.25 ( 0.01)
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
Rev. December 11. 2017
www.tracopower.com
Page 4 of 4
相关型号:
TDR3-2411WISM
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2412
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2412SM
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2412WI
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2412WISM
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2413
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2413SM
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2413WI
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2413WISM
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2422
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2422SM
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
TDR3-2422WI
DC/DC ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER
©2020 ICPDF网 联系我们和版权申明