TDR32412WI [TRACOPOWER]

DC/DC Converters;
TDR32412WI
型号: TDR32412WI
厂家: TRACO ELECTRONIC AG    TRACO ELECTRONIC AG
描述:

DC/DC Converters

文件: 总4页 (文件大小:484K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC/DC Converters  
TDR 3WI Series, 3 Watt  
UL 60950-1  
Features  
Compact design in SMD or DIP package  
Ultra wide 4:1 input voltage range  
Fully regulated outputs  
Low ripple and noise  
No minimum load required  
Temperature range –40°C to +85°C  
I/O isolation 1500 VDC  
Continuous short-circuit protection  
Remote On/Off control  
Fully RoHS compliant  
The TDR-3WI series is a family of compact 3 W dc/dc-converters with 4:1 input  
voltage ranges and tightly regulated output voltages even under no load conditions.  
The product is available in SMD-package or in DIP-package. They work with high  
efficiency over the full load range and come with a remote On/Off input.  
The usability in temperature ranges of up to +85°C, continuous short circuit protec-  
tion and excellent immunity against environmental influences make these converters  
very reliable.  
3-year product warranty  
A TDR-3WI converter is the ideal solution for space critical high end applications in  
communication equipment, instrumentation and industrial electronics.  
Models  
Order code  
DIP models  
Order code  
SMD models  
Output current  
Input voltage range  
Output voltage  
Efficiency typ.  
max.  
TDR 3-1211WI  
TDR 3-1211WISM  
5.0 VDC  
12 VDC  
15 VDC  
12 VDC  
15 VDC  
5.0 VDC  
12 VDC  
15 VDC  
12 VDC  
15 VDC  
5.0 VDC  
12 VDC  
15 VDC  
12 VDC  
15 VDC  
600 mA  
81 %  
82 %  
82 %  
82 %  
81 %  
80 %  
82 %  
82 %  
82 %  
81 %  
80 %  
83 %  
82 %  
82 %  
81 %  
TDR 3-1212WI  
TDR 3-1213WI  
TDR 3-1222WI  
TDR 3-1223WI  
TDR 3-2411WI  
TDR 3-2412WI  
TDR 3-2413WI  
TDR 3-2422WI  
TDR 3-2423WI  
TDR 3-4811WI  
TDR 3-4812WI  
TDR 3-4813WI  
TDR 3-4822WI  
TDR 3-4823WI  
TDR 3-1212WISM  
TDR 3-1213WISM  
TDR 3-1222WISM  
TDR 3-1223WISM  
TDR 3-2411WISM  
TDR 3-2412WISM  
TDR 3-2413WISM  
TDR 3-2422WISM  
TDR 3-2423WISM  
TDR 3-4811WISM  
TDR 3-4812WISM  
TDR 3-4813WISM  
TDR 3-4822WISM  
TDR 3-4823WISM  
250 mA  
200 mA  
125 mA  
100 mA  
600 mA  
250 mA  
200 mA  
125 mA  
100 mA  
600 mA  
250 mA  
200 mA  
125 mA  
100 mA  
4.5 – 18 VDC  
(12 VDC nominal)  
9 – 36 VDC  
(24 VDC nominal)  
18 – 75 VDC  
(48 VDC nominal)  
http://www.tracopower.com  
Page 1 of 4  
DC/DC Converters  
TDR 3WI Series  
3 Watt  
Input Specifications  
Input current at no load (nominal input voltage)  
12 Vin models: 40 mA typ.  
24 Vin models: 20 mA typ.  
48 Vin models: 13 mA typ.  
Input current at full load (nominal input voltage)  
Surge voltage (1 sec. max.)  
12 Vin models: 330 mA typ.  
24 Vin models: 165 mA typ.  
48 Vin models: 80 mA typ.  
12 Vin models: 25 V max.  
24 Vin models: 50 V max.  
48 Vin models: 100 V max.  
Input filter  
capacitor type (see EMC considerations page 3  
for compliance to EN 55022 class A/B)  
ESD (electrostatic discharge)  
EN 61000-4-2, air 8 kV, contact 6 kV,  
perf. criteria A  
Radiated immunity  
EN 61000-4-3 10 V/m, perf. criteria A  
Fast transient / Surge  
EN 61000-4-4, 2 kV, perf. criteria A  
EN 61000-4-5, 1 kV perf. criteria A  
with external input capacitor e.g. Nippon  
chemi-con KY 220 µF, 100 V, ESR 48 mOhm  
Conducted immunity  
EN 61000-4-6, 10 Vrms, perf. criteria A  
Reflected ripple current  
12 Vin models: 80 mAp-p typ.  
(measured with input filter according class A)  
24 Vin models: 40 mAp-p typ.  
48 Vin models: 30 mAp-p typ.  
Output Specifications  
Voltage set accuracy  
1 % max  
Regulation  
– Input variation Vin min. to Vin max.  
0.2 % max.  
– Load variation 0 – 100 %  
– Load variation 10 – 90 %  
– Load cross regulation 25/100 %  
single output models: 1.0 % max.  
dual output models: 1.0 % max. balanced load  
single output models: 0.5 % max.  
dual output models: 0.8 % max. balanced load  
5.0 % max. (dual output models)  
Minimum load  
0 % of rated max. load  
0.02 %/K  
Temperature coefficient  
Ripple and noise (20 MHz bandwidth)  
30 mVp-p typ.  
Start up time  
(constant resistive load)  
– Power On  
– Remote On  
5 ms typ.  
5 ms typ.  
Transient response setting time (25 % load step change)  
Short circuit protection  
250 µs typ.  
indefinite, automatic recovery  
Capacitive load  
5 VDC models: 1680 µF max.  
12 VDC models: 820 µF max.  
15 VDC models: 680 µF max.  
12 VDC models:  
15 VDC models:  
470 µF max.  
330 µF max.  
General Specifications  
Temperature ranges  
– Operating  
– Storage  
– Case temperature  
–40°C to +85°C  
–55°C to +125°C  
tba.  
Load derating  
3.3 %/K above +70°C  
5 % to 90 % rel. H max.  
Humidity (non condensing)  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
http://www.tracopower.com  
Page 2 of 4  
DC/DC Converters  
TDR 3WI Series  
3 Watt  
General Specifications  
Thermal shock  
acc. MIL-STD-810F  
Vibration  
acc. MIL-STD-810F  
>2.0 Mio h  
Reliability, calculated MTBF (MIL-HDBK-217F, at+25°C, ground benign)  
Isolation voltage (60 sec.) Input/Output  
1500 VDC  
Isolation capacitance  
Isolation resistance  
Input/Output  
50 pF max.  
Input/Output (500 VDC)  
>10 GOhm  
Altitude during operation  
tba.  
Safety standard (designed to meet)  
IEC/EN 60950-1, UL 60950-1  
Safety approvals  
Switching frequency  
Remote On/Off  
– UL/cUL  
www.ul.com -> certifications -> File e188913  
100 kHz (PWM)  
On:  
open or high impedance  
Off:  
2...4 mA current applied via 1KOhm resistor  
2.5 mA max.  
Off stand by input current  
Environmental compliance – Reach  
www.tracopower.com/products/tdr3wi-reach.pdf  
RoHS directive 2011/65/EU  
– RoHS  
EMC Consideration  
L1  
Recommended filter for  
EN 55022 class A compliance  
+Vin  
-Vin  
+Vout  
TDR 3WI  
dc/dc-converter  
C1  
-Vout  
C3  
Input models C1  
C3  
L1  
value  
order code  
(SMD type)  
datasheet:  
12 VDC  
24 VDC  
48 VDC  
4.7 µF / 25 V 1812 MLCC  
4.7 µF / 50 V 1812 MLCC  
4.7 µF / 100 V 1812 MLCC  
10 µH  
12 µH  
10 µH  
TCK-047  
TCK-062  
TCK-047  
www.tracopower.com/products/tck047.pdf  
www.tracopower.com/products/tck062.pdf  
www.tracopower.com/products/tck047.pdf  
220pF / 3 kV 1808 MLCC  
L1  
Recommended filter for  
EN 55022 class B compliance  
+Vin  
+Vout  
TDR 3WI  
dc/dc-converter  
C1  
C2  
-Vin  
-Vout  
C3  
Input models C1 & C2  
C3  
L1  
value  
order code  
(SMD type)  
datasheet  
12 VDC  
24 VDC  
48 VDC  
6.8 µF / 25 V 1812 MLCC  
10 µH  
12 µH  
18 µH  
TCK-047  
TCK-062  
TCK-046  
www.tracopower.com/products/tck047.pdf  
www.tracopower.com/products/tck062.pdf  
www.tracopower.com/products/tck046.pdf  
4.7 µF / 50 V 1812 MLCC  
4.7 µF / 100 V 1812 MLCC  
220pF / 3 kV 1808 MLCC  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
http://www.tracopower.com  
Page 3 of 4  
DC/DC Converters  
TDR 3WI Series  
3 Watt  
Pysical Specifications  
Casing material  
non-conductive plastic (UL94V-0 rated)  
4.5 g (0.16 oz)  
Package weight  
Soldering profile for DIP-package models  
Lead-free reflow solder process for SMD-package models  
max. 265°C / 10 sec. (wave soldering)  
as per J-STD-020D.01 (to find at:  
www.jedec.org - free registration required)  
Moisture sensivity level (for SMD-package models)  
level 2a as per J-STD-033B.01 (to find at:  
www.jedec.org - free registration required)  
Packaging  
– Tube  
10 pcs packing unit  
200 pcs packing unit  
– Tape & Reel (only SMD models, add suffix –TR)  
Outline Dimensions  
DIP-Models  
Pin-Out  
0.25 (0.01)  
Pin  
1
Single  
–Vin (GND)  
Remote On/Off  
NC  
Dual  
–Vin (GND)  
Remote On/Off  
Common  
–Vout  
13.55(0.533)  
8.7 (0.35)  
3.8  
(0.15)  
2
12.8(0.50)  
6
8
9
7
6
7
NC  
8
+Vout  
+Vout  
9
–Vout  
Common  
+Vin (Vcc)  
14  
+Vin (Vcc)  
NC = not to connect  
2
1
14  
SMD-Models  
Recommended Solder Pad  
Dimension:  
18.1 (0.71)  
0-4°  
7.4 (0.29)  
1.2  
(0.05)  
17.2(0.68)  
8.7 (0.35)  
12.8 (0.50)  
8
9
7
6
2.0 (0.08)  
2
1
14  
Dimensions in [mm], () = Inch  
Tolerances: 0.5 ( 0.02)  
Pin pich tolerances: 0.25 ( 0.01)  
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com  
Rev. February 22. 2013  
www.tracopower.com  
Page 4 of 4  

相关型号:

TDR32413

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR32413WI

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR32422

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR32422WI

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR32423

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR32423WI

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR34811

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR34811WI

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR34812

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR34812WI

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR34813

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TDR34813WI

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER