TEQ100-4816WIR [TRACOPOWER]

DC/DC Converters;
TEQ100-4816WIR
型号: TEQ100-4816WIR
厂家: TRACO ELECTRONIC AG    TRACO ELECTRONIC AG
描述:

DC/DC Converters

文件: 总4页 (文件大小:523K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC/DC Converters  
TEQ 100WIR Series, 100 Watt  
Features  
High power block with excellent  
CB  
Scheme  
UL 60950-1  
UL 508  
thermal convection  
Operating temperature -40°C to +85°C  
without derating  
Increased shock & vibration resistance  
Ultra wide 4:1 input voltage range  
◆ꢀEN 50155 approval for railway applications  
Excellent efficiency up to 90%  
Input filter meet EN 55032, class A  
I/O isolation 2250 VDC  
Under voltage lock-out circuit  
Soft start  
Input protection filter  
up to +85°C with natural convection cooling without power derating  
and up to +95ºC with power derating. Further features include output  
voltage trimming, Remote On/Off and under voltage lockout. The  
ultra wide input voltage range and reverse input voltage protection  
make these converters also an interesting solution for battery operated  
systems.  
The TEQ-100WIR Series is a family of isolated high performance  
dc-dc converter modules with ultra-wide 4:1 input voltage ranges  
which come in a rugged, sealed metal case.  
These converters are suitable for a wide range of applications,  
but the product is designed particularly also for industrial appli-  
cations where often no PCB mounting is possible but the module  
has to be mounted on a chassis. A very high efficiency and the  
overall heatsink construction allows an operating temperature  
Models  
Order code*  
Input voltage  
Output voltage  
Output current max.  
Efficiency typ.  
TEQ 100-2412WIR  
TEQ 100-2415WIR  
TEQ 100-2416WIR  
TEQ 100-2418WIR  
TEQ 100-4812WIR  
TEQ 100-4815WIR  
TEQ 100-4816WIR  
TEQ 100-4818WIR  
TEQ 100-7212WIR  
TEQ 100-7215WIR  
TEQ 100-7216WIR  
TEQ 100-7218WIR  
12 VDC (9.6 – 13.2)  
24 VDC (19.2 – 26.4)  
28 VDC (22.4 – 30.8)  
48 VDC (38.4 – 52.8)  
12 VDC (9.6 – 13.2)  
24 VDC (19.2 – 26.4)  
28 VDC (22.4 – 30.8)  
48 VDC (38.4 – 52.8)  
12 VDC (9.6 – 13.2)  
24 VDC (19.2 – 26.4)  
28 VDC (22.4 – 30.8)  
48 VDC (38.4 – 52.8)  
8.4 A  
4.2 A  
3.6 A  
2.1 A  
8.4 A  
4.2 A  
3.6 A  
2.1 A  
8.4 A  
4.2 A  
3.6 A  
2.1 A  
90 %  
90 %  
90 %  
90 %  
90 %  
90 %  
90 %  
90 %  
89 %  
90 %  
90 %  
90 %  
10 – 36 VDC  
(24 VDC nominal)  
19 – 75 VDC  
(48 VDC nominal)  
43 – 160 VDC  
(110 VDC nominal)  
www.tracopower.com  
Page 1 of 4  
DC/DC Converters  
TEQ 100WIR Series 100 Watt  
Input Specifications  
Input current at no load  
24 Vin models: 25 mA typ.  
48 Vin models: 20 mA typ.  
110 Vin models: 10 mA typ.  
Start-up voltage  
24 Vin models: 10.0 VDC (or lower)  
48 Vin models: 19.0 VDC (or lower)  
110 Vin models: 43.0 VDC (or lower)  
Under voltage shut down (lock-out circuit)  
Surge voltage (1 sec. max.)  
24 Vin models: 8.0 VDC (or lower)  
48 Vin models: 17.0 VDC (or lower)  
110 Vin models: 37.5 VDC (or lower)  
24 Vin models: 50 V max.  
48 Vin models: 100 V max.  
110 Vin models: 185 V max.  
Conducted noise  
EMC immunity  
EN 55032 class A  
EN 50121-3-2  
– ESD (electrostatic discharge)  
EN 61000-4-2, air 8 kV, contact 6 kV,  
perf. criteria A  
– Radiated immunity  
– Fast transient / surge  
EN 61000-4-3, 20 V/m, perf. criteria A  
EN 61000-4-4, 2 kV, perf. criteria A  
EN 61000-4-5, 1 kV, perf. criteria A  
EN 61000-4-5, 2 kV, perf. criteria A  
EN 61000-4-6, 10 Vrms, perf. criteria A  
EN 50155  
– Conducted immunity  
– Railway immunity  
Reverse voltage protection  
parallel diode  
Output Specifications  
Voltage set accuracy  
Output voltage adjustment  
Regulation  
1 %  
+10 % / –20 %  
– Input variation Vin min. to Vin max.  
– Load variation (0 – 100 %)  
0.1 % max.  
0.1 % max.  
Temperature coefficient  
Minimum load  
0.02 %/K  
not required  
Remote sense  
up to Vout nom. +10%  
Ripple and noise (20 MHz Bandwidth)  
12 VDC models: 125 mVp-p max.  
24 & 28 VDC models: 250 mVp-p max.  
48 VDC models: 350 mVp-p max.  
www.tracopower.com  
Page 2 of 4  
DC/DC Converters  
TEQ 100WIR Series 100 Watt  
Output Specifications (continued)  
Start up time (nominal Vin and constant resistive load)  
Transient response (25% load step change)  
Output current limitation  
75 ms typ. (at power On or remote On)  
250 µs max.  
at 120 -150 % of Iout max.  
at 115 -130 % of Vout nom.  
hiccup, automatic recovery  
Over voltage protection  
Short circuit protection  
Capacitive load  
12 VDC models: 7‘000 µF max.  
24 VDC models: 1‘750 µF max.  
28 VDC models: 1‘280 µF max.  
48 VDC models: 430 µF max.  
General Specifications  
Temperature ranges  
– Operating  
– Storage  
–40°C to +105°C (up to +85°C w/o derating)  
–40°C to +105°C  
Thermal impedance  
Derating  
1.45°C/W  
See derating graph below  
at 110°C typ.  
Over temperature protection  
Thermal shock  
acc. MIL-STD-810F  
acc. EN61373, MIL-STD-810F  
5 % to 95 % rel H max.  
tbd.  
Shock & Vibration  
Humidity (non condensing)  
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign)  
Isolation voltage (60sec.)  
– Input/Output  
– Input/Case  
2’250 VDC (basic insulation)  
1’600 VDC  
Isolation resistance  
Switching frequency  
– Input/Output (500 VDC)  
>1 GOhm min.  
24 & 48 Vin models: 250 kHz typ. (puls width modulation)  
110 Vin models: 300 kHz typ. (puls width modulation)  
Safety standards  
Remote On/Off  
– CB test certificate  
IEC/EN 60950-1 (ed. 2), EN 60950-1:2006/  
A11:2009/A1:2010/A12:2011/A2:2013  
UL 508, CSA C22.2 No. 107.1-01  
UL 60950-1 2nd ed. +Am1  
EN50155  
– CSA certificate of compliance  
– UL online certification E188913, QQGQ2  
– Railway immunity  
– Certification documents  
www.tracopower.com/overview/teq100wir  
– positive logic (standard)  
– negative logic (option -N)  
– Off idle current:  
– On: 3 to 12 VDC or open circuit  
– Off: 0 to 1.2 VDC or short circuit terminal 1 and 4  
– On: 0 to 1.2 VDC or short circuit terminal 1 and 4  
– Off: 3 to 12 VDC or open circuit  
3 mA  
Environmental compliance – Reach document  
www.tracopower.com/info/reach-declaration.pdf  
RoHS directive 2011/65/EU  
– RoHS  
– Flammability identified acc. EN 45545-2  
www.tracopower.com/info/en45545-declaration.pdf  
Temperature derating  
120  
100  
80  
60  
40  
20  
0
Natural convection (20LFM)  
-40  
-20  
0
20  
40  
60  
80  
100  
120  
AMBIENT TEMPERATURE,TA(ºC)  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
www.tracopower.com  
Page 3 of 4  
DC/DC Converters  
TEQ 100WIR Series  
100 Watt  
Physical Specifications  
Casing material  
Potting material  
Weight  
aluminium  
silicone (UL94V-0 rated)  
800 g (28.22oz)  
Dimensions  
TEQ 100WIR module:  
103.2 (4.06)  
87.6 (3.45)  
74.2 (2.92)  
3.2 (0.13)  
DIN-Rail clip:  
Order code: TEQ-MK1  
Connection  
Terminal  
1,2  
3
Pin Function  
Recommended wire  
– Vin  
NC  
12 AWG  
NA  
45.0 (1.77)  
8.7 (0.34)  
4
Ctrl (Remote On/Off)  
+ Vin  
14 – 18 AWG  
12 AWG  
5,6  
7,8  
9
– Vout  
12 AWG  
– Sense*  
14 – 18 AWG  
14 – 18 AWG  
12 AWG  
10  
+ Sense*  
+ Vout  
11,12  
* Sense line to be connected to the output either at the module or at the load under regard of polarity.  
– The current rating of the terminal block is 15 A/pole.  
– Using 2 poles in parallel if the peak output current can exceed 15 A.  
– Wire size shall be selected to withstand the peak output current (Iout max + Current limitation).  
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com  
Rev. March 13. 2018  
www.tracopower.com  
Page 4 of 4  
www.tracopower.com  

相关型号:

TEQ100-4818WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ100-7212WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ100-7215WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ100-7216WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ100-7218WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ100WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ100WIR_18

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ160-4812WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ160-4815WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ160-4816WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ160-4818WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TEQ160-7212WIR

DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER