TEQ200-4815WIR [TRACOPOWER]
DC/DC Converters;型号: | TEQ200-4815WIR |
厂家: | TRACO ELECTRONIC AG |
描述: | DC/DC Converters |
文件: | 总4页 (文件大小:525K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC/DC Converters
TEQ 200WIR Series, 200 Watt
Features
◆ꢀHigh power block with excellent
CB
Scheme
UL 60950-1
UL 508
thermal convection
◆ꢀOperating temperature -40°C to +70°C
without derating
◆ꢀIncreased shock & vibration resistance
◆ꢀUltra wide 4:1 input voltage range
◆ꢀEN 50155 approval for railway applications
◆ Excellent efficiency up to 90%
◆ Input filter meet EN 55032, class A
◆ꢀI/O insulation 2250 VDC
◆ Under voltage lock-out circuit
◆ꢀSoft start
◆ꢀInput protection filter
up to +70°C with natural convection cooling without power derating
and up to +90ºC with power derating. Further features include output
voltage trimming, Remote On/Off and under voltage lockout. The
very wide input voltage range and reverse input voltage protection
make these converters also an interesting solution for battery operated
systems.
The TEQ-200WIR Series is a family of isolated high performance
dc-dc converter modules with ultra-wide 4:1 input voltage ranges
which come in a rugged, sealed metal case.
These converters are suitable for a wide range of applications,
but the product is designed particularly also for industrial appli-
cations where often no PCB mounting is possible but the module
has to be mounted on a chassis. A very high efficiency and the
overall heatsink construction allows an operating temperature
Models
Order code
Input voltage
Output voltage
Output current max.
Efficiency typ.
TEQ 200-4812WIR
TEQ 200-4815WIR
TEQ 200-4816WIR
TEQ 200-4818WIR
TEQ 200-7212WIR
TEQ 200-7215WIR
TEQ 200-7216WIR
TEQ 200-7218WIR
12 VDC (9.6 – 13.2)
24 VDC (19.2 – 26.4)
28 VDC (22.4 – 30.8)
48 VDC (38.4 – 52.8)
12 VDC (9.6 – 13.2)
24 VDC (19.2 – 26.4)
28 VDC (22.4 – 30.8)
48 VDC (38.4 – 52.8)
18 A
9.0 A
7.5 A
4.5 A
20 A
10 A
8.5 A
5.0 A
89 %
89 %
90 %
89 %
88 %
88 %
89 %
88 %
19 – 75 VDC
(48 VDC nominal)
43 – 160 VDC
(110 VDC nominal)
www.tracopower.com
Page 1 of 4
DC/DC Converters
TEQ 200WIR Series 200 Watt
Input Specifications
Input current at no load
48 Vin models: 23 mA typ.
110 Vin models: 13 mA typ.
Start-up voltage
48 Vin models: 19.0 VDC (or lower)
110 Vin models: 43.0 VDC (or lower)
Under voltage shut down (lock-out circuit)
Surge voltage (1 s max.)
48 Vin models: 15.8 – 17.0 VDC
110 Vin models: 34.5 – 37.5 VDC
48 Vin models: 100 V max.
110 Vin models: 185 V max.
Conducted noise
EMC immunity
EN 55032 class A
EN 50121-3-2
– ESD (electrostatic discharge)
EN 61000-4-2, air 8 kV, contact 6 kV,
perf. criteria A
– Radiated immunity
– Fast transient / Surge
EN 61000-4-3, 20 V/m, perf. criteria A
EN 61000-4-4, 2 kV, perf. criteria A
EN 55024: EN 61000-4-5, 1 kV, perf. criteria A
EN 50155: EN 61000-4-5, 2 kV, perf. criteria A
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-6, 100 A/m cont., perf. criteria A
EN 50155
– Conducted immunity
– Power frequency magnetic field
– Railway immunity
Reverse voltage protection
parallel diode
Output Specifications
Voltage set accuracy
Output voltage adjustment
Regulation
1 %
+10 % / –20 %
– Input variation Vin min. to Vin max.
– Load variation (0 – 100 %)
0.1 % max.
0.1 % max.
Temperature coefficient
Minimum load
0.02 %/K
not required
Remote sense
up to Vout nom. 10 %
Ripple and noise (20 MHz Bandwidth)
12 VDC models: 125 mVp-p max.
24 & 28 VDC models: 250 mVp-p max.
48 VDC models: 350 mVp-p max.
Start up time (nominal Vin and constant resistive load)
Transient response (25% load step change)
Output current limitation
75 ms typ. (at power On or remote On)
250 µs max.
at 120 -150 % of Iout max.
at 115 -130 % of Vout nom.
hiccup, automatic recover
Over voltage protection
Short circuit protection
Capacitive load (48Vin / 110Vin)
12 VDC models: 15‘000 / 16‘600 µF max.
24 VDC models: 3‘700 / 4‘100 µF max.
28 VDC models: 2‘600 / 3‘000 µF max.
48 VDC models: 930 / 1‘000µF max.
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
Page 2 of 4
DC/DC Converters
TEQ 200WIR Series 200 Watt
General Specifications
Temperature ranges
– Operating
– Storage
–40°C to +105°C (up to +70°C w/o derating)
–40°C to +105°C
Thermal impedance
Derating
1.45°C/W
See derating graph below
at 115°C typ.
Over temperature protection
Thermal shock
acc. MIL-STD-810F
acc. EN61373, MIL-STD-810F
5 % to 95 % rel H max.
> 270‘000 h
Shock & Vibration
Humidity (non condensing)
Reliability, calculated MTBF (MIL-HDBK-217F, at +55°C, ground benign)
Isolation voltage (60 s)
– Input/Output
– Input/Case
– Output/Case
2’250 VDC (basic insulation)
1’600 VDC
1’600 VDC
Isolation resistance
Switching frequency
Safety standards
– Input/Output (500 VDC)
> 1 GOhm min.
250 kHz typ. (puls width modulation)
– CB test certificate
IEC/EN 60950-1 (ed. 2), EN 60950-1:2006/
A11:2009/A1:2010/A12:2011/A2:2013
UL 508, CSA C22.2 No. 107.1-01
UL 60950-1 2nd ed. +Am1
– CSA certificate of compliance
– UL online certification E188913, QQGQ2
– Railway immunity
EN 50155
– Certification documents
www.tracopower.com/overview/teq200wir
Remote On/Off
– positive logic (standard)
– On: 3 to 12 VDC or open circuit
– Off: 0 to 1.2 VDC or short circuit terminal 1 and 4
3 mA
– Off idle current:
Environmental compliance – Reach document
www.tracopower.com/info/reach-declaration.pdf
RoHS directive 2011/65/EU
– RoHS
– Flammability identified acc. EN 45545-2
www.tracopower.com/info/en45545-declaration.pdf
Temperature derating
120
100
80
60
40
20
0
Natural convection (20LFM)
-40
-20
0
20
40
60
80
100
120
AMBIENT TEMPERATURE,TA(ºC)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
Page 3 of 4
DC/DC Converters
TEQ 200WIR Series
200 Watt
Physical Specifications
Casing material
Potting material
Weight
aluminium
silicone (UL94V-0 rated)
800 g (28.22oz)
Dimensions
TEQ 200WIR module:
103.2 (4.06)
87.6 (3.45)
74.2 (2.92)
3.2 (0.13)
DIN-Rail clip:
Order code: TEQ-MK1
Connection
Terminal
1,2
3
Pin Function
Recommended wire
– Vin
NC
12 AWG
NA
45.0 (1.77)
8.7 (0.34)
4
Ctrl (Remote On/Off)
+ Vin
14 – 18 AWG
12 AWG
5,6
7,8
9
– Vout
12 AWG
– Sense*
14 – 18 AWG
14 – 18 AWG
12 AWG
10
+ Sense*
+ Vout
11,12
* Sense line to be connected to the output either at the module or at the load under regard of polarity.
– The current rating of the terminal block is 15 A/pole.
– Using 2 poles in parallel if the peak output current can exceed 15 A.
– Wire size shall be selected to withstand the peak output current (Iout max + Current limitation).
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
Rev. March 13. 2018
www.tracopower.com
Page 4 of 4