THB10_17 [TRACOPOWER]

DC/DC Converters;
THB10_17
型号: THB10_17
厂家: TRACO ELECTRONIC AG    TRACO ELECTRONIC AG
描述:

DC/DC Converters

文件: 总3页 (文件大小:244K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC/DC Converters  
THB 10 Series, 10 Watt  
CB  
Scheme  
UL 60950-1  
ES 60601-1  
Features  
IEC 60950-1  
IEC 60601-1  
Supplementary and reinforced insulation  
I/O isolation 4000 VACrms rated for  
300 Vrms working voltage  
2 x MOOP Medical safety according to  
AAMI/ANSI ES 60601-1:2005(R) and  
IEC/EN 60601-1 3rd edition  
Industrial safety to UL/IEC/EN 60950-1  
Wide 2:1 input voltage ranges  
Extended operating temperature range  
–40°C to 75°C max.  
Input filter meets EN55022, class A  
Continuous short-circuit protection  
High reliability  
The THB 10 series is a range of high performance DC/DC converter modules  
with double reinforced insulation system. It complies to latest medical safety  
standard IEC 60950-1 3rd edition for MOOP (Means of Operator Protec-  
tion). The product comes in a 2”x1” industry standard package. All 12 mod-  
els features wide 2:1 input voltage range and fully regulated output voltage.  
The converters offer an economical solution for demanding applications in  
industrial and medical instrumentation.  
3-year product warranty  
Models  
Order code  
Input voltage range  
Output voltage  
Output current max.  
Efficiency typ.  
THB 10-1211  
THB 10-1212  
THB 10-1222  
THB 10-1223  
THB 10-2411  
THB 10-2412  
THB 10-2422  
THB 10-2423  
THB 10-4811  
THB 10-4812  
THB 10-4822  
THB 10-4823  
5.1 VDC  
12.0 VDC  
12.0 VDC  
15.0 VDC  
5.1 VDC  
1600 mA  
835 mA  
417 mA  
333 mA  
2000 mA  
835 mA  
417 mA  
333 mA  
2000 mA  
835 mA  
417 mA  
333 mA  
75 %  
80 %  
80 %  
81 %  
76 %  
81 %  
81 %  
82 %  
76 %  
81 %  
81 %  
82 %  
9 - 18 VDC  
(12 VDC nominal)  
18 - 36 VDC  
12.0 VDC  
12.0 VDC  
15.0 VDC  
5.1 VDC  
(24 VDC nominal)  
36 - 75 VDC  
12.0 VDC  
12.0 VDC  
15.0 VDC  
(48 VDC nominal)  
http://www.tracopower.com  
Page 1 of 3  
DC/DC Converters  
THB 10 Series  
10 Watt  
Input Specifications  
Input current at no load  
12 Vin models: 30 mA typ.  
24 Vin models: 20 mA typ.  
48 Vin models: 10 mA typ.  
Start up voltage / under voltage shutdown (hysteresis)  
long term operation with under-voltage may cause demage  
12 Vin models: 9.0 / 8.5 VDC (or lower)  
24 Vin models: 18 / 16 VDC (or lower)  
(or lower)  
48 Vin models: 36 / 34 VDC  
Recommanded external input fuse (slow blow)  
Surge voltage (1 sec. max.)  
Input filter  
12 Vin models: 3 A  
24 Vin models: 1.5 A  
48 Vin models: 0.75 A  
12 Vin models: 25 VDC max.  
24 Vin models: 50 VDC max.  
48 Vin models: 100 VDC max.  
EN 55022 class A and FCC, level A  
Output Specifications  
Voltage set accuracy  
1.0 %  
Regulation  
– Input variation Vin min. to Vin max.  
0.5 % max.  
– Load variation 15 – 100 %:  
single output models: 1.0 % max.  
dual output models: 2.0 % max. balanced load  
Minimum load  
no minimum load required  
Ripple and noise (20 MHz bandwidth)  
5 VDC models: 100 mVp-p max.  
other models: 150 mVp-p max.  
Transient Response (25% load step change)  
– Recovery time  
600 µs max.  
5.0 % max.  
– Deviation  
Current limitation  
Short circuit protection  
Capacitive load  
>120 % Iout max.  
continuous, automatic recovery  
5 VDC output models: 1000 µF max.  
12 VDC output models:  
dual output models:  
470 µF max.  
220 µF max. (each output)  
Isolation / Safety Standards  
Isolation test voltage (flash tested 1 sec.)  
I/O isolation voltage (50Hz, 60sec.)  
Leakage current (at 240VAC, 60Hz)  
I/O isolation capacity (at 100KHz, 1V)  
I/O isolation resistance (at 500VDC)  
Safety standards  
6000 Vpk  
4000 VAC  
10 µA  
80 pF max.  
>10 Gohm  
UL 60950-1, ES 60601-1 (pending)  
IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition,  
ANSI/AAMI ES60601-1 and CAN/CSA-C22.2  
No. 60601-1, Medical Electrical Equipment -  
Part 1: General Requirements for Basic Safety  
and Essential Performance  
– Certification documents  
www.tracopower.com/overview/thb10  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
http://www.tracopower.com  
Page 2 of 3  
DC/DC Converters  
THB 10 Series  
10 Watt  
General Specifications  
Temperature ranges  
– Operating  
–40°C to +75°C  
– Case  
+95°C max.  
– Storage  
–50°C to +125°C  
Derating  
2.5 %/K above 55°C  
95 % rel H max.  
Humidity (non condensing)  
Altitude during operation  
Temperature coefficient  
4000 m  
0.02 %/K typ.  
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign)  
>1’000’000 h  
Switching frequency  
Casing material  
Pin Material  
150 kHz typ. (puls width modulation)  
non conductive plastic (UL 94V-0-rated)  
copper alloy with gold plate over nickel subplate  
24.5 g (0.86 oz)  
Weight  
Soldering temperature  
max. 260°C / 10 sec.  
Outline Dimensions  
5.08  
(0.2)  
Pin-Out  
2.54  
(0.1)  
Pin  
1
Single  
+Vin (Vcc)  
-Vin(GND)  
+Vout  
Dual  
+Vin (Vcc)  
-Vin(GND)  
+Vout  
2 1  
2
3
4
No pin  
Common  
-Vout  
5
-Vout  
Bottom Viiew  
5
4
3
5.08  
(0.2)  
10.16  
(0.4)  
12.0  
20.32  
(0.8)  
(0.47)  
Dimensions in [mm], () = Inch  
Tolerances: X.X 0.5 ( 0.02)  
X.XX 0.25 ( 0.01)  
25.4  
(1.0)  
Pin diameter ø 1.0 0.05 (0.04 0.002)  
Pin pich tolerances 0.13 ( 0.005)  
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com  
Rev. May 15. 2017  
www.tracopower.com  
Page 3 of 3  

相关型号:

THB112A

暂无描述
TOKO

THB127B

Low Pass Filter
TOKO

THB3-0511

DC/DC Converters
TRACOPOWER

THB3-0512

DC/DC Converters
TRACOPOWER

THB3-0515

DC/DC Converters
TRACOPOWER

THB3-0522

DC/DC Converters
TRACOPOWER

THB3-0523

DC/DC Converters
TRACOPOWER

THB3-1211

DC/DC Converters
TRACOPOWER

THB3-1212

DC/DC Converters
TRACOPOWER

THB3-1215

DC/DC Converters
TRACOPOWER

THB3-1222

DC/DC Converters
TRACOPOWER

THB3-1223

DC/DC Converters
TRACOPOWER