AC/DC Medical Power Supply
TPP 15 Series, 15 Watt
• High power density power supply
(open frame)
• Certification according to IEC/EN/ES
60601-1 3rd edition for 2xMOPP
• Low leakage current <75 µA rated for
BF applications
• EMC emission an immunity to
IEC 60601-1-2 edition 4
• Risk management process according to
ISO 14971 including risk management file
• Acceptance criteria for electronic assem-
blies according to IPC-A-610 Level 3
• Protection class l and ll
• Operating up to 5000m altitude
CB
Scheme
prepared
ES 60601-1
UL 60950-1
• Ready to meet ErP directive,
The TPP 15 AC/DC power supplies feature a reinforced double I/O isolation sys-
tem according to medical safety standards IEC/EN/ES 60601-1 3rd edition for
2 x MOPP approved for an operating altitude of 5000 m. The earth leakage
current is below 75 μA what makes the units suitable for BF (body floating) ap-
plications. The eꢀcellent efficiency of up to 88.5% offers a high power density
in the packaging format 1.0” ꢀ 2.6”. The full load operating temperature range
covers –40°C to +55°C while it goes up to 85°C with 50% load derating. The
units operate in compliance to the medical EMC emission and immunity levels
according to latest standard IEC 60601-1-2 4th edition.
no load power consumption
• 5 year product warranty
Models
Order Code
Output Power
(max.)
Output Voltage
Output Current
(max.)
Efficiency
(typ.)
TPP 15-103A-J
TPP 15-105A-J
TPP 15-109A-J
TPP 15-112A-J
TPP 15-115A-J
TPP 15-124A-J
TPP 15-136A-J
TPP 15-148A-J
13.2 W
3.3 VDC
5.0 VDC
9.0 VDC
12 VDC
15 VDC
24 VDC
36 VDC
48 VDC
4‘000 mA
3‘000 mA
1‘670 mA
1‘250 mA
1‘000 mA
625 mA
84.0 %
86.0 %
86.0 %
87.0 %
87.0 %
88.0 %
88.0 %
88.5 %
15 W
417 mA
313 mA
http://www.tracopower.com
Page 1 of 3
TPP 15 Series, 15 Watt
Input Specifications
Input voltage range
– AC range (universal input)
– DC range
85 – 264 VAC
(derating of 4%/V below 90 VAC input required)
120 – 370 VDC
Input frequency
47 – 63 Hz
Input current at full load
Input protection
– at 115 VAC / 230 VAC
0.45 A maꢀ. / 0.30 A maꢀ.
T1.6 A/250 VAC
(internal fuse in both line & neutral)
Input inrush current
– at 230 VAC
40 A maꢀ.
Zero load power consumption
0.05 W maꢀ. (acc. ErP directive)
Output Specifications
Voltage adjustability
10%
1%
Voltage set accuracy
Regulation
– Input variation
0.2% maꢀ.
– Load variation (0 - 100%)
3.3 & 5 VDC model: 0.7% maꢀ.
other models: 0.5% maꢀ.
not required
0.02%/K
Minimum load
Temperature coefficient
Hold-up time
– Vin = 115 VAC
8 ms typ.
Start-up time
500 ms maꢀ.
20 ms typ.
Rise time
Ripple and noise
(20Mhz Bandwidth)
- single output model
3.3 & 5.0 VDC outputs: 40 mVp-p typ. w. cap. 10µF/50V 1206 X5R MLCC
9, 12 & 15 VDC output: 70 mVp-p typ. w. cap. 10µF/50V 1206 X5R MLCC
24 & 36 VDC output: 100 mVp-p typ. w. cap. 10µF/50V 1206 X5R MLCC
48 VDC output: 140 mVp-p typ. w. cap. 1µF/100V 1206 X7R MLCC
Transiente response
– Peak deviation
– Recovery time
5% maꢀ. (25% load step change)
500 µs typ.
Overvoltage protection
Current limitation
125 – 140% of nominal Vout
at 145% Iout typ.
Short circuit protection
continuous (automatic recovery), hiccup
General Specifications
Temperature ranges
– Operating
–40°C to +85°C with derating
– Storage
–40°C to +85°C
Output power derating
– Temperature
1.67 %/K above +55°C (up to 85°C max.)
– Low input voltage
4.0 %/V below 90 VAC
Humidity (non condensing)
5 – 95 % rel. H maꢀ.
5000 m
Altitude during operation
Switching frequency (at 230 VAC)
85 kHz typ. ( 10 kHz) (pulse width modulation)
4000 VAC (2 ꢀ MOPP insulation)
75 µA maꢀ.
Isolation voltage
– Input / Output (60 sec.)
Leakage current (at 264 VAC/60Hz)
Isolation resistance (at 500 VDC)
Reliability
100 Mohm min.
– calculated MTBF at +25°C acc. to MIL-HDBK-217F
3‘000‘000 h
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3
TPP 15 Series, 15 Watt
General Specifications (continued)
EMI emission
– Conducted & Radiated input surpression
EN 55011 limits to IEC 60601-1-2 4th editon
EN 55032 class B (internal filter)
IEC / EN 61000-3-2, class A
– Harmonic current emissions
– Voltage flicker
IEC / EN 61000-3-3, (class tba.)
EMC immunity
EN 55024, EN 60601-1-2 4th edition
EN 61000-4-2, air 15 kV, contact 8 kV,
perf. criteria A
– ESD (electrostatic discharge)
– Radiated immunity
– Fast transient
– Surge
– Conducted immunity
– Magnetic field immunity
– Voltage dip and interruptions
EN 61000-4-3, 20 V/m, perf. criteria A
EN 61000-4-4, 2 kV, perf. criteria A
EN 61000-4-5, 1 kV perf. criteria A
EN 61000-4-6, 20 Vrms, perf. criteria A
EN 61000-4-8, 30 A/m, perf. criteria A
EN 61000-4-11,
Safety standards and certification
UL 60950-1, IEC/EN 60950-1,
IEC/EN 60601-1 3rd edition,
ANSI/AAMI ES60601-1:2005(R)2012
www.tracopower.com/overview/tpp15
– Certification documents
Shock and vibration
Vibration acc. IEC 60068-2-6
Shock acc. IEC 60068-2-27
Environmental compliance – Reach
www.tracopower.com/products/reach-declaration.pdf
RoHS directive 2011/65/EU
– RoHS
Protection class
Connection
class I & II prepared
pin connector
Outline Dimensions
Each one of the 4 srew holes can be used
as a PE connection for class I applications
Print thickness: 1.0 mm (0.04 inch)
Front View
Pin connectors
Input
Single
Output
Dual
Pin
1
Pin
1
3.2 (0.13)
Line
–Vout
+Vout
3
2
Neutral
Input: JST series
mates with JST crimp terminal: BVH-21T-P1.1
and terminal housing: VHR-3N
Output: JST series
mates with JST crimp terminal: BVH-21T-P1.1
and terminal housing: VHR-2N
2.92 (0.11)
3.35 (0.13)
59.5 (2.34)
66.2 (2.61)
Dimension in mm, () = inch
Tolerances: x.x 0.5 ( 0.02)
x.xx 0.25 ( 0.01)
Weight: 19.0g (0.67 oz)
©
Copyright 2017 Traco Electronic AG
Specifications can be changed without notice!
Rev. August 18, 2017