F16-1250 [TRIAD]

Split Bobbin Power Transformer, 20VA, ROHS COMPLIANT;
F16-1250
型号: F16-1250
厂家: TRIAD MAGNETICS    TRIAD MAGNETICS
描述:

Split Bobbin Power Transformer, 20VA, ROHS COMPLIANT

变压器
文件: 总1页 (文件大小:66K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
P O W E R T R A N S F O R M E R  
P C M O U N T : SPLIT PACK  
F16-1250  
Description:  
The F16-1250 is a single primary and dual secondary, split bobbin design which  
operates with an input of 115V. The output voltage will be either 16.0V with a  
center-tap under a 1.25A load with the secondaries wired in series, or 8.0V under  
a 2.5A load with the secondaries wired in parallel. The split bobbin design  
eliminates the need for costly electrostatic shielding.  
Electrical Specifications (@25C)  
1. Maximum Power: 20.0VA  
2. Primary:  
115V, 50/60 Hz  
3. Secondary: Series: 16.0V CT@ 1.25A  
Parallel: 8.0V @ 2.5A  
W
4. Voltage Regulation: 25% TYP @ full load to no load  
5. Temperature Rise: 25C TYP  
6. Hipot tested 100% at 2500 VRMS  
Construction:  
Three flange bobbin construction with primaries and secondaries wound side by  
side for low capacitive coupling.  
Agency File:  
E
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,  
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,  
Canadian Use (CSA 22.2, No.66.2-06)  
L
This model is also available in Class 2, UL 5085-3 (1585) version as F16-1250-C2  
H
Dimensions:  
Units in inches.  
H
W
L
A
B
C
D
E
F
1
4
1.437 1.875  
2.25  
0.300 0.400 1.600 0.041 0.020 0.234  
Weight: 0.80 lbs  
D
F
Schematic:  
5
A
A
1
5
8
115V  
6
7
50/60Hz  
B
4
8
C
RoHS Compliance: As of manufacturing date February 2005, all standard products  
meet the requirements of 2011/65/EU, known as the RoHS initiative.  
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2  
and 5085-3, respectively.  
1
4
0.06" DIAMETER  
HOLE  
*Upon printing, this document is considered “uncontrolled”. Please contact Triad  
Magnetics website for the most current version. For soldering and washing information  
please see http://www.triadmagnetics.com/faq.html  
Board Layout  
Web: www.TriadMagnetics.com  
Phone 951-277-0757  
Fax 951-277-2757  
460 Harley Knox Blvd.  
Perris, California 92571  
Publish Date: June 7, 2016  

相关型号:

F16-1250-C2

Split Bobbin Power Transformer, 20VA, ROHS COMPLIANT
TRIAD

F16-150

Split Bobbin Power Transformer, 2.5VA, ROHS COMPLIANT
TRIAD

F16-150-C2

Split Bobbin Power Transformer,
TRIAD

F16-2250

Split Bobbin Power Transformer, 36VA, ROHS COMPLIANT
TRIAD

F16-2250-C2

Split Bobbin Power Transformer, 36VA, ROHS COMPLIANT
TRIAD

F16-400

Split Bobbin Power Transformer, 6VA, ROHS COMPLIANT
TRIAD

F16002

~50° wide beam compatible with LEDiL HEKLA
LEDIL

F16002_18

~50° wide beam compatible with LEDiL HEKLA
LEDIL

F16007

~90° wide beam
LEDIL

F16007_18

~90° wide beam
LEDIL

F1600DC45

Standard SRAM, 64KX1, 45ns, CMOS, CDIP22, 0.300 INCH, SIDE BRAZED, DIP-22
FAIRCHILD

F1600DC55

Standard SRAM, 64KX1, 55ns, CMOS, CDIP22, 0.300 INCH, SIDE BRAZED, DIP-22
FAIRCHILD