BTB12AG-6-CW-TA3-T [UTC]

12A TRIACS;
BTB12AG-6-CW-TA3-T
型号: BTB12AG-6-CW-TA3-T
厂家: Unisonic Technologies    Unisonic Technologies
描述:

12A TRIACS

三端双向交流开关
文件: 总4页 (文件大小:170K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
UNISONIC TECHNOLOGIES CO., LTD  
BTB12A  
Preliminary  
TRIAC  
12A TRIACS  
DESCRIPTION  
The UTC BTB12A is a 12A triacs which can be operated in 3  
quadrants, it uses UTC’s advanced technology to provide customers  
with high commutation performances.  
The UTC BTB12A is suitable for inductive load switching operations,  
also can be used in ON/OFF function applications such as induction  
motor starting circuits, heating regulation, static relays etc.  
SYMBOL  
ORDERING INFORMATION  
Ordering Number  
Pin Assignment  
Package  
TO-220  
Packing  
Tube  
Lead Free  
Halogen Free  
BTB12AG-x-xx-TA3-T  
1
2
3
BTB12AL-x-xx-TA3-T  
MT1 MT2  
G
SENSITIVITY AND TYPE  
VOLTAGE  
PART NUMBER  
SENSITIVITY  
TYPE  
600V  
800V  
BW  
CW  
SW  
TW  
50mA  
35mA  
10mA  
5mA  
SNUBBERLESS  
SNUBBERLESS  
LOGIC LEVEL  
LOGIC LEVEL  
: Available  
MARKING  
www.unisonic.com.tw  
1 of 4  
Copyright © 2014 Unisonic Technologies Co., Ltd  
QW-R401-056.b  
BTB12A  
Preliminary  
TRIAC  
ABSOLUTE MAXIMUM RATINGS  
PARAMETER  
SYMBOL  
IT(RMS)  
RATINGS  
12  
UNIT  
A
RMS On-State Current (Full Sine Wave) TC=90°C  
Non Repetitive Surge Peak  
F=50 Hz  
t=20ms  
120  
A
On-State Current (Full Cycle,  
TJ initial=25°C)  
ITSM  
I2t  
F=60 Hz  
tP=10ms  
t=16.7ms  
126  
78  
A
A2s  
I2t Value for Fusing  
Critical Rate of Rise of  
On-State Current IG=2xIGT  
,
F=120 Hz TJ=125°C  
dI/dt  
50  
A/µs  
tr100ns  
Non Repetitive Surge Peak  
Off-State Voltage  
tP=10ms  
tP=20µs  
TJ=25°C  
VDSM/VRSM  
VDRM/VRRM+100  
V
Peak Gate Current  
TJ=125°C  
TJ=125°C  
IGM  
PG(AV)  
TJ  
4
A
Average Gate Power Dissipation  
Operating Junction Temperature  
Storage Junction Temperature  
1
W
°C  
°C  
-40~+125  
-40~+150  
TSTG  
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.  
Absolute maximum ratings are stress ratings only and functional device operation is not implied.  
THERMAL RESISTANCES  
PARAMETER  
SYMBOL  
θJA  
RATINGS  
UNIT  
°C/W  
°C/W  
Junction to Ambient  
60  
Junction to Case (AC)  
θJC  
1.4  
ELECTRICAL CHARACTERISTICS (TJ =25°C unless otherwise specified)  
FOR SNUBBERLESS TYPE and LOGIC LEVEL TYPE (3 QUADRANTS  
TW  
SW  
CW  
BW  
TEST  
CONDITIONS  
PARAMETER SYMBOL  
Gate Trigger  
UNIT  
MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX  
Current  
(Note 1)  
IGT  
VGT  
VGD  
I-II-III  
5
10  
35  
50 mA  
VD=12V,  
RL=30Ω  
Gate Trigger  
Voltage  
I-II-III  
1.3  
1.3  
1.3  
1.3  
V
V
Gate  
Non-Trigger  
Voltage  
VD=VDRM,  
RL=3.3k, I-II-III 0.2  
0.2  
0.2  
0.2  
TJ=125°C  
Holding Current  
(Note 2)  
IH  
IL  
IT=100mA  
10  
15  
35  
50 mA  
I-III  
10  
15  
25  
30  
50  
60  
70 mA  
80 mA  
Latching  
Current  
IG=1.2IGT  
II  
Critical Rate of  
Rise of  
VD=67%VDRM  
,
Off-State  
Voltage  
dV/dt Gate Open,  
TJ=125°C  
20  
40  
500  
V/μs  
1000  
(Note 2)  
(dV/dt)c=0.1V/µs,  
TJ=125°C  
Critical Rate of  
Rise of  
Off-State  
Voltage at  
Commutation  
(Note 2)  
3.5  
1
6.5  
2.9  
(dI/dt)c (dV/dt)c=10V/µs,  
TJ=125°C  
A/ms  
Without Snubber  
TJ=125°C  
6.5  
12  
Notes: 1. Minimum IGT is guaranteed at 5% of IGT max.  
2. For both polarities of MT2 referenced to MT1.  
UNISONIC TECHNOLOGIES CO., LTD  
2 of 4  
QW-R401-056.b  
www.unisonic.com.tw  
BTB12A  
Preliminary  
TRIAC  
STATIC CHARACTERISTICS  
PARAMETER  
SYMBOL  
VT  
TEST CONDITIONS  
MIN TYP MAX UNIT  
Peak On-State Voltage(Note)  
Threshold Voltage(Note)  
Dynamic Resistance(Note)  
ITM=17A, tp=380μs  
TJ=25°C  
TJ=125°C  
TJ=125°C  
TJ=25°C  
TJ=125°C  
1.55  
0.85  
35  
V
V
VTO  
RD  
mꢀ  
μA  
mA  
IDRM  
IRRM  
5
Repetitive Peak Off-State Current  
VDRM=VRRM  
1
Note: 1. Minimum IGT is guaranteed at 5% of IGT max.  
2. For both polarities of MT2 referenced to MT1.  
UNISONIC TECHNOLOGIES CO., LTD  
3 of 4  
QW-R401-056.b  
www.unisonic.com.tw  
BTB12A  
Preliminary  
TRIAC  
UTC assumes no responsibility for equipment failures that result from using products at values that  
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or  
other parameters) listed in products specifications of any and all UTC products described or contained  
herein. UTC products are not designed for use in life support appliances, devices or systems where  
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in  
whole or in part is prohibited without the prior written consent of the copyright owner. The information  
presented in this document does not form part of any quotation or contract, is believed to be accurate  
and reliable and may be changed without notice.  
UNISONIC TECHNOLOGIES CO., LTD  
4 of 4  
QW-R401-056.b  
www.unisonic.com.tw  

相关型号:

UTC
UTC
UTC
UTC
UTC
UTC
UTC
UTC
UTC
UTC
UTC
UTC