UTCLM8560 [UTC]

MOS IC; MOS IC
UTCLM8560
型号: UTCLM8560
厂家: Unisonic Technologies    Unisonic Technologies
描述:

MOS IC
MOS IC

文件: 总9页 (文件大小:177K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
UTC LM8560  
MOS IC  
DIGITAL ALARM CLOCK  
DESCRIPTION  
The LM8560 is alarm equipped digital clock IC with built-in  
driver capable of directly driving LED display equipment. As IC  
himself the VDD pin for the LM8560 is graded to withstand a  
voltage of 15V.  
FEATURES  
*Single chip P-channel ED MOS LSI  
*LED direct drive using time division (duplex configuration)  
*Wide operating power supply voltage range  
*Built-in alarm function with 24-hour control  
*Supports changeover between 12-hour AM/PM and 24-hour  
displays  
SDIP-28  
*Built-in battery backup CR oscillator  
*Users 50Hz or 60Hz as standard frequency  
*Built-in automatic fast forward function for hour and minute  
settings  
*Built-in sleep timer function (maximum intervals of 59 minutes  
or 1 hours and 59 minutes)  
*Built-in snooze function supporting repeat use  
*Equipped with power failure display function  
*900Hz output for alarm tone  
FUNCTIONS  
*Current time display  
*Snooze alarm function  
*Sleep timer function (maximum intervals of 59 minutes or 1  
hours and 59 minutes)  
APPLICATIONS  
*Alarm clocks  
*Clock radios  
UTC UNISONIC TECHNOLOGIES CO., LTD.  
1
QW-R502-005,D  
UTC LM8560  
MOS IC  
PIN CONFIGURATIONS  
AM& 10'S HR  
ag&de  
28  
27  
1
2
12/24 HR Select  
CR Input  
PM& 10'S HR b  
26  
25  
24  
50/60 Hz Select  
50/60 Hz Input  
Snooze Input  
Sleep Display  
Hour Set  
3
4
10'S HR c& HR e  
HR b&g  
HR c&d  
HR a&f  
5
6
23  
22  
21  
10'S MIN a&f  
10'S MIN b&g  
7
8
LM8560  
Minute Set  
20  
19  
9
VDD  
10'S MIN c&d  
10'S MIN e &Min e  
MIN b&g  
Alarm Display  
10  
11  
18 Alarm OFF  
17  
MIN c&d  
MIN a&f  
12  
13  
Sleep Output  
16  
15  
Alarm Output  
VSS  
14  
Colon Output  
ABSOLUTE MAXIMUM RATINGS (Ta=25°C, Vss=0V)  
PARAMETER  
Maximum Supply Voltage  
Input Voltage1  
SYMBOL  
VDD (max)  
VIN1  
TEST CONDITIONS  
RATING  
-15~ +0.3  
-15~ +0.3  
-15~ +0.3  
-15~ +0.3  
-0.4 ~+0.4  
700  
UNIT  
V
V
V
V
mA  
mW  
°C  
°C  
50/60Hz Input  
Except 50/60Hz Input  
Input Voltage2  
VIN2  
Output Voltage  
VOUT  
lIN  
PD (max)  
Topr  
Tstg  
Input Clamp Current  
Allowable Power Dissipation  
Operating Temperature  
Storage Temperature  
50/60Hz Input  
Ta=70°C  
-30 ~ +70  
-55 ~ +125  
ALLOWABLE OPERATING RANGES (Ta=25°C, Vss=0V )  
PARAMETER  
Supply Voltage  
SYMBOL  
VDD  
TEST CONDITIONS  
MIN.  
-14  
-1  
TYP. MAX.  
UNIT  
-7.5  
V
V
V
V
V
V
Input “H” Level Voltage1  
Input “L” Level Voltage1  
Input “H” Level Voltage2  
Input “L” Level Voltage2  
50/60Hz Input Pin Input  
Voltage  
VIH1  
VIL1  
VIH2  
VIL2  
50/60Hz Input  
50/60Hz Input  
Except 50/60Hz Input  
Except 50/60Hz Input  
VDD+2  
VDD+2  
-1.5  
VAC-IN Sets VSS as Reference  
VLED  
UTC UNISONIC TECHNOLOGIES CO., LTD.  
2
QW-R502-005,D  
UTC LM8560  
MOS IC  
ELECTRICAL CHARACTERISTICS (Ta=25°C, VDD=-12V unless otherwise specified)  
PARAMETER  
SYMBOL  
IIH1  
TEST CONDITIONS  
50/60Hz Input, VIN=VSS  
MIN.  
TYP. MAX.  
UNIT  
µA  
Input “H” Level Current 1  
Input “L” Level Current 1  
Input “H” Level Current 2  
10  
10  
20  
IIL1  
50/60Hz Input, VIN=VDD  
Input Pins Other Than 50/60Hz Input  
VIN=VSS  
µA  
IIH2  
µA  
Input “L” Level Current 2  
Output “H” Level Current 1  
Output Leakage Current 1  
Output “H” Level Current 2  
Output Leakage Current 2  
Output “H” Level Current 3  
Output Leakage Current 3  
IIL2  
IOH1  
IOF1  
IOH2  
IOF2  
IOH3  
IOF3  
VDD  
ICC  
Input Pins Other Than 50/60Hz Input  
10  
10  
20  
µA  
mA  
µA  
mA  
µA  
mA  
µA  
V
VIN=VDD  
Alarm Output and Sleep Output  
VOH=VSS-1V  
Alarm Output and Sleep Output  
VOUT=VDD  
AM & 10’S HR ag & de (24H mode)  
VOUT=VDD-1V  
AM & 10’S HR ag & de (24H mode)  
VOUT=VDD  
Segment Output Other Than Those  
VOUT=VSS-1V  
Segment Output Other Than Those  
Listed Above, VOUT=VDD  
5
36  
18  
20  
Power failure detection  
Voltage  
Consumption Current  
-7.5  
-5  
Output set to off and Pull-down attached  
input set open  
Standard Value,900Hz,  
VDD=-9V±10%-10  
5
7
mA  
%
Backup Oscillator Stability  
Factor  
Backup Oscillator  
Accuracy  
FS  
-10  
-10  
10  
10  
FA  
Standard Value,900Hz, VDD=-9V-10  
%
DESCRIPTION OF OPERATIONS  
*50/60Hz Input:  
Built-in Shumidt circuit enables noise eliminations at 50/60Hz commercial frequencies with use of a  
simple CR filter. Built-in pull-up resistor.  
*CR Input:  
When the AC power supply is interrupted, the time counter switches to a holding state and a built-in  
oscillator promptly begins operation. If 50/60Hz input continues for 3 clocks without arriving, this  
oscillator’s output is activated and functions as the time counter clock in place of 50/60Hz input. The  
frequency level of this clock oscillator is determined according to the CR value. While the above  
mentioned oscillator is operating using backup mode, all segment output is switched to OFF.  
(Note) When the backup oscillator is in use due to an AC power supply interruption, the 50/60Hz input  
pin must be maintained open or at a VSS level.  
*50/60 Selective Input:  
When 50/60 selective input is connected to VSS, 50Hz use is enabled. When 50/60 selective input is  
left open, VDD is activated using an internal pull-down resistor and the setting is switched to enable use  
at 60Hz.  
*Display Mode Selective Input (Alarm Select/Sleep Select):  
Since the pull-down resistor is built-in , selection from four display modes is possible using two SPST  
switches (single-pole and single-throw switches). Table 1 shows these display mode selections.  
UTC UNISONIC TECHNOLOGIES CO., LTD.  
3
QW-R502-005,D  
UTC LM8560  
MOS IC  
Table1 Display Modes  
Selective lnput  
Display Mode  
Time display  
Alarm display  
Sleep display  
Second display  
Digit No. 1  
Digit No. 2  
Hour  
Digit No. 3  
Digit No.4  
Minute  
Alarm  
Sleep  
10’s place for  
hour, AM/PM  
10’s place for  
hour, AM/PM  
10’s place for  
Minute  
NC  
NC  
10’s place for  
VSS  
NC  
NC  
VSS  
VSS  
Hour  
Hour  
Minute  
Minute  
Second  
Minute  
10’s place for  
Minute  
10”s place for  
Clear  
VSS  
Clear  
Minute  
Second  
Note: Activating VSS using two inputs simultaneously (alarm select and sleep select), the display mode is switched to  
display seconds.  
*Time Setting Input:  
There are two setting inputs for use with “hour” and “minute”. Time content settings show in Table2 are  
possible by activating VSS to these pins, A pull-down resistor is built-in.  
Table2 Setting contents  
Display Mode  
Time  
Set Input  
Hour  
Functions  
Immediately adds 1 to hour digits and then assigns an additional 1, at a  
speed of 2 Hz, after each 1/4 to 3/4 second.  
Min  
Immediately adds 1 to minute digits and then assigns an additional 1, at a  
speed of 2 Hz, after each 1/4 to 3/4 second. Seconds are rest.  
Operates both as outline above.  
Second digits are cleared to [00].  
Time holds.  
Both  
Hour (note1)  
Min  
Second  
(Alarm & Sleep)  
Both (note2)  
Resets hour and minute digits as [0:00] when operating in 24-H mode or  
[12:00] when operating in 12-H mode.  
Alarm  
Sleep  
Hour  
Min  
Immediately adds 1 to hour digits and then assigns an additional 1, at a  
speed of 2 Hz, after each 1/4 to 3/4 second.  
Immediately adds 1 to minute digits and then assigns an additional 1, at a  
speed of 2 Hz, after each 1/4 to 3/4 second.  
Resets hour and minute digits as [0:00] when operating in 24-hour mode or  
[12:00] when operating in 12-hour mode.  
Sets sleep counter to [0:59] instantly when VDD is activated to sleep select  
Sets Sleep counter to [1:59] instantly when VDD is activated to sleep select  
and hour at the same time.  
Both  
-
Hour  
Min  
Both  
Sleep counter looses 1 at a speed of 2 Hz.  
Sleep counter looses 1 at a speed of 2 Hz.  
Note:1.Once conditions have been switched to reset or hold, input of other functions is locked until both Hour and  
Min input have been separated.  
2.When the digital reading for seconds is between 30 and 59 seconds, 1 is added to the digits for minutes as  
he digital reading for seconds rests to [00].  
*12/24H Select Input  
:
When this pin set open (VDD), a 12-hour display is enabled whereas connecting this pin to VSS enables  
the 24-hour display. A pull-down resistor is build-in.  
*Power Failure Detection Display  
:
UTC UNISONIC TECHNOLOGIES CO., LTD.  
4
QW-R502-005,D  
UTC LM8560  
MOS IC  
When activated by drop in power supply, all segments which are lit begin to blink and the unit switches  
to a power failure detection display. The power failure detection display is canceled by activating VSS to  
Hours set or Min set.  
*Alarm Operation and Alarm Output  
:
The alarm signal outputs when alarm content matches the content of current time. When not rest by  
either snooze input or alarm off input, output continues after 1 hour and 59 minutes. This output signal  
consists of 900Hz 2Hz intermittent (50% duty) modulation signals, When the need arises , a filter can be  
applied to after the alarm signal to a DC signal.  
*Snooze Input  
:
When the alarm is sounding and instantly activating VSS to this pin , alarm output is set to OFF for a  
period between 8 and 9 minutes after which time the alarm signal is once again output. The snooze  
function can be used repeatedly in 1 hours and 59 minutes intervals. A pull-down resistor is built-in  
Activating VSS to the snooze pin when the alarm is OFF resets the sleep timer counter to [0:00 ](This is  
known as the one-touch sleep timer reset function.)  
*Alarm Off Input :  
Activating this input pin to VSS instantly sets alarm output to OFF.A pull-down resistor is built-in.  
*Sleep Timer and Sleep Output :  
Sleep output can turn on the radio and can be set for time intervals of 59 minutes or 1 hour and 59  
minute. Refer to Table 2 for the proper selection procedure (59 minutes or 1 hour and 59 minute  
selection.) This sleep timer is constructed using a down counter and when the counter content arrives at  
[00], output is set to off and the radio turns off. Adding VSS to snooze input turns sleep output off. When  
sleep output is on.  
UTC UNISONIC TECHNOLOGIES CO., LTD.  
5
QW-R502-005,D  
UTC LM8560  
MOS IC  
BLOCK DIAGRAM  
Output Decoder/Driver  
Second  
Display  
PWR UP  
UTC UNISONIC TECHNOLOGIES CO., LTD.  
6
QW-R502-005,D  
UTC LM8560  
MOS IC  
CLOCK-RADIO APPLICATION CIRCUIT (Positive Power Supply)  
+
UTC UNISONIC TECHNOLOGIES CO., LTD.  
7
QW-R502-005,D  
UTC LM8560  
MOS IC  
CLOCK APPLICATION CIRCUIT (Negative Power Supply)  
UTC UNISONIC TECHNOLOGIES CO., LTD.  
8
QW-R502-005,D  
UTC LM8560  
MOS IC  
UTC assumes no responsibility for equipment failures that result from using products at values that  
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or  
other parameters) listed in products specifications of any and all UTC products described or contained  
herein. UTC products are not designed for use in life support appliances, devices or systems where  
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in  
whole or in part is prohibited without the prior written consent of the copyright owner. The information  
presented in this document does not form part of any quotation or contract, is believed to be accurate  
and reliable and may be changed without notice.  
UTC UNISONIC TECHNOLOGIES CO., LTD.  
9
QW-R502-005,D  

相关型号:

UTCLMV358

GENERAL PURPOSE, LOW VOLTAGE, RAIL-TO-RAIL OUTPUT OPERATIONAL AMPLIFIERS
UTC

UTCLP2950

100 mA LOW-DROPOUT VOLTAGE REGULATOR
UTC

UTCLP2951

100 mA LOW-DROPOUT VOLTAGE REGULATOR
UTC

UTCM2100

SINGLE OPERATIONAL AMPLIFIER
UTC

UTCM2110

LINEAR INTEGRATED CIRCUIT
UTC

UTCM2115

LINEAR INTEGRATED CIRCUIT
UTC

UTCM2904

LINEAR INTEGRATED CIRCUIT
UTC

UTCM2950-2.5

250 mA LOW-DROPOUT VOLTAGE REGULATOR
UTC

UTCM2950-3.0

250 mA LOW-DROPOUT VOLTAGE REGULATOR
UTC

UTCM2950-3.3

250 mA LOW-DROPOUT VOLTAGE REGULATOR
UTC

UTCM2950-3.6

250 mA LOW-DROPOUT VOLTAGE REGULATOR
UTC

UTCM2950-5.0

250 mA LOW-DROPOUT VOLTAGE REGULATOR
UTC