EX-245 [VECTRON]
Hi-Reliability Evacuated Miniature Crystal Oscillator; 嗨,可靠性真空管微型晶体振荡器型号: | EX-245 |
厂家: | Vectron International, Inc |
描述: | Hi-Reliability Evacuated Miniature Crystal Oscillator |
文件: | 总6页 (文件大小:430K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
EX-245
Hi-Reliability Evacuated Miniature Crystal Oscillator
EX-245
Features
Typical Applications
Severe Environmental Conditions
16 pin Double Dip Package
Ruggedized hybrid thick film construction
Low Power Consumption
Frequency Range
10 MHz – 40 MHz
10, 20 MHz
Standard Frequencies
Frequency stabilities1 [10 to 20 MHz]
Parameter
Min
-50
Typ
Typ
Max
+50
Units
ppb
Operating temp range
0 … +60°C
vs. operating temperature range
(Referenced to +25°C)
-75
+75
ppb
-20 … +70°C
-40 … +85°C
Condition
-100
Min
+100
Max
ppb
Parameter
Units
Initial tolerance For Fixed Freq.
Settability
-1
-0.2
-15
-15
-2
-200
-1000
-1500
-2000
+1
+0.2
+15
+15
+2
+200
+1000
+1500
+2000
ppm
ppm
ppb
ppb
ppb
ppb
ppb
ppb
ppb
Fixed, no adjust option
vs. supply voltage change
vs. load
VS ± 5%
Load ± 5%
after 7 days of operation
vs. aging / day
vs aging / 1 year
vs. aging /10 year
vs. aging /10 year
vs. aging /10 year
10 to <12MHz
12 to <16MHz
16 to 20MHz
120
180
seconds
seconds
to ± 1ppm of final freq. @+25°C
to ± 100ppb of final freq. @+25°C
Warm-up Time
http://www.vectron.com Rev. 02-06-09 daf
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
Frequency stabilities1 [>20 to 40 MHz]
Parameter
Min
-75
Typ
Max
+75
Units
ppb
Operating temp range
0 … +60°C
vs. operating temperature range
(Referenced to +25°C)
-100
-150
Min
+100
+150
Max
ppb
-20 … +70°C
-40 … +85°C
Condition
ppb
Parameter
Typ
Units
Initial tolerance For Fixed Freq.
Settability
-1.5
-0.3
-25
-25
-3
+1.5
+0.3
+25
+25
+3
ppm
ppm
ppb
ppb
ppb
ppb
ppb
Fixed, no adjust option
vs. supply voltage change
vs. load
VS ± 5%
Load ± 5%
after 7 days of operation
vs. aging / day
vs aging / 1 year
vs. aging /10 year
-300
-3000
+300
+3000
120
180
seconds
seconds
to ± 1ppm of final freq. @+25°C
to ± 100ppb of final freq. @+25°C
Warm-up Time
Supply Voltage (Vs)
Parameter
Min
4.75
Typ
Max
Units
VDC
Condition
Supply voltage [Standard]
Power consumption
5
5.25
2.2
0.7
1.2
Watts
Watts
Watts
during warm-up
steady state @ +25°C
steady state @ -40°C
RF Output
Parameter
Min
Typ
Max
Units
Condition
Signal [Standard]
Load
HCMOS
15
pF
Signal Level (Vol)
0.1
VDD
Signal Level (Voh)
Rise/Fall Time
Duty cycle
0.9
40
VDD
ns
+7
60
(10-90%)
%
@ (Voh-Vol)/2
Signal [Option]
Sinewave
Load
50
Ω
Output Power [Standard]
Output Power [Option]
Harmonics
0.0
3.0
+2.0
+5.0
4.0
7.0
-25
-60
dBm
dBm
dBc
dBc
50 Ohm load
50 Ohm load
Spurious
Frequency Tuning (EFC)
Parameter
Min
Typ
Max
Units
Condition
Tuning Range
Fixed, No Adjust
Tuning Range
Vref
Sufficient to compensate for 10 years aging
EFC (0V to 4V)
Source Current 1mA maximum
4.0
4.1
4.2
Vdc
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
Additional Parameters1 [10 to 20 MHz]
Parameter
Phase Noise
Max.
-100
Units
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
/g
Condition
Hz
10
100
1
10 to 20 MHz
-125
Hz
-140
kHz
-145
10
kHz
-145
100
kHz
Test at 10g sine vibration at 100Hz
G-Sensitivity
Parameter
1 x 10-9
Additional Parameters1 [>20 to 40 MHz]
Max.
-90
Units
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
/g
Condition
Phase Noise
10
100
1
Hz
Hz
> 20 to 40 MHz
-115
-130
kHz
kHz
kHz
-140
10
-140
100
Test at 10g sine vibration at 100Hz
G-Sensitivity
1 x 10-9
Environmental Conditions (Designed to meet)
• Radiation Tolerant (operating):
Active devices are selected from a family of product that is inherently
radiation tolerant to meet 100krad (SI) total dose
• Mechanical Shock (survive)***:
• Vibration Random (survive)***:
• Vibration Sine (survive)***:
MIL-STD-202, Test Method 213, Condition E (1000G, 0.5msec)
MIL-STD-202, Test Method 214, Condition I-F (20Grms, 3 minutes/axis)
MIL-STD-202, Test Method 204, Condition D (20Grms, 20 minutes/axis)
Note: *** Met by design, not tested
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
Screening Options
Ordering Code
Test Inspection
S
B
S-Level Screening
B-Level Screening
MIL-STD-883
Method 2023
Nondestructive Bond Pull
N/A
Internal Visual Per Mil-PRF-55310
Requirement
Internal Visual Per Mil-PRF-55310
Requirement
Internal Visual Per Mil-PRF-55310
Requirement
MIL-STD-883
MIL-STD-883
Stabilization Bake
Thermal Shock
Method 1008,
Condition C
150°C for 48hrs
Method 1008,
Condition C
150°C for 48hrs
MIL-STD-883
Method 1011,
Condition A
0°C to 100°C for
15cycles
N/A
MIL-STD-883
Method 1010,
Condition A
MIL-STD-883
Method 1010,
Condition A
-55°C to 85°C (2)
for 10cycles
-55°C to 85°C (2)
for 10cycles
Temperature Cycling (1)
MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
Constant Acceleration (1)
Seal (Fine & Gross Leak) (1)
N/A (Vacuum Seal)
N/A (Vacuum Seal)
MIL-STD-883
Method 2020,
Condition B
10g peak at 60Hz
minimum
PIND
N/A
Electrical Test
Burn-in (1)
Per Mil-PRF-55310 Requirement
85°C (2) for 240hrs
Per Mil-PRF-55310 Requirement
85°C (2) for 240hrs
Electrical Test
Per Mil-PRF-55310 Requirement
Per Mil-PRF-55310 Requirement
MIL-STD-883
Method 2012
Radiographic
Note:
N/A
(1) These test inspections deviate from screening requirements for class 2 oscillator in MIL-PRF-55310.
(2) The maximum operating and storage temperature of the EX-245 is +85°C. The EX-245 shall not be exposed to temperature higher than
+85°C at length of time.
(3) The design and construction of the EX-245 can withstand up to 1000g’s constant acceleration
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
Package Outline
Pin Function
Pin # With EFC
Fixed Frequency
No Connection
1
EFC
2-4
8
9
No Connection No Connection
Case/GND
Output
Case/GND
Output
13-14 No Connection No Connection
15
16
Vref
Supply
No Connection
Supply
**Pin numbers are for reference
Reflow Profile
220
183
150
60s
60-90s
45-60s
TIME (s)
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
How to order this product:
Use this worksheet to forward the following information to your factory representative :
S u p p l y RF Output Temperature
Stability
Options
Model
-
Voltage
Code
C
Code
Range
-
-
Frequency
EX-245
-
A
D
-
508
A
S
S
-
10M0000000
Crystal Options:
S: Swept Quartz
N: Non-Swept Quartz
Model Code:
245: Type A
Temperature Range:
K: 0 ... +60°C
D: -20...+70°C
F: -40...+85°C
Supply Voltage
Code:
C: 5 V
Screening Option:
S: “S” Level Screening
B: “B” Level Screening
E: “EM” Engineering Model
RF Output Code:
A: CMOS
G: Sinewave (0 dBm)
H: Sinewave (+3 dBm)
Other Options:
A: Electrical Tuning
F: Fixed Frequency
Stability:
508: ±50ppb
758: ±75ppb
107: ±100ppb
157: ±150ppb
Notes:
1
2
Contact factory for improved stabilities or additional product options. Not all options and codes are
available at all frequencies.
Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply
voltage, frequency control voltage, load, temperature (25°C)
Phase noise degrades with increasing output frequency.
Subject to technical modification.
3
4
5
Contact factory for availability.
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
相关型号:
©2020 ICPDF网 联系我们和版权申明