TFS1842A [VECTRON]

Development specification; 开发规范
TFS1842A
型号: TFS1842A
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Development specification
开发规范

文件: 总5页 (文件大小:65K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Tfs1842A.doc  
version 1.4  
30.10.2003  
VI TELEFILTER  
Development specification  
TFS 1842A  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedances  
for input:  
23  
13 dBm  
C
50  
(unbalanced)  
for output:  
50 // 1pF (balanced)  
Characteristics  
Remark:  
The maximum attenuation in the pass band is defined as the insertion loss a . The nominal frequency fN is fixed at 1842,5 MHz without any tolerance or  
e
limit. The values of absolute attenuation a  
temperature range is included in the production tolerance scheme.  
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating  
abs  
D a t a  
typ. value  
tolerance/limit  
Insertion loss  
(Reference level)  
within PB  
max.  
4,3  
dB  
-
Nominal frequency  
Centre frequency  
f
-
1842,5  
-
MHz  
N
f
1842,5  
MHz  
C
Pass band  
PB  
-
-
fN  
37,5  
2,3  
MHz  
dB  
Pass-band ripple within PB  
max  
Absolute attenuation  
a
abs  
0,0 MHz ...  
1160,0 MHz ...  
1430,0 MHz ...  
1705,0 MHz ...  
1920,0 MHz ...  
1980,0 MHz ...  
2100,0 MHz ...  
1160,0 MHz  
1430,0 MHz  
1705,0 MHz  
1785,0 MHz  
1980,0 MHz  
2100,0 MHz  
6000,0 MHz  
-
-
-
-
-
-
-
min  
min  
min  
min  
min  
min  
min  
37  
30  
20  
9
9
20  
20  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
Operating temperature range  
Storage temperature range  
- 10 °C ... + 75 °C  
- 40 °C ... + 85 °C  
Temperature coefficient of frequency  
TCf  
t.b.d.  
-
Input power level  
max  
5
dBm  
Generated:  
Checked / approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a  
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs1842A.doc  
version 1.4  
30.10.2003  
VI TELEFILTER  
Development specification  
TFS 1842A  
2/5  
Construction, pin configuration and 50 Ohm matching network  
(All dimensions in mm)  
5
4
6
L42 A  
Date code: Year+week  
R44  
N
P
R
2001  
2002  
2003  
...  
3
2
1
0,1  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Input Ground  
Input, unbalanced  
Input Ground  
Output, balanced  
Ground  
1
3
Output, balanced  
6
4
0,6  
0,6  
50 matching network:  
2
6
4
Input  
Output  
CL  
SAW  
50 Ohm  
50 Ohm  
1,3  
5
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a  
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs1842A.doc  
version 1.4  
30.10.2003  
VI TELEFILTER  
Development specification  
TFS 1842A  
3/5  
Stability Characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4  
Packing  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer  
9000  
min 300 mm  
min 500 mm  
min 300 mm  
EMBOSSED CARRIER TAPE  
Tape (all dimensions in mm)  
o
P
2
P
D
o
W
:
:
:
:
:
:
:
:
8
4
1,5  
1,75 ± 0,1  
3,5 ± 0,05  
0,75  
2
4
± 0,3  
± 0,1  
+ 0,1  
Po  
Do  
E
E
F
o
A
1
F
D
CT  
W
Bo  
G (min)  
P2  
P1  
± 0,05  
± 0,1  
G
D1(min) :  
1,5  
1
P
Ao  
Bo  
CT  
:
:
:
3,25 ± 0,1  
3,25 ± 0,1  
COVER TAPE  
5,5  
± 0,2  
W
2
Reel (all dimensions in mm):  
A
:
330  
8,4 + 2,0  
W1  
:
W2 (max) :  
14,4  
C
N (m in)  
C
:
50  
A
N
:
13 +0,5/ -0,2  
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a  
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs1842A.doc  
version 1.4  
30.10.2003  
VI TELEFILTER  
Development specification  
TFS 1842A  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name:  
Temperature: 150 °C - 170 °C  
Time: 60 sec. - 90 sec.  
pre-heating periods  
main-heating periods  
over 200 °C  
20 sec. - 25 sec.  
peak temperature  
255 °C ± 5 °C  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
90  
100  
110  
120  
130  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a  
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs1842A.doc  
version 1.4  
30.10.2003  
VI TELEFILTER  
Development specification  
TFS 1842A  
5/5  
History  
Version  
1.0  
Reason of Change  
Name  
Date  
generation of Development specificationaccording to customer requirements  
add page 2 ... 5 of specification  
Dr. Sabah  
24.07.2003  
1.1  
Konietzko  
Roizengaft  
Roizengaft  
Roizengaft  
16.09.2003  
17.10.2003  
27.10.2003  
30.10.2003  
1.2  
change relative attenuation to absolute attenuation  
change of package layout  
1.3  
1.4  
definition of packing  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a  
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS186A

Filter specification
VECTRON

TFS1880

Filter specification
VECTRON

TFS1880_05

Filter specification
VECTRON

TFS188A

Filter Specification
VECTRON

TFS188A_05

Filter specification
VECTRON

TFS190

Filter specification
VECTRON

TFS190C

Filter specification
VECTRON

TFS190D

Filter specification
VECTRON

TFS190E

Filter Specification
VECTRON

TFS190E_05

Filter specification
VECTRON

TFS190M

Filter specification
VECTRON

TFS190N

Filter Specification
VECTRON