TFS282A1 [VECTRON]
Filter Specification; 过滤器规格型号: | TFS282A1 |
厂家: | Vectron International, Inc |
描述: | Filter Specification |
文件: | 总4页 (文件大小:47K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Tfs282a1.doc
version 1.0
16.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 282 A1
1/4
______________________________________________________________________________________________________
Measurement condition
Ambient temperature:
Input power level:
23 °C
dBm
0
Terminating impedances
for input: 420 Ω // - 1,3 pF
for output: 420 Ω // - 1,3 pF
89 nH
External coil:
Construction and pin configuration
see page 2
Characteristics
Remark:
Reference level for the relative attenuation a of the TFS 282 A1 is the minimum of the pass band attenuation a
. The minimum of the pass band
min
rel
attenuation a
min
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB
e o
filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed on 282 MHz without tolerance. The given values for the relative
e
N
attenuation a and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency f is shifted due to the
rel
o
temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance for the centre frequency f .
f
o
D a t a
typ. value
tolerance/limit
_________________________________________________________________________________________________________
Insertion loss
a
= a
min
3,7
dB
max
5
dB
e
(Reference level)
_________________________________________________________________________________________________________
Nominal frequency 282,000 MHz
f
-
N
_________________________________________________________________________________________________________
Pass band ripple
282,0 MHz ± 65
kHz
-
max 1,5
dB
_________________________________________________________________________________________________________
Relative attenuation
a
rel
282,0 MHz ± 90
kHz
1,5
30
45
60
55
60
60
dB
max
3
dB
282,0 MHz ± 400
282,0 MHz ± 600
282,0 MHz + 800
282,0 MHz + 1,4 kHz ... 282,0 MHz + 3,0 MHz
282,0 MHz + 3,0 MHz ... 282,0 MHz + 30,0 MHz
kHz ... 282,0 MHz ± 600
kHz ... 282,0 MHz ± 800
kHz ... 282,0 MHz + 1,4 MHz
kHz
MHz
dB
dB
dB
dB
dB
dB
min 25
min 40
min 50
min 45
min 50
min 50
dB
dB
dB
dB
dB
dB
282,0 MHz - 800
kHz ... 282,0 MHz - 30,0 MHz
_________________________________________________________________________________________________________
Group delay distortion
282,0 MHz ± 100 kHz
_________________________________________________________________________________________________________
GDD
0,7
µs
max 2,0
µs
Input power
DC voltage
max 10
max
dBm
V
5
_________________________________________________________________________________________________________
Operating temperature range
Storage temperature range
- 20 °C ... + 75 °C
- 30 °C ... + 85 °C
Temperature coefficient of frequency TC
- 0,036 ppm/K²
-
f
Frequency inversion temperature
+ 25 °C
_________________________________________________________________________________________________________
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs282a1.doc
version 1.0
16.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 282 A1
2/4
______________________________________________________________________________________________________
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
7
5
282 A
M28
1
3
Pin 1
Pin 2
Pin 3
Pin 4
Sym. Output
Sym. Output
External Coil
Package Ground
Pin 5
Pin 6
Pin 7
Pin 8
Sym. Input
Sym. Input
Ground
Package ground
50 Ohm Test circuit 1
L1
L3
LB-IN
LB-OUT
6
C1
5
1
C2
SAW
2
L2
L4
3
L5
4, 7, 8
50 Ohm Test circuit 2
C1
C3
LB-IN
LB-OUT
6
5
1
L1
L2
SAW
2
C4
C2
3
L3
4, 7, 8
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs282a1.doc
version 1.0
16.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 282 A1
3/4
______________________________________________________________________________________________________
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
3000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER
TAPE
W
Po
Do
D1
E
:
:
:
:
16
4
± 0,3
± 0,1
Po
P
2
D
o
1,5 + 0,5
1,5 + 0,5
1,75 ± 0,1
7,5 ± 0,1
0,75
E
F
A
o
:
D
1
F
:
±
0,1
13,4
W
B
o
G (min) :
P2
P1
:
:
2
8
± 0,05
± 0,1
G
D1(min) : 1,5
P1
Ao
Bo
:
:
5,4 ± 0,1
5,4 ± 0,1
COVER TAPE
W
2
Reel (all dimensions in mm):
A
:
330
W1
:
:
16,4 +2
W2 (max) :
22,4
N (min)
C
>= 90
C
A
:
13
± 0,25
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the
right side of the tape.
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs282a1.doc
version 1.0
16.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 282 A1
4/4
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
pre-heating periods
main-heating periods
over 200 °C
peak temperature
255 °C ± 5 °C
Temperature: 150 °C - 170 °C
Time:
60 sec. - 90 sec.
20 sec. - 25 sec.
Chip-mount air reflow profile
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
temperature / °C
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
160
161
164
170
180
205
230
255
230
205
180
165
140
120
10
20
30
40
50
60
70
80
90
100
110
120
130
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明