VCA1 [VECTRON]

3.3, 5.0 volt CMOS Oscillator; 3.3 , 5.0伏的CMOS振荡器
VCA1
型号: VCA1
厂家: Vectron International, Inc    Vectron International, Inc
描述:

3.3, 5.0 volt CMOS Oscillator
3.3 , 5.0伏的CMOS振荡器

振荡器
文件: 总6页 (文件大小:93K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VCA1 series  
3.3, 5.0 volt CMOS Oscillator  
Features  
CMOS output  
Output frequencies to 160 MHz  
Tri-state output for board test and debug  
0/70 or –40/85 °C operating temperature  
Product is compliant to RoHS directive  
and fully compatible with lead free assembly  
Applications  
The VCA1 Crystal Oscillator  
SONET/SDH/DWDM  
Ethernet, Gigabit Ethernet  
Storage Area Network  
Digital Video  
Broadband Access  
Microprocessors/DSP/FPGA  
Description  
Vectron’s VCA1 Crystal Oscillator (XO) is quartz  
stabilized square wave generator with a CMOS  
output, operating off a 3.3 or 5.0 volt supply.  
fo  
Output  
Buffer /  
Disable  
The VCA1 uses fundamental or 3rd overtone  
crystals, for output frequencies < 80MHz,  
resulting in low jitter performance, typically 0.5ps  
rms in the 12 kHz to 20MHz band.  
Vectron International 267 Lowell Road, Hudson NH 03051  
Tel: 1-88-VECTRON-1  
e-mail: vectron@vectron.com  
Performance Characteristics  
Table 1. Electrical Performance, 5V option  
Parameter  
Symbol  
fO  
VDD  
Min  
0.032768  
4.5  
Typical  
Maximum  
160.000  
5.5  
Units  
MHz  
V
V
mA  
Frequency  
Operating Supply Voltage 1  
Absolute Maximum Supply Voltage  
Supply Current, Output Enabled  
0.032768 to 2.0 MHz  
2.01 to 30 MHz  
5.0  
-0.7  
7.0  
IDD  
10  
15  
40  
50  
30.01 to 50 MHz  
50.01 to 160.00 MHz  
Output Logic Levels  
Output Logic High2  
VOH  
VOL  
0.9*VDD  
V
V
Output Logic Low2  
0.1*VDD  
Output Rise/Fall Time2  
tR/tF  
ns  
0.032768 to 2.00 MHz  
2.01 to 20.00 MHz  
10  
8
20.01 to 160.00 MHz  
5
Duty Cycle3 (ordering option)  
Operating Temperature (ordering option)  
SYM  
TOP  
40/60 or 45/55  
0/70 or -40/85  
%
°C  
Storage Temperature  
TSTOR  
-55  
125  
°C  
ppm  
V
Stability4 (ordering option)  
±20, ±25, ±32, ±50, ±100  
F/T  
E/D  
Output Enable/Disable5  
Output Enabled  
Output Disabled  
Start-up time  
4.0  
0.8  
10  
TSU  
ms  
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.  
2. Figure 1 defines these parameters. Figure 2 illustrates the operating conditions under which these parameters are tested and  
specified.  
3. Symmetry is measured defined as On Time/Period.  
4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under  
operation).  
5. Output will be enabled if enable/disable is left open.  
tF  
tR  
IDD  
VOH  
50%  
4
1
+
-
3
.1µF  
.01µF  
2
VDD  
VOL  
IC  
VC  
On Time  
15pF  
+
-
Period  
Figure 1. Output Waveform  
Figure 2. Typical Output Test Conditions (25±5°C)  
Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1  
e-mail: vectron@vectron.com  
VCA1 Data Sheet  
Table 2. Electrical Performance, 3.3V option  
Parameter  
Symbol  
fO  
VDD  
Min  
0.032768  
2.97  
Typical  
Maximum  
160.000  
3.63  
Units  
MHz  
V
V
mA  
Frequency  
Operating Supply Voltage 1  
Absolute Maximum Operating Voltage  
Supply Current, Output Enabled  
0.032786 to 2.0 MHz  
3.3  
-0.5  
5.0  
IDD  
8
2.01 to 30 MHz  
30.01 to 50 MHz  
50.01 to 160 MHz  
10  
20  
35  
Output Logic Levels  
Output Logic High2  
VOH  
VOL  
tR/tF  
0.9*VDD  
V
V
ns  
Output Logic Low2  
0.1*VDD  
Output Rise/Fall Time2  
0.032768 to 2.00 MHz  
2.01 to 20.00 MHz  
12  
10  
6
20.01 to 160.00 MHz  
Duty Cycle3 (ordering option)  
Operating Temperature (ordering option)  
SYM  
TOP  
40/60 or 45/55  
0/70 or –40/85  
%
°C  
Storage Temperature  
TSTOR  
-55  
125  
°C  
ppm  
V
Stability4 (ordering option)  
±20, ±25, ±32, ±50, ±100  
F/T  
E/D  
Output Enable/Disable5  
Output Enabled  
Output Disabled  
Start-up time  
2.0  
0.5  
10  
TSU  
ms  
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.  
2. Figure 3 defines these parameters. Figure 4 illustrates the operating conditions under which these parameters are tested and  
specified. For Fo>90MHz, rise and fall time is measured 20 to 80%.  
3. Symmetry is measured defined as On Time/Period.  
4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under  
operation).  
5. Output will be enabled if enable/disable is left open.  
tF  
tR  
IDD  
VOH  
50%  
4
1
+
-
3
.1µF  
.01µF  
2
VDD  
VOL  
IC  
VC  
On Time  
15pF  
+
-
Period  
Figure 3. Output Waveform  
Figure 4. Typical Output Test Conditions (25±5°C)  
Vectron International 267 Lowell Rd, Hudson NH 03051  
Tel: 1-88-VECTRON-1  
e-mail vectron@vectron.com  
VCA1 Data Sheet  
Enable/Disable Functional Description  
Under normal operation the Enable/Disable is left open or set to a logic high state. When the E/D is set to  
a logic low, the oscillator stops and the output is in a high impedance state. This helps reduce power  
consumption as well as facilitating board testing and troubleshooting.  
Tri-state Functional Description  
Under normal operation the tri-state is left open or set to a logic high state. When the tri-state is set to a  
logic low, the oscillator remains active but the output buffer is in a high impedance state. This helps  
facilitate board testing and troubleshooting.  
Table 3. Outline Diagrams and Pin Out  
Pin #  
Symbol  
E/D or NC  
GND  
Function  
Tri-state, Enable/Disable or NC  
Electrical and Case Ground  
Output Frequency  
1
2
3
4
fO  
VDD  
Supply Voltage  
Figure 5, Package drawing  
Vectron International 267 Lowell Rd, Hudson NH 03051  
Tel: 1-88-VECTRON-1  
e-mail vectron@vectron.com  
VCA1 Data Sheet  
Reliability  
The VCA1 qualification tests have included:  
Table 4. Environnemental Compliance  
Parameter  
Conditions  
MIL-STD-883 Method 2022  
MIL-STD-883 Method 2007  
MIL-STD-883 Method 1010  
MIL-STD-883 Method 1014  
MIL-STD-883 Method 2015  
Mechanical Shock  
Mechanical Vibration  
Temperature Cycle  
Gross and Fine Leak  
Resistance to Solvents  
Handling Precautions  
Although ESD protection circuitry has been designed into the the VCA1, proper precautions should be  
taken when handling and mounting. VI employs a Human Body Model and a Charged-Device Model  
(CDM) for ESD susceptibility testing and design protection evaluation. ESD thresholds are dependent on  
the circuit parameters used to define the model. Although no industry wide standard has been adopted  
for the CDM, a standard HBM of resistance = 1.5kohms and capacitance = 100pF is widely used and  
therefore can be used for comparison purposes.  
Table 5. ESD Ratings  
Model  
Human Body Model  
Charged Device Model  
Minimum  
1000  
1500  
Conditions  
MIL-STD-883 Method 3115  
JESD 22-C101  
Suggested IR profile  
Devices are built using lead free epoxy and can also be subjected to standard lead free IR reflow  
conditions, Table 6 shows max temperatures and lower temperatures. A peak temperature of 240°C  
minimum should be used to reflow the lead solder.  
Table 6. Reflow Profile (IPC/JEDEC J-STD-020B)  
Parameter  
Symbol  
Value  
Preheat Time  
t S  
150 sec Min, 200 sec Max  
Ramp Up  
R UP  
t L  
3 oC/sec Max  
60 sec Min, 150 sec Max  
480 sec Max  
Time Above 217 oC  
Time To Peak Temperature  
Time At 260 oC (max)  
Time At 240 °C (max)  
Ramp Down  
t AMB-P  
t P  
10 sec Max  
tp2  
60 sec Max  
6 oC/sec Max  
R DN  
Vectron International 267 Lowell Rd, Hudson NH 03051  
Tel: 1-88-VECTRON-1  
e-mail vectron@vectron.com  
VCA1 Data Sheet  
Ordering Information:  
VCA1 -  
-
B
3
B
25M00  
Product Family  
Output Frequency  
Crystal Oscillator  
In MHZ  
Full Size 14 Pin DIP  
Voltage Options  
Electrical Options  
A: +5.0 Vdc +/-10%, 15pF  
B: +3.3 Vdc +/-10%, 15pF  
C: +3.0 Vdc +/-5%, 15pF  
E: +5.0 Vdc +/-10%, 50pF  
F: +3.3Vdc +/-5%, 50pF  
3: Tri-state, 45/55% Duty  
Stability Options  
The following codes are not  
A: ±100ppm, 0 to 70°C  
C: ±100ppm, -40 to 85°C  
B: ±50ppm, 0 to 70°C  
D: ±50ppm, -40 to 85°C  
E: ±25ppm, 0 to 70°C  
F: ±25ppm, -40 to 85°C  
G: ±20ppm*, 0 to 70°C  
*Aging not included.  
recommended for new designs  
0: No tri-state, 40/60% Duty  
1: Tri-state, 40/60% Duty  
2: No tri-state, 45/55%Duty  
5: Enable, 40/60% Duty  
6: Enable, 45/55% Duty  
Note: Not all combinations are available.  
Tri-state with a 45/55% is the most common Electrical code and is recommended for most applications.  
Devices will be shipped in Anti Static Tubes  
For Additional Information, Please Contact:  
USA: Vectron International 267 Lowell Road, Hudson, NH 03051  
Tel: 1-88-VECTRON-1 Fax: 1-888-FAX-VECTRON  
EUROPE: Landstrasse, D-74924, Neckarbischofsheim, Germany •  
Tel: 49 (0) 7268 8010 Fax: 49 (0) 7268 801281  
ASIA: Vectron Asia Pacific Sales 1F~2F. No.8 Workshop No.308 Fenju Rd.,  
WaiGaoQiao Free Trade Zone, Pudong New Area Shanghai, China 200131  
•Tel: 8621 50480777 • Fax: 8621 50481881  
www.vectron.com  
July 24, 2006  
Vectron International 267 Lowell Rd, Hudson NH 03051  
Tel: 1-88-VECTRON-1  
e-mail vectron@vectron.com  

相关型号:

VCA105

Thyristor Modules
IXYS

VCA105-06IO7

Silicon Controlled Rectifier, 180A I(T)RMS, 600V V(DRM), 600V V(RRM), 2 Element, ECOPAC-11
IXYS

VCA105-08IO7

Thyristor Modules
IXYS

VCA105-12IO7

Thyristor Modules
IXYS

VCA105-14IO7

Thyristor Modules
IXYS

VCA105-16IO7

Thyristor Modules
IXYS

VCA105-18IO7

Thyristor Modules
IXYS

VCA2611

Dual, Variable-Gain Amplifier with Low-Noise Preamp
BB

VCA2611Y/250

Dual, Variable-Gain Amplifier with Low-Noise Preamp
TAOS

VCA2611Y/2K

Dual, Variable-Gain Amplifier with Low-Noise Preamp
TAOS

VCA2612

TMDual, VARIABLE GAIN AMPLIFIER with Low Noise Preamp
BB

VCA2612

Wideband, > 40dB Gain Adjust Range, Linear in V/V VARIABLE GAIN AMPLIFIER
TI