Data Sheet
M-FIAM7
Military COTS 28 Vin Filter
Input Attenuator Module
Features
• EMI filtering-MIL-STD-461E
• Transient protection-MIL-STD-1275A/B/D,
MIL-STD-704A-F and DO-160E
• Environments-MIL-STD-810, MIL-STD-202
• Environmental stress screening
• Low profile mounting options
• Output power up to 130 W
• Output current up to 10 A
• Mini sized package
Model Number: M-FIAM7M21*
Shown actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
• Inrush current limiting
Absolute Maximum Rating
Parameter
Product Highlights
Rating
50
Unit
Vdc
Notes
The M-FIAM7 is a DC front-end module that
provides EMI filtering and transient
protection. The M-FIAM7 enables designers
using Vicor’s 28 V DC-DC V•I Chip modules
to meet conducted emission/ conducted
susceptibility per MIL-STD-461E; and input
transients per MIL-STD-1275A/B/D,
MIL-STD-704A-F and DO-160E. The
M-FIAM7 accepts an input voltage of
14 – 50 Vdc and delivers output current
up to 10 A.
Continuous
+In to –In
100
Vdc
See Fig.1
Mounting torque
5 (0.57)
500 (260)
750 (390)
in-lbs
°F(°C)
°F(°C)
6 each, #4-40 or M3
<5 sec; wave solder
<7 sec; hand solder
Pin soldering temperature
Thermal Resistance and Capacity
Parameter
Min
Typ
Max
Unit
Baseplate to sink
flat, greased surface
M-FIAM7 is housed in an industry
0.16
0.1
°C/Watt
°C/Watt
standard "half brick" module measuring
2.28" x 2.2" x 0.5" and depending upon
model selected, may be mounted onboard
or inboard for height critical applications.
with thermal pad (P/N 20264)
Baseplate to ambient
Free convection
7.9
2.2
°C/Watt
°C/Watt
1000 LFM
Compatible Products
• 28 V Input DC-DC V•I Chip modules.
MTBF per MIL-HDBK-217F (M-FIAM7M21)
Note: This product is not compatible with
Maxi, Mini, Micro DC-DC converters.
Temperature
25°C
Environment
MTBF
3,540
637
Unit
Ground Benign: G.B.
Naval Sheltered: N.S.
1,000 Hrs
1,000 Hrs
50°C
65°C
Airborne Inhabited Cargo: A.I.C.
499
1,000 Hrs
Part Numbering*
M-FIAM7
M
2
1
Product Grade Temperatures (°C)
Grade Operating Storage
M = –55 to +100 –65 to +125
H = –40 to +100 –55 to +125
Pin Style
1 = Short Pin
2 = Long Pin
Baseplate
1 =Slotted
2 =Threaded
Product
S = Short ModuMate*
N = Long ModuMate*
F = Short RoHS
3 =Thru hole
G = Long RoHS
*Compatible with SurfMate and InMate socketing system.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Page 1 of 6
Set your site on VICOR at vicorpower.com
SPECIFICATIONS
(typical at T = 25°C, nominal line and 75% load, unless otherwise specified)
BP
INPUT SPECIFICATIONS
Parameter
Input voltage
Inrush limiting
Min
Typ
Max
50
Unit
Vdc
A/µF
Vdc
Vdc
Vdc
Vdc
Notes
14
28
Continuous
0.007
100
250
70
50 ms per MIL-STD-1275A/B/D, continuous operation
70 µs per MIL-STD-1275B, continuous operation
20 ms per MIL-STD-704A, continuous operation
100 ms per DO-160E, Section 16, Power Input, Category Z
Transient immunity
80
OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Max
10
Unit
A
Notes
Output current
Output power
Over continuous input and temp. range (see Fig.4)
Transient compliance over temp. range (see Fig.6)
130
W
Efficiency
96
98
%
Internal voltage drop
0.5
0.7
@10 A, 100°C baseplate
External capacitance
See illustration C1 on page 4
330
1000
µF
63 V
CONTROL PIN SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
ON/OFF control
Enable (ON)
0.0
4.0
1.0
Vdc
Vdc
Referenced to – Vout
Disable (OFF)
5.50
100 kΩ internal pull-up resistor
SAFETY SPECIFICATIONS
Parameter
Min
Typ
1,500
2,121
Max
Vrms
Vdc
Unit
Notes
Input/Output to Base
Input/Output to Base
Dielectric withstand
EMI
Standard
Test Procedure
Notes
MIL-STD-461E
Conducted emissions:
CE101, CE102
Conducted susceptibility:
CS101, CS114, CS115, CS116
GENERAL SPECIFICATIONS
Parameter
Weight
Min
Typ
Max
3.3 (94)
2
Unit
Ounces (grams)
Years
Notes
Warranty
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Page 2 of 6
Set your site on VICOR at vicorpower.com
SPECIFICATIONS (CONT.)
ENVIRONMENTAL QUALIFICATION
Altitude
MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor
with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17
with overall level of 7.7 G rms for 1 hour per axis.
Shock
MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft.
MIL-STD-202F, Method 213B, 60 g, 9ms half sine. MIL-STD-202F, Method 213B, 75 g, 11ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions.
Humidity
MIL-STD-810F, Method 507.4.
Solder Test
MIL-STD-202G, Method 208H, 8 hour aging.
ENVIRONMENTAL STRESS SCREENING
Parameter
H-Grade
M-Grade
Operating temperature
Storage temperature
-40°C to +100°C
-55°C to +125°C
-55°C to +100°C
-65°C to +125°C
12 cycles
-65°C to +100°C
12 cycles
-65°C to +100°C
Temperature cycling*
Ambient test @ 25°C
Power cycling burn-in
Functional and parametric ATE tests
Hi-Pot test
Yes
12 hours, 29 cycles
-40°C and +100°C
Yes
Yes
24 hours, 58 cycles
-55°C and +100°C
Yes
Visual inspection
Yes
Yes
Test data
vicorpower.com
vicorpower.com
Shut Down Time vs. Overvoltage
250
200
150
100
50
0
60
70
80
90
100
105
110
120
Vin (V)
Figure 2 – Conducted Noise; M-FIAM7 and
MP028F036M12AL + MV036F120M010 DC-DC V•I Chip
modules operating at 28 Vdc, 120 W.
Figure 1 – T = Time period before over-voltage protection.
Vin = Input voltage (switching up from 28 Vdc)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Page 3 of 6
Set your site on VICOR at vicorpower.com
Figure 3 – Transient Immunity; M-FIAM7 output response to
an input transient.
Figure 4 `–Inrush Limiting; Inrush current with 1000 μF
external capacitance.
M-FIAM7 EMI and MIL-STD-1275D
Transient Compliance
M-FIAM7 EMI Compliance Only
140
600
130
500
400
300
120
Safe Operating
110
Area
Safe Operating
200
100
Area
(Normal Operation)
(Transient 50 mS max.)
100
0
0
5
10
15
20
25
30
35
40
45
50
0
10 14 20 30 40 50 60 70 80 90 100 110
Input Voltage (VDC)
Input Voltage (VDC)
Figure 5 – M-FIAM7 EMI Compliance only
Figure 6 –M-FIAM7 EMI and MIL-STD-1275D Transient
Compliance
C
C
V
S
S
I
+Out
-Out
+In
-In
–
–
O
N
ON
PRM-AL C
EMI
OFF
Transorb
GND
T
V
P
VTM
C1
NC
P/N
+In
+Out
MFIAM7
19180-510
NC
+
NC
+Out
-Out
Input
F1
+
K
Ro
–In
–Out
C
C
Component Suggestions
Recommended Fuse: (F1) 10 A (max), Bussmann ABC style
Capacitance: (C1) 330 µF (min), 1000 µF (max); (C) 4700 pF
Figure 7 – Basic connection diagram with Transient, Surge Protection and Recommended Reverse Polarity Protection.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Page 4 of 6
Set your site on VICOR at vicorpower.com
MECHANICAL DRAWINGS
Module Pins
No.
Function
Label
1
+In
+
No
Connection
2
NC
3
4
5
6
Ground
–In
EMI/GND
–
–
–Out
ON/OFF
ON/OFF
No
Connection
7
NC
No
Connection
8
9
NC
+
+Out
Figure 8 – Mechanical diagram
INBOARD
SOLDER
MOUNT
ONBOARD
SOLDER
MOUNT
SHORT PIN STYLE
0.094 0.003
LONG PIN STYLE
0.094 0.003
2,39 0,08
0.062 0.010
PCB THICKNESS
(7X)
(2X)
1,57 0,25
ALL MARKINGS
THIS SURFACE
2,39 0,08
PLATED
THROUGH HOLE
DIA
0.164 0.003
4,16 0,08
0.164 0.003
4,16 0,08
1.790**
45,47
0.06
R
(4X)
0.158
4,01
1,5
1
9
2
8
3
6
4
5
1.575**
40,00
1.900*
48.,26
ALUMINUM
BASEPLATE
7
PINS STYLES
SOLDER:TIN / LEAD
HOT SOLDER DIPPED
MODUMATE: GOLD PLATED COPPER
0.400*
10,16
0.43
10,9
0.53
13,5
0.700*
17,78
1.000*
25,40
1.400*
35,56
0.003
0,08
* DENOTES TOL =
** PCB WINDOW
0.195
4,95
Figure 9 – PCB Mounting Specifications
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Page 5 of 6
Set your site on VICOR at vicorpower.com
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or
maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original
purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products
returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the
product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability,
function, or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither
does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of
its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor
Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and
indemnifies Vicor against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC
modules and accessory components, fully configurable AC-DC and DC-DC power supplies,
and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or
malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available
upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
3/09
Set your site on VICOR at vicorpower.com
相关型号:
©2020 ICPDF网 联系我们和版权申明