MI-200
50 to 100 Watts
Features & Benefits
Packaging Options
• Inputs:
Standard: Slotted baseplate
■■28VDC per MIL-STD-704D/E/F
■■155VDC per MIL-STD-1399A
■■270VDC per MIL-STD-704D/E/F
SlimMod: Flangeless baseplate, option suffix: - S
Example: MI - 2XX - XX - S
• Single output: 2 – 48VDC
• Up to 23W/in3
FinMod: Finned heat sink, option suffix:
- F1, -F2, -F3 and - F4
• MIL-STD-810 environments
• Up to 90% efficiency
• Remote sense
Examples:
MI - 2XX - XX -F1, 0.25” fins, longitudinal
MI - 2XX - XX -F2, 0.50” fins, longitudinal
MI - 2XX - XX -F3, 0.25” fins, transverse
MI - 2XX - XX -F4, 0.50” fins, transverse
• Current limit
• OVP and thermal shutdown
Converter Selection Chart
• Power boosters for
higher power outputs
MI-2
Semi-custom modules available, consult factory.
• ZCS power architecture
• Low noise FM control
Input Voltage
• Size: 4.6” x 2.4” x 0.5”
(116,8 x 61,0 x 12,7 mm)
Nominal
2 = 28V
Range
Transient [a]
60V
Notes
[b]
18 – 50V
28VDC input per MIL-STD 704D/E/F
155VDC input per MIL-STD-1399A
270VDC input per MIL-STD-704D/E/F
5 = 155V
6 = 270V
7 = 165V
100 – 210V
125 – 400V
100 – 310V
230V
Product Highlights
[c]
475V
The MI-200 family of DC-DC converters is
designed for applications utilizing distributed
power architectures. Based on Vicor’s
VI-200 / VI-J00 family of zero-current
switching, component level DC-DC converters,
the MI-200 family offers exceptional
n/a
[a] Transient voltage for 1 second.
[b] 16V operation at 75% load.
[c] These units rated at 75% load from
125 – 150VIN: MI-J6Z-xY, MI-J6Y-xY,
MI-J60-xY
Product Grade Temperature (°C)
Operating
Storage
performance in terms of power density,
efficiency, noise, ease of use, and reliability.
I
= –40 to +85
= –55 to +85
I = –55 to +100
M = –65 to +100
M
Output Voltage
Fully encapsulated in Vicor’s industry standard
package, the MI-Series meets MIL-STD-810
environmental requirements for humidity,
fungus, salt-fog, explosive atmosphere,
acceleration, vibration and shock.
Overtemperature shutdown 95°C typical
(recycle power to restart)
Z = 2.0V
Y = 3.3V
0 = 5.0V
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V [d]
R = 7.5V [d]
M = 10V
1 = 12V
P = 13.8V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
Output Power/Current VOUT
Standard features, such as wide output
trimming/programming, current limiting,
remote sense, output inhibit, and latching
OVP and OTP combine to offer the highest
degree of protection, versatility, and reliability
for power systems.
≥5V
<5V
Y = 50W
X = 75W
W= 100W
Y = 10A
X = 15A
W= 20A
V = 30A
V =
—
For additional output power,
100W and 75W booster modules available
Change (MI-2xx-xx) to (MI-Bxx-xx)
[d] 75W max power for 28V input
MI-200 DC-DC Converters
Page 1 of 7
Rev 1.6
06/2017
vicorpower.com
800 927.9474
MI-200
Converter Specifications
(Typical at TBP =25°C, nominal line and 75% load, unless otherwise specified)
Input Specifications
Parameter
nrush charge
Min
Typ
Max
Units
Test Conditions
I
120x10-6
200x10-6
Coulombs
Nominal line
Input reflected
10%
IIN
Nominal line, full load
ripple current – pp
VIN
30+20Log
(
(
)
)
dB
120Hz, nominal line
2400Hz, nominal line
VOUT
VIN
Input ripple rejection
20+20Log
dB
VOUT
No load power dissipation
1.35
2
Watts
Output Characteristics
Parameter
Min
Typ
0.5%
0.05%
0.2%
0.01
Max
1%
Units
VNOM
Test Conditions
Setpoint accuracy
0.2%
0.5%
0.02
VNOM
LL to HL, 10% to Full Load
LL to HL, No Load to 10%
Over rated temperature
Load/line regulation
VNOM
Output temperature drift
Long term drift
% / °C
0.02
100
%/1K hours
mV
150
Whichever is greater
20MHz bandwidth
Output ripple – pp
1.0%
1.5%
VNOM
VNOM
[a]
Trim range
50%
0.5
110%
Total remote
Volts
sense compensation
[b]
OVP set point
115%
105%
20%
125%
135%
125%
130%
VNOM
INOM
INOM
latching
Current limit
Automatic restart
[c]
Short circuit current
[a] 10V to 15V outputs, standard trim range 10%. Consult factory for wider trim range.
3.3V output trim range 2.20 to 3.63V
[b] No over temperature or voltage protection in booster modules
[c] Output voltages of 5V or less incorporate foldback current limiting; outputs of 10V and above provide constant current limiting.
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 5.
Control Pin Specifications
Parameter
Min
Typ
50
Max
Units
Ohms
Ohms
Volts
Volts
mA
Test Conditions
Gate out impedance
Gate in impedance
Gate in open circuit voltage
Gate in low threshold
Gate in low current
Power sharing accuracy
1000
6
Use open collector
0.65
0.95
6
1.05
MI-200 DC-DC Converters
Page 2 of 7
Rev 1.6
06/2017
vicorpower.com
800 927.9474
MI-200
Converter Specifications (Cont.)
(Typical at TBP =25°C, nominal line and 75% load, unless otherwise specified)
Dielectric Withstand Characteristics
Parameter
Min
3,000
500
Typ
Max
Units
VRMS
VRMS
VRMS
pF
Test Conditions
Input to output
Baseplate earthed
Output to baseplate
Input to baseplate
Input to output capacitance
1,500
50
75
Thermal Characteristics
Parameter
Min
Typ
Max
Units
Test Conditions
Efficiency
80 – 90%
Baseplate to sink
0.07
95
°C/Watt
°C
With thermal pads
thermal impedance
[d]
Thermal shutdown
(Drivers only)
Cool and recycle power
to restart
90
105
[d] No over temperature or voltage protection in booster modules
Enviornmental – MIL-STD-810D
Parameter
Min
70,000
86/240
9
Typ
Max
Units
Test Conditions
Procedure II
Altitude - method 500.2
Humidity - method 507.2
Acceleration - method 513.3
Vibration - method 514.3
Shock - method 516.3
feet
%/hours
Procedure I, cycle 1
Procedure II
g
g
g
20
Procedure I, category 6
Procedure I
40
Reliability – MIL-HDBK-217F (MI-22L-MW)
Parameter
Min
Typ
3,552
639
Max
Units
Test Conditions
25°C Ground Benign: G.B.
50°C Naval Sheltered: N.S.
1,000 hours
1,000 hours
65°C Airborne Inhabited
Cargo: A.I.C.
501
1,000 hours
Mechanical Specifications
Parameter
Min
Typ
Max
Units
Test Conditions
7.2
7.3
7.4
Ounces
Grams
Weight
205
208
210
MI-200 DC-DC Converters
Page 3 of 7
Rev 1.6
06/2017
vicorpower.com
800 927.9474
MI-200
Converter Specifications (Cont.)
Product Grade Specifications
Parameter
I-Grade
M-Grade
Storage temperature
Operating temperature (baseplate)
Power cycling burn-in
-55°C to +100°C
-40°C to +85°C
12 hours, 29 cycles
-65°C to +100°C
-55°C to +85°C
96 hours, 213 cycles
Temperature cycled with power off
17°C per minute rate of change
12 cycles
12 cycles
-65°C to +100°C
-65°C to +100°C
Test data supplied at these temperatures[e]
-40°C, +80°C
2 years
-55°C, +80°C
2 years
Warranty
Environmental compliance
MIL-STD-810
MIL-STD-810
Derating
NAVMAT P-4855-1A
NAVMAT P-4855-1A
[e] Test data available for review or download from vicorpower.com
Maximum Capacitance, Rated Output Voltage <5V
Rated VOUT (V)
2 to <3
IOUT Rating (A)
CMAX (µF)
1500
IOUT Rating (A)
>10 to 40
CMAX (µF)
5000
≤10
≤10
3 to <5
1000
>10 to 40
5000
Maximum Capacitance, Rated Output Voltage ≥5V
Rated VOUT (V)
5 to <7.5
7.5 to <10
10 to <28
>28
POUT Rating (W)
CMAX (µF)
1000
400
POUT Rating (W)
>50 to 100
CMAX (µF)
1500
700
≤50
≤50
≤50
≤50
>50 to 100
400
>50 to 100
500
150
>50 to 100
250
Enviornmental Qualifications
Parameter
Qualification
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40K ft.).
A
ltitude
MIL-STD-810D, Method 500.2, Procedure II, 40,000ft., 1000 – 1500ft./min. to 70,000ft., unit functioning
MIL-STD-810C, Method 511.1, Procedure I
Explosive Atmosphere
Vibration
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20g
MIL-STD-810D, Method 514.3 random: 10 – 300Hz @ 0.02g2/Hz, 2000Hz @ 0.002g2/Hz, 3.9 total Grms
3 hrs/axis. Sine: 30Hz @ 20g, 60Hz @ 10g, 90Hz @ 6.6g, 120Hz @ 5.0g, 16.0 total Grms, 3 axes
MIL-STD-810E, Method 514.4, Table 514.4-VII, 6db/octave, 7.7G rms, 1hr/axis
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40g
MIL-STD-202F, Method 213B, 18 pulses, 60g, 9msec
Shock
MIL-STD-202F, Method 213B, 75g, 11ms saw tooth shock
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet
Acceleration
Humidity
Solder Test
Fungus
MIL-STD-810D, Method 513.3, Procedure II Operational test, 9g for 1 minute along 3 mutually perpendicular axes
MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity
MIL-STD-202, Method 208, 8hr. aging
MIL-STD-810C, Method 508.1
MI-200 DC-DC Converters
Page 4 of 7
Rev 1.6
06/2017
vicorpower.com
800 927.9474
MI-200
Basic Module Operation
C2a
C2b
C1a
C1b
F1
C3
+IN
–IN
ZeSrwoitCcuhrinregnt+OUT
Converter
–OUT
400
C3 (µF) =
VIN Minimum
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Design Guide & Applications Manual.
Output Connections and Considerations
The permissible load current[e] must never be exceeded during
normal, abnormal or test conditions. Converters subject to
dynamic loading exceeding 25% of rated current must be
Storage
Vicor products, when not installed in customer units, should
be stored in ESD safe packaging in accordance with
ANSI/ESD S20.20, “Protection of Electrical and Electronic
reviewed by Vicor Applications Engineering to ensure that the
Parts, Assemblies and Equipment” and should be maintained
converter will operate properly.
in a temperature controlled factory/warehouse environment
Under dynamic load, light load, or no load conditions, the
converter may emit audible noise. Converters that utilize remote
sense may require compensation circuitry to offset the phase
lag caused by the external output leads and load impedance.
Remote Sense leads must be protected for conditions such as
lead reversal, noise pickup, open circuit, or excessive output lead
resistance between the sense point and the converters output
terminals. For applications that may draw more than the rated
current, a fast acting electronic circuit breaker must be utilized
to protect the converter. Under no circumstance should the
rated current be exceeded. Utilizing or testing of current limit or
short circuit current will damage the converter. Ensure that the
total output capacitance connected to the converter does not
exceed the limits on Page 4.
not exposed to outside elements controlled between the
temperature ranges of 15ºC and 38ºC. Humidity shall not be
condensing, no minimum humidity when stored in an ESD
compliant package.
Nominal Power Rating
[e] Permissible load current:
Nominal VOUT
MI-200 DC-DC Converters
Page 5 of 7
Rev 1.6
06/2017
vicorpower.com
800 927.9474
MI-200
Mechanical Drawing
4.60
(116,8)
3.60
.50
0.080 (2,0) Dia (2) places
(91,4)
(12,7)
1.80
Solder plate over copper alloy
(45,7)
.30±.015
(7,6)±(0,38)
Pin #
1
Function
+In
2
Gate In
Gate Out
-In
4
9
3
4
3
8
7
6
2.10
1.40
5
+Out
VI-200
MI-200
(35,6)
1.00
(53,3)
.70
(25,4)
6*
7*
8*
9
+Sense
Trim
2
(17,8)
.40
(10,2)
1
5
.35±.015
(8,9)±(0,38)
-Sense
-Out
* Do not connect on booster modules
FULL R
.15
R
.15
(3,8)
(3,8)
Product ID
this surface
.040 (1,0) Dia (7) places
.
Solder plate over copper alloy
2.40
(61,0)
.30
4.20
1.75
(7,6) Min
.22
(106,7)
Max.
(44,5)
(5,6) MIN
.50
(12,7)
+.030 (0,76)
-.000 (0)
.01
.12
Aluminum Base
(3,0)
Note: For alternate package options refer to the mechanical drawing page of vicorpower.com
MI-200 DC-DC Converters
Page 6 of 7
Rev 1.6
06/2017
vicorpower.com
800 927.9474
MI-200
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/vi-200_vi-j00 for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
MI-200 DC-DC Converters
Page 7 of 7
Rev 1.6
06/2017
vicorpower.com
800 927.9474
相关型号:
©2020 ICPDF网 联系我们和版权申明