MI-264MX-F1 概述
1-OUTPUT 75W DC-DC REG PWR SUPPLY MODULE, MODULE-9 电源模块
MI-264MX-F1 规格参数
是否无铅: | 含铅 | 是否Rohs认证: | 不符合 |
生命周期: | Active | 零件包装代码: | MODULE |
包装说明: | MODULE-9 | 针数: | 9 |
Reach Compliance Code: | compliant | 风险等级: | 5.85 |
其他特性: | REMOTE SHUTDOWN | 模拟集成电路 - 其他类型: | DC-DC REGULATED POWER SUPPLY MODULE |
认证: | CE | 效率(主输出): | 90% |
高度: | 12.7 mm | 最大输入电压: | 400 V |
最小输入电压: | 125 V | 标称输入电压: | 270 V |
JESD-30 代码: | R-XDFM-P9 | JESD-609代码: | e0 |
长度: | 116.6 mm | 最大电网调整率: | 0.5% |
最大负载调整率: | 0.5% | 功能数量: | 1 |
输出次数: | 1 | 端子数量: | 9 |
最高工作温度: | 85 °C | 最低工作温度: | -55 °C |
最大输出电压: | 52.8 V | 最小输出电压: | 24 V |
标称输出电压: | 48 V | 封装主体材料: | UNSPECIFIED |
封装形状: | RECTANGULAR | 封装形式: | FLANGE MOUNT |
峰值回流温度(摄氏度): | NOT SPECIFIED | 认证状态: | Not Qualified |
纹波电压(主输出): | 0.05304 Vrms | 子类别: | Power Supply Modules |
表面贴装: | NO | 技术: | HYBRID |
温度等级: | OTHER | 端子面层: | TIN LEAD OVER COPPER |
端子形式: | PIN/PEG | 端子位置: | DUAL |
处于峰值回流温度下的最长时间: | NOT SPECIFIED | 最大总功率输出: | 75 W |
微调/可调输出: | YES | 宽度: | 60.7 mm |
Base Number Matches: | 1 |
MI-264MX-F1 数据手册
通过下载MI-264MX-F1数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Data Sheet
MI-200
Features
• Inputs:
28 Vdc per MIL-STD-704D/E/F
155 Vdc per MIL-STD-1399A
270 Vdc per MIL-STD-704D/E/F
• Single output: 2 – 48 Vdc
DC-DC Converters
50 to 100 Watts
3
• Up to 23 W/in
• MIL-STD-810 environments
• Up to 90% efficiency
• Remote sense
• Current limit
• OVP and thermal shutdown
• Power boosters for higher power outputs
• ZCS power architecture
• Low noise FM control
• Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7 mm)
Converter Selection Chart
MI-2
Semi-custom driver and booster modules available, consult factory.
Input Voltage
Nominal
2 = 28 V
5 = 155 V
6 = 270 V
7 = 165 V
Range
Transient[a]
60 V
Notes
18 – 50 V [b]
100 – 210 V
125 – 400 V [c]
100 – 310 V
28 Vdc input per MIL-STD 704D/E/F
155 Vdc input per MIL-STD-1399A
270 Vdc input per MIL-STD-704D/E/F
Product Highlights
The MI-200 family of DC-DC converters is
designed for applications utilizing distributed
power architectures. Based on Vicor’s VI-200 /
VI-J00 family of zero-current switching,
component level DC-DC converters, the MI-200
family offers exceptional performance in terms of
power density, efficiency, noise, ease of use, and
reliability.
230 V
475 V
n/a
[a]
Transient voltage for 1 second
16 V operation at 75% load
[b]
[c]
MI-26Z-xV, MI-26Y-xV rated at 75% load from 125 – 150 VIN
Fully encapsulated in Vicor’s industry standard
package, the MI-Series meets MIL-STD-810
environmental requirements for humidity, fungus,
salt-fog, explosive atmosphere, acceleration,
vibration, and shock.
Output Voltage
Product Grade Temperature (°C)
Operating
Storage
1 = 12 V
Z = 2.0 V
Y = 3.3 V
0 = 5.0 V
X = 5.2 V
W = 5.5 V
V = 5.8 V
T = 6.5 V[d]
R = 7.5 V[d]
M = 10 V
I = –40 to +85
M = –55 to +85
I = –55 to +100
M = –65 to +100
P = 13.8 V
2 = 15 V
N = 18.5 V
3 = 24 V
L = 28 V
J = 36 V
K = 40 V
4 = 48 V
Overtemperature shutdown 95°C typical
(recycle power to restart)
Standard features such as wide output trim-
ming/programming, current limiting, remote
sense, output inhibit, and latching OVP and OTP
combine to offer the highest degree of protection,
versatility, and reliability for power systems.
Output Power/Current VOUT
≥ 5 V
<5 V
Y = 50 W
X = 75 W
W= 100 W
Y = 10 A
X = 15 A
W= 20 A
V = 30 A
Packaging Options
[d] 75 W max power for 28 V input
Standard: Slotted baseplate
V =
—
For additional output power,
100 W and 75 W booster modules available
SlimMod: Flangeless baseplate, option suffix: - S
Example: MI - 2XX - XX - S
Change (MI-2xx-xx) to (MI-Bxx-xx)
FinMod: Finned heat sink, option suffix:
- F1, - F2, -F3 or -F4
Examples:
MI - 2XX - XX -F1, 0.25" fins, longitudinal
MI - 2XX - XX -F2, 0.50" fins, longitudinal
MI - 2XX - XX -F3, 0.25" fins, transverse
MI - 2XX - XX -F4, 0.50" fins, transverse
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Rev. 1.4
Page 1 of 6
Set your site on VICOR at vicorpower.com
CONVERTER SPECIFICATIONS
(typical at T = 25°C, nominal line and 75% load, unless otherwise specified)
BP
INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Units
Test Conditions
Inrush charge
120x10-6
200x10-6
Coulombs
Nominal line
Input reflected
ripple current – pp
10%
I
IN
Nominal line, full load
VIN
30+20Log
dB
120 Hz, nominal line
2400 Hz, nominal line
(
(
)
)
VOUT
Input ripple rejection
VIN
VOUT
dB
20+20Log
No load power dissipation
1.35
2
Watts
OUTPUT CHARACTERISTICS
Parameter
Min
Typ
Max
1%
Units
VNOM
VNOM
Test Conditions
Setpoint accuracy
0.5%
0.05%
0.2%
0.01
0.2%
0.5%
0.02
LL to HL, 10% to Full Load
LL to HL, No Load to 10%
Over rated temperature
Load/line regulation
V
NOM
Output temperature drift
Long term drift
% / °C
0.02
100
%/1K hours
mV
150
Whichever is greater
20 MHz bandwidth
Output ripple – pp
1.0%
1.5%
VNOM
VNOM
Trim range[a]
50%
0.5
110%
Total remote
sense compensation
Volts
OVP set point[b]
Current limit
115%
105%
20%
125%
135%
125%
130%
VNOM
INOM
INOM
latching
Automatic restart
Short circuit current [c]
[a] 10 V, 12 V and 15 V outputs, standard trim range 10%. Consult factory for wider trim range.
3.3 V output trim range 2.20 to 3.63 V
[b] No over temperature or voltage protection in booster modules
[c] Output voltages of 5 V or less incorporate foldback current limiting; outputs of 10 V and above provide constant current limiting.
CONTROL PIN SPECIFICATIONS
Parameter
Min
Typ
50
Max
Units
Ohms
Ohms
Volts
Volts
mA
Test Conditions
Gate out impedance
Gate in impedance
Gate in open circuit voltage
Gate in low threshold
Gate in low current
Power sharing accuracy
1000
6
Use open collector
0.65
0.95
6
1.05
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Rev. 1.4
Page 2 of 6
Set your site on VICOR at vicorpower.com
CONVERTER SPECIFICATIONS (cont.)
DIELECTRIC WITHSTAND CHARACTERISTICS
Parameter
Min
3,000
500
Typ
Max
Units
VRMS
VRMS
VRMS
pF
Test Conditions
Input to output
Baseplate earthed
Output to baseplate
Input to baseplate
Input to output capacitance
1,500
50
75
THERMAL CHARACTERISTICS
Parameter
Min
Typ
Max
Units
Test Conditions
Efficiency
80 – 90%
Baseplate to sink
thermal impedance
0.07
95
°C/Watt
°C
With thermal pads
Thermal shutdown[
(Drivers only)
Cool and recycle power
to restart
d]
90
105
[d]
No over temperature or voltage protection in booster modules
ENVIRONMENTAL – MIL-STD-810D
Parameter
Min
70,000
86/240
9
Typ
Max
Units
Test Conditions
Procedure II
Altitude - method 500.2
Humidity - method 507.2
Acceleration - method 513.3
Vibration - method 514.3
Shock - method 516.3
feet
%/hours
Procedure I, cycle 1
Procedure II
g
g
g
20
Procedure I, category 6
Procedure I
40
RELIABILITY - MIL-HDBK-217F (MI-22L-MW)
Parameter
Min
Typ
3,552
639
Max
Units
Test Conditions
25°C Ground Benign: G.B.
50°C Naval Sheltered: N.S.
1,000 hours
1,000 hours
65°C Airborne Inhabited
Cargo: A.I.C.
501
1,000 hours
MECHANICAL SPECIFICATIONS
Parameter
Weight
Min
Typ
Max
Units
Test Conditions
7.2
205
7.3
208
7.4
210
Ounces
Grams
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Rev. 1.4
Page 3 of 6
Set your site on VICOR at vicorpower.com
CONVERTER SPECIFICATIONS (cont.)
PRODUCT GRADE SPECIFICATIONS
Parameter
I-Grade
M-Grade
Storage temperature
Operating temperature (baseplate)
Power cycling burn-in
-55°C to +100°C
-40°C to +85°C
12 hours, 29 cycles
-65°C to +100°C
-55°C to +85°C
96 hours, 213 cycles
Temperature cycled with power off
17°C per minute rate of change
12 cycles
-65°C to +100°C
12 cycles
-65°C to +100°C
Test data supplied at these temperatures[e]
-40°C, +80°C
2 years
-55°C, +80°C
2 years
Warranty
Environmental compliance
Derating
MIL-STD-810
NAVMAT P-4855-1A
MIL-STD-810
NAVMAT P-4855-1A
[e]
Test data available for review or download from vicorpower.com
ENVIRONMENTAL QUALIFICATIONS
Parameter
Qualification
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40 K ft.).
Altitude
MIL-STD-810D, Method 500.2, Procedure II, 40,000 ft., 1000 – 1500 ft./min. to 70,000 ft., unit functioning
MIL-STD-810C, Method 511.1, Procedure I
Explosive Atmosphere
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20 g
MIL-STD-810D, Method 514.3 random: 10 – 300 Hz @ 0.02 g2/Hz, 2000 Hz @ 0.002 g2/Hz, 3.9 total G rms
3 hrs/axis. Sine: 30 Hz @ 20 g, 60 Hz @ 10 g, 90 Hz @ 6.6 g, 120 Hz @ 5.0 g, 16.0 total G rms, 3 axes
Vibration
Shock
MIL-STD-810E, Method 514.4, Table 514.4-VII, 6 db/octave, 7.7 G rms, 1hr/axis
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40 g
MIL-STD-202F, Method 213B, 18 pulses, 60 g, 9 msec
MIL-STD-202F, Method 213B, 75 g, 11 ms saw tooth shock
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet
Acceleration
Humidity
MIL-STD-810D, Method 513.3, Procedure II Operational test, 9 g for 1 minute along 3 mutually perpendicular axes
MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity
MIL-STD-202, Method 208, 8 hr. aging
Solder Test
Fungus
MIL-STD-810C, Method 508.1
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Rev. 1.4
Page 4 of 6
Set your site on VICOR at vicorpower.com
MECHANICAL DRAWING
4.60
(116,8)
0.080 (2,0) Dia (2) places
Solder plate over copper alloy
3.60
.50
(12,7)
(91,4)
1.80
(45,7)
.30 .015
(7,6) (0,38)
Pin # Function
1
+In
2
3
4
5
6*
7*
8*
9
Gate In
Gate Out
-In
+Out
+Sense
Trim
4
3
9
8
7
6
2.10
(53,3)
1.40
MI-200
(35,6)
(25,4)
1.00
.70
2
1
(17,8)
(10,2)
.40
5
.35 .015
(8,9) (0,38)
-Sense
-Out
* Do not connect on booster modules
FULL R
.15
(3,8)
.040 (1,0) Dia (7) places
.15
(3,8)
Product ID
this surface
Solder plate over copper alloy
2.40
(61,0)
.30
(7,6) Min
4.20
(106,7)
1.75
.22
(5,6) MIN
Max.
(44,5)
.50
(12,7)
+.030 (0,76)
-.000 (0)
.01
.12
(3,0)
Aluminum Base
Note: For alternate packaging options refer to the mechanical drawing page of vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Rev. 1.4
Page 5 of 6
Set your site on VICOR at vicorpower.com
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance.
Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned
without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the
factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed
for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function,
or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it con-
vey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its compo-
nents in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and
Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor
against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunc-
tion could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon
request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-200 DC-DC Converters 50 to 100 Watts
Rev. 1.4
04/11
Set your site on VICOR at vicorpower.com
MI-264MX-F1 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
MI-264MX-F3 | VICOR | 1-OUTPUT 75W DC-DC REG PWR SUPPLY MODULE, MODULE-9 | 获取价格 | |
MI-264MX-F4 | VICOR | 1-OUTPUT 75W DC-DC REG PWR SUPPLY MODULE, MODULE-9 | 获取价格 | |
MI-264MY | XPPOWER | Analog Circuit | 获取价格 | |
MI-264MY | VICOR | 1-OUTPUT 50W DC-DC REG PWR SUPPLY MODULE, PLASTIC, MODULE-9 | 获取价格 | |
MI-264MY-F4 | VICOR | 1-OUTPUT 50W DC-DC REG PWR SUPPLY MODULE, MODULE-9 | 获取价格 | |
MI-264MY-S | VICOR | 1-OUTPUT 50W DC-DC REG PWR SUPPLY MODULE, MODULE-9 | 获取价格 | |
MI-26J-IV | VICOR | Military DC-DC Converters 50 to 100W | 获取价格 | |
MI-26J-IV | POWERBOX | 50-100 WATTS MILITARY COTS DC/DC CONVERTER | 获取价格 | |
MI-26J-IW | VICOR | Military DC-DC Converters 50 to 100W | 获取价格 | |
MI-26J-IW | POWERBOX | 50-100 WATTS MILITARY COTS DC/DC CONVERTER | 获取价格 |
MI-264MX-F1 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6