MI-B5L-MX [VICOR]
DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid,;型号: | MI-B5L-MX |
厂家: | VICOR CORPORATION |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, |
文件: | 总2页 (文件大小:250K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TM
MI-200
Military COTS DC-DC Converters 50 to 100 W
Features
ꢀ
Inputs:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Current limit
28 Vdc per MIL-STD-704D/E
155 Vdc per MIL-STD-1399A
270 Vdc per MIL-STD-704D/E
OVP and thermal shut down
Power boosters for higher power outputs
ZVS/ZCS power architecture
Low noise FM control
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Single output: 2 – 48 Vdc
Up to 23 W/in3
MIL-STD-810 environments
Up to 90% efficiency
Remote sense
Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7 mm)
Product Highlights
The MI-Series is designed for
applications utilizing distributed
power architecuture based on
Vicor’s 1st Generation family of
zero-current/zero-voltage switching,
component level DC-DC converters.
Operating at frequencies in excess
of 1 MHz, the MI-Series offers
state-of-the-art performance in
terms of power density, efficiency,
noise, ease of use, and reliability.
Converter/Booster Specifications
(At T = 25°C, nominal line and 75% load, unless otherwise specified)
BP
PARAMETER
MIN
TYP
MAX
UNITS
TEST CONDITIONS
Input Characteristics
Input voltage range
See input voltage chart
No load power dissipation
1.35
2.0
Watts
Output Characteristics
Set point accuracy
Load/line regulation
0.5
0.05
0.2
1.0
0.2
0.5
% Vnom
% Vnom
% Vnom
%/°C
LL to HL, 10% to FL
LL to HL, NL to 10%
All units are manufactured in ISO
9001-registered facilities. Fully
encapsulated in Vicor’s industry
standard package enables the
MI-Series to meet MIL-STD-810
environmental requirements for
humidity, fungus, salt, fog,
Output temperature drift
Output noise - pp
0.01
1.0
0.02
1.5
% Vnom
mV
% Vnom
Vdc
Whichever is greater
20 MHz BW
}
100
150
110
Output voltage trimming(1)
Remote sense compensation
OVP set point(2)
Current limit
Short circuit current(3)
50
0.5
115
105
20
125
6
135
125
130
% Vnom
% Inom
% Inom
Latching
Auto restart
explosive atmosphere, acceleration,
vibration, and shock. (See page 32.)
Control Pin Characteristics
Gate in high threshold
Gate in low threshold
Gate In low current
Vdc
Vdc
mA
0.65
0.95
Standard features such as wide
output trimming/programming,
current limiting, remote sense,
output inhibit, and latching
OVP and OTP combine to offer
a high degree of protection,
versatility, and reliability for
power systems.
6
1.05
Power sharing accuracy
Isolation Characteristics
Isolation (input to output)
Isolation (output to baseplate)
Isolation (input to baseplate)
Input/output capacitance
3,000
500
1,500
V
V
V
rms
rms
rms
50
75
pF
Environmental (MIL-STD-810)
Altitude - method 500.2
Humidity - method 507.2
Acceleration - method 513.3
Vibration - method 514.3
Shock - method 516.3
70,000
86/240
9
20
40
feet
%/hours
g's
Procedure II
Procedure 1, cycle 1
Procedure 2
g's
g's
Procedure 1, category 6
Procedure 1
Reliability (MIL-HDBK-217F)
25°C Ground Benign: G.B.
50°C Naval Sheltered: N.S.
2,478,477
584,920
483,303
hours
hours
hours
65°C Airborne Inhabited Cargo: A.I.C.
Thermal Characteristics
Efficiency
Baseplate to sink
Thermal shut down
Baseplate operating temperature
Storage temperature
80-90
0.07
95
%
°C/W
°C
°C
°C
With thermal pads
Latching
See product grade
See product grade
90
105
+85
+100
Mechanical Specifications
Weight
6.0 (170)
ounces (grams)
(1)
(2)
10 V, 12 V, and 15 V outputs, standard trim range 10%ꢀ Consult factory for wider trim rangeꢀ
No over temperature or voltage protection in booster modulesꢀ
(3) Output voltages of 5 V or less incorporate foldback current limiting; outputs of 10 V and above provide
constant current limitingꢀ
4
Configuration Chart
Output Voltage
T = 6.5 V
Input Voltage
MI-2
Semi-custom driver and booster
-
Z = 2 V
N = 18.5 V
3 = 24 V
L = 28 V
J = 36 V
K = 40 V
4 = 48 V
Nominal
Range
Transient
Y = 3.3 V
0 = 5 V
R = 7.5 V
2
5
6
7
=
28 V
18 – 50 V(1)
100 – 210 V
125 – 400 V(2)
100 – 310 V
60 V
230 V
475 V
modules available: Consult factory.
= 155 V
= 270 V
= 165 V
M= 10 V
(1) 16 V operation at 75% load.
X = 5.2 V
W= 5.5 V
V = 5.8 V
1 = 12 V
(2) These units rated at 75%
load from 125-150 Vin:
MI-26Z-xV
P = 13.8 V
2 = 15 V
MI-26Y-xV
MI-260-xW
Product Grade
Operating Temp.
Output Power/Current
28 Vdc input per MIL-STD 704D/E
155 Vdc input per DOD-STD-1399A
270 Vdc input per MIL-STD-704D/E
≥ 5 V
<5 V
I
=
=
-40°C to +85°C
-55°C to +85°C
M
Y
X
W
V
=
=
=
=
50 W
75 W
100 W
—o
10 A
15 A
20 A
30 A
For additional power, 100 W and 75 W booster
modules available. Change MI-2xx-xx to MI-Bxx-xx.
Product Grade Specifications
PARAMETER
PRODUCT GRADE
I-Grade
M-Grade
Storage temperature
-55°C to +100°C
-40°C to +85°C
-65°C to +100°C
-55°C to +85°C
Operating temperature (baseplate)
Power cycling burn-in
12 hours, 25 cycles
96 hours, 200 cycles
Temperature cycled with power off
17°C per minute rate of change
12 cycles
-65°C to +100°C
12 cycles
-65°C to +100°C
Test data supplied at these temperatures*
-40°C, +80°C
-55°C, +80°C
Warranty
2 years
2 years
Environmental compliance
Derating
MIL-STD-810
MIL-STD-810
NAVMAT P-4855-1A
NAVMAT P-4855-1A
*
Test data available for review or download from vicorpowerꢀcom
Mechanical Drawing
MI-200 Mechanical Drawing
4.60
(116,8)
3.60
(91,4)
0.50
(12,7)
0.080 (2,0) Dia (2) places
Solder plate
over copper alloy
1.80
(45,7)
0.30±0.015
(7,6)±(0,38)
Pin # Function
1
+In
2
Gate In
Gate Out
-In
4
3
9
3
4
8
7
6
2.10
(53,3)
1.40
5
+Out
MI-200
(35,6)
(25,4)
1.00
0.70
6*
7*
8*
9
+Sense
Trim
2
1
(17,8)
(10,2)
0.40
5
0.35±0.015
(8,9)±(0,38)
-Sense
-Out
* Do not connect on
Booster modules
FULL R
0.15
(3,8)
0.040 (1,0) Dia (7) places
Solder plate
over copper alloy
0.15
(3,8)
Product ID
this surface
2.40
(61,0)
4.20
(106,7)
0.30
(7,6)Min
1.75
(44,5)
0.22
(5,6) MIN
+0.030 (0,76)
-0.000 (0)
0.50
(12,7)
.01
0.12
(3,0)
Aluminum Base
5
相关型号:
©2020 ICPDF网 联系我们和版权申明