MI-J2Z-IA-F2

更新时间:2025-07-09 13:42:38
品牌:VICOR
描述:DC-DC Regulated Power Supply Module, 1 Output, 10W, Hybrid,

MI-J2Z-IA-F2 概述

DC-DC Regulated Power Supply Module, 1 Output, 10W, Hybrid, 电源模块

MI-J2Z-IA-F2 规格参数

是否无铅: 含铅是否Rohs认证: 不符合
生命周期:Active包装说明:,
Reach Compliance Code:not_compliantECCN代码:EAR99
风险等级:5.85其他特性:REMOTE SHUTDOWN
模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE认证:CE
效率(主输出):90%高度:12.7 mm
最大输入电压:50 V最小输入电压:18 V
标称输入电压:28 VJESD-30 代码:R-PDMA-P9
JESD-609代码:e0长度:57.9 mm
最大电网调整率:0.5%最大负载调整率:0.5%
功能数量:1输出次数:1
端子数量:9最高工作温度:100 °C
最低工作温度:-40 °C最大输出电压:2.2 V
最小输出电压:1 V标称输出电压:2 V
封装主体材料:PLASTIC/EPOXY封装形状:RECTANGULAR
封装形式:MICROELECTRONIC ASSEMBLY峰值回流温度(摄氏度):NOT SPECIFIED
认证状态:Not Qualified纹波电压(主输出):0.05304 Vrms
子类别:Power Supply Modules表面贴装:NO
技术:HYBRID温度等级:INDUSTRIAL
端子面层:TIN LEAD OVER COPPER端子形式:PIN/PEG
端子位置:DUAL处于峰值回流温度下的最长时间:NOT SPECIFIED
最大总功率输出:10 W微调/可调输出:YES
宽度:61 mmBase Number Matches:1

MI-J2Z-IA-F2 数据手册

通过下载MI-J2Z-IA-F2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
Data Sheet  
MI-J00  
Features  
DC-DC Converters  
10 to 50 Watts  
• Inputs:  
28 Vdc per MIL-STD-704D/E/F  
155 Vdc per MIL-STD-1399A  
270 Vdc per MIL-STD-704D/E/F  
• Single output: 2 – 48 Vdc  
• Up to 23 W/in3  
• MIL-STD-810 environments  
• Up to 90% efficiency  
• Remote sense  
• Current limit  
• ZCS power architecture  
• Low noise FM control  
• Size: 2.28" x 2.4" x 0.5"  
(57,9 x 61,0 x 12,7 mm)  
Converter Selection Chart  
MI-J  
Semi-custom modules available, consult factory.  
Product Highlights  
The MI-J00 family of DC-DC converters is  
designed for applications utilizing distributed  
power architectures. Based on Vicor’s VI-200 /  
VI-J00 family of zero-current switching,  
component-level DC-DC converters, the MI-J00  
family offers exceptional performance in terms of  
power density, efficiency, noise, ease of use, and  
reliability.  
Input Voltage  
Nominal  
2 = 28 V  
5 = 155 V  
6 = 270 V  
7 = 165 V  
Range  
Transient [a]  
60 V  
Notes  
18 – 50 V [b]  
100 – 210 V  
125 – 400 V [c]  
100 – 310 V  
28 Vdc input per MIL-STD 704D/E/F  
155 Vdc input per MIL-STD-1399A  
270 Vdc input per MIL-STD-704D/E/F  
230 V  
475 V  
n/a  
The MI-J00 family meets all steady-state,  
transient andunder/overvoltage requirements of  
MIL-STD-704D/E/F for both 28 Vdc input  
(MI-J2X) and 270 Vdc input (MI-J6X), and the  
worst case envelope of MIL-STD-1399A for  
155 Vdc input (MI-J5X).  
[a]  
Transient voltage for 1 second.  
16 V operation at 75% load.  
These units rated at 75% load from 125 – 150 Vin: MI-J6Z-xY, MI-J6Y-xY, MI-J60-xY  
[b]  
[c]  
Output Voltage  
Product Grade Temperatures (°C)  
The output voltage can be externally trimmed or  
programmed from 50% to 110% of nominal  
output. Current limiting, remote sense, and an  
inhibit pin all combine to offer a high degree of  
protection, versatility, and reliability for power  
systems.  
Operating  
Storage  
Z = 2.0 V  
Y = 3.3 V  
0 = 5.0 V  
X = 5.2 V  
W = 5.5 V  
V = 5.8 V  
T = 6.5 V  
R = 7.5 V  
M = 10 V  
1 = 12 V  
I = 40 to +100  
M = 55 to +100  
I = 55 to +125  
M = 65 to +125  
P = 13.8 V  
2 = 15 V  
N = 18.5 V  
3 = 24 V  
L = 28 V  
J = 36 V  
K = 40 V  
4 = 48 V  
Fully encapsulated in Vicor’s industry standard  
package, the MI-J00 family meets MIL-STD-810  
environmental testing requirements for humidity,  
fungus, salt-fog, explosive atmosphere,  
Output Power/Current Vout  
5 V  
<5 V  
A = 10 W  
Z = 25 W  
Y = 50 W  
A = —  
Z = 5 A  
Y = 10 A  
acceleration, vibration, and shock.  
Packaging Options  
Standard: Slotted baseplate  
SlimMod: Flangeless baseplate, option suffix: - S  
Example: MI - JXX - XX - S  
FinMod: Finned heat sink, option suffix:  
- F1, -F2, -F3 and - F4  
Examples:  
MI - JXX - XX -F1, 0.25" fins, longitudinal  
MI - JXX - XX -F2, 0.50" fins, longitudinal  
MI - JXX - XX -F3, 0.25" fins, transverse  
MI - JXX - XX -F4, 0.50" fins, transverse  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MI-200 DC-DC Converters 10 to 50 Watts  
Rev. 1.0  
Page 1 of 6  
Set your site on VICOR at www.vicorpower.com  
CONVERTER SPECIFICATIONS  
(typical at T = 25°C, nominal line and 75% load, unless otherwise specified)  
BP  
INPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Units  
Test Conditions  
Inrush charge  
60 x10-6  
100 x 10-6  
Coulombs  
Nominal line  
Input reflected  
ripple current – pp  
10%  
IIN  
Nominal line, full load  
Vin  
30+20Log  
(
(
)
)
dB  
120 Hz, nominal line  
2400 Hz, nominal line  
Vout  
Input ripple rejection  
Vin  
Vout  
20+20Log  
dB  
No load power dissipation  
1.35  
2
Watts  
OUTPUT CHARACTERISTICS  
Parameter  
Min  
Typ  
0.5  
Max  
1
Units  
%VNOM  
%VNOM  
%VNOM  
% / °C  
Test Conditions  
Setpoint accuracy  
0.05  
0.2  
0.2  
0.5  
0.02  
LL to HL, 10% to Full Load  
LL to HL, No Load to 10%  
Over rated temperature  
Load/line regulation  
Output temperature drift  
Long term drift  
0.01  
0.02  
100  
%/1K hours  
mV  
150  
1.5  
Whichever is greater  
20 MHz bandwidth  
Output ripple – pp  
1.0  
%VNOM  
%VNOM  
Trim range[a]  
50  
110  
Total remote  
sense compensation  
0.5  
Volts  
Current limit  
105  
105  
125  
130  
%INOM  
%INOM  
Automatic restart  
Short circuit current  
[a]  
10 V, 12 V and 15 V outputs, standard trim range 10%. Consult factory for wider trim range.  
CONTROL PIN SPECIFICATIONS  
Parameter  
Min  
Typ  
50  
Max  
Units  
Test Conditions  
Gate out impedance  
Gate in impedance  
Gate in high threshold  
Gate in low threshold  
Gate in low current  
1000  
6
6
Volts  
Volts  
mA  
Use open collector  
0.65  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MI-J00 DC-DC Converters 10 to 50 Watts  
Rev. 1.0  
Page 2 of 6  
Set your site on VICOR at www.vicorpower.com  
CONVERTER SPECIFICATIONS (cont.)  
DIELECTRIC WITHSTAND CHARACTERISTICS  
Parameter  
Min  
3,000  
500  
Typ  
Max  
Units  
VRMS  
VRMS  
VRMS  
pF  
Test Conditions  
Input to output  
Baseplate earthed  
Output to baseplate  
Input to baseplate  
Input to output capacitance  
1,500  
50  
75  
THERMAL CHARACTERISTICS  
Parameter  
Min  
Typ  
80 – 90%  
0.14  
Max  
Units  
Test Conditions  
Efficiency  
Baseplate to sink  
°C/Watt  
With thermal pads  
ENVIRONMENTAL – MIL-STD-810D  
Parameter  
Min  
70,000  
88/240  
9
Typ  
Max  
Units  
Test Conditions  
Procedure II  
Altitude - method 500.2  
Humidity - method 507.2  
Acceleration - method 513.3  
Vibration - method 514.3  
Shock - method 516.3  
feet  
%/hours  
Procedure I, cycle 1  
Procedure II  
g
g
g
20  
Procedure I, category 6  
Procedure I  
40  
RELIABILITY - MIL-HDBK-217F (MI-J2L-MY)  
Parameter  
Min  
Typ  
3,732  
672  
Max  
Units  
Test Conditions  
25°C Ground Benign: G.B.  
50°C Naval Sheltered: N.S.  
1,000 hours  
1,000 hours  
65°C Airborne Inhabited  
Cargo: A.I.C.  
526  
1,000 hours  
MECHANICAL SPECIFICATIONS  
Parameter Min  
Weight  
Typ  
Max  
Units  
Test Conditions  
3.0  
(85)  
Ounces  
(Grams)  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MI-200 DC-DC Converters 10 to 50 Watts  
Rev. 1.0  
Page 3 of 6  
Set your site on VICOR at www.vicorpower.com  
CONVERTER SPECIFICATIONS (cont.)  
PRODUCT GRADE SPECIFICATIONS  
Parameter  
I-Grade  
M-Grade  
Storage temperature  
Operating temperature (baseplate)  
Power cycling burn-in  
-55°C to +125°C  
-40°C to +100°C  
12 hours, 29 cycles  
-65°C to +125°C  
-55°C to +100°C  
96 hours, 213 cycles  
Temperature cycled with power off  
17°C per minute rate of change  
12 cycles  
-65°C to +100°C  
12 cycles  
-65°C to +100°C  
Test data supplied at these temperatures[a]  
-40°C, +80°C  
2 years  
-55°C, +80°C  
2 years  
Warranty  
Environmental compliance  
Derating  
MIL-STD-810  
NAVMAT P-4855-1A  
MIL-STD-810  
NAVMAT P-4855-1A  
[a] Test data available for review or download from vicorpower.com  
ENVIRONMENTAL QUALIFICATIONS  
Parameter  
Qualification  
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40 K ft.).  
Altitude  
MIL-STD-810D, Method 500.2, Procedure II, 40,000 ft., 1000 – 1500 ft./min. to 70,000 ft., unit functioning  
MIL-STD-810C, Method 511.1, Procedure I  
Explosive Atmosphere  
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20 g  
MIL-STD-810D, Method 514.3 random: 10 – 300 Hz @ 0.02 g2/Hz, 2000 Hz @ 0.002 g2/Hz, 3.9 total G rms  
3 hrs/axis. Sine: 30 Hz @ 20 g, 60 Hz @ 10 g, 90 Hz @ 6.6 g, 120 Hz @ 5.0 g, 16.0 total G rms, 3 axes  
Vibration  
Shock  
MIL-STD-810E, Method 514.4, Table 514.4-VII, 6 db/octave, 7.7 G rms, 1hr/axis  
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40 g  
MIL-STD-202F, Method 213B, 18 pulses, 60 g, 9 msec  
MIL-STD-202F, Method 213B, 75 g, 11 ms saw tooth shock  
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet  
MIL-STD-810D, Method 513.3, Procedure II Operational test, 9 g for 1 minute along 3 mutually perpendicular axes  
MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity  
MIL-STD-202, Method 208, 8 hr. aging  
Acceleration  
Humidity  
Solder Test  
Fungus  
MIL-STD-810C, Method 508.1  
Salt-Fog  
MIL-STD-810C, Method 509.1  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MI-J00 DC-DC Converters 10 to 50 Watts  
Rev. 1.0  
Page 4 of 6  
Set your site on VICOR at www.vicorpower.com  
MECHANICAL DRAWING  
2.28  
(57,9)  
1.30  
(33,0)  
.49  
(12,4)  
0.080 Dia (2) places  
Solder plate  
.65  
(16,5)  
over copper alloy  
.30±.015  
(7,6)±(0,38)  
Pin #  
Function  
+In  
1
2
3
4
5
6
7
8
4
3
9
Gate In  
Gate Out  
-In  
8
7
6
2.10  
(53,4)  
1.40  
MI-J00  
(35,6)  
1.00  
+Out  
.70  
(17,8)  
(25,4)  
2
1
.40  
(10,2)  
+Sense  
Trim  
5
.35± .015  
(8,9)±(0,38)  
–Sense  
–Out  
9
FULL R  
.15  
(3,8)  
0.040 (1,0) Dia (7) places  
Solder plate  
.15  
(3,8)  
over copper alloy  
2.40  
(61,0)  
Product ID  
this surface  
1.90  
(48,3)  
1.75  
(44,4) Max.  
.30  
(7,6) Min.  
.22  
(5,6) Min.  
+.030 (0,76)  
-.000 (0)  
.50  
(12,7)  
.01  
.12  
(3,0)  
Aluminum Base  
Note: For alternate package options refer to the mechanical drawing page of vicorpower.com  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MI-200 DC-DC Converters 10 to 50 Watts  
Rev. 1.0  
Page 5 of 6  
Set your site on VICOR at www.vicorpower.com  
Warranty  
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal  
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance.  
Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only.  
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,  
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE.  
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the  
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned  
without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the  
factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.  
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed  
for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function,  
or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it con-  
vey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its compo-  
nents in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and  
Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor  
against all damages.  
Vicor s comprehensive line of power solutions includes high density AC-DC  
and DC-DC modules and accessory components, fully configurable AC-DC  
and DC-DC power supplies, and complete custom power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its  
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunc-  
tion could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon  
request.  
Specifications are subject to change without notice.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent  
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual  
Property Department.  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
Fax: 978-475-6715  
email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MI-J00 DC-DC Converters 10 to 50 Watts  
Rev. 1.0  
3/07  
Set your site on VICOR at www.vicorpower.com  

MI-J2Z-IA-F2 相关器件

型号 制造商 描述 价格 文档
MI-J2Z-IA-F4 VICOR DC-DC Regulated Power Supply Module, 1 Output, 10W, Hybrid, 获取价格
MI-J2Z-IA-S VICOR DC-DC Regulated Power Supply Module, 1 Output, 10W, Hybrid, 获取价格
MI-J2Z-IJ POWERBOX 10-50 WATTS MILITARY COTS DC/DC CONVERTER 获取价格
MI-J2Z-IY VICOR Military DC-DC Converters 10 to 50W 获取价格
MI-J2Z-IY POWERBOX 10-50 WATTS MILITARY COTS DC/DC CONVERTER 获取价格
MI-J2Z-IY-F1 VICOR DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, 获取价格
MI-J2Z-IY-F2 VICOR DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, 获取价格
MI-J2Z-IY-F3 VICOR DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, 获取价格
MI-J2Z-IY-F4 VICOR DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, 获取价格
MI-J2Z-IY-S VICOR DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, 获取价格
Hi,有什么可以帮您? 在线客服 或 微信扫码咨询