是否无铅: 含铅是否Rohs认证: 不符合
生命周期:ActiveReach Compliance Code:not_compliant
ECCN代码:EAR99风险等级:5.85
其他特性:REMOTE SHUTDOWN模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE
认证:CE效率(主输出):90%
高度:12.7 mm最大输入电压:310 V
最小输入电压:100 V标称输入电压:165 V
JESD-30 代码:R-PDMA-P9JESD-609代码:e0
长度:57.9 mm最大电网调整率:0.5%
最大负载调整率:0.5%功能数量:1
输出次数:1端子数量:9
最高工作温度:100 °C最低工作温度:-40 °C
最大输出电压:30.8 V最小输出电压:14 V
标称输出电压:28 V封装主体材料:PLASTIC/EPOXY
封装形状:RECTANGULAR封装形式:MICROELECTRONIC ASSEMBLY
峰值回流温度(摄氏度):NOT SPECIFIED认证状态:Not Qualified
纹波电压(主输出):0.05304 Vrms子类别:Power Supply Modules
表面贴装:NO技术:HYBRID
温度等级:INDUSTRIAL端子面层:TIN LEAD OVER COPPER
端子形式:PIN/PEG端子位置:DUAL
处于峰值回流温度下的最长时间:NOT SPECIFIED最大总功率输出:10 W
微调/可调输出:YES宽度:61 mm
Base Number Matches:1

MI-J7L-IA-S 数据手册

通过下载MI-J7L-IA-S数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
DC-DC Converters  
MI-J00  
10 to 50 Watts  
Features & Benefits  
Packaging Options  
Inputs:  
Standard: Slotted baseplate  
28VDC per MIL-STD-704D/E/F  
155VDC per MIL-STD-1399A  
270VDC per MIL-STD-704D/E/F  
SlimMod: Flangeless baseplate, option suffix: - S  
Example: MI - JXX - XX - S  
Single output: 2 – 48VDC  
Up to 23W/in3  
FinMod: Finned heat sink, option suffix:  
- F1, -F2, -F3 and - F4  
MIL-STD-810 environments  
Up to 90% efficiency  
Remote sense  
Examples:  
MI - JXX - XX -F1, 0.25” fins, longitudinal  
MI - JXX - XX -F2, 0.50” fins, longitudinal  
MI - JXX - XX -F3, 0.25” fins, transverse  
MI - JXX - XX -F4, 0.50” fins, transverse  
Current limit  
ZCS power architecture  
Low noise FM control  
Converter Selection Chart  
Size: 2.28” x 2.4” x 0.5”  
(57,9 x 61,0 x 12,7mm)  
MI-J  
Semi-custom modules available, consult factory.  
Product Highlights  
Input Voltage  
The MI-J00 family of DC-DC converters is  
designed for applications utilizing distributed  
power architectures. Based on Vicor’s VI-200  
/ VI-J00 family of zero-current switching,  
component-level DC-DC converters, the MI-J00  
family offers exceptional performance in terms  
of power density, efficiency, noise, ease of use,  
and reliability.  
Nominal  
2 = 28V  
Range  
Transient [a]  
60V  
Notes  
[b]  
18 – 50V  
28VDC input per MIL-STD 704D/E/F  
155VDC input per MIL-STD-1399A  
270VDC input per MIL-STD-704D/E/F  
5 = 155V  
6 = 270V  
7 = 165V  
100 – 210V  
125 – 400V  
100 – 310V  
230V  
[c]  
475V  
n/a  
The MI-J00 family meets the steady-state input  
voltage requirements of MIL-STD-704D/E/F for  
the 28VDC (MI-J2X) and 270VDC input (MI-J6X).  
The 155VDC input (MI-J5X) meets MIL-STD-1399A.  
When used with the MI-IAM input attenuator  
module, the 28V or 270V input MI-J00 converter  
meets the transient and spike requirements of  
MIL-STD-704, MIL STD-1275, and DO-160. Please  
refer to the MI-IAM data sheet for details.  
[a] Transient voltage for 1 second.  
[b] 16V operation at 75% load.  
[c] These units rated at 75% load from 125 – 150VIN: MI-J6Z-xY, MI-J6Y-xY, MI-J60-xY  
Output Voltage  
Product Grade Temperatures (°C)  
Operating  
Storage  
Z = 2.0V  
1 = 12V  
P = 13.8V  
2 = 15V  
N = 18.5V  
3 = 24V  
L = 28V  
J = 36V  
K = 40V  
4 = 48V  
I
= 40 to +100  
= 55 to +100  
I = 55 to +125  
M = 65 to +125  
Y = 3.3V  
0 = 5.0V  
X = 5.2V  
W = 5.5V  
V = 5.8V  
T = 6.5V  
R = 7.5V  
M = 10V  
The output voltage can be externally trimmed  
or programmed from 50% to 110% of nominal  
output. Current limiting, remote sense, and an  
inhibit pin all combine to offer a high degree of  
protection, versatility, and reliability for  
power systems.  
M
Output Power/Current VOUT  
5V  
<5V  
Fully encapsulated in Vicor’s industry standard  
package, the MI-J00 family meets MIL-STD-810  
environmental testing requirements for humidity,  
fungus, salt-fog, explosive atmosphere,  
A = 10W  
Z = 25W  
Y = 50W  
A = —  
Z = 5A  
Y = 10A  
acceleration, vibration, and shock.  
MI-J00 DC-DC Converters  
Page 1 of 7  
Rev 1.4  
06/2017  
vicorpower.com  
800 927.9474  
MI-J00  
Converter Specifications  
(Typical at TBP =25°C, nominal line and 75% load, unless otherwise specified)  
Input Specifications  
Parameter  
Min  
Typ  
Max  
Units  
Test Conditions  
Inrush charge  
60 x10-6  
100 x10-6  
Coulombs  
Nominal line  
Input reflected  
10%  
IIN  
Nominal line, full load  
ripple current – pp  
VIN  
VOUT  
30+20Log  
(
(
)
)
dB  
120Hz, nominal line  
2400Hz, nominal line  
Input ripple rejection  
VIN  
VOUT  
20+20Log  
dB  
No load power dissipation  
Output Characteristics  
1.35  
2
Watts  
Parameter  
Min  
Typ  
0.5  
Max  
1
Units  
%VNOM  
%VNOM  
%VNOM  
% / °C  
Test Conditions  
Setpoint accuracy  
0.05  
0.2  
0.2  
0.5  
0.02  
LL to HL, 10% to Full Load  
LL to HL, No Load to 10%  
Over rated temperature  
Load/line regulation  
Output temperature drift  
Long term drift  
0.01  
0.02  
100  
%/1K hours  
mV  
150  
1.5  
Whichever is greater  
20MHz bandwidth  
Output ripple – pp  
1.0  
%VNOM  
%VNOM  
[a]  
Trim range  
50  
110  
Total remote  
0.5  
Volts  
sense compensation  
Current limit  
105  
105  
125  
130  
%INOM  
%INOM  
Automatic restart  
Short circuit current  
[a] 10V to 15V outputs, standard trim range 10%. Consult factory for wider trim range.  
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,  
please refer to output connections on page 5.  
Control Pin Specifications  
Parameter  
Min  
Typ  
50  
Max  
Units  
Ω
Test Conditions  
Gate out impedance  
Gate in impedance  
Gate in high threshold  
Gate in low threshold  
Gate in low current  
1000  
Ω
6
6
Volts  
Volts  
mA  
Use open collector  
0.65  
MI-J00 DC-DC Converters  
Page 2 of 7  
Rev 1.4  
06/2017  
vicorpower.com  
800 927.9474  
MI-J00  
Converter Specifications (Cont.)  
(Typical at TBP =25°C, nominal line and 75% load, unless otherwise specified)  
Dielectric Withstand Characteristics  
Parameter  
Min  
3,000  
500  
Typ  
Max  
Units  
VRMS  
VRMS  
VRMS  
pF  
Test Conditions  
Input to output  
Baseplate earthed  
Output to baseplate  
Input to baseplate  
Input to output capacitance  
1,500  
50  
75  
Thermal Characteristics  
Parameter  
Efficiency  
Min  
Typ  
80 – 90%  
0.14  
Max  
Units  
Test Conditions  
Baseplate to sink  
°C/Watt  
With thermal pads  
Enviornmental – MIL-STD-810D  
Parameter  
Min  
Typ  
Max  
Units  
Test Conditions  
Procedure II  
Altitude - method 500.2  
Humidity - method 507.2  
Acceleration - method 513.3  
Vibration - method 514.3  
Shock - method 516.3  
70,000  
88/240  
9
feet  
%/hours  
Procedure I, cycle 1  
Procedure II  
g
g
g
20  
Procedure I, category 6  
Procedure I  
40  
Reliability – MIL-HDBK-217F (MI-J2L-MY)  
Parameter  
Min  
Typ  
3,732  
672  
Max  
Units  
Test Conditions  
25°C Ground Benign: G.B.  
50°C Naval Sheltered: N.S.  
1,000 hours  
1,000 hours  
65°C Airborne Inhabited  
Cargo: A.I.C.  
526  
1,000 hours  
Mechanical Specifications  
Parameter  
Min  
Typ  
Max  
Units  
Test Conditions  
3.5  
3.7  
3.8  
Ounces  
Grams  
Weight  
101  
107  
109  
MI-J00 DC-DC Converters  
Page 3 of 7  
Rev 1.4  
06/2017  
vicorpower.com  
800 927.9474  
MI-J00  
Converter Specifications (Cont.)  
Product Grade Specifications  
Parameter  
I-Grade  
M-Grade  
Storage temperature  
Operating temperature (baseplate)  
Power cycling burn-in  
-55°C to +125°C  
-40°C to +100°C  
12 hours, 29 cycles  
-65°C to +125°C  
-55°C to +100°C  
96 hours, 213 cycles  
Temperature cycled with power off  
17°C per minute rate of change  
12 cycles  
12 cycles  
-65°C to +100°C  
-65°C to +100°C  
Test data supplied at these temperatures[a]  
-40°C, +80°C  
2 years  
-55°C, +80°C  
2 years  
Warranty  
Environmental compliance  
MIL-STD-810  
MIL-STD-810  
Derating  
NAVMAT P-4855-1A  
NAVMAT P-4855-1A  
[a] Test data available for review or download from vicorpower.com  
Maximum Capacitance, Rated Output Voltage <5V  
Rated VOUT (V)  
2 to <3  
IOUT Rating (A)  
CMAX (µF)  
1500  
IOUT Rating (A)  
>10 to 20  
CMAX (µF)  
5000  
10  
10  
3 to <5  
1000  
>10 to 20  
5000  
Maximum Capacitance, Rated Output Voltage 5V  
Rated VOUT (V)  
5 to <7.5  
7.5 to <10  
10 to <28  
>28  
POUT Rating (W)  
CMAX (µF)  
1000  
400  
POUT Rating (W)  
>50 to 100  
CMAX (µF)  
1500  
700  
50  
50  
50  
50  
>50 to 100  
400  
>50 to 100  
500  
150  
>50 to 100  
250  
Enviornmental Qualifications  
Parameter  
Qualification  
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40K ft.).  
Altitude  
MIL-STD-810D, Method 500.2, Procedure II, 40,000ft., 1000 – 1500ft./min. to 70,000ft., unit functioning  
MIL-STD-810C, Method 511.1, Procedure I  
Explosive Atmosphere  
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20g  
MIL-STD-810D, Method 514.3 random: 10 – 300Hz @ 0.02g2/Hz, 2000Hz @ 0.002g2/Hz, 3.9 total Grms  
3 hrs/axis. Sine: 30Hz @ 20g, 60Hz @ 10g, 90Hz @ 6.6g, 120Hz @ 5.0g, 16.0 total Grms, 3 axes  
Vibration  
Shock  
MIL-STD-810E, Method 514.4, Table 514.4-VII, 6db/octave, 7.7Grms, 1hr/axis  
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40g  
MIL-STD-202F, Method 213B, 18 pulses, 60g, 9ms  
MIL-STD-202F, Method 213B, 75g, 11ms saw tooth shock  
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet  
MIL-STD-810D, Method 513.3, Procedure II Operational test, 9g for 1 minute along 3 mutually perpendicular axes  
MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240hrs, 88% relative humidity  
MIL-STD-202, Method 208, 8hr. aging  
Acceleration  
Humidity  
Solder Test  
Fungus  
MIL-STD-810C, Method 508.1  
Salt-Fog  
MIL-STD-810C, Method 509.1  
MI-J00 DC-DC Converters  
Page 4 of 7  
Rev 1.4  
06/2017  
vicorpower.com  
800 927.9474  
MI-J00  
Basic Module Operation  
C2a  
C2b  
C1a  
C1b  
F1  
C3  
+IN  
–IN  
ZeSrwoitCcuhrinregnt+OUT  
Converter  
–OUT  
400  
C3 (µF) =  
VIN Minimum  
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Design Guide & Applications Manual.  
Output Connections and Considerations  
The permissible load current[e] must never be exceeded during  
normal, abnormal or test conditions. Converters subject to  
dynamic loading exceeding 25% of rated current must be  
Storage  
Vicor products, when not installed in customer units, should  
be stored in ESD safe packaging in accordance with  
ANSI/ESD S20.20, “Protection of Electrical and Electronic  
reviewed by Vicor Applications Engineering to ensure that the  
Parts, Assemblies and Equipment” and should be maintained  
converter will operate properly.  
in a temperature controlled factory/warehouse environment  
Under dynamic load, light load, or no load conditions, the  
converter may emit audible noise. Converters that utilize remote  
sense may require compensation circuitry to offset the phase  
lag caused by the external output leads and load impedance.  
Remote Sense leads must be protected for conditions such as  
lead reversal, noise pickup, open circuit, or excessive output lead  
resistance between the sense point and the converters output  
terminals. For applications that may draw more than the rated  
current, a fast acting electronic circuit breaker must be utilized  
to protect the converter. Under no circumstance should the  
rated current be exceeded. Utilizing or testing of current limit or  
short circuit current will damage the converter. Ensure that the  
total output capacitance connected to the converter does not  
exceed the limits on Page 4.  
not exposed to outside elements controlled between the  
temperature ranges of 15ºC and 38ºC. Humidity shall not be  
condensing, no minimum humidity when stored in an ESD  
compliant package.  
Nominal Power Rating  
[e] Permissible load current:  
Nominal VOUT  
MI-J00 DC-DC Converters  
Page 5 of 7  
Rev 1.4  
06/2017  
vicorpower.com  
800 927.9474  
MI-J00  
Mechanical Drawing  
2.28  
(57,9)  
Standard  
1.30  
.49  
0.080 Dia (2) places  
(33,0)  
(12,4)  
.65  
Solder plate  
(16,5)  
over copper alloy  
.30±.015  
(7,6)±(0,38)  
Pin #  
Function  
+In  
Gate In  
Gate Out  
-In  
+Out  
+Sense  
Trim  
–Sense  
–Out  
1
2
3
4
5
6
7
8
4
3
9
8
7
6
2.10  
1.40  
MI-J00  
(53,4)  
(35,6)  
1.00  
.70  
(17,8)  
(25,4)  
2
1
.40  
(10,2)  
5
.35± .015  
(8,9)±(0,38)  
9
RoHS  
FULL R  
.15  
0.040 (1,0) Dia (7) places  
Solder plate  
(3,8)  
.15  
(3,8)  
over copper alloy  
2.40  
Product ID  
this surface  
(61,0)  
1.90  
(48,3)  
1.75  
(44,4) Max.  
.30  
(7,6) Min.  
.22  
(5,6) Min.  
+.030 (0,76)  
.50  
-.000 (0)  
(12,7)  
.01  
.12  
(3,0)  
Aluminum Base  
Note: For alternate package options refer to the mechanical drawing page of vicorpower.com  
MI-J00 DC-DC Converters  
Page 6 of 7  
Rev 1.4  
06/2017  
vicorpower.com  
800 927.9474  
MI-J00  
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and  
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom  
power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor  
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves  
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by  
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.  
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where  
mandated by government requirements, testing of all parameters of each product is not necessarily performed.  
Specifications are subject to change without notice.  
Visit http://www.vicorpower.com/vi-200_vi-j00 for the latest product information.  
Vicor’s Standard Terms and Conditions and Product Warranty  
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage  
(http://www.vicorpower.com/termsconditionswarranty) or upon request.  
Life Support Policy  
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE  
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used  
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and  
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to  
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform  
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms  
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies  
Vicor against all liability and damages.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the  
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property  
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
Fax: 978-475-6715  
email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
MI-J00 DC-DC Converters  
Page 7 of 7  
Rev 1.4  
06/2017  
vicorpower.com  
800 927.9474  

MI-J7L-IA-S 相关器件

型号 制造商 描述 价格 文档
MI-J7L-IY VICOR Military DC-DC Converters 10 to 50W 获取价格
MI-J7L-IY POWERBOX 10-50 WATTS MILITARY COTS DC/DC CONVERTER 获取价格
MI-J7L-IY-F1 VICOR CONVERT DC/DC 165VIN 28VOUT 50W 获取价格
MI-J7L-IY-F2 VICOR CONVERT DC/DC 165VIN 28VOUT 50W 获取价格
MI-J7L-IY-F3 VICOR 暂无描述 获取价格
MI-J7L-IY-F4 VICOR DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, 获取价格
MI-J7L-IY-S VICOR CONVERT DC/DC 165VIN 28VOUT 50W 获取价格
MI-J7L-IZ VICOR Military DC-DC Converters 10 to 50W 获取价格
MI-J7L-IZ POWERBOX 10-50 WATTS MILITARY COTS DC/DC CONVERTER 获取价格
MI-J7L-IZ-F1 VICOR CONVERT DC/DC 165VIN 28VOUT 25W 获取价格

MI-J7L-IA-S 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    5
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    8
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6