PS48M3V3DTF1 [VICOR]

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, 2.280 X 0.500 INCH, 0.350 INCH HEIGHT, MODULE-9;
PS48M3V3DTF1
型号: PS48M3V3DTF1
厂家: VICOR CORPORATION    VICOR CORPORATION
描述:

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, 2.280 X 0.500 INCH, 0.350 INCH HEIGHT, MODULE-9

文件: 总8页 (文件大小:260K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
P R E L I M I N A R Y  
PowerStick DC-DC Converters  
Data Sheet  
45  
Features  
Low Profile, Integral Cooling  
Up to 75W  
DC input range: 36 – 75V  
DC outputs: 1.5 to 12V  
Low profile: 0.350'' above board height  
Multiple fin configurations  
Effective power density: Up to 188W/in3  
Parallelable, with N+M fault tolerance  
Low noise ZCS/ZVS architecture  
Input surge withstand: 100V for 100ms  
Typical Applications  
Typical applications include communications,  
data processing, test equipment, industrial  
applications and distributed power systems.  
Absolute Maximum Ratings  
Product Overview  
Parameter  
Rating  
-0.5 to +75  
100  
Unit  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
°C  
Notes  
PowerStick features an above board height of  
only 0.35'' and a footprint as small as 2.28''L x  
0.5''W. PowerStick converters deliver up to  
75 Watts per module and up to 900 Watts in  
fault-tolerant arrays.  
+In to –In voltage  
+In to –In voltage  
<100ms  
PC to –In voltage  
-0.5 to +7.0  
-0.5 to +7.0  
-0.5 to +1.5  
1.0  
PR to –In voltage  
SC to –Out voltage  
Vicor’s innovative through-the-board mounting  
results in an effective power conversion density  
of 188W/in3. A wraparound aluminum body,  
available in a variety of options, provides integral  
cooling in a broad range of applications and  
thermal environments, allowing customers to  
achieve peak power density within the 0.35''  
low profile.  
–Sense to –Out voltage  
Isolation voltage (in to out)  
Isolation voltage (in to case)  
Isolation voltage (out to case)  
Storage temperature (C-Grade)  
Operating temperature (C-Grade)  
1500  
1500  
1500  
-40 to +125  
-20 to +100  
°C  
Case Temp.  
All members of the PowerStick family maintain  
the complete feature set of Vicor 2nd Generation  
converters. And, because PowerSticks are  
environmentally sealed and encased in aluminum,  
they offer superior ruggedness, reliability,  
electrical shielding and noise performance.  
Part Numbering  
PS 48  
M
3V3D  
C
S
Input Voltage  
Case Configuration  
See below and page 7  
Output Voltage  
1V5 = 1.5V, 15A  
1V5D = 1.5V, 10A  
1V8 = 1.8V, 15A  
1V8D = 1.8V, 10A  
2 = 2.0V, 15A  
Mounting  
Height  
M: 0.35''  
Low voltage models incorporate Vicor’s  
innovative Smart RectificationTM for high  
efficiency.  
2D = 2.0V, 10A  
2V5 = 2.5V, 15A  
2V5D = 2.5V, 10A  
3V3 = 3.3V, 15A  
3V3D = 3.3V, 10A  
5 = 5V, 12A  
Product Grade Temperatures (°C)  
Grade  
Storage  
Operating  
40 to +125 20 to +100  
40 to +125 -40 to +100  
C
T
=
=
-
-
-
12 = 12V, 75W  
S Case  
F1 Case  
F2 Case  
F3 Case  
F4 Case  
0.35''  
Above Board Height  
Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715  
Page 1  
For the most current data and applications support, visit vicr.com.  
P R E L I M I N A R Y  
ELECTRICAL CHARACTERISTICS  
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and case temperature,  
unless otherwise specified. All temperatures refer to the operating temperature at the top center of the case.  
MODULE OPERATING SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
75  
Unit  
Vdc  
Vdc  
Notes  
Operating input voltage  
Input surge withstand  
36  
48  
100  
<100ms  
MODULE OUTPUT VOLTAGE RELATED SPECIFICATIONS  
Parameter  
1.5 to 3.3V  
1%  
5V  
1%  
250  
60  
12V  
Unit  
Notes  
Output Voltage Setpoint  
Ripple and noise, p-p (typ.)  
Output Power (max.)  
Output Current (max.)  
1%  
160  
75  
Vout nom.  
mV  
Nominal Input, 75% load, 25°C  
Nominal Input; full load; 25°C, 20MHz BW  
At 100°C Case Temperature  
At 100°C Case Temperature  
180  
Watts  
Amps  
Volts  
10 or 15  
Output OVP setpoint (nom.) 115% Vnom +0.5  
6.3  
1.9  
0.3  
115  
14.3  
1.9  
Dissipation, standby (typ.)  
Load regulation (max.)  
Current limit (typ.)  
1.8  
0.3  
115  
Watts  
% Vout  
% Iout  
No load; nominal input  
0.2  
No load to full load; nominal input  
Output voltage 95% of nominal  
115  
Short circuit current (typ.)  
115  
115  
115  
% Iout  
Output voltage <250mV  
MODULE INPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
34.9  
30.5  
Max  
Unit  
Notes  
Undervoltage turn-on  
Undervoltage turn-off  
35.7  
Vdc  
Vdc  
29.4  
75.7  
Overvoltage turn-off/on  
78.8  
82.5  
Vdc  
MODULE OUTPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
0.02  
0.002  
2
Max  
0.2  
Unit  
%
Notes  
Line regulation  
Low line to high line; full load  
-20 to 100°C  
Temperature regulation  
Power sharing accuracy  
Programming range  
0.005  
5
% / °C  
%
10 to 100% of full load  
10  
110  
%
Of nominal output voltage. For trim below 90% of  
nominal, a minimum load of 10% of maximum rated  
power may be required.  
Note: For important information relative to applications where the converters are subject to continuous dynamic loading,  
contact Vicor Applications Engineering at 800-927-9474 or your local Vicor office.  
Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715  
Page 2  
For the most current data and applications support, visit vicr.com.  
P R E L I M I N A R Y  
ELECTRICAL CHARACTERISTICS, continued  
MODULE CONTROL SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
PRIMARY SIDE (PC = Primary Control; PR = Parallel)  
PC bias voltage  
current limit  
PC module disable  
PC module enable delay  
PC module alarm  
1.5  
2.5  
2.1  
2.5  
4
3.0  
2.6  
7
mA  
Vdc  
PC voltage = 5.5V  
Must be able to sink 4 mA. See Fig. 1  
ms  
0.5  
6.1  
Vavg  
Volts  
mA  
UV, OV, module fault. See Figs. 2, 4  
PR load >30 ohms, < 30 pF  
PR emitter amplitude  
PR emitter current  
5.7  
150  
375  
2.4  
5.9  
PR receiver impedance  
PR receiver threshold  
PR drive capability  
500  
2.5  
625  
2.6  
12  
ohms  
Volts  
Modules  
25°C  
Minimum pulse width: 20ns  
Without PR buffer amplifier  
SECONDARY SIDE (SC = Secondary Control)  
SC bandgap voltage  
1.22  
990  
1.23  
1.24  
Vdc  
Referenced to –Sense  
SC resistance  
1000  
0.033  
0
1010  
ohms  
µF  
SC capacitance  
SC module alarm  
Vdc  
With open trim; referenced to –Sense. See Fig. 6  
MODULE GENERAL SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Remote sense (total drop)  
Isolation voltage (in to out)  
Isolation voltage (in to case)  
Isolation voltage (out to case)  
0.5  
Vdc  
Vdc  
Vdc  
Vdc  
0.25V per leg (senses must be closed)  
1500  
1500  
1500  
Isolation resistance (in to out)  
Weight  
10  
Megohms  
0.9 (26)  
Ounces (grams)  
S Case  
Agency Approvals  
UL, CSA, TÜV, BABT, CE, VDE  
UL1950, CSA950, EN60950, VDE0805, BS7002,  
IEC 60950. With a fuse in a series with the +Input  
TYPICAL PERFORMANCE 45°C, 400LFM, 100% Duty Cycle  
Case Configuration  
Max. Power @ 12Vout  
Max. Current @ 3.3Vout  
S
F1  
F2  
45W  
9A  
F3  
F4  
32W  
6.4A  
37W  
7.5A  
55W  
11A  
71W  
14A  
For complete thermal design support, and the complete list of package options, see our web site at vicr.com/powerstick.  
Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715  
Page 3  
For the most current data and applications support, visit vicr.com.  
P R E L I M I N A R Y  
CONTROL FUNCTIONS - PC PIN  
Module Enable/Disable  
Module Alarm  
The module may be disabled by pulling PC below 2.3V with  
respect to the –Input. This may be done with an open collector  
transistor, relay, or optocoupler. Multiple converters may be  
disabled with a single transistor or relay either directly or via  
“OR’ing” diodes. See Figure 1.  
The module contains “watchdog” circuitry which monitors  
input voltage, and internal operating parameters. In the event  
that any of these parameters are outside of their allowable  
operating range, the module will shut down and PC will go  
low. PC will periodically go high and the module will check to  
see if the fault has cleared. If the fault has not been cleared, PC  
will go low again and the cycle will restart. The SC pin will go  
low in the event of a fault and return to its normal state after  
the fault has been cleared. See Figures 2, 4.  
Primary Auxiliary Supply  
At 5.7V, PC can source up to 1.5mA. In the example shown  
in Figure 3, PC powers a Module Enabled LED.  
Input Undervoltage  
Auto  
+IN  
PC  
Restart  
Input Overvoltage  
Module Faults  
50  
SW1  
+IN  
+OUT  
2-20ms typ.  
f
(V )  
IN  
+S  
SC  
-S  
SW1, 2, & 3  
shown in  
PC  
PR  
SW2  
1K  
SW3  
PR  
"Fault" position  
Disable  
5.7 Vdc  
(0-3mA)  
1.23  
Vdc  
-IN  
-OUT  
-IN  
6K  
Disable = PC <2.3V  
Figure 1—Module enable/disable.  
Figure 2—PC/SC module alarm logic.  
Fault  
40µs typ.  
+IN  
PC  
5.7V  
PC  
4k  
PR  
"Module  
Enabled"  
-IN  
1.23V  
2-20ms typ.  
SC  
Figure 3—LED on-state indicator.  
Figure 4—PC/SC module alarm timing.  
Optocoupler  
+OUT  
+IN  
+S  
SC  
-S  
PC  
PR  
Alarm  
4k  
1.00V  
-OUT  
-IN  
Figure 5—Isolated on-state indicator.  
Figure 6—Secondary side on-state indicator.  
Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715  
Page 4  
For the most current data and applications support, visit vicr.com.  
P R E L I M I N A R Y  
CONTROL FUNCTIONS - SC PIN  
Output Voltage Programming  
The output voltage of the converter can be adjusted or  
programmed via fixed resistors, potentiometers or voltage  
DACs. See Figures 7 & 8.  
+OUT  
+S  
+OUT  
+S  
SC  
-S  
Error  
RD  
Trim Down  
Error  
Amp  
RU  
Trim Up  
SC  
Load  
Amp  
Load  
1kΩ  
-S  
1kΩ  
0.033  
µF  
0.033  
µF  
-OUT  
-OUT  
1.23V  
1.23V  
1,000 Vout  
1,000 (Vout-1.23) Vnom  
1.23 (Vout-Vnom)  
R
(ohms) =  
D
-
1,000  
R
(ohms) =  
U
Vnom - Vout  
Figure 7—Output voltage trim down circuit.  
Figure 8—Output voltage trim up circuit.  
Trim Down  
Trim Up  
1. This converter is not a constant power device – it has a  
1. As output voltage is increased, reduce output current maximum  
to insure that maximum rated power is not exceeded.  
constant current limit. Hence, available output power is  
reduced by the same percentage that output voltage is  
trimmed down. Do not exceed maximum rated output current.  
2. The trim up resistor must be connected to the +Sense pin.  
3. Do not trim the converter above maximum trim range  
(typically +10%) or the output over voltage  
protection circuitry may be activated.  
2. The trim down resistor must be connected to the –Sense pin.  
Trim values calculated automatically:  
Resistor trim calculators are available on  
Vicor’s web site, vicr.com, by selecting  
Calculators from the Toolbox.  
Resistor values can be calculated for fixed  
trim up, fixed trim down and for variable  
trim up or down by selecting the trim  
calculator for 2nd Generation DC-DC  
converters.  
In addition to trimming information, the  
web site also includes design tips,  
applications circuits, EMC suggestions,  
thermal design guidelines and PDF data  
sheets for all available Vicor products.  
Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715  
Page 5  
For the most current data and applications support, visit vicr.com.  
P R E L I M I N A R Y  
CONTROL FUNCTIONS - PR PIN  
Compatible interface architectures include the following:  
DC coupled single-wire interface. All PR pins are directly  
connected to one another. This interface supports current  
sharing but is not fault tolerant. Minus In pins must be tied to  
the same electric potential. See Figure 9.  
Parallel Operation  
The PR pin supports paralleling for increased power with N+1  
(N+M) redundancy and phased array capability (see Phased  
Array Control Chip at vicr.com). Modules of the same input  
voltage, output voltage, and power level will current share if  
all PR pins are suitably interfaced.  
AC coupled single-wire interface. All PR pins are connected  
to a single communication bus through .001µF (500V)  
capacitors. This interface supports current sharing and is fault  
tolerant except for the communication bus. See Figure 10.  
+IN  
+IN  
.001µF  
PowerStick  
1
PowerStick  
PC  
PR  
PC  
PR  
1
-IN  
-IN  
+IN  
+IN  
.001µF  
PowerStick 2  
(up to 12)  
PowerStick 2  
(up to 12)  
PC  
PR  
PC  
PR  
-IN  
-IN  
Ground plane  
Ground plane  
Figure 10—AC coupled single-wire interface.  
Figure 9—DC coupled single-wire interface.  
+OUT  
The +Out and Out power buses  
+S  
SC  
-S  
should be designed to minimize  
and balance parasitic impedance  
from each module output to the  
load.  
PowerStick  
1
-OUT  
+OUT  
+S  
The +Sense pins should be tied  
to the same point on the +Out  
power bus; the Sense pins  
should be tied to the same point  
on the Out power bus.  
+S  
SC  
-S  
+OUT  
+S  
SC  
-S  
Load  
PowerStick  
2
At the discretion of the power  
system designer, a subset of all  
modules within an array may be  
configured as slaves by shorting  
SC to S.  
-OUT  
-OUT  
+Sense from  
other modules  
in the array  
S  
+OUT  
+S  
SC  
-S  
PowerStick  
N+1  
ORing diodes may be inserted in  
series with the +Out pins of each  
module to provide module output  
fault tolerance.  
-OUT  
Figure 11—N+1 module array output connections.  
Figure 12—OR’ing diodes connections.  
Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715  
Page 6  
For the most current data and applications support, visit vicr.com.  
P R E L I M I N A R Y  
2.45  
MECHANICAL DRAWINGS  
62,34  
.09  
2.280  
57,92  
.003  
0,08  
.500  
12,7  
2,2  
.50  
12,69  
S Case  
.062  
.062  
1,57  
TYP.  
1,57  
TYP.  
.097  
2,46  
.097  
2,46  
2.26  
57,41  
Typical Case Configurations  
For comprehensive thermal management information, visit vicr.com/powerstick  
.500  
12,7  
.600  
15,2  
.725  
1.075  
27,31  
.875  
18,42  
22,23  
F2 Case  
S Case  
F1 Case  
F4 Case  
F3 Case  
2.280  
57,92  
PCB MOUNTING SPECIFICATIONS  
.031  
R
0,79 (5) PL.  
.310  
7,87  
.350  
8,89  
.515  
13,08  
PCB MOUNTING APERTURE  
(NON-COMPONENT SIDE SHOWN)  
.100 .003  
2,53 0,08  
.101  
2,57  
.152 .003  
3,85 0,08  
.092  
2,34  
.158 .003  
4,01 0,08  
.210 .003  
5,33 0,08  
.106 .003  
2,69 0,08  
ALL MARKINGS, THIS SURFACE  
5
-OUT  
4
-IN  
PR  
PC  
-S  
SC  
+S  
6
7
8
9
3
.003  
8,02 0,08  
.316  
.298 .003  
7,57 0,08  
2
+IN  
1
+OUT  
.133 .003  
.025 .003  
Converter Pins  
No. Function Label  
.025 .003  
.120 .003  
3,05 0,08  
(2) PL.  
3,38 0,08  
0,64 0,08  
(2) PL.  
0,64 0,08  
(2) PL.  
(3) PL.  
PAD DIMENSIONS  
1
2
+In  
+
PC  
.2055  
5,22  
.115  
2,92  
.000  
0,00  
Primary  
2.280  
57,91  
2.3475  
59,63  
Control  
.120  
R.031  
0,79  
.0675  
1,71  
.106  
2,70  
.000  
0,00  
3
4
5
6
7
Parallel  
In  
Out  
Sense  
Secondary SC  
Control  
PR  
3,05  
(5) PL.  
.097  
2,46  
POWER IN  
+ IN  
.115  
2,92  
+ OUT  
.049  
1,24  
S  
.052  
1,32  
.134  
3,40  
INPUT  
- IN  
OUTPUT  
- OUT  
.101  
2,57  
.104  
2,64  
.210  
5,33  
POWER OUT  
8
9
+Sense  
+Out  
+S  
+
.201  
5,11  
.115  
2,92  
.026  
0,67  
SOLDER PAD LAYOUT  
.3095  
7,86  
CONTROL PINS  
Shock and Vibration rating for standard mounting: 5grms vibration, 500g shock  
Vicor Corporation Tel: 800-735-6200 • 978-470-2900 • Fax: 978-475-6715  
Page 7  
For the most current data and applications support, visit vicr.com.  
Vicor’s comprehensive line of power solutions includes modular, high  
density DC-DC converters and accessory components, configurable power  
supplies, and custom power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is  
assumed by Vicor for its use. No license is granted by implication or otherwise under any patent or patent  
rights of Vicor. Vicor components are not designed to be used in applications, such as life support systems,  
wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and  
Conditions of Sale, which are available upon request.  
Specifications are subject to change without notice.  
The latest data is available on the Vicor web site at vicr.com.  
Component Solutions  
45  
for Your Power System  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
978-470-2900  
Fax: 978-475-6715  
Email  
Vicor Express: vicorexp@vicr.com  
Technical Support: apps@vicr.com  
P/N 23223 REV 2 7/01/10M  
For the most current data and applications support, visit vicr.com.  

相关型号:

PS48M3V3DTF3

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, 2.280 X 0.500 INCH, 0.350 INCH HEIGHT, MODULE-9
VICOR

PS49

Analog IC
ETC

PS490

Analog IC
ETC

PS4A-3.175T

CONN HORIZ TYPE FOR 3MM BUSBAR
HRS

PS4A-6.35T

CONN HORIZ TYPE FOR 6MM BUSBAR
HRS

PS4W

Monostable or bistable relays Single and double Coil magnet latching Type available
DBLECTRO

PS5

Monostable or bistable relays Single and double Coil magnet latching Type available
DBLECTRO

PS50-12S05

High Density DC-DC Modules
ETC

PS50-12S12

High Density DC-DC Modules
ETC

PS50-12S15

High Density DC-DC Modules
ETC

PS50-12S24

High Density DC-DC Modules
ETC

PS50-12S25

High Density DC-DC Modules
ETC