V24A6.5C400BF2 [VICOR]

DC-DC Converter Module;
V24A6.5C400BF2
型号: V24A6.5C400BF2
厂家: VICOR CORPORATION    VICOR CORPORATION
描述:

DC-DC Converter Module

文件: 总15页 (文件大小:512K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Maxi Family  
24V Input  
Actual size:  
4.6 x 2.2 x 0.5in  
117 x 56 x 12,7mm  
S
®
C
NRTL US  
C
US  
DC-DC Converter Module  
Features & Benefits  
Applications  
DC input range: 18 – 36V  
Isolated output  
Industrial and process control, distributed power, medical, ATE, communications, defense  
and aerospace.  
For details on proper operation please refer to the:  
Design Guide & Applications Manual for Maxi, Mini, Micro Family.  
Operation to 16V at 75% power  
after startup  
Input surge withstand: 50V for 100ms  
DC output: 3.3 – 48V  
Absolute Maximum Ratings  
Programmable output: 10 to 110%  
Regulation: 0.25% no load to full load  
Efficiency: Up to 88%  
Parameter  
Rating  
-0.5 to +53  
-0.5 to +7.0  
-0.5 to +7.0  
-0.5 to +1.5  
1.0  
Unit  
VDC  
VDC  
VDC  
VDC  
VDC  
Notes  
+In to –In voltage  
PC to –In voltage  
PR to –In voltage  
SC to -Out voltage  
-Sense to -Out voltage  
Maximum operating temp: 100°C,  
full load  
Power density: up to 99W per cubic inch  
Height above board: 0.43in. (10,9mm)  
Parallelable, with N+M fault tolerance  
Low noise ZCS/ZVS architecture  
See Module Output  
Specifications  
+Out to -Out, +Sense to -Out  
Isolation voltage  
in to out  
RoHS Compliant (with F or G pin option)  
3000  
1500  
VRMS  
VRMS  
Test voltage  
Test voltage  
Test voltage  
M-Grade  
Product Overview  
in to base  
out to base  
500  
VRMS  
These DC-DC converter modules use advanced  
power processing, control and packaging  
technologies to provide the performance,  
flexibility, reliability and cost effectiveness of a  
mature power component.  
Operating Temperature  
Storage Temperature  
-55 to +100  
-65 to +125  
500 (260)  
750 (390)  
5 (0.57)  
°C  
°C  
M-Grade  
°F (°C)  
°F (°C)  
in-lbs (N-m)  
<5 sec; wave solder  
<7 sec; hand solder  
6 each  
Pin soldering temperature  
Mounting torque  
High frequency ZCS/ZVS switching provides  
high power density with low noise and  
high efficiency.  
Part Numbering  
24A  
B
e.g. V24A12T400BL2  
Output Power  
POUT  
Product Grade Temperatures (°C)  
Pin Style  
Blank: Short  
L: Long  
S: Short ModuMate  
N: Long ModuMate  
F: Short RoHS  
G: Long RoHS  
K: Extra Long RoHS  
Finish  
Tin/Lead  
Tin/Lead  
Gold  
Gold  
Gold  
Baseplate  
Blank: Slotted  
2: Threaded  
Product Type  
Output Voltage  
3V3 = 3.3V  
5 = 5V  
6.5 = 6.5V  
8 = 8V  
12 = 12V  
15 = 15V  
24 = 24V  
28 = 28V  
36 = 36V  
48 = 48V  
VOUT  
Grade  
Operating  
Storage  
V = Standard  
E
C
T
H
M
=
=
=
=
=
-
-
-
-
-
10 to +100  
20 to +100  
40 to +100  
40 to +100  
55 to +100  
-
-
-
-
-
20 to +125  
40 to +125  
40 to +125  
55 to +125  
65 to +125  
3.3V  
5V  
6.5V  
8V  
12V  
15V  
24V  
28V  
36V  
48V  
200W, 264W  
300W, 400W  
400W  
300W  
300W, 400W, 500W  
300W, 400W  
300W, 400W, 500W  
300W, 400W, 500W  
300W, 400W  
S = Enhanced  
efficiency  
3: Through-hole  
(avail. 12  
Vout only)  
Gold  
Gold  
300W, 400W  
24V Maxi Family  
Page 1 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
Module Family Electrical Characteristics  
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.  
All temperatures refer to the operating temperature at the center of the baseplate.  
MODULE INPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
These modules will operate at up to 75% of rated power down  
to 16V after start up at >18V  
Operating input voltage  
18  
24  
36  
VDC  
IN  
<100ms  
IN  
Input surge withstand  
Undervoltage turn-on  
Undervoltage turn-off  
Overvoltage turn-off/on  
50  
VDC  
VDC  
VDC  
VDC  
17.5  
15.3  
37.8  
17.9  
14.8  
36.3  
39.6  
4.0  
Disabled input current  
mA  
PC pin low  
MODULE OUTPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
1%  
Unit  
VOUT nom  
%
Notes  
Output voltage setpoint  
Line regulation  
Nominal input; full load; 25°C  
Low line to high line; full load  
0.02  
0.002  
2
0.20  
0.005  
5
Temperature regulation  
Power sharing accuracy  
% / °C  
%
Over operating temperature range  
10 to 100% of full load  
Of nominal output voltage. For trimming below 90%  
of nominal, a minimum load of 10% of maximum  
rated power may be required.  
Programming range  
10  
110  
%
+Out to -Out, +Sense to -Out – Absolute Maximum Ratings  
3.3V  
5V  
-0.5 to 4.7  
-0.5 to 7.0  
-0.5 to 9.0  
-0.5 to 10.9  
-0.5 to 16.1  
-0.5 to 20.0  
-0.5 to 31.7  
-0.5 to 36.9  
-0.5 to 47.2  
-0.5 to 62.9  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
6.5V  
8V  
12V  
15V  
24V  
28V  
36V  
48V  
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,  
contact Vicor applications engineering at 800-927-9474.  
THERMAL RESISTANCE AND CAPACITY  
Parameter  
Min  
Typ  
0.08  
0.07  
4.9  
Max  
Unit  
°C/Watt  
°C/Watt  
°C/Watt  
°C/Watt  
Watt-sec/°C  
Baseplate to sink; flat, greased surface  
Baseplate to sink; thermal pad (P/N 20263)  
Baseplate to ambient  
Baseplate to ambient; 1000 LFM  
Thermal capacity  
1.1  
165  
24V Maxi Family  
Page 2 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
Module Family Electrical Characteristics (Cont.)  
MODULE CONTROL SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Primary Side (PC = Primary Control; PR = Parallel)  
PC bias voltage  
current limit  
5.50  
1.5  
5.75  
2.1  
6.00  
VDC  
mA  
PC current = 1.0mA  
PC voltage = 5.5V  
During normal operation  
3.0  
2.9  
7
PC module disable  
PC module enable delay  
PC module alarm  
2.3  
2.6  
4
VDC  
ms  
Switch must be able to sink 4mA. See Fig. 2  
0.5  
1.1  
6.1  
Vavg  
MΩ  
Volts  
mA  
Ω
UV, OV, OT, module fault. See Figs. 3 and 5  
See Fig. 3, converter off or fault mode  
PR load >30Ω, <30pF  
PC resistance  
0.9  
5.7  
150  
375  
2.4  
1.0  
5.9  
PR emitter amplitude  
PR emitter current  
PR receiver impedance  
PR receiver threshold  
PR drive capability  
500  
2.5  
625  
2.6  
12  
25°C  
Volts  
Minimum pulse width: 20ns  
Without PR buffer amplifier  
modules  
Secondary Side (SC = Secondary Control)  
SC bandgap voltage  
SC resistance  
1.21  
990  
1.23  
1000  
0.033  
1.25  
VDC  
Ω
Referenced to –Sense  
1010  
SC capacitance  
µF  
SC module alarm  
0
VDC  
With open trim; referenced to –Sense. See Fig. 7  
MODULE GENERAL SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Remote sense (total drop)  
0.5  
VDC  
0.25V per leg (sense leads must be connected to  
respective, output terminals)  
Isolation test voltage (in to out)*  
Isolation test voltage (in to base)*  
Isolation test voltage (out to base)*  
3000  
1500  
500  
VRMS  
VRMS  
VRMS  
Complies with reinforced insulation requirements  
Complies with basic insulation requirements  
Complies with operational insulation requirements  
Isolation resistance  
10  
MΩ  
in to out, in to baseplate, out to baseplate  
6.5  
7.3  
8.1  
ounces  
(grams)  
Weight (E, C, T grade)  
(184.3)  
(207.5)  
(230.7)  
7.4  
8.2  
9.0  
ounces  
(grams)  
Weight (H, M grade)  
(209.3)  
(232.5)  
(255.7)  
Temperature limiting  
Agency approvals  
100  
115  
°C  
See Figs. 3 and 5. Do not operate coverter >100C.  
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.  
With appropriate fuse in series with the +Input  
cURus, cTÜVus, CE  
* Isolation test voltage, 1 minute or less.  
Note: Specifications are subject to change without notice.  
24V Maxi Family  
Page 3 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS  
3.3VOUT, 264W (e.g. S24A3V3C264BL, V24A3V3C264BL)  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Efficiency  
S24A3V3C264BL (enhanced efficiency)  
V24A3V3C264BL (standard efficiency)  
Ripple and noise  
83.0  
80.0  
86.0  
81.4  
75  
%
Nominal input; full load; 25°C  
94  
4.46  
12  
mV  
Volts  
Watts  
%
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
4.14  
4.3  
8
0.02  
0.2  
80  
No load to full load; nominal input  
Load current  
0
Amps  
Amps  
Amps  
Current limit  
81.6  
56  
92  
92  
108  
108  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
3.3VOUT, 200W (e.g. S24A3V3C200BL, V24A3V3C200BL)  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Efficiency  
S24A3V3C200BL (enhanced efficiency)  
V24A3V3C200BL (standard efficiency)  
Ripple and noise  
82.0  
73.9  
86.0  
79.9  
43  
%
Nominal input; full load; 25°C  
54  
mV  
Volts  
Watts  
%
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
4.48  
4.65  
6.2  
4.82  
10  
0.02  
0.2  
No load to full load; nominal input  
Load current  
0
60.6  
81.9  
81.9  
Amps  
Amps  
Amps  
Current limit  
61.8  
42.4  
69.7  
69.7  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
5VOUT, 400W (e.g. S24A5C400BL, V24A5C400BL)  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Efficiency  
S24A5C400BL (enhanced efficiency)  
V24A5C400BL (standard efficiency)  
Ripple and noise  
84.0  
80.0  
86.5  
84.5  
152  
6.25  
6.8  
%
Nominal input; full load; 25°C  
190  
6.47  
10.1  
0.25  
80  
mV  
Volts  
Watts  
%
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
6.03  
0.02  
No load to full load; nominal input  
Load current  
0
Amps  
Amps  
Amps  
Current limit  
81.6  
56  
92  
92  
104  
104  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
5VOUT, 300W (e.g. S24A5C300BL, V24A5C300BL)  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Efficiency  
S24A5C300BL (enhanced efficiency)  
V24A5C300BL (standard efficiency)  
Ripple and noise  
82.5  
82.5  
84.4  
84.4  
120  
6.25  
7.2  
%
Nominal input; full load; 25°C  
150  
6.47  
8.8  
0.2  
60  
mV  
Volts  
Watts  
%
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
6.03  
0.02  
No load to full load; nominal input  
Load current  
0
Amps  
Amps  
Amps  
Current limit  
61.2  
42  
69  
69  
81  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
81  
24V Maxi Family  
Page 4 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)  
6.5VOUT, 400W (e.g. S24A6V5C400BL, V24A6V5C400BL)  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Efficiency  
S24A6V5C400BL (enhanced efficiency)  
V24A6V5C400BL (standard efficiency)  
Ripple and noise  
85.0  
85.0  
86.1  
86.1  
220  
7.98  
9.2  
%
Nominal input; full load; 25°C  
275  
8.26  
10.5  
0.2  
mV  
Volts  
Watts  
%
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
7.7  
0.02  
No load to full load; nominal input  
Output Current  
0
61.5  
83.1  
83.1  
Amps  
Amps  
Amps  
Current limit  
62.7  
43  
70.7  
70.7  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
8VOUT, 300W (e.g. S24A8C300BL, V24A8C300BL)  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Efficiency  
S24A8C300BL (enhanced efficiency)  
V24A8C300BL (standard efficiency)  
Ripple and noise  
85.6  
85.6  
86.5  
86.5  
215  
9.7  
%
Nominal input; full load; 25°C  
269  
10.1  
13.9  
0.2  
mV  
Volts  
Watts  
%
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
9.36  
8.7  
0.02  
No load to full load; nominal input  
Load current  
0
37.5  
50.7  
50.7  
Amps  
Amps  
Amps  
Current limit  
38.2  
26.2  
43.1  
43.1  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
12VOUT, 500W (e.g. S24A12C500B, V24A12C500BL)  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Efficiency  
S24A12C500B (enhanced efficiency)  
V24A12C500BL (standard efficiency)  
Ripple and noise  
86.7  
86.0  
88.2  
87.5  
272  
%
Nominal input; full load; 25°C  
340  
14.8  
12.0  
0.2  
mV  
Volts  
Watts  
%
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
13.8  
14.3  
10.8  
0.02  
No load to full load; nominal input  
Load current  
0
41.67  
56.3  
56.3  
Amps  
Amps  
Amps  
Current limit  
42.5  
29.2  
47.9  
47.9  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
12VOUT, 400W (e.g. S24A12C400BL, V24A12C400BL)  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Efficiency  
S24A12C400BL (enhanced efficiency)  
V24A12C400BL (standard efficiency)  
Ripple and noise  
86.0  
87.0  
89.5  
88.3  
250  
14.3  
6.8  
%
Nominal input; full load; 25°C  
320  
14.9  
10.2  
0.2  
mV  
Volts  
Watts  
%
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
13.7  
0.02  
No load to full load; nominal input  
Load current  
0
33.33  
43.5  
43.5  
Amps  
Amps  
Amps  
Current limit  
34  
38.4  
38.4  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
23.3  
24V Maxi Family  
Page 5 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)  
12VOUT, 300W (e.g. S24A12C300BL, V24A12C300BL)  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Efficiency  
S24A12C300BL (enhanced efficiency)  
V24A12C300BL (standard efficiency)  
Ripple and noise  
88.0  
87.0  
89.5  
88.2  
196  
14.3  
6.9  
%
Nominal input; full load; 25°C  
245  
14.9  
8.6  
mV  
Volts  
Watts  
%
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
13.7  
0.02  
0.2  
No load to full load; nominal input  
Load current  
0
25  
Amps  
Amps  
Amps  
Current limit  
25.5  
17.5  
28.8  
28.8  
33.8  
33.8  
Output voltage 95% of nominal  
Output voltage < 250mV  
Short circuit current  
15VOUT, 400W (e.g. V24A15C400BL)  
Parameter  
Min  
Typ  
89.0  
60  
Max  
Unit  
%
Notes  
Efficiency  
88.0  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
75  
18.5  
9.4  
mV  
17.1  
17.8  
6.3  
Volts  
Watts  
%
0.02  
0.2  
No load to full load; nominal input  
0
26.67  
34.8  
37.9  
Amps  
Amps  
Amps  
Current limit  
27.2  
18.6  
30.7  
30.7  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
15VOUT, 300W (e.g. V24A15C300BL)  
Parameter  
Min  
Typ  
86.2  
160  
17.8  
8.1  
Max  
Unit  
%
Notes  
Efficiency  
85.0  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
200  
18.5  
10  
mV  
17.1  
Volts  
Watts  
%
0.02  
0.2  
20  
No load to full load; nominal input  
0
Amps  
Amps  
Amps  
Current limit  
20.4  
14  
23  
23  
27  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
27  
24VOUT, 500W (e.g. V24A24C500BL)  
Parameter  
Min  
Typ  
88.3  
172  
Max  
Unit  
%
Notes  
Efficiency  
87.3  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
215  
29.1  
19.1  
0.2  
mV  
27.1  
28.1  
11.9  
0.02  
Volts  
Watts  
%
No load to full load; nominal input  
0
20.83  
28.1  
28.1  
Amps  
Amps  
Amps  
Current limit  
21.3  
14.6  
24.0  
24.0  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
24V Maxi Family  
Page 6 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)  
24VOUT, 400W (e.g. V24A24C400BL)  
Parameter  
Min  
Typ  
89.1  
80  
Max  
Unit  
%
Notes  
Efficiency  
88.0  
Nominal input; full load; 25°C  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
100  
29.1  
12  
mV  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
27.1  
28.1  
11  
Volts  
Watts  
%
0.02  
0.2  
No load to full load; nominal input  
0
16.67  
23.4  
23.4  
Amps  
Amps  
Amps  
Current limit  
17  
19.2  
19.2  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
2.25  
24VOUT, 300W (e.g. V24A24C300BL)  
Parameter  
Min  
Typ  
88.2  
85  
Max  
Unit  
%
Notes  
Efficiency  
86.8  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
107  
29.1  
10  
mV  
27.1  
28.1  
7.8  
Volts  
Watts  
%
0.02  
0.2  
No load to full load; nominal input  
0
12.5  
16.9  
16.9  
Amps  
Amps  
Amps  
Current limit  
12.7  
8.75  
14.4  
14.4  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
28VOUT, 500W (e.g. V24A28C500BL)  
Parameter  
Min  
Typ  
88.0  
172  
Max  
Unit  
%
Notes  
Efficiency  
86.0  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
215  
33.9  
14.8  
0.2  
mV  
31.5  
32.7  
13.5  
0.02  
Volts  
Watts  
%
No load to full load; nominal input  
0
17.9  
24.2  
24.2  
Amps  
Amps  
Amps  
Current limit  
18.3  
12.5  
20.6  
20.6  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
28VOUT, 400W (e.g. V24A28C400BL)  
Parameter  
Min  
Typ  
87.8  
172  
32.7  
6.3  
Max  
Unit  
%
Notes  
Efficiency  
86.0  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
215  
33.9  
9.5  
mV  
31.5  
Volts  
Watts  
%
0.02  
0.2  
No load to full load; nominal input  
0
14.29  
19.4  
19.4  
Amps  
Amps  
Amps  
Current limit  
14.5  
10  
16.4  
16.4  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
24V Maxi Family  
Page 7 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)  
28VOUT, 300W (e.g. V24A28C300BL)  
Parameter  
Min  
Typ  
88.0  
100  
32.7  
7.1  
Max  
Unit  
%
Notes  
Efficiency  
87.0  
Nominal input; full load; 25°C  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
125  
33.9  
9.3  
mV  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
31.5  
Volts  
Watts  
%
0.02  
0.2  
No load to full load; nominal input  
0
10.9  
3
10.71  
14.5  
14.5  
Amps  
Amps  
Amps  
Current limit  
12.3  
12.3  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
36VOUT, 400W (e.g. V24A36C400BL)  
Parameter  
Min  
Typ  
88.0  
120  
41.9  
10  
Max  
Unit  
%
Notes  
Efficiency  
86.0  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
150  
43.4  
13  
mV  
40.4  
Volts  
Watts  
%
0.02  
0.2  
No load to full load; nominal input  
0
11.11  
15  
Amps  
Amps  
Amps  
Current limit  
11.3  
7.77  
12.8  
12.8  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
15  
36VOUT, 300W (e.g. V24A36C300BL)  
Parameter  
Min  
Typ  
88.3  
80  
Max  
Unit  
%
Notes  
Efficiency  
87.0  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
100  
43.4  
12  
mV  
40.4  
41.9  
9.8  
Volts  
Watts  
%
0.02  
0.2  
No load to full load; nominal input  
0
8.33  
11.3  
11.3  
Amps  
Amps  
Amps  
Current limit  
8.49  
5.83  
9.58  
9.58  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
48VOUT, 400W (e.g. V24A48C400BL)  
Parameter  
Min  
Typ  
86.7  
160  
Max  
Unit  
%
Notes  
Efficiency  
84.7  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
200  
57.8  
12.7  
0.2  
mV  
53.8  
55.8  
11.8  
0.02  
Volts  
Watts  
%
No load to full load; nominal input  
0
8.33  
11.3  
11.3  
Amps  
Amps  
Amps  
Current limit  
8.49  
4.79  
9.58  
9.58  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
24V Maxi Family  
Page 8 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)  
48VOUT, 300W (e.g. V24A48C300BL)  
Parameter  
Min  
Typ  
87.1  
180  
55.7  
7.7  
Max  
Unit  
%
Notes  
Efficiency  
86.0  
Nominal input; full load; 25°C  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
225  
57.7  
10  
mV  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100ms off)  
No load  
53.7  
Volts  
Watts  
%
0.02  
0.2  
No load to full load; nominal input  
0
6.25  
8.44  
8.44  
Amps  
Amps  
Amps  
Current limit  
6.37  
4.37  
7.19  
7.19  
Output voltage 95% of nominal  
Output voltage <250mV  
Short circuit current  
24V Maxi Family  
Page 9 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
Basic Module Operation  
C2*  
4.7nF  
C4*  
4.7nF  
+IN  
PC  
PR  
+OUT  
+S  
F1*  
SC  
C1*  
0.2µF  
–S  
–IN  
–OUT  
C3*  
4.7nF  
C5*  
4.7nF  
For C1 – C5, keep leads and connections short.  
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Maxi, Mini, Micro Design Guide.  
Comprehensive Online Application Information  
The Design Guide and Applications Manual includes:  
Application circuits  
Design requirements  
EMC considerations  
Current sharing in power arrays  
Thermal performance information  
Recommended soldering methods  
Accessory modules – filtering, rectification, front-ends  
Mounting options  
...and more.  
CLICK HERE TO VIEW  
DESIGN GUIDE  
Also at vicorpower.com  
PowerBench online configurators  
Over 20 Application Notes  
Online calculators – thermal, trimming, hold-up  
PDF data sheets for ALL Vicor products  
24V Maxi Family  
Page 10 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
Primary Control - PC PIN  
Module Enable/Disable  
Module Alarm  
The module may be disabled by pulling PC below 2.3V with  
respect to the –Input. This may be done with an open collector  
transistor, relay, or optocoupler. Multiple converters may be  
disabled with a single transistor or relay either directly or via  
“OR’ing” diodes. See Figure 2.  
The module contains “watchdog” circuitry which monitors  
input voltage, operating temperature and internal operating  
parameters. In the event that any of these parameters are  
outside of their allowable operating range, the module will shut  
down and PC will go low. PC will periodically go high and the  
module will check to see if the fault (as an example,  
Primary Auxiliary Supply  
overtemperature) has cleared. If the fault has not been cleared,  
PC will go low again and the cycle will restart. The SC pin will  
go low in the event of a fault and return to its normal state after  
the fault has been cleared. See Figures 3 and 5.  
At 5.7V, PC can source up to 1.5mA. In the example shown in  
Figure 4, PC powers a module enabled LED.  
Input Undervoltage  
Input Overvoltage (See Note 1)  
+IN  
PC  
+OUT  
+IN  
PC  
Overtemperature  
Module Faults  
Auto  
Restart  
SW1  
+S  
SC  
–S  
2-20 ms typ.  
50 Ω  
f (V  
)
IN  
SW1, 2, & 3  
shown in  
"Fault" position  
SW2  
1 K  
6 K  
SW3  
1 M  
PR  
PR  
Disable  
5.7 Vdc  
(0-3 mA)  
–IN  
1.23  
Vdc  
– OUT  
–IN  
1
Not applicable for 300 Vdc input family  
Disable = PC <2.3 V  
Figure 2 — Module enable/disable  
Figure 3 — PC/SC module alarm logic  
+IN  
PC  
Fault  
PC  
40 μs typ.  
5.7 V  
4 kΩ  
"Module  
Enabled"  
PR  
1.23 V  
2–20 ms typ.  
SC  
–IN  
Figure 4 — LED on-state indicator  
Figure 5 — PC/SC module alarm timing  
+IN  
PC  
Optocoupler  
+OUT  
Comparator  
+S  
SC  
–S  
4 kΩ  
Alarm  
PR  
1.00V  
–IN  
–OUT  
Figure 6 — Isolated on-state indicator  
Figure 7 — Secondary side on-state indicator  
24V Maxi Family  
Page 11 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
Secondary Control - SC PIN  
Parallel Bus - PR PIN  
Output Voltage Programming  
Parallel Operation  
The output voltage of the converter can be adjusted or  
programmed via fixed resistors, potentiometers or voltage DACs.  
See Figure 8.  
The PR pin supports paralleling for increased power with N+1  
(N+M) redundancy. Modules of the same input voltage, output  
voltage, and power level will current share if all PR pins are  
suitably interfaced.  
Compatible interface architectures include the following:  
+OUT  
+S  
AC coupled single-wire interface. All PR pins are connected  
to a single communication bus through 0.001µF (500V)  
capacitors. This interface supports current sharing and is fault  
tolerant except for the communication bus. Up to three  
converters may be paralleled by this method. See Figure 9.  
Error Amplifier  
Ru  
Trim Up  
SC  
+
Transformer coupled interface. For paralleling four or more  
converters a transformer coupled interface is required.  
See Figure 10.  
Load  
1 kΩ  
Rd  
Trim Down  
0.033 uF  
1.23 V  
-S  
For details on parallel operation please refer to the  
Design Guide & Applications Manual for Maxi, Mini, Micro Family.  
100 Ω typ.  
–OUT  
4.7 nF  
1,000 Vout  
Vnom – Vout  
+
Rd (ohms) =  
+IN  
PC  
PR  
–IN  
0.2 µF  
Z1*  
Module 1  
Module 2  
0.001 µF  
1,000 (Vout –1.23) Vnom  
RU (ohms) =  
– 1,000  
1.23 (Vout – Vnom)  
Figure 8 — Output voltage trim down and trim up circuit  
4.7 nF  
4.7 nF  
0.2 µF  
Low inductance  
ground plane  
or bus  
Trim Down  
+IN  
PC  
PR  
–IN  
1. This converter is not a constant power device – it has a  
constant current limit. Hence, available output power is  
reduced by the same percentage that output voltage is  
trimmed down. Do not exceed maximum rated  
outputcurrent.  
0.001 µF  
Z1*  
4.7 nF  
Parallel  
Bus  
2.The trim down resistor must be connected between the SC  
and -S pins. Do not bypass the SC pin directly  
with a capacitor.  
Figure 9 — AC coupled single-wire interface  
* See Maxi, Mini, Micro Design Guide  
Trim Up  
1. The converter is rated for a maximum delivered power. To  
ensure that maximum rated power is not exceeded, reduce  
maximum output current by the same percentage increase in  
output voltage.  
4.7 nF  
+IN  
+
0.2 µF  
PC  
Module 1  
T1  
2.The trim up resistor must be connected between the SC  
and +S pins. Do not bypass the SC pin directly  
with a capacitor.  
Z1*  
PR  
–IN  
4.7 nF  
4.7 nF  
3. Do not trim the converter above maximum trim range  
(typically +10%) or the output over voltage protection  
circuitry may be activated.  
+IN  
PC  
PR  
–IN  
0.2 µF  
Z1*  
Module 2  
T2  
Trim resistor values calculated automatically:  
On-line calculators for trim resistor values are available  
on the vicor website at:  
asp.vicorpower.com/calculators/calculators.asp?calc=1  
Resistor values can be calculated for fixed trim up, fixed  
trim down and for variable trim up or down.  
4.7 nF  
Parallel  
Bus  
Figure 10 — Transformer-coupled interface  
24V Maxi Family  
Page 12 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
Parallel Bus Output  
The +Out and –Out power buses should be designed to  
+OUT  
minimize and balance parasitic impedance from each  
module output to the load.  
+S  
SC  
–S  
Module 1  
Module 2  
The +Sense pins must be tied together to form a  
+Sense bus. This must be Kelvin connected to +Out at a  
single point. The –Sense pins should be tied together to  
form a –Sense bus. This must be Kelvin connected to –Out  
at a single point.  
–OUT  
+S  
–S  
+OUT  
At the discretion of the power system designer, a subset  
of all modules within an array may be configured as slaves  
by connecting SC to –S.  
+S  
SC  
–S  
Load  
–OUT  
OR’ing diodes may be inserted in series with the +Out pins  
of each module to provide module output fault tolerance.  
The +Sense and -Sense leads should be routed in close  
proximity to each other on the printed circuit board. If wires  
are used to connect the converters on a PCB to an external  
load, the Sense leads should be twisted together to reduce  
noise pickup.  
+OUT  
+S  
SC  
Module N+1  
–S  
–OUT  
Figure 11 — N+1 module array output connections  
PIN STYLES*  
Designator  
Description  
Short  
Finish  
Notes  
(None)  
Tin/Lead  
Tin/Lead  
Gold  
Requires in-board, mounting  
L
S
Long  
On-board mounting for 0.065” boards  
Short ModuMate  
Long ModuMate  
Short RoHS  
Long RoHS  
SurfMate or in-board socket mounting  
N
F
Gold  
On-board socket mounting  
Gold  
Select for RoHS compliant in-board solder, socket, or SurfMate mounting  
Select for RoHS compliant on-board solder or socket mounting  
G
K
Gold  
Extra Long RoHS  
Gold  
Select for RoHS compliance on-board mounting for thicker PCBs  
(not intended for socket or Surfmate mounting)  
* Pin style designator follows the “B” after the output power and precedes the baseplate designator.  
Ex. V48A12T500BN2 — Long ModuMate Pins  
24V Maxi Family  
Page 13 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
Mechanical Drawings  
Converter Pins  
No. Function Label  
1
+In  
+
Primary  
Control  
2
PC  
3
4
5
6
Parallel  
–In  
PR  
–Out  
–Sense  
–S  
Secondary  
Control  
7
SC  
8
9
+Sense  
+Out  
+S  
+
NOTES:  
1. MATERIAL:  
BASE: 6000 SERIES ALUMINUM  
DIMENSION L  
PINS: RoHS PINS GOLD PLATE 30 MICRO INCH MIN; NON-RoHS  
PINS: TIN/LEAD 90/10 BRIGHT  
PIN SHORT – .55±.ꢀ05 ꢁ01.ꢀ±.±ꢂ3  
PIN LONG–– .6±±.ꢀ05 ꢁ06.ꢀ±.±ꢂ3  
PIN EXTRA LONG–––- .70±.ꢀ05 ꢁ0ꢂ.ꢀ±.±ꢂ3  
2. DIMENSIONS AND VALUES IN BRACKETS ARE METRIC  
3. MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING  
BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD  
OF THE APPLICATION RANGES FROM DIRECT CONTACT (ZERO), TO THE  
MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACK-UP  
AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION  
Figure 12 — Module outline  
ONBOARD  
SOLDER  
MOUNT  
INBOARD  
SOLDER  
MOUNT  
ALL MARKINGS  
THIS SURFACE  
LONG PIN STYLE  
SHORT PIN STYLE  
0.062 0.010  
PCB THICKNESS  
0.094 0.003  
2,39 0,08  
0.094 0.003  
2,39 0,08  
(7X)  
(2X)  
1,57 0,25  
PLATED  
THRU HOLE  
DIA  
0.194 0.003  
4,93 0,08  
0.194 0.003  
4,93 0,08  
1.790**  
45,47  
0.06  
R
(4X)  
0.178  
4,52  
1,5  
1
2
3
4
ALUMINUM  
BASEPLATE  
4.200*  
106,68  
3.844**  
97,64  
PINS STYLES  
SOLDER:TIN/LEAD PLATED  
MODUMATE: GOLD PLATED COPPER  
RoHS: GOLD PLATED COPPER  
For Soldering Methods and Procedures  
Please refer to:  
9
8
7
6
5
THE MAXI, MINI, MICRO Design Guide.  
Unless otherwise specified,  
dimensions are in inches  
mm  
0.400*  
10,16  
0.45  
11,5  
0.53  
13,5  
0.700*  
17,78  
1.000*  
25,40  
1.400*  
35,56  
Decimals  
Tol.  
Angles  
0.003  
0,08  
* DENOTES TOL =  
0.XX  
±0.01  
±0.25  
**PCB WINDOW  
±1°  
0.195  
4,95  
0.XXX  
±0.005  
±0.127  
Figure 13 — PCB mounting specifications  
24V Maxi Family  
Page 14 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  
24V Input  
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and ac-  
cessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power  
systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no  
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make  
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and  
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are  
used to the extent Vicor deems necessary to support Vicors product warranty. Except where mandated by government requirements, testing of all  
parameters of each product is not necessarily performed.  
Specifications are subject to change without notice.  
Vicor’s Standard Terms and Conditions  
All sales are subject to Vicors Standard Terms and Conditions of Sale, which are available on Vicors webpage or upon request.  
Product Warranty  
In Vicors standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Ex-  
press Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is  
not transferable.  
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS  
ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH  
RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR  
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.  
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable  
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes  
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and  
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operat-  
ing safeguards.  
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact  
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be  
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the  
product was defective within the terms of this warranty.  
Life Support Policy  
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS  
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support  
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform  
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the  
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the  
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products  
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the  
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is  
granted by this document. Interested parties should contact Vicors Intellectual Property Department.  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
Fax: 978-475-6715  
email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
24V Maxi Family  
Page 15 of 15  
Rev 6.6  
01/2016  
vicorpower.com  
800 927.9474  

相关型号:

V24A6.5C400BF3

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BG

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BG2

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BG3

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BK

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BK2

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BK3

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BL

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BL2

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BL3

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BN

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

V24A6.5C400BN2

DC-DC Converter Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR