V24B12C150BS 概述
CONVERTER MOD DC/DC 12V 150W
V24B12C150BS 数据手册
通过下载V24B12C150BS数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Mini Family
24V Input
Actual size:
2.28 x 2.2 x 0.5in
[57,9 x 55,9 x 12,7mm]
S
®
C
NRTL US
DC-DC Converter Module
Features & Benefits
Applications
• DC input range: 18 – 36V
• Isolated output
Industrial and process control, distributed power, medical, ATE, communications,
defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
• Operation to 16V at 75% power
after start up
• Input surge withstand: 50V for 100ms
• DC output: 3.3 – 48V
Absolute Maximum Ratings
• Programmable output: 10 – 110%
• Regulation: 0.5% no load to full load
• Efficiency: Up to 89%
Parameter
Rating
–0.5 to +53
–0.5 to +7.0
–0.5 to +7.0
–0.5 to +1.5
1.0
Unit
VDC
VDC
VDC
VDC
VDC
Notes
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to –OUT voltage
–Sense to –OUT voltage
• Maximum operating temp: 100°C,
full load
• Power density: up to 80W per cubic inch
• Height above board: 0.43in [10,9mm]
• Parallelable, with N+M fault tolerance
• Low-noise ZCS/ZVS architecture
Isolation voltage
IN to OUT
3000
1500
VRMS
VRMS
VRMS
°C
Test voltage
Test voltage
Test voltage
M-Grade
IN to base
• RoHS Compliant (with F or G pin option)
OUT to base
500
Operating Temperature
Storage Temperature
–55 to +100
–65 to +125
500 [260]
750 [390]
5 [0.57]
Product Overview
°C
M-Grade
°F [°C]
°F [°C]
<5sec; wave solder
<7sec; hand solder
6 each
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
Pin soldering temperature
Mounting torque
.
.
in lbs [N m]
High-frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
24B
B
e.g. V24B12T200BL2
Output Power
POUT
Product Grade Temperatures (°C)
Pin Style
Blank: Short
L: Long
Finish
Tin/Lead
Baseplate
Blank: Slotted
2: Threaded
Output Voltage
3V3 = 3.3V
5 = 5V
Product Type
VOUT
Grade
Operating
Storage
V = Standard
S = Enhanced
efficiency
3.3V 100W, 150W
5V 150W, 200W
6.5V 200W
8V 200W
E
C
=
=
=
=
=
–10 to +100 –20 to +125
–20 to +100 –40 to +125
–40 to +100 –40 to +125
–40 to +100 –55 to +125
–55 to +100 –65 to +125
Tin/Lead
Gold
6.5 = 6.5V
8 = 8V
3: Through-hole
S: Short ModuMate
N: Long ModuMate
F: Short RoHS
T
Gold
(avail. ≤12
VOUT only)
12 = 12V
15 = 15V
24 = 24V
28 = 28V
36 = 36V
48 = 48V
H
M
Gold
12V 150W, 200W, 250W
15V 150W, 200W
G: Long RoHS
Gold
K: Extra Long RoHS
Gold
24V 150W, 200W, 250W
28V 150W, 200W, 250W
36V 150W, 200W
48V 150W, 200W, 250W
Note: Product images may not highlight current product markings.
24V Mini Family
Page 1 of 15
Rev 5.6
02/2021
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
Module Input Specifications
Parameter
Min
Typ
Max
36
Unit
VDC
VDC
VDC
VDC
VDC
VDC
Notes
Operating input voltage
Input surge withstand
Undervoltage turn–on
Undervoltage turn–off
Overvoltage turn–off/on
Disabled input current
18
24
50
<100ms
17.5
15.3
37.8
17.9
14.8
36.3
39.6
4.0
PC pin low
Module Output Specifications
Parameter
Min
Typ
Max
1
Unit
%
Notes
Output voltage set point
Line regulation
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 – 100% of full load
0.02
0.002
2
0.20
0.005
5
%
Temperature regulation
Power sharing accuracy
%/°C
%
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Programming range
10
110
%
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 9.1
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.1
–0.5 to 62.9
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 10.
Thermal Resistance and Capacity
Parameter
Min
Typ
0.16
0.14
8.0
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
1.9
83
24V Mini Family
Page 2 of 15
Rev 5.6
02/2021
24V Input
Module Family Electrical Characteristics (Cont.)
Module Control Specifications
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
5.50
1.5
5.75
2.1
6.00
3.0
VDC
mA
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
PC module disable
PC module enable delay
PC module alarm
2.3
2.6
4
2.9
7
VDC
ms
Switch must be able to sink ≥4mA. See Figure 2
0.5
1.1
6.1
VAVG
MΩ
UV, OV, OT, module fault. See Figures 3 and 5
See Figure 3, converter off or fault mode
PR load >30Ω, <30pF
PC resistance
0.9
5.7
150
375
2.4
1.0
5.9
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Volts
mA
500
2.5
625
2.6
12
Ω
25°C
Volts
modules
Minimum pulse width: 20ns
Without PR buffer amplifier
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
1.21
1.23
1000
0.033
1.25
VDC
Ω
Referenced to –Sense
990
1010
SC capacitance
µF
SC module alarm
0
VDC
With open trim; referenced to –Sense. See Figure 7
Module General Specifications
Parameter
Min
Typ
Max
Unit
Notes
Remote sense (total drop)
0.5
VDC
0.25V per leg (sense leads must be connected to
respective, output terminals)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
3000
1500
500
VRMS
VRMS
VRMS
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
Isolation resistance
10
MΩ
IN to OUT, IN to baseplate, OUT to baseplate
3.1
[89.3]
3.5
[100.3]
3.9
[111.3]
ounces
[grams]
Weight (E, C, T grade)
3.5
[99.6]
3.9
[110.6]
4.3
[121.6]
ounces
[grams]
Weight (H, M grade)
Temperature limiting
Agency approvals
100
115
°C
See Figures 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
cURus, cTÜVus, CE
* Isolation test voltage, 1 minute or less.
Note: Specifications are subject to change without notice.
24V Mini Family
Page 3 of 15
Rev 5.6
02/2021
24V Input
Module-Specific Operating Specifications
3.3VOUT, 150W (e.g. S24B3V3C150BL, V24B3V3C150BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B3V3C150BL (enhanced efficiency)
V24B3V3C150BL (standard efficiency)
Ripple and noise
84.0
80.0
86.5
81.4
160
4.3
%
Nominal input; 75% load; 25°C
200
4.46
6
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
4.14
5
0.02
0.2
No load to full load; nominal input
Load current
0
45.45
61.5
61.5
Amps
Amps
Amps
Current limit
46.4
31.8
52.3
52.3
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
3.3VOUT, 100W (e.g. S24B3V3C100BL, V24B3V3C100BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B3V3C100BL (enhanced efficiency)
V24B3V3C100BL (standard efficiency)
Ripple and noise
83.5
80.4
85.1
81.4
71
%
Nominal input; 75% load; 25°C
89
4.46
3
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
4.14
4.3
2.5
0.02
0.2
30.3
41
No load to full load; nominal input
Load current
0
Amps
Amps
Amps
Current limit
30.9
21.2
34.8
34.8
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
41
5VOUT, 200W (e.g. S24B5C200BL, V24B5C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B5C200BL (enhanced efficiency)
V24B5C200BL (standard efficiency)
Ripple and noise
85.9
80.5
87.0
84.9
95
%
Nominal input; 75% load; 25°C
119
6.53
5.5
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
6.07
6.3
5.1
0.02
0.45
40
No load to full load; nominal input
Load current
0
Amps
Amps
Amps
Current limit
40.8
28
52
52
54.5
62
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
5VOUT, 150W (e.g. S24B5C150BL, V24B5C150BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B5C150BL (enhanced efficiency)
V24B5C150BL (standard efficiency)
Ripple and noise
86.0
83.5
87.2
84.8
50
%
Nominal input; 75% load; 25°C
63
6.47
4.5
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
6.03
6.25
3.7
0.02
0.2
No load to full load; nominal input
Load current
0
30.6
5
30
Amps
Amps
Amps
Current limit
34.5
34.5
40.5
40.5
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
24V Mini Family
Page 4 of 15
Rev 5.6
02/2021
24V Input
Module-Specific Operating Specifications (Cont.)
6.5VOUT, 200W (e.g. S24B6V5C200BL, V24B6V5C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B6V5C200BL (enhanced efficiency)
V24B6V5C200BL (standard efficiency)
Ripple and noise
84.5
83.2
87.5
84.6
182
8.0
%
Nominal input; 75% load; 25°C
230
8.3
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
7.7
5.3
6.2
0.02
0.2
No load to full load; nominal input
Load current
0
30.8
41.5
41.5
Amps
Amps
Amps
Current limit
31.4
21.5
35.4
35.4
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
8VOUT, 200W (e.g. S24B8C200BL, V24B8C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B8C200BL (enhanced efficiency)
V24B8C200BL (standard efficiency)
Ripple and noise
87.0
85.0
89.0
86.4
310
9.7
%
Nominal input; 75% load; 25°C
390
10.1
6
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
9.36
5
0.02
0.2
No load to full load; nominal input
Load current
0
25
Amps
Amps
Amps
Current limit
25.5
17.5
28.8
28.8
33.8
33.8
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
12VOUT, 250W (e.g. S24B12C250BL, V24B12C250BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B12C250BL (enhanced efficiency)
V24B12C250BL (standard efficiency)
Ripple and noise
87.0
86.0
89.0
87.4
172
14.3
6.5
%
Nominal input; 75% load; 25°C
215
14.8
7.6
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
13.8
0.02
0.2
No load to full load; nominal input
Load current
0
20.8
28.1
28.1
Amps
Amps
Amps
Current limit
21.3
14.6
24.0
24.0
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
12VOUT, 200W (e.g. S24B12C200BL, V24B12C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B12C200BL (enhanced efficiency)
V24B12C200BL (standard efficiency)
Ripple and noise
87.0
87.0
90.0
88.0
360
14.4
4.6
%
Nominal input; 75% load; 25°C
450
15
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
13.8
7.4
0.02
0.2
No load to full load; nominal input
Load current
0
16.67
22.6
22.6
Amps
Amps
Amps
Current limit
17
19.2
19.2
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
11.6
24V Mini Family
Page 5 of 15
Rev 5.6
02/2021
24V Input
Module-Specific Operating Specifications (Cont.)
12VOUT, 150W (e.g. S24B12C150BL, V24B12C150BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B12C150BL (enhanced efficiency)
V24B12C150BL (standard efficiency)
Ripple and noise
87.5
87.0
90.0
88.6
200
14.3
4.5
%
Nominal input; 75% load; 25°C
250
14.9
5.4
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
13.7
0.02
0.2
No load to full load; nominal input
Load current
0
12.5
16.9
16.9
Amps
Amps
Amps
Current limit
12.7
8.75
14.4
14.4
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
15VOUT, 200W (e.g. V24B15C200BL)
Parameter
Min
Typ
88.9
250
17.8
3.4
Max
Unit
%
Notes
Efficiency
88.0
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
313
18.5
3.8
mV
17.1
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
13.33
17.3
17.3
Amps
Amps
Amps
Current limit
13.5
13.5
15.9
16.1
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
15VOUT, 150W (e.g. V24B15C150BL)
Parameter
Min
Typ
88.9
200
17.8
4.4
Max
Unit
%
Notes
Efficiency
88.0
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
250
18.5
5.4
mV
17.1
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
10.2
7
10
Amps
Amps
Amps
Current limit
11.5
11.5
13.5
13.5
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
24VOUT, 250W (e.g. V24B24C250BL)
Parameter
Min
Typ
87.0
300
28.1
7.7
Max
Unit
%
Notes
Efficiency
86.0
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
360
29.1
9.0
mV
27.1
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
10.4
14.1
14.1
Amps
Amps
Amps
Current limit
10.6
7.3
12.0
12.0
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
24V Mini Family
Page 6 of 15
Rev 5.6
02/2021
24V Input
Module-Specific Operating Specifications (Cont.)
24VOUT, 200W (e.g. V24B24C200BL)
Parameter
Min
Typ
87.0
260
28.5
5.1
Max
Unit
%
Notes
Efficiency
85.4
Nominal input; 75% load; 25°C
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
325
29.5
6.2
mV
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
27.5
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
8.33
11.5
11.5
Amps
Amps
Amps
Current limit
8.46
5.81
9.8
9.8
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
24VOUT, 150W (e.g. V24B24C150BL)
Parameter
Min
Typ
87.7
200
28.1
4.7
Max
Unit
%
Notes
Efficiency
86.5
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
250
29.1
5.1
mV
27.1
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
6.37
3
6.25
8.44
8.44
Amps
Amps
Amps
Current limit
7.19
7.19
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
28VOUT, 250W (e.g. V24B28C250BL)
Parameter
Min
Typ
88.7
133
32.7
9.6
Max
Unit
%
Notes
Efficiency
87.2
Nominal input; 75% load; 25°C
P-P Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
166
33.8
10.5
0.2
mV
31.5
Volts
Watts
%
0.02
No load to full load; nominal input
0
8.9
Amps
Amps
Amps
Current limit
9.1
6.3
10.3
10.3
12.1
12.1
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
28VOUT, 200W (e.g. V24B28C200BL)
Parameter
Min
Typ
87.0
180
32.8
4.5
Max
Unit
%
Notes
Efficiency
85.0
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
225
34
mV
31.6
Volts
Watts
%
5.5
0.02
0.2
No load to full load; nominal input
0
7.29
5
7.14
9.66
9.66
Amps
Amps
Amps
Current limit
8.22
8.22
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
24V Mini Family
Page 7 of 15
Rev 5.6
02/2021
24V Input
Module-Specific Operating Specifications (Cont.)
28VOUT, 150W (e.g. V24B28C150BL)
Parameter
Min
Typ
87.8
200
32.7
4.3
Max
Unit
%
Notes
Efficiency
86.5
Nominal input; 75% load; 25°C
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
250
33.9
5.2
mV
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
31.5
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
5.36
7.24
7.24
Amps
Amps
Amps
Current limit
5.46
3.75
6.16
6.16
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
36VOUT, 200W (e.g. V24B36C200BL)
Parameter
Min
Typ
88.0
200
41.9
4.5
Max
Unit
%
Notes
Efficiency
87.0
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
250
43.4
5.3
mV
40.4
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
5.55
7.51
7.51
Amps
Amps
Amps
Current limit
5.67
3.89
6.39
6.39
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
36VOUT, 150W (e.g. V24B36C150BL)
Parameter
Min
Typ
88.0
200
41.9
4.2
Max
Unit
%
Notes
Efficiency
86.7
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
250
43.4
5
mV
40.4
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
4.17
5.63
5.63
Amps
Amps
Amps
Current limit
4.25
2.91
4.8
4.8
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
48VOUT, 250W (e.g. V24B48C250BL)
Parameter
Min
Typ
89.1
182.0
55.7
7.4
Max
Unit
%
Notes
Efficiency
87.6
Nominal input; 75% load; 25°C
P-P Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
228.0
57.6
8.5
mV
53.8
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
5.2
Amps
Amps
Amps
Current limit
5.3
3.6
6.0
6.0
7.0
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
7.0
24V Mini Family
Page 8 of 15
Rev 5.6
02/2021
24V Input
Module-Specific Operating Specifications (Cont.)
48VOUT, 200W (e.g. V24B48C200BL)
Parameter
Min
Typ
87.5
225
55.8
5.4
Max
Unit
%
Notes
Efficiency
86.0
Nominal input; 75% load; 25°C
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
282
57.8
5.8
mV
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
53.8
Volts
Watts
%
0.02
0.5
No load to full load; nominal input
0
4.17
5.63
5.63
Amps
Amps
Amps
Current limit
4.25
2.91
4.8
4.8
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
48VOUT, 150W (e.g. V24B48C150BL)
Parameter
Min
Typ
88.9
125
55.7
3.7
Max
Unit
%
Notes
Efficiency
87.9
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
157
57.7
4.2
mV
53.7
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
3.13
4.23
4.33
Amps
Amps
Amps
Current limit
3.19
2.19
3.6
3.6
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
24V Mini Family
Page 9 of 15
Rev 5.6
02/2021
24V Input
Basic Module Operation
C2*
4.7nF
C4*
4.7nF
+IN
PC
PR
+OUT
+S
F1*
SC
C1*
0.2µF
–S
–IN
–OUT
C3*
4.7nF
C5*
4.7nF
For C1 – C5, keep leads and connections short.
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Maxi, Mini, Micro Design Guide.
Output Connections and Considerations
leads must be protected for conditions such as lead reversal,
noise pickup, open circuit or excessive output lead resistance
between the sense point and the converters output terminals.
For applications that may draw more than the rated current, a
fast-acting electronic circuit breaker must be utilized to protect
the converter. Under no circumstance should the rated current be
exceeded. Utilizing or testing of current limit or short-circuit current
will damage the converter. Ensure that the total output capacitance
connected to the converter does not exceed the limits on Page 16,
“Maximum Output Capacitance”, of the design guide.
The permissible load current must never be exceeded during
normal, abnormal or test conditions. Converters subject to dynamic
loading exceeding 25% of rated current must be reviewed by
Vicor Applications Engineering to ensure that the converter will
operate properly.
Under dynamic-load, light-load or no-load conditions, the converter
may emit audible noise. Converters that utilize remote sense may
require compensation circuitry to offset the phase lag caused by
the external output leads and load impedance. Remote-Sense
The Design Guide and Applications Manual includes:
• Application circuits
Comprehensive Online Application Information
• Design requirements
• EMC considerations
• Current sharing in power arrays
• Thermal performance information
• Recommended soldering methods
• Accessory modules – filtering, rectification, front-ends
• Mounting options
• ...and more.
CLICK HERE TO VIEW
DESIGN GUIDE
Also at vicorpower.com
• PowerBench online configurators
• Over 20 Application Notes
• Online calculators – thermal, trimming, hold-up
• PDF data sheets for ALL Vicor products
24V Mini Family
Page 10 of 15
Rev 5.6
02/2021
24V Input
Primary Control – PC Pin
Module Enable/Disable
Module Alarm
The module may be disabled by pulling PC to 0V (2.3V max) with
respect to the –Input. This may be done with an open collector
transistor, relay or optocoupler. Converters may be disabled with a
single transistor or relay either directly or via “OR’ing” diodes for
two or more converters. See Figure 2.
The module contains “watchdog” circuitry which monitors input
voltage, operating temperature and internal operating parameters.
In the event that any of these parameters are outside of their
allowable operating range, the module will shut down and PC will
go low. PC will periodically go high and the module will check to
see if the fault (as an example, Input Undervoltage) has cleared.
If the fault has not been cleared, PC will go low again and the
cycle will restart. The SC pin will go low in the event of a fault
and return to its normal state after the fault has been cleared. See
Figures 3 and 5.
Primary Auxiliary Supply
During normal operation only, the PC Pin can source 5.7V
@ 1.5mA. In the example shown in Figure 4, PC powers a
module enabled LED.
Input Undervoltage
Input Overvoltage
+IN
PC
+OUT
+IN
PC
+OUT
Overtemperature
Module Faults
Auto
Restart
SW1
+S
SC
–S
+S
SC
–S
2 – 20ms typ.
50Ω
f (VIN
)
SW1, 2, & 3
shown in
1kΩ
6kΩ
SW2
SW3
1MΩ
PR
Disable
PR
–IN
"Fault" position
5.7VDC
–IN
(0 – 3mA)
1.23
VDC
–OUT
–OUT
Disable = PC <2.3V
Figure 2 — Module enable/disable
Figure 3 — PC/SC module alarm logic
+IN
+OUT
Fault
PC
400µs typ.
5.7V
PC
+S
SC
–S
4kΩ
"Module
PR
Enabled"
1.23V
2 – 20ms typ.
–IN
SC
–OUT
Figure 4 — LED on-state indicator
Figure 5 — PC/SC module alarm timing
Optocoupler
+IN
+IN
+OUT
+OUT
PC
PC
+S
SC
–S
+S
SC
–S
4kΩ
Alarm
PR
PR
1.00V
–IN
–IN
–OUT
–OUT
Figure 6 — Isolated on-state indicator
Figure 7 — Secondary-side on-state indicator
24V Mini Family
Page 11 of 15
Rev 5.6
02/2021
24V Input
Compatible interface architectures include the following:
Secondary Control – SC Pin
AC-coupled single-wire interface. All PR pins are connected to a
single communication bus through 0.001µF (500V) capacitors. This
interface supports current sharing and is fault tolerant except for
the communication bus. Up to three converters may be paralleled
by this method. See Figure 9.
Output Voltage Programming
The output voltage of the converter can be adjusted or
programmed via fixed resistors, potentiometers or voltage
DACs. See Figure 8.
Transformer-coupled interface. For paralleling four or more
converters a transformer coupled interface is required, and under
certain conditions a PR buffer circuit.
+OUT
+S
For details on parallel operation please refer to the
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Error Amplifier
Ru
Trim Up
–
SC
+
Load
1kΩ
Rd
0.033µF
-S
Trim Down
1.23V
4.7nF
+
–
+IN
PC
PR
–IN
0.2µF
100Ω typ.
–OUT
0.001µF
Module 1
Module 2
R1*
V
1,000
OUT
Rd (Ω)
=
=
4.7nF
4.7nF
Low inductance
ground plane
or bus
VNOM – VOUT
VOUT
VNOM
)
1,000 (
–1.23)
RU (Ω)
– 1,000
1.23 (VOUT – VNOM
+IN
PC
PR
–IN
0.2µF
Figure 8 — Output voltage trim-down and trim-up circuit
0.001µF
R1*
Trim Down
4.7nF
Parallel
Bus
1. This converter is not a constant-power device – it has a
constant current limit. Hence, available output power is
reduced by the same percentage that output voltage is
trimmed down. Do not exceed maximum rated output current.
Figure 9 — AC-coupled single-wire interface
* See Maxi, Mini, Micro Design Guide
2. The trim-down resistor must be connected between the SC
and –S pins. Do not bypass the SC pin directly with a capacitor.
4.7nF
+IN
+
–
Trim Up
0.2µF
R1*
PC
Module 1
T1
1. The converter is rated for a maximum delivered power. To
ensure that maximum rated power is not exceeded, reduce
maximum output current by the same percentage increase in
output voltage.
PR
–IN
4.7nF
4.7nF
2. The trim-up resistor must be connected between the SC and
+IN
PC
PR
–IN
+S pins. Do not bypass the SC pin directly with a capacitor.
0.2µF
R1*
Module 2
T2
3. Do not trim the converter above maximum trim range (typically
+10%) or the output over voltage protection circuitry may
be activated.
4.7nF
Parallel
Bus
Trim resistor values calculated automatically:
Figure 10 — Transformer-coupled interface
On-line calculators for trim resistor values are available on
the vicor website at:
asp.vicorpower.com/calculators/calculators.asp?calc=1
Resistor values can be calculated for fixed trim up, fixed
trim down and for variable trim up or down.
Number of Converters in Parallel *R1 value Ω
2
75
50
33
3
Parallel Bus – PR Pin
4
5 or more
refer to application note:
Designing High-Power Arrays
using Maxi, Mini, Micro
Family DC-DC Converters
Parallel Operation
The PR pin supports paralleling for increased power with N+1
(N+M) redundancy. Modules of the same input voltage, output
voltage, and power level will current share if all PR pins are
suitably interfaced.
24V Mini Family
Page 12 of 15
Rev 5.6
02/2021
24V Input
Parallel Bus Output
• The +OUT and –OUT power buses should be designed to
+OUT
minimize and balance parasitic impedance from each
module output to the load.
+S
SC
–S
Module 1
Module 2
• The +Sense pins must be tied together to form a
+Sense bus. This must be Kelvin connected to +OUT at a
single point. The –Sense pins should be tied together to
form a –Sense bus. This must be Kelvin connected to –OUT
at a single point.
–OUT
+S
–S
+OUT
+S
SC
–S
• At the discretion of the power system designer, a subset
of all modules within an array may be configured as
children by connecting SC to –S.
Load
–OUT
• OR’ing diodes may be inserted in series with the +OUT pins
of each module to provide module output fault tolerance.
• The +Sense and –Sense leads should be routed in close
proximity to each other on the printed circuit board. If wires
are used to connect the converters on a PCB to an external
load, the Sense leads should be twisted together to reduce
noise pickup.
+OUT
+S
SC
Module N+1
–S
–OUT
Figure 11 — N+1 module array output connections
Pin Styles*
Designator
Description
Short
Finish
Tin/Lead
Tin/Lead
Gold
Notes
(None)
Requires inboard mounting
L
S
Long
Onboard mounting for 0.065in boards
Short ModuMate
Long ModuMate
Short RoHS
Long RoHS
SurfMate or inboard socket mounting
N
F
Gold
Onboard socket mounting
Gold
Select for RoHS-compliant inboard solder, socket or SurfMate mounting
Select for RoHS-compliant onboard solder or socket mounting
G
K
Gold
Extra Long RoHS
Gold
Select for RoHS compliance onboard mounting for thicker PCBs
(not intended for socket or Surfmate mounting)
* Pin style designator follows the “B” after the output power and precedes the baseplate designator.
Ex. V24B12T250BN2 — Long ModuMate Pins
Storage
Vicor products, when not installed in customer units, should be
stored in ESD safe packaging in accordance with ANSI/ESD S20.20,
“Protection of Electrical and Electronic Parts, Assemblies and
Equipment” and should be maintained in a temperature controlled
factory/ warehouse environment not exposed to outside elements
controlled between the temperature ranges of 15°C and 38°C.
Humidity shall not be condensing, no minimum humidity when
stored in an ESD compliant package.
24V Mini Family
Page 13 of 15
Rev 5.6
02/2021
24V Input
Mechanical Drawings
Converter Pins
Ref Dwg. 37206 rev 3
No. Function Label
kl{hpsGX
YGaGX
1
+IN
+
Primary
Control
2
PC
3
4
5
6
Parallel
–IN
PR
–
–OUT
–Sense
–
–S
Secondary
Control
7
SC
8
9
+Sense
+OUT
+S
+
L
SLOTTED BASEPLATE
2. DIMENSIONS AND VALUES IN BRACKETS ARE METRIC
3. MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING
BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD
OF THE APPLICATION RANGES FROM DIRECT CONTACT (ZERO), TO THE
MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACK-UP
AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION
Figure 12 — Module outline
INBOARD
SOLDER
MOUNT
ONBOARD
SOLDER
MOUNT
ALL MARKINGS
THIS SURFACE
SHORT PIN STYLE
0.094 0.003
LONG PIN STYLE
0.094 0.003
2,39 0,08
0.062 0.010
PCB THICKNESS
(7X)
1,57 0,25
2,39 0,08
PLATED
THROUGH HOLE
0.164 0.003
4,16 0,08
0.164 0.003
4,16 0,08
(2X)
1.790**
45,47
DIA
0.06
1,5
R
(4X)
0.158
4,01
ALUMINUM
BASEPLATE
PINS STYLES
1
9
2
8
3
6
4
5
SOLDER:TIN / LEAD PLATED
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
1.575**
40,00
1.900*
48.,26
For Soldering Methods and Procedures
Please refer to:
7
The Maxi, Mini, Micro Design Guide.
Unless otherwise specified,
dimensions are in inches
mm
0.400*
10,16
0.53
13,5
0.45
11,5
0.700*
17,78
Decimals
Tol.
Angles
1.000*
25,40
1.400*
35,56
0.XX
±0.01
±0.25
0.003
0,08
* DENOTES TOL =
±1°
0.195
4,95
0.XXX
±0.005
±0.127
** PCB WINDOW
Figure 13 — PCB mounting specifications
24V Mini Family
Page 14 of 15
Rev 5.6
02/2021
24V Input
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/dc-dc-converters-board-mount/high-density-dc-dc-converters for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Contact Us: http://www.vicorpower.com/contact-us
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
www.vicorpower.com
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
©2018 – 2021 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.
All other trademarks, product names, logos and brands are property of their respective owners.
24V Mini Family
Page 15 of 15
Rev 5.6
02/2021
V24B12C150BS 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
V24B12C150BS2 | VICOR | 24V Input Mini Family DC-DC Converter Module | 获取价格 | |
V24B12C150BS3 | VICOR | 24V Input Mini Family DC-DC Converter Module | 获取价格 | |
V24B12C200B | VICOR | 24Vin / 12Vout / 200Watts DC-DC Converter Module | 获取价格 | |
V24B12C200B2 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, MODULE-9 | 获取价格 | |
V24B12C200B3 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, MODULE-9 | 获取价格 | |
V24B12C200BF | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, MODULE-9 | 获取价格 | |
V24B12C200BF2 | VICOR | 24V Input Mini Family DC-DC Converter Module | 获取价格 | |
V24B12C200BF3 | VICOR | 24V Input Mini Family DC-DC Converter Module | 获取价格 | |
V24B12C200BG | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, MODULE-9 | 获取价格 | |
V24B12C200BG2 | VICOR | 24V Input Mini Family DC-DC Converter Module | 获取价格 |
V24B12C150BS 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6