V24B28C250BK2 概述
DC-DC Converter Module
V24B28C250BK2 数据手册
通过下载V24B28C250BK2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Mini Family
24V Input
Actual size:
2.28 x 2.2 x 0.5in
57,9 x 55,9 x 12,7mm
S
®
C
NRTL US
C
US
DC-DC Converter Module
Features & Benefits
Applications
• DC input range: 18 – 36V
• Isolated output
Industrial and process control, distributed power, medical, ATE, communications, defense,
and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
• Operation to 16V at 75% power
after startup
• Input surge withstand: 50V for 100ms
• DC output: 3.3 – 48V
Absolute Maximum Ratings
• Programmable output: 10 to 110%
• Regulation: 0.5% no load to full load
• Efficiency: Up to 89%
Parameter
Rating
-0.5 to +53
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
1.0
Unit
VDC
VDC
VDC
VDC
VDC
Notes
+In to –In voltage
PC to –In voltage
PR to –In voltage
SC to -Out voltage
-Sense to -Out voltage
• Maximum operating temp: 100°C,
full load
• Power density: up to 80 W per cubic inch
• Height above board: 0.43in. (10,9mm)
• Parallelable, with N+M fault tolerance
• Low noise ZCS/ZVS architecture
Isolation voltage
in to out
3000
1500
VRMS
VRMS
Test voltage
Test voltage
Test voltage
M-Grade
• RoHS Compliant (with F or G pin option)
in to base
out to base
500
VRMS
Product Overview
Operating Temperature
Storage Temperature
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
°C
°C
M-Grade
These DC-DC converter modules use advanced
power processing, control and packaging tech-
nologies to provide the performance, flexibility,
reliability and cost effectiveness of a mature
power component.
°F (°C)
°F (°C)
in-lbs (N-m)
<5 sec; wave solder
<7 sec; hand solder
6 each
Pin soldering temperature
Mounting torque
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
24B
B
e.g. V24B12T200BL2
Output Power
VOUT POUT
3.3V 100W, 150W
5V 150W, 200W
6.5V 200W
8V 200W
Product Grade Temperatures (°C)
Pin Style
Blank: Short
L: Long
S: Short ModuMate
N: Long ModuMate
F: Short RoHS
G: Long RoHS
K: Extra Long RoHS
Finish
Tin/Lead
Baseplate
Blank: Slotted
2: Threaded
Product Type
Output Voltage
3V3 = 3.3V
5 = 5V
6.5 = 6.5V
8 = 8V
12 = 12V
15 = 15V
24 = 24V
28 = 28V
36 = 36V
48 = 48V
Grade
Operating
Storage
V = Standard
S = Enhanced
efficiency
E
C
=
=
=
=
=
-
-
-
-
-
10 to +100
20 to +100
40 to +100
40 to +100
55 to +100
-
-
-
-
-
20 to +125
40 to +125
40 to +125
55 to +125
65 to +125
Tin/Lead
Gold
3: Through-hole
T
Gold
(avail. ≤12
Vout only)
H
M
Gold
12V 150W, 200W, 250W
15V 150W, 200W
Gold
Gold
24V 150W, 200W, 250W
28V 150W, 200W, 250W
36 V 150W, 200W
48 V 150W, 200W, 250W
24V Mini Family
Page 1 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
36
Unit
VDC
VDC
VDC
VDC
VDC
VDC
Notes
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
18
24
50
<100ms
17.5
15.3
37.8
17.9
14.8
36.3
39.6
4.0
PC pin low
MODULE OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Max
1ꢀ
Unit
VOUT nom.
ꢀ
Notes
Output voltage setpoint
Line regulation
Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100ꢀ of full load
0.02
0.002
2
0.20
0.005
5
Temperature regulation
Power sharing accuracy
ꢀ/°C
ꢀ
Of nominal output voltage. For trimming below 90ꢀ
of nominal, a minimum load of 10ꢀ of maximum
rated power may be required.
Programming range
10
110
ꢀ
+Out to –Out, +Sense to –Out — Absolute Maximum Ratings
3.3V
5V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 9.1
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
6.5V
8V
12V
15V
24V
28V
36V
48V
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,
contact Vicor applications engineering at 800-927-9474.
THERMAL RESISTANCE AND CAPACITY
Parameter
Min
Typ
0.16
0.14
8.0
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Thermal capacity
1.9
83
24V Mini Family
Page 2 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
5.50
1.5
5.75
2.1
6.00
3.0
VDC
mA
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
PC module disable
PC module enable delay
PC module alarm
2.3
2.6
4
2.9
7
VDC
ms
Switch must be able to sink ≥4mA. See Fig. 2
0.5
1.1
6.1
Vavg
MΩ
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC resistance
0.9
5.7
150
375
2.4
1.0
5.9
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Volts
mA
500
2.5
625
2.6
12
Ω
25°C
Volts
modules
Minimum pulse width: 20ns
Without PR buffer amplifier
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
1.21
990
1.23
1000
0.033
1.25
VDC
Ω
Referenced to –Sense
1010
SC capacitance
µF
SC module alarm
0
VDC
With open trim; referenced to –Sense. See Fig. 7
MODULE GENERAL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Remote sense (total drop)
0.5
VDC
0.25V per leg (sense leads must be connected to
respective, output terminals)
Isolation test voltage (in to out)*
Isolation test voltage (in to base)*
Isolation test voltage (out to base)*
3000
1500
500
VRMS
VRMS
VRMS
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
Isolation resistance
10
MΩ
in to out, in to baseplate, out to baseplate
3.1
3.5
3.9
ounces
(grams)
Weight (E, C, T grade)
(89.3)
(100.3)
(111.3)
3.5
3.9
4.3
ounces
(grams)
Weight (H, M grade)
(99.6)
(110.6)
(121.6)
Temperature limiting
Agency approvals
100
115
°C
See Figs. 3 and 5. Do not operate coverter >100C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
cURus, cTÜVus, CE
* Isolation test voltage, 1 minute or less.
Note: Specifications are subject to change without notice.
24V Mini Family
Page 3 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3VOUT, 150W (e.g. S24B3V3C150BL, V24B3V3C150BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B3V3C150BL (enhanced efficiency)
V24B3V3C150BL (standard efficiency)
Ripple and noise
84.0
80.0
86.5
81.4
160
4.3
ꢀ
Nominal input; full load; 25°C
200
4.46
6
mV
Volts
Watts
ꢀ
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP setpoint
Dissipation, standby
Load regulation
4.14
5
0.02
0.2
No load to full load; nominal input
Load current
0
45.45
61.5
61.5
Amps
Amps
Amps
Current limit
46.4
31.8
52.3
52.3
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
3.3VOUT, 100W (e.g. S24B3V3C100BL, V24B3V3C100BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B3V3C100BL (enhanced efficiency)
V24B3V3C100BL (standard efficiency)
Ripple and noise
83.5
80.4
85.1
81.4
71
ꢀ
Nominal input; full load; 25°C
89
4.46
3
mV
Volts
Watts
ꢀ
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP setpoint
Dissipation, standby
Load regulation
4.14
4.3
2.5
0.02
0.2
30.3
41
No load to full load; nominal input
Load current
0
Amps
Amps
Amps
Current limit
30.9
21.2
34.8
34.8
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
41
5VOUT, 200W (e.g. S24B5C200BL, V24B5C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B5C200BL (enhanced efficiency)
V24B5C200BL (standard efficiency)
Ripple and noise
85.9
80.5
87.0
84.9
95
ꢀ
Nominal input; full load; 25°C
119
6.53
5.5
mV
Volts
Watts
ꢀ
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP setpoint
Dissipation, standby
Load regulation
6.07
6.3
5.1
0.02
0.45
40
No load to full load; nominal input
Load current
0
Amps
Amps
Amps
Current limit
40.8
28
52
52
54.5
62
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
5VOUT, 150W (e.g. S24B5C150BL, V24B5C150BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B5C150BL (enhanced efficiency)
V24B5C150BL (standard efficiency)
Ripple and noise
86.0
83.5
87.2
84.8
50
ꢀ
Nominal input; full load; 25°C
63
6.47
4.5
mV
Volts
Watts
ꢀ
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP setpoint
Dissipation, standby
Load regulation
6.03
6.25
3.7
0.02
0.2
No load to full load; nominal input
Load current
0
30.6
5
30
Amps
Amps
Amps
Current limit
34.5
34.5
40.5
40.5
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
24V Mini Family
Page 4 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
6.5VOUT, 200W (e.g. S24B6V5C200BL, V24B6V5C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B6V5C200BL (enhanced efficiency)
V24B6V5C200BL (standard efficiency)
Ripple and noise
84.5
83.2
87.5
84.6
182
8.0
ꢀ
Nominal input; full load; 25°C
230
8.3
mV
Volts
Watts
ꢀ
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP setpoint
Dissipation, standby
Load regulation
7.7
5.3
6.2
0.02
0.2
No load to full load; nominal input
Load current
0
30.8
41.5
41.5
Amps
Amps
Amps
Current limit
31.4
21.5
35.4
35.4
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
8VOUT, 200W (e.g. S24B8C200BL, V24B8C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B8C200BL (enhanced efficiency)
V24B8C200BL (standard efficiency)
Ripple and noise
87.0
85.0
89.0
86.4
200
9.7
ꢀ
Nominal input; full load; 25°C
250
10.1
6
mV
Volts
Watts
ꢀ
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP setpoint
Dissipation, standby
Load regulation
9.36
5
0.02
0.2
No load to full load; nominal input
Load current
0
25
Amps
Amps
Amps
Current limit
25.5
17.5
28.8
28.8
33.8
33.8
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
12VOUT, 250W (e.g. S24B12C250BL, V24B12C250BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B12C250BL (enhanced efficiency)
V24B12C250BL (standard efficiency)
Ripple and noise
87.0
86.0
89.0
87.4
172
14.3
6.5
ꢀ
Nominal input; full load; 25°C
215
14.8
7.6
mV
Volts
Watts
ꢀ
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP setpoint
Dissipation, standby
Load regulation
13.8
0.02
0.2
No load to full load; nominal input
Load current
0
20.8
28.1
28.1
Amps
Amps
Amps
Current limit
21.3
14.6
24.0
24.0
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
12VOUT, 200W (e.g. S24B12C200BL, V24B12C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B12C200BL (enhanced efficiency)
V24B12C200BL (standard efficiency)
Ripple and noise
87.0
87.0
90.0
88.0
360
14.4
4.6
ꢀ
Nominal input; full load; 25°C
450
15
mV
Volts
Watts
ꢀ
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP setpoint
Dissipation, standby
Load regulation
13.8
7.4
0.02
0.2
No load to full load; nominal input
Load current
0
16.67
22.6
22.6
Amps
Amps
Amps
Current limit
17
19.2
19.2
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
11.6
24V Mini Family
Page 5 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
12VOUT, 150W (e.g. S24B12C150BL, V24B12C150BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S24B12C150BL (enhanced efficiency)
V24B12C150BL (standard efficiency)
Ripple and noise
87.5
87.0
90.0
88.6
200
14.3
4.5
ꢀ
Nominal input; full load; 25°C
250
14.9
5.4
mV
Volts
Watts
ꢀ
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP setpoint
Dissipation, standby
Load regulation
13.7
0.02
0.2
No load to full load; nominal input
Load current
0
12.5
16.9
16.9
Amps
Amps
Amps
Current limit
12.7
8.75
14.4
14.4
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
15VOUT, 200W (e.g. V24B15C200BL)
Parameter
Min
Typ
88.9
250
17.8
3.4
Max
Unit
ꢀ
Notes
Efficiency
88.0
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
313
18.5
3.8
mV
17.1
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
13.33
17.3
17.3
Amps
Amps
Amps
Current limit
13.5
13.5
15.9
16.1
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
15VOUT, 150W (e.g. V24B15C150BL)
Parameter
Min
Typ
88.9
200
17.8
4.4
Max
Unit
ꢀ
Notes
Efficiency
88.0
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
250
18.5
5.4
mV
17.1
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
10.2
7
10
Amps
Amps
Amps
Current limit
11.5
11.5
13.5
13.5
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
24VOUT, 250W (e.g. V24B24C250BL)
Parameter
Min
Typ
87.0
300
28.1
7.7
Max
Unit
ꢀ
Notes
Efficiency
86.0
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
360
29.1
9.0
mV
27.1
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
10.4
14.1
14.1
Amps
Amps
Amps
Current limit
10.6
7.3
12.0
12.0
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
24V Mini Family
Page 6 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
24VOUT, 200W (e.g. V24B24C200BL)
Parameter
Min
Typ
87.0
260
28.5
5.1
Max
Unit
ꢀ
Notes
Efficiency
85.4
Nominal input; full load; 25°C
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
325
29.5
6.2
mV
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
27.5
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
8.33
11.5
11.5
Amps
Amps
Amps
Current limit
8.46
5.81
9.8
9.8
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
24VOUT, 150W (e.g. V24B24C150BL)
Parameter
Min
Typ
87.7
200
28.1
4.7
Max
Unit
ꢀ
Notes
Efficiency
86.5
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
250
29.1
5.1
mV
27.1
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
6.37
3
6.25
8.44
8.44
Amps
Amps
Amps
Current limit
7.19
7.19
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
28VOUT, 250W (e.g. V24B28C250BL)
Parameter
Min
Typ
88.7
133
32.7
9.6
Max
Unit
ꢀ
Notes
Efficiency
87.2
Nominal input; full load; 25°C
p-p Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
166
33.8
10.5
0.2
mV
31.5
Volts
Watts
ꢀ
0.02
No load to full load; nominal input
0
8.9
Amps
Amps
Amps
Current limit
9.1
6.3
10.3
10.3
12.1
12.1
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
28VOUT, 200W (e.g. V24B28C200BL)
Parameter
Min
Typ
87.0
180
32.8
4.5
Max
Unit
ꢀ
Notes
Efficiency
85.0
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
225
34
mV
31.6
Volts
Watts
ꢀ
5.5
0.02
0.2
No load to full load; nominal input
0
7.29
5
7.14
9.66
9.66
Amps
Amps
Amps
Current limit
8.22
8.22
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
24V Mini Family
Page 7 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
28VOUT, 150W (e.g. V24B28C150BL)
Parameter
Min
Typ
87.8
200
32.7
4.3
Max
Unit
ꢀ
Notes
Efficiency
86.5
Nominal input; full load; 25°C
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
250
33.9
5.2
mV
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
31.5
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
5.36
7.24
7.24
Amps
Amps
Amps
Current limit
5.46
3.75
6.16
6.16
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
36VOUT, 200W (e.g. V24B36C200BL)
Parameter
Min
Typ
88.0
200
41.9
4.5
Max
Unit
ꢀ
Notes
Efficiency
87.0
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
250
43.4
5.3
mV
40.4
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
5.55
7.51
7.51
Amps
Amps
Amps
Current limit
5.67
3.89
6.39
6.39
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
36VOUT, 150W (e.g. V24B36C150BL)
Parameter
Min
Typ
88.0
200
41.9
4.2
Max
Unit
ꢀ
Notes
Efficiency
86.7
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
250
43.4
5
mV
40.4
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
4.17
5.63
5.63
Amps
Amps
Amps
Current limit
4.25
2.91
4.8
4.8
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
48VOUT, 250W (e.g. V24B48C250BL)
Parameter
Min
Typ
89.1
182.0
55.7
7.4
Max
Unit
ꢀ
Notes
Efficiency
87.6
Nominal input; full load; 25°C
p-p Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
228.0
57.6
8.5
mV
53.8
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
5.2
Amps
Amps
Amps
Current limit
5.3
3.6
6.0
6.0
7.0
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
7.0
24V Mini Family
Page 8 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
48VOUT, 200W (e.g. V24B48C200BL)
Parameter
Min
Typ
87.5
225
55.8
5.4
Max
Unit
ꢀ
Notes
Efficiency
86.0
Nominal input; full load; 25°C
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
282
57.8
5.8
mV
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
53.8
Volts
Watts
ꢀ
0.02
0.5
No load to full load; nominal input
0
4.17
5.63
5.63
Amps
Amps
Amps
Current limit
4.25
2.91
4.8
4.8
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
48VOUT, 150W (e.g. V24B48C150BL)
Parameter
Min
Typ
88.9
125
55.7
3.7
Max
Unit
ꢀ
Notes
Efficiency
87.9
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
157
57.7
4.2
mV
53.7
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
3.13
4.23
4.33
Amps
Amps
Amps
Current limit
3.19
2.19
3.6
3.6
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
24V Mini Family
Page 9 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
Basic Module Operation
C2*
4.7nF
C4*
4.7nF
+IN
PC
PR
+OUT
+S
F1*
SC
C1*
0.2µF
–S
–IN
–OUT
C3*
4.7nF
C5*
4.7nF
For C1 – C5, keep leads and connections short.
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Maxi, Mini, Micro Design Guide.
Comprehensive Online Application Information
The Design Guide and Applications Manual includes:
• Application circuits
• Design requirements
• EMC considerations
• Current sharing in power arrays
• Thermal performance information
• Recommended soldering methods
• Accessory modules – filtering, rectification, front-ends
• Mounting options
• ...and more.
CLICK HERE TO VIEW
DESIGN GUIDE
Also at vicorpower.com
• PowerBench online configurators
• Over 20 Application Notes
• Online calculators – thermal, trimming, hold-up
• PDF data sheets for ALL Vicor products
24V Mini Family
Page 10 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
Primary Control - PC PIN
Module Enable/Disable
Module Alarm
The module may be disabled by pulling PC to 0V (2.3V max)
with respect to the –Input. This may be done with an open
collector transistor, relay, or optocoupler. Converters may be
disabled with a single transistor or relay either directly or via
“OR’ing” diodes for 2 or more converters. See Figure 2.
The module contains “watchdog” circuitry which monitors input
voltage, operating temperature and internal operating parame-
ters. In the event that any of these parameters are
outside of their allowable operating range, the module will shut
down and PC will go low. PC will periodically go high and the
module will check to see if the fault (as an example,
Primary Auxiliary Supply
Input Undervoltage) has cleared. If the fault has not been
cleared, PC will go low again and the cycle will restart. The SC
pin will go low in the event of a fault and return to its normal
state after the fault has been cleared. See Figures 3 and 5.
During normal operation only, the PC Pin can source 5.7V @
1.5mA. In the example shown in Figure 4, PC powers a module
enabled LED.
Input Undervoltage
Input Overvoltage (See Note 1)
+OUT
+IN
PC
+In
PC
+Out
Overtemperature
Module Faults
Auto
Restart
SW1
+S
SC
–S
+S
SC
–S
2-20 ms typ.
50 Ω
f (V
)
IN
SW1, 2, & 3
shown in
"Fault" position
1 K
6 K
SW2
SW3
1 M
PR
Disable
PR
–In
5.7 Vdc
(0-3 mA)
–IN
1.23
Vdc
– OUT
–Out
Disable = PC <2.3V
1
Not applicable for 300 Vdc input family
Figure 3 — PC/SC module alarm logic
Figure 2 — Module enable/disable
+In
+Out
Fault
PC
40 μs typ.
5.7 V
PC
+S
SC
–S
4kΩ
"Module
PR
–In
Enabled"
1.23 V
2–20 ms typ.
SC
–Out
Figure 4 — LED on-state indicator
Figure 5 — PC/SC module alarm timing
Optocoupler
+In
PC
+In
PC
+Out
+Out
+S
SC
–S
+S
SC
–S
4 kΩ
Alarm
PR
–In
PR
–In
1.00V
–Out
–Out
Figure 7 — Secondary side on-state indicator
Figure 6 — Isolated on-state indicator
24V Mini Family
Page 11 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
Secondary Control - SC PIN
Parallel Bus - PR PIN
Output Voltage Programming
Parallel Operation
The output voltage of the converter can be adjusted or
programmed via fixed resistors, potentiometers or voltage DACs.
See Figure 8.
The PR pin supports paralleling for increased power with N+1
(N+M) redundancy. Modules of the same input voltage, output
voltage, and power level will current share if all PR pins are suitably
interfaced.
Compatible interface architectures include the following:
+OUT
+S
AC coupled single-wire interface. All PR pins are connected
to a single communication bus through 0.001µF (500V)
capacitors. This interface supports current sharing and is fault
tolerant except for the communication bus. Up to three
converters may be paralleled by this method. See Figure 9.
Error Amplifier
Ru
Trim Up
–
SC
+
Transformer coupled interface. For paralleling four or more
converters a transformer coupled interface is required.
See Figure 10.
Load
1 kΩ
Rd
Trim Down
0.033 uF
1.23 V
-S
For details on parallel operation please refer to the
100 Ω typ.
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
–OUT
4.7 nF
1,000 Vout
Vnom – Vout
Rd (ohms) =
+
–
+IN
PC
PR
–IN
0.2 µF
Z1*
1,000 (Vout –1.23) Vnom
Module 1
Module 2
RU (ohms) =
0.001 µF
– 1,000
1.23 (Vout – Vnom)
Figure 8 — Output voltage trim down and trim up circuit
4.7 nF
4.7 nF
0.2 µF
Low inductance
ground plane
or bus
Trim Down
+IN
PC
PR
–IN
1. This converter is not a constant power device – it has a
constant current limit. Hence, available output power is
reduced by the same percentage that output voltage is
trimmed down. Do not exceed maximum rated
outputcurrent.
0.001 µF
Z1*
4.7 nF
Parallel
Bus
2.The trim down resistor must be connected between the SC
and -S pins. Do not bypass the SC pin directly
with a capacitor.
Figure 9 — AC coupled single-wire interface
* See Maxi, Mini, Micro Design Guide
Trim Up
1. The converter is rated for a maximum delivered power. To
ensure that maximum rated power is not exceeded, reduce
maximum output current by the same percentage increase in
output voltage.
4.7 nF
+IN
+
–
0.2 µF
PC
Module 1
T1
Z1*
2.The trim up resistor must be connected between the SC
and +S pins. Do not bypass the SC pin directly
with a capacitor.
PR
–IN
4.7 nF
4.7 nF
3. Do not trim the converter above maximum trim range
(typically +10ꢀ) or the output over voltage protection
circuitry may be activated.
+IN
PC
PR
–IN
0.2 µF
Z1*
Module 2
T2
Trim resistor values calculated automatically:
On-line calculators for trim resistor values are available
on the vicor website at:
asp.vicorpower.com/calculators/calculators.asp?calc=1
Resistor values can be calculated for fixed trim up, fixed
trim down and for variable trim up or down.
4.7 nF
Parallel
Bus
Figure 10 — Transformer-coupled interface
24V Mini Family
Page 12 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
Parallel Bus Output
+OUT
• The +Out and –Out power buses should be designed to
minimize and balance parasitic impedance from each
module output to the load.
+S
SC
–S
Module 1
Module 2
• The +Sense pins must be tied together to form a
+Sense bus. This must be Kelvin connected to +Out at a
single point. The –Sense pins should be tied together to
form a –Sense bus. This must be Kelvin connected to –Out
at a single point.
–OUT
+S
–S
+OUT
+S
SC
–S
• At the discretion of the power system designer, a subset
of all modules within an array may be configured as slaves
by connecting SC to –S.
Load
–OUT
• OR’ing diodes may be inserted in series with the +Out pins
of each module to provide module output fault tolerance.
• The +Sense and -Sense leads should be routed in close
proximity to each other on the printed circuit board. If wires
are used to connect the converters on a PCB to an external
load, the Sense leads should be twisted together to reduce
noise pickup.
+OUT
+S
SC
Module N+1
–S
–OUT
Figure 11 — N+1 module array output connections
PIN STYLES*
Designator
Description
Short
Finish
Tin/Lead
Tin/Lead
Gold
Notes
(None)
Requires in-board, mounting
L
S
Long
On-board mounting for 0.065” boards
Short ModuMate
Long ModuMate
Short RoHS
Long RoHS
SurfMate or in-board socket mounting
N
F
Gold
On-board socket mounting
Gold
Select for RoHS compliant in-board solder, socket, or SurfMate mounting
Select for RoHS compliant on-board solder or socket mounting
G
K
Gold
Extra Long RoHS
Gold
Select for RoHS compliance on-board mounting for thicker PCBs
(not intended for socket or Surfmate mounting)
* Pin style designator follows the “B” after the output power and precedes the baseplate designator.
Ex. V24B12T250BN2 — Long ModuMate Pins
24V Mini Family
Page 13 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
Mechanical Drawings
Converter Pins
No. Function Label
1
+In
+
Primary
Control
2
PC
3
4
5
6
Parallel
–In
PR
–
–Out
–
–Sense
–S
Secondary
Control
7
SC
8
9
+Sense
+Out
+S
+
DIMENSION L
PIN SHORT – .55±.ꢀ05 ꢁ01.ꢀ±.±ꢂ3
PIN LONG–– .6±±.ꢀ05 ꢁ06.ꢀ±.±ꢂ3
PIN EXTRA LONG–––- .70±.ꢀ05 ꢁ0ꢂ.ꢀ±.±ꢂ3
NOTES:
1.MATERIAL:
BASE:
6000 SERIES ALUMINUM
COVER: LCP, ALUMINUM 3003 H14
PINS:
PINS:
RoHS PINS GOLD PLATE 30 MICRO INCH MIN; NON-RoHS
TIN/LEAD 90/10 BRIGHT
2.DIMENSIONS AND VALUES IN BRACKETS ARE METRIC
3.MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING
BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD
OF THE APPLICATION RANGES FROM DIRECT CONTACT (ZERO), TO THE
MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACK-UP
AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION
Figure 12 — Module outline
INBOARD
SOLDER
MOUNT
ONBOARD
SOLDER
MOUNT
ALL MARKINGS
THIS SURFACE
SHORT PIN STYLE
0.094 0.003
LONG PIN STYLE
0.062 0.010
PCB THICKNESS
0.094 0.003
2,39 0,08
(7X)
1,57 0,25
2,39 0,08
PLATED
THROUGH HOLE
DIA
0.164 0.003
4,16 0,08
0.164 0.003
4,16 0,08
(2X)
1.790**
45,47
0.06
1,5
R
(4X)
0.158
4,01
ALUMINUM
BASEPLATE
PINS STYLES
1
2
3
4
SOLDER:TIN / LEAD PLATED
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
1.575**
40,00
1.900*
48.,26
For Soldering Methods and Procedures
Please refer to:
9
8
7
6
5
THE MAXI, MINI, MICRO Design Guide.
0.400*
10,16
11,5
0.53
13,5
0.45
Unless otherwise specified,
dimensions are in inches
mm
0.700*
17,78
1.000*
25,40
1.400*
35,56
Decimals
Tol.
Angles
0.003
0,08
* DENOTES TOL =
0.XX
±0.01
±0.25
0.195
4,95
±1°
** PCB WINDOW
0.XXX
±0.005
±0.127
Figure 13 — PCB mounting specifications
24V Mini Family
Page 14 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
24V Input
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and ac-
cessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power
systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls
are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of
all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DIS-
CLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY,
FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER
MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operat-
ing safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
24V Mini Family
Page 15 of 15
Rev 4.9
vicorpower.com
800 927.9474
01/2016
V24B28C250BK2 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
V24B28C250BK3 | VICOR | DC-DC Converter Module | 获取价格 | |
V24B28C250BL | VICOR | CONVERTER MOD DC/DC 28V 250W | 获取价格 | |
V24B28C250BL2 | VICOR | DC-DC Converter Module | 获取价格 | |
V24B28C250BL3 | VICOR | CONVERTER MOD DC/DC 28V 250W | 获取价格 | |
V24B28C250BN | VICOR | DC-DC Converter Module | 获取价格 | |
V24B28C250BN2 | VICOR | CONVERTER MOD DC/DC 28V 250W | 获取价格 | |
V24B28C250BN3 | VICOR | CONVERTER MOD DC/DC 28V 250W | 获取价格 | |
V24B28C250BS | VICOR | CONVERTER MOD DC/DC 28V 250W | 获取价格 | |
V24B28C250BS2 | VICOR | CONVERTER MOD DC/DC 28V 250W | 获取价格 | |
V24B28C250BS3 | VICOR | CONVERTER MOD DC/DC 28V 250W | 获取价格 |
V24B28C250BK2 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6