V28C5C50BS
更新时间:2024-09-18 17:02:02
品牌:VICOR
描述:DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, PACKAGE-7
V28C5C50BS 概述
DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, PACKAGE-7 电源模块
V28C5C50BS 规格参数
是否无铅: | 含铅 | 是否Rohs认证: | 不符合 |
生命周期: | Active | 零件包装代码: | MODULE |
包装说明: | DFM, | 针数: | 7 |
Reach Compliance Code: | not_compliant | ECCN代码: | EAR99 |
风险等级: | 5.24 | 模拟集成电路 - 其他类型: | APSM DCDC |
控制模式: | VOLTAGE-MODE | 最大输入电压: | 36 V |
最小输入电压: | 9 V | 标称输入电压: | 28 V |
JESD-30 代码: | R-XDFM-P7 | JESD-609代码: | e4 |
最大电网调整率: | 0.2% | 最大负载调整率: | 0.2% |
功能数量: | 1 | 输出次数: | 1 |
端子数量: | 7 | 最高工作温度: | 100 °C |
最低工作温度: | -20 °C | 最大输出电压: | 5.5 V |
最小输出电压: | 0.5 V | 标称输出电压: | 5 V |
封装主体材料: | UNSPECIFIED | 封装代码: | DFM |
封装形状: | RECTANGULAR | 封装形式: | MICROELECTRONIC ASSEMBLY |
认证状态: | Not Qualified | 表面贴装: | NO |
技术: | HYBRID | 温度等级: | OTHER |
端子面层: | Gold (Au) | 端子形式: | PIN/PEG |
端子位置: | DUAL | 最大总功率输出: | 50 W |
微调/可调输出: | YES | Base Number Matches: | 1 |
V28C5C50BS 数据手册
通过下载V28C5C50BS数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Micro Family
28V Wide Input
Actual size:
2.28 x 1.45 x 0.5in
57,9 x 36,8 x 12,7mm
S
®
C
NRTL US
C
US
DC-DC Converter Module
Features & Benefits
Applications
• DC input range: 9 – 36V*
• Isolated output
Industrial and process control, distributed power, medical, ATE, communications,
defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
• Input surge withstand: 50V for 100ms
• DC output: 3.3 – 48V
• Programmable output: 10 to 110%
• Regulation: 0.2% no load to full load
• Efficiency: Up to 81%
Absolute Maximum Ratings
• Maximum operating temp: 100°C,
full load
Parameter
Rating
Unit
VDC
VDC
VDC
VDC
Notes
+IN to -IN voltage
PC to -IN voltage
PR to -IN voltage
SC to -OUT voltage
-0.5 to +53
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
• Power density: up to 60W per cubic inch
• Height above board: 0.43in. (10,9mm)
• Parallelable, with N+M fault tolerance
• Low noise ZCS / ZVS architecture
Isolation voltage
IN to OUT
• RoHS Compliant (with F or G pin option)
3000
1500
VRMS
VRMS
Test voltage
Test voltage
Test voltage
M-Grade
IN to base
Product Overview
OUT to base
500
VRMS
Operating Temperature
Storage Temperature
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
°C
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
°C
M-Grade
°F (°C)
°F (°C)
in-lbs (N-m)
<5 sec; wave solder
<7 sec; hand solder
6 each
Pin soldering temperature
Mounting torque
High frequency ZCS / ZVS switching provides
high power density with low noise and
high efficiency.
*Derate power to 75% for 9 to 10VIN
Part Numbering
e.g. V28C12T100BL2
28C
B
Product Grade Temperatures (°C)
Output Power
Pin Style
Blank: Short
L: Long
S: Short ModuMate
N: Long ModuMate
F: Short RoHS
G: Long RoHS
K: Extra Long RoHS
Finish
Tin/Lead
Baseplate
Blank: Slotted
2: Threaded
Output Voltage
Product Type
VOUT
POUT
Grade
Operating
Storage
3V3 = 3.3V
5 = 5V
V = Standard
S = Enhanced
efficiency
3.3V
5V
50W
C
T
H
M
=
=
=
=
-
-
-
-
20 to +100
40 to +100
40 to +100
55 to +100
-
-
-
-
40 to +125
40 to +125
55 to +125
65 to +125
Tin/Lead
Gold
3: Through-hole
50W
12 = 12V
15 = 15V
24 = 24V
28 = 28V
36 = 36V
48 = 48V
12V
15V
24V
28V
36V
48V
100W
100W
100W
100W
100W
100W
Gold
(avail. ≤12
VOUT only)
Gold
Gold
Gold
28V Wide Micro Family
Page 1 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
VDC
From 9 to 10V input available power is reduced to 75%
Operating input voltage
9
28
36
of max rating
<100ms
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off / on
50
VDC
VDC
VDC
VDC
8.8
8.5
8.9
36.3
37.8
39.6
14
Disabled input current
12
mA
PC pin low
MODULE OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Max
1
Unit
%
Notes
Output voltage set point
Line regulation
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
0.02
0.002
2
0.20
0.005
5
%
Temperature regulation
Power sharing accuracy
% / °C
%
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
10
110
Programming range
%
+OUT to –OUT — Absolute Maximum Ratings
3.3V
5V
-0.5 to 4.7
-0.5 to 7.0
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
8V
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
12V
15V
24V
28V
36V
48V
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 7.
THERMAL RESISTANCE AND CAPACITY
Parameter
Min
Typ
0.24
0.21
10.9
2.8
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
48
28V Wide Micro Family
Page 2 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
5.50
1.5
5.75
2.1
6.00
3.0
VDC
mA
PC current = 1.0mA
PC voltage = 5.5V
PC module disable
PC module enable delay
PC module alarm
2.3
2.6
4
2.9
7
VDC
ms
Switch must be able to sink ≥4mA. See Fig. 2
0.5
1.1
6.1
Vavg
MΩ
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC resistance
0.9
5.7
150
375
2.4
1.0
5.9
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Volts
mA
500
2.5
625
2.6
12
Ω
25°C
Volts
modules
Minimum pulse width: 20ns
Without PR buffer amplifier
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
1.21
990
1.23
1000
0.033
1.25
VDC
Ω
Referenced to –Sense
1010
SC capacitance
µF
SC module alarm
0
VDC
With open trim; referenced to –Sense. See Fig. 7
MODULE GENERAL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
3000
1500
500
VRMS
VRMS
VRMS
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
Isolation resistance
10
MΩ
IN to OUT, in to baseplate, out to baseplate
1.9
2.1
2.3
ounces
(grams)
Weight (E, C, T grade)
(52.8)
(59.3)
(65.8)
2.1
2.3
2.5
ounces
(grams)
Weight (H, M grade)
Temperature limiting
Agency approvals
(58.7)
(65.2)
(71.7)
100
115
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
cURus, cTÜVus, CE
* Isolation test voltage, 1 minute or less.
Note: Specifications are subject to change without notice.
28V Wide Micro Family
Page 3 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3VOUT, 50W (e.g. S28C3V3C50BL, V28C3V3C50BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S28C3V3C50BL (enhanced efficiency)
V28C3V3C50BL (standard efficiency)
Ripple and noise
73.7
72.0
83.6
73.4
180
4.3
%
Nominal input; full load; 25°C
225
4.46
6.2
mV
Volts
Watts
%
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
4.14
5.2
0.02
0.2
No load to full load; nominal input
Load current
0
15.15
20.6
20.6
Amps
Amps
Amps
Current limit
15.5
10.6
17.5
17.5
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
5VOUT, 50W (e.g. S28C5C50BL, V28C5C50BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S28C5C50BL (enhanced efficiency)
V28C5C50BL (standard efficiency)
Ripple and noise
79.6
78.5
83.6
79.5
127
6.25
2.9
%
Nominal input; full load; 25°C
159
6.47
3.5
mV
Volts
Watts
%
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
6.03
0.02
0.2
No load to full load; nominal input
Load current
0
10.2
7
10
Amps
Amps
Amps
Current limit
11.5
11.5
13.5
13.5
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
12VOUT, 100W (e.g. S28C12C100BL, V28C12C100BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S28C12C100BL (enhanced efficiency)
V28C12C100BL (standard efficiency)
Ripple and noise
82.0
81.0
85.0
82.3
200
14.3
6.8
%
Nominal input; full load; 25°C
250
14.9
7.5
mV
Volts
Watts
%
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
13.7
0.02
0.2
No load to full load; nominal input
Load current
0
8.33
11.3
11.3
Amps
Amps
Amps
Current limit
8.49
5.83
9.58
9.58
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
28V Wide Micro Family
Page 4 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
15VOUT, 100W (e.g. V28C15C100BL)
Parameter
Min
Typ
80.7
200
17.8
7.1
Max
Unit
%
Notes
Efficiency
79.0
Nominal input; full load; 25°C
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
250
18.5
10
mV
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
17.1
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
6.67
9.01
9.01
Amps
Amps
Amps
Current limit
6.8
4.66
7.67
7.67
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
24VOUT, 100W (e.g. V28C24C100BL)
Parameter
Min
Typ
82.3
180
28.1
5.3
Max
Unit
%
Notes
Efficiency
81.3
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
225
29.1
6.2
mV
27.1
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
4.17
5.63
5.63
Amps
Amps
Amps
Current limit
4.25
2.91
4.8
4.8
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
28VOUT, 100W (e.g. V28C28C100BL)
Parameter
Min
Typ
80.6
160
32.7
7.6
Max
Unit
%
Notes
Efficiency
79.0
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
200
33.9
8.3
mV
31.5
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
3.57
5.35
5.35
Amps
Amps
Amps
Current limit
3.64
2.49
4.11
4.11
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
28V Wide Micro Family
Page 5 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
36VOUT, 100W (e.g. V28C36C100BL)
Parameter
Min
Typ
80.9
180
41.9
5.8
Max
Unit
%
Notes
Efficiency
79.5
Nominal input; full load; 25°C
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
225
43.4
6.2
mV
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
40.4
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
2.78
3.76
3.76
Amps
Amps
Amps
Current limit
2.83
1.94
3.2
3.2
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
48VOUT, 100W (e.g. V28C48C100BL)
Parameter
Min
Typ
79.7
125
55.7
7.4
Max
Unit
%
Notes
Efficiency
78.2
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
157
57.7
8.0
mV
53.7
Volts
Watts
%
0.02
0.2
No load to full load; nominal input
0
2.08
3.31
3.31
Amps
Amps
Amps
Current limit
2.12
1.45
2.39
2.39
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
28V Wide Micro Family
Page 6 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Basic Module Operation
C2*
4.7nF
C4*
4.7nF
+IN
PC
PR
+OUT
SC
F1*
C1*
0.2µF
–IN
–OUT
C3*
4.7nF
C5*
4.7nF
For C1 – C5, keep leads and connections short.
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Maxi, Mini, Micro Design Guide.
Output Connections and Considerations
leads must be protected for conditions such as lead reversal,
noise pickup, open circuit, or excessive output lead resistance
between the sense point and the converters output terminals.
For applications that may draw more than the rated current, a
fast acting electronic circuit breaker must be utilized to protect
the converter. Under no circumstance should the rated current
be exceeded. Utilizing or testing of current limit or short circuit
current will damage the converter. Ensure that the total output
capacitance connected to the converter does not exceed
the limits on Page 16, “Maximum Output Capacitance”, of
the design guide.
The permissible load current must never be exceeded during
normal, abnormal or test conditions. Converters subject to
dynamic loading exceeding 25% of rated current must be
reviewed by Vicor Applications Engineering to ensure that the
converter will operate properly.
Under dynamic load, light load, or no load conditions, the
converter may emit audible noise. Converters that utilize remote
sense may require compensation circuitry to offset the phase
lag caused by the external output leads and load impedance.
If an external remote sense circuit is used, the remote sense
The Design Guide and Applications Manual includes:
• Application circuits
Comprehensive Online Application Information
• Design requirements
• EMC considerations
• Current sharing in power arrays
• Thermal performance information
• Recommended soldering methods
• Accessory modules – filtering, rectification, front-ends
• Mounting options
• ...and more.
CLICK HERE TO VIEW
DESIGN GUIDE
Also at vicorpower.com
• PowerBench online configurators
• Over 20 Application Notes
• Online calculators – thermal, trimming, hold-up
• PDF data sheets for ALL Vicor products
28V Wide Micro Family
Page 7 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Primary Control - PC PIN
Module Enable/Disable
Module Alarm
The module may be disabled by pulling PC to 0V (2.3V max)
with respect to the –Input. This may be done with an open
collector transistor, relay, or optocoupler. Converters may be
disabled with a single transistor or relay either directly or via
“OR’ing” diodes for 2 or more converters. See Figure 2.
The module contains “watchdog” circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will shut
down and PC will go low. PC will periodically go high and the
module will check to see if the fault (as an example,
Primary Auxiliary Supply
Input Undervoltage) has cleared. If the fault has not been
cleared, PC will go low again and the cycle will restart. The SC
pin will go low in the event of a fault and return to its normal
state after the fault has been cleared. See Figures 3 and 5.
During normal operation only, the PC Pin can source 5.7V
@ 1.5mA. In the example shown in Figure 4, PC powers a
module enabled LED.
Input Undervoltage
[a]
Input Overvoltage
Over Temperature
+IN
+OUT
SC
Module Faults
+IN
PC
Auto
Restart
SW1
50Ω
PC
PR
2-20ms typ.
f(VIN)
1K
6K
SW2
SW3
5.7VDC
PR
1M
(0-3mA)
1.23
VDC
Disable
–IN
–OUT
SW1, 2, & 3 shown
in "Fault" position
–IN
[a]
Disable = PC < 2.3V
Not applicable for 300VDC Input family
Figure 2 — Module enable/disable
Figure 3 — PC/SC module alarm logic
+IN
PC
Fault
40µs typ.
5.7V
PC
4kΩ
"Module
PR
Enabled"
1.23V
2-20ms typ.
SC
–IN
Figure 4 — LED on-state indicator
Figure 5 —PC/SC module alarm timing
+IN
+OUT
SC
Comparator
Optocoupler
PC
Alarm
PR
4k
1.00V
–OUT
–IN
Figure 6 —Isolated on-state indicator
Figure 7 — Secondary side on-state indicator
28V Wide Micro Family
Page 8 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Compatible interface architectures include the following:
Secondary Control - SC PIN
AC coupled single-wire interface. All PR pins are connected
to a single communication bus through 0.001µF (500V)
capacitors. This interface supports current sharing and is fault
tolerant except for the communication bus. Up to three
converters may be paralleled by this method. See Figure 9.
Output Voltage Programming
The output voltage of the converter can be adjusted or
programmed via fixed resistors, potentiometers or voltage
DACs. See Figure 8.
Transformer coupled interface. For paralleling four or more
converters a transformer coupled interface is required, and under
certain conditions a PR buffer circuit.
+OUT
RU
For details on parallel operation please refer to the
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Trim Up
Error
Load
SC
Amp
RD
1kΩ
0.033μF
Trim Down
–OUT
4.7nF
1.23V
+
–
+IN
PC
PR
–IN
0.2µF
0.001µF
Module 1
Module 2
R1*
1,000VOUT
VNOM – VOUT
RD (Ω) =
RU (Ω) =
4.7nF
4.7nF
Low inductance
ground plane
or bus
1,000 (VOUT – 1.23) VNOM
1.23 (VOUT – VNOM
– 1,000
)
+IN
PC
PR
–IN
0.2µF
Figure 8 — Output voltage trim down and trim up circuit
0.001µF
R1*
Trim Down
4.7nF
1. This converter is not a constant power device – it has a
constant current limit. Hence, available output power is
reduced by the same percentage that output voltage is
trimmed down. Do not exceed maximum rated output current.
Parallel
Bus
Figure 9 — AC coupled single-wire interface
* See Maxi, Mini, Micro Design Guide
2. The trim down resistor must be connected between the SC
and -S pins. Do not bypass the SC pin directly with a capacitor.
4.7nF
+IN
+
–
Trim Up
0.2µF
R1*
PC
1. The converter is rated for a maximum delivered power. To
ensure that maximum rated power is not exceeded, reduce
maximum output current by the same percentage increase in
output voltage.
Module 1
T1
PR
–IN
4.7nF
4.7nF
2. The trim up resistor must be connected between the SC and
+IN
PC
PR
–IN
+S pins. Do not bypass the SC pin directly with a capacitor.
0.2µF
R1*
Module 2
T2
3. Do not trim the converter above maximum trim range (typically
+10%) or the output over voltage protection circuitry may
be activated.
4.7nF
Parallel
Bus
Trim resistor values calculated automatically:
Figure 10 — Transformer-coupled interface
On-line calculators for trim resistor values are available on
the vicor website at:
asp.vicorpower.com/calculators/calculators.asp?calc=1
Resistor values can be calculated for fixed trim up, fixed
trim down and for variable trim up or down.
Number of Converters in Parallel *R1 value Ω
2
75
50
33
3
Parallel Bus - PR PIN
4
Parallel Operation
5 or more
refer to application note:
Designing High-Power Arrays
using Maxi, Mini, Micro
Family DC-DC Converters
The PR pin supports paralleling for increased power with N+1
(N+M) redundancy. Modules of the same input voltage, output
voltage, and power level will current share if all PR pins are
suitably interfaced.
28V Wide Micro Family
Page 9 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Parallel Bus / Voltage Drop Compensation
+OUT
SC
• The +OUT and –OUT
power buses should be
designed to minimize
and balance parasitic
impedance from each
module output to the
load.
Plane
Module #1
Designated
Master
+OUT
SC
+S
R7 21.0k
*
C3
*
R4
–OUT
R9*
*
R1
R8
C2
4.02k
R3
0.22µF
U2
R5
U1
*
R2
2.55 k
TLV431
470pF
Vcc
1.00k
R Load
–
–
R11
R6
C1
36.5k
1.65k
+OUT
SC
200mV
+
+
R10
PS2701
U3
1.24k
LM10
• At the discretion of the
power system designer,
a subset of all modules
within an array may be
configured as slaves by
connecting SC
Gnd
L
O
A
D
Module #2
trimmed
–S
–OUT
down 2%
–OUT
*See Component Selection section below.
to –OUT.
+OUT
SC
• This module is designed for point of load regulation, where remote sensing
is not required. Active voltage drop compensator, as shown here, may be
used in applications with significant distribution losses.
Module #3
trimmed
• Do not use output
OR’ing diodes with
MicroMods.
Ground
Plane
down 4%
Please consult with the Micro Family Isolated Remote Sense Application Note
for additional information.
–OUT
Figure 11 — N+1 module array output connections
Figure 12 — Voltage drop compensation
PIN STYLES*
Designator
Description
Short
Finish
Tin/Lead
Tin/Lead
Gold
Notes
(None)
Requires in-board, mounting
L
S
Long
On-board mounting for 0.065” boards
Short ModuMate
Long ModuMate
Short RoHS
Long RoHS
SurfMate or in-board socket mounting
N
F
Gold
On-board socket mounting
Gold
Select for RoHS compliant in-board solder, socket, or SurfMate mounting
Select for RoHS compliant on-board solder or socket mounting
G
K
Gold
Extra Long RoHS
Gold
Select for RoHS compliance on-board mounting for thicker PCBs
(not intended for socket or Surfmate mounting)
* Pin style designator follows the “B” after the output power and precedes the baseplate designator.
Ex. V28C12T100BN2 — Long ModuMate Pins
Storage
Vicor products, when not installed in customer units, should be stored in ESD safe packaging in accordance with ANSI/ESD S20.20,
“Protection of Electrical and Electronic Parts, Assemblies and Equipment” and should be maintained in a temperature controlled factory/
warehouse environment not exposed to outside elements controlled between the temperature ranges of 15°C and 38°C. Humidity shall not
be condensing, no minimum humidity when stored in an ESD compliant package.
28V Wide Micro Family
Page 10 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Mechanical Drawings
Converter Pins
No. Function Label
1
+IN
+
Primary
Control
2
PC
3
4
5
Parallel
–IN
PR
–
–OUT
–
Secondary
Control
6
7
SC
+
+OUT
DIMENSION L
PIN SHORT – .55±.ꢀ05 ꢁ01.ꢀ±.±ꢂ3
PIN LONG–– .6±±.ꢀ05 ꢁ06.ꢀ±.±ꢂ3
PIN EXTRA LONG–––- .70±.ꢀ05 ꢁ0ꢂ.ꢀ±.±ꢂ3
NOTES:
1. MATERIAL:
BASE: 6000 SERIES ALUMINUM
COVER: LCP, ALUMINUM 3003 H14
PINS:
PINS:
RoHS PINS GOLD PLATE 30 MICRO INCH MIN; NON-RoHS
TIN/LEAD 90/10 BRIGHT
2. DIMENSIONS AND VALUES IN BRACKETS ARE METRIC
3. MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING
BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD
OF THE APPLICATION RANGES FROM DIRECT CONTACT ꢀZEROꢁ, TO THE
MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACKꢂUP
AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION
Figure 13 — Module outline
ALL MARKINGS
THIS SURFACE
0.062 0.010
1,57 0,25
PCB THICKNESS
0.800*
20,32
INBOARD
SOLDER
MOUNT
ONBOARD
SOLDER
MOUNT
0.525*
13,34
PLATED
THRU HOLE
DIA
0.275*
6,99
SHORT PIN STYLE
0.094 0.003
LONG PIN STYLE
ALUMINUM
BASEPLATE
0.094 0.003
(7X)
0.145*
3,68
2,39 0,08
2,39 0,08
PINS STYLES
SOLDER:TIN/LEAD PLATED
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
0.133
3,38
1
7
2
3
4
5
1.734**
44,04
2.000*
50,80
For Soldering Methods and Procedures
Please refer to:
THE MAXI, MINI, MICRO Design Guide.
6
Unless otherwise specified,
dimensions are in inches
mm
0.06
1,5
R
(4X)
0.53
13,5
0.45
11,5
.400*
10,16
0.003
*DENOTES TOL =
Decimals
Tol.
Angles
0,08
1.090**
27,69
0.XX
±0.01
±0.25
**PCB WINDOW
±1°
0.XXX
±0.005
±0.127
Figure 14 — PCB mounting specifications
28V Wide Micro Family
Page 11 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/dc-dc-converters-board-mount/high-density-dc-dc-converters for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating
to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual
property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
28V Wide Micro Family
Page 12 of 12
Rev 2.6
06/2017
vicorpower.com
800 927.9474
V28C5C50BS 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
V28C5C50BS2 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, PACKAGE-7 | 获取价格 | |
V28C5C50BS3 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, PACKAGE-7 | 获取价格 | |
V28C5H50B3 | VICOR | CONVERTER MOD DC/DC 5V 50W | 获取价格 | |
V28C5H50BF | VICOR | CONVERTER MOD DC/DC 5V 50W | 获取价格 | |
V28C5H50BF2 | VICOR | CONVERTER MOD DC/DC 5V 50W | 获取价格 | |
V28C5H50BF3 | VICOR | CONVERTER MOD DC/DC 5V 50W | 获取价格 | |
V28C5H50BG | VICOR | Maxi、Mini、Micro DC-DC 转换器 | 获取价格 | |
V28C5H50BG2 | VICOR | CONVERTER MOD DC/DC 5V 50W | 获取价格 | |
V28C5H50BG3 | VICOR | CONVERTER MOD DC/DC 5V 50W | 获取价格 | |
V28C5H50BL | VICOR | 28V Wide Input Micro Family DC-DC Converter Module | 获取价格 |
V28C5C50BS 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6