Micro Family  
300V Input  
Actual size:  
2.28 x 1.45 x 0.5 in  
57,9 x 36,8 x 12,7 mm  
S
®
C
NRTL US  
C
US  
DC-DC Converter Module  
Features  
Applications  
DC input range: 180 - 375 V  
Isolated output  
Off-line systems with auto-ranging or PFC front ends, industrial and process control,  
distributed power, medical, ATE, communications, defense, aerospace.  
Input surge withstand: 400 V for 100 ms  
DC output: 3.3 – 48 V  
For details on proper operation please refer to:  
Programmable output: 10 to 110%  
Regulation: 0.5% no load to full load  
Efficiency: Up to 90%  
Design Guide & Applications Manual for Maxi, Mini, Micro Family.  
Maximum operating temp: 100°C, full load  
Power density: up to 90 W per cubic inch  
Height above board: 0.43 in. (10,9 mm)  
Parallelable, with N+M fault tolerance  
Low noise ZCS/ZVS architecture  
Absolute Maximum Ratings  
RoHS Compliant (with F or G pin option)  
Parameter  
Rating  
Unit  
Vdc  
Vdc  
Vdc  
Vdc  
Notes  
+In to –In voltage  
PC to –In voltage  
PR to –In voltage  
SC to -Out voltage  
-0.5 to +410  
-0.5 to +7.0  
-0.5 to +7.0  
-0.5 to +1.5  
Product Overview  
These DC-DC converter modules use  
advanced power processing, control and  
packaging technologies to provide the  
performance, flexibility, reliability and cost  
effectiveness of a mature power component.  
High frequency ZCS/ZVS switching  
provides high power density with low  
noise and high efficiency.  
Isolation voltage  
in to out  
3000  
1500  
Vrms  
Vrms  
Test voltage  
Test voltage  
Test voltage  
M-Grade  
in to base  
out to base  
500  
Vrms  
Operating Temperature  
Storage Temperature  
Pin soldering temperature  
Pin soldering temperature  
Mounting torque  
-55 to +100  
-65 to +125  
500 (260)  
750 (390)  
5 (0.57)  
°C  
°C  
M-Grade  
°F (°C)  
°F (°C)  
in-lbs (N-m)  
<5 sec; wave solder  
<7 sec; hand solder  
6 each  
Part Numbering  
e.g. V300C12T150BL2  
V300C  
B
Baseplate  
Blank: Slotted  
2: Threaded  
Product Grade Temperatures (°C)  
Output Power  
Pin Style  
Finish  
Output Voltage  
2 = 2 V  
3 V 3 = 3.3 V  
5 = 5 V  
Grade  
Operating  
Storage  
Vout  
2 V  
Pout  
50 W  
Blank: Short  
Tin/Lead  
E
C
T
H
M
=
=
=
=
=
-
10 to +100  
20 to +100  
40 to +100  
40 to +100  
55 to +100  
-
-
-
-
-
20 to +125  
40 to +125  
40 to +125  
55 to +125  
65 to +125  
L: Long  
Tin/Lead  
3: Through-hole  
-
-
-
-
3.3 V  
5 V  
75 W, 50 W  
100 W, 50 W  
100 W  
S: Short ModuMate Gold  
N: Long ModuMate  
F: Short RoHS  
Gold  
Gold  
Gold  
8 = 8 V  
8 V  
12 = 12 V  
15 = 15 V  
24 = 24 V  
28 = 28 V  
36 = 36 V  
48 = 48 V  
12 V  
15 V  
24 V  
28 V  
36 V  
48 V  
150 W, 75W  
150 W, 75 W  
150 W, 75 W  
150 W, 75 W  
150 W, 75 W  
150 W, 75 W  
G: Long RoHS  
300V Micro Family  
Page 1 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
MODULE FAMILY ELECTRICAL CHARACTERISTICS  
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,  
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.  
MODULE INPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
375  
Unit  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
mA  
Notes  
Operating input voltage  
Input surge withstand  
Undervoltage turn-on  
Undervoltage turn-off  
Overvoltage turn-off/on  
Disabled input current  
180  
300  
400  
<100 ms  
174.6  
152.8  
178.2  
147.4  
Not included  
PC pin low  
1.2  
MODULE OUTPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
1
Unit  
% Vout nom.  
%
Notes  
Output voltage setpoint  
Line regulation  
Nominal input; full load; 25°C  
Low line to high line; full load  
Over operating temperature range  
10 to 100% of full load  
0.02  
0.002  
2
0.20  
0.005  
5
Temperature regulation  
Power sharing accuracy  
% / °C  
%
Of nominal output voltage. For trimming below 90%  
of nominal, a minimum load of 10% of maximum  
rated power may be required.  
10  
110  
Programming range  
%
+Out to –Out — Absolute Maximum Ratings  
2 V  
3.3 V  
5 V  
-0.5 to 3.1  
-0.5 to 4.7  
-0.5 to 7.0  
-0.5 to 10.9  
-0.5 to 16.1  
-0.5 to 20.0  
-0.5 to 31.7  
-0.5 to 36.9  
-0.5 to 47.1  
-0.5 to 62.9  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
8 V  
12 V  
15 V  
24 V  
28 V  
36 V  
48 V  
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,  
contact Vicor applications engineering at 800-927-9474.  
THERMAL RESISTANCE AND CAPACITY  
Parameter  
Min  
Typ  
0.24  
0.21  
10.9  
2.8  
Max  
Unit  
°C/Watt  
Baseplate to sink; flat, greased surface  
Baseplate to sink; thermal pad (P/N 20265)  
Baseplate to ambient  
°C/Watt  
°C/Watt  
Baseplate to ambient; 1000 LFM  
Thermal capacity  
°C/Watt  
48  
Watt-sec/°C  
300V Micro Family  
Page 2 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
MODULE FAMILY ELECTRICAL CHARACTERISTICS (CONT.)  
MODULE CONTROL SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
PRIMARY SIDE (PC = Primary Control; PR = Parallel)  
PC bias voltage  
current limit  
5.50  
1.5  
5.75  
2.1  
6.00  
3.0  
Vdc  
mA  
PC current = 1.0 mA  
PC voltage = 5.5 V  
PC module disable  
PC module enable delay  
PC module alarm  
2.3  
2.6  
4
2.9  
7
Vdc  
ms  
Switch must be able to sink 4 mA. See Fig. 2  
0.5  
1.1  
6.1  
Vavg  
MΩ  
UV, OV, OT, module fault. See Figs. 3 and 5  
See Fig. 3, converter off or fault mode  
PR load >30 Ω, <30 pF  
PC resistance  
0.9  
5.7  
1.0  
5.9  
PR emitter amplitude  
PR emitter current  
PR receiver impedance  
PR receiver threshold  
PR drive capability  
Volts  
150  
375  
2.4  
mA  
500  
2.5  
625  
2.6  
12  
Ω
Volts  
25°C  
Minimum pulse width: 20 ns  
Without PR buffer amplifier  
modules  
SECONDARY SIDE (SC = Secondary Control)  
SC bandgap voltage  
1.21  
1.23  
1000  
0.033  
1.25  
Vdc  
Ω
Referenced to –Sense  
SC resistance  
990  
1010  
SC capacitance  
µF  
SC module alarm  
0
Vdc  
With open trim; referenced to –Sense. See Fig. 7  
MODULE GENERAL SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Isolation test voltage (in to out)*  
Isolation test voltage (in to base)*  
Isolation test voltage (out to base)*  
3000  
1500  
500  
Vrms  
Vrms  
Vrms  
Complies with reinforced insulation requirements  
Complies with basic insulation requirements  
Complies with operational insulation requirements  
Isolation resistance  
10  
MΩ  
in to out, in to baseplate, out to baseplate  
1.9  
(52.8)  
2.1  
(59.3)  
2.3  
(65.8)  
ounces  
Weight (E, C, T grade)  
(grams)  
2.1  
(58.7)  
2.3  
(65.2)  
2.5  
(71.7)  
ounces  
(grams)  
Weight (H, M grade)  
Temperature limiting  
Agency approvals  
100  
115  
°C  
See Figs. 3 and 5. Do not operate coverter >100C.  
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.  
With appropriate fuse in series with the +Input  
cURus, cTÜVus, CE  
* Isolation test voltage, 1 minute or less.  
Note:  
Specifications are subject to change without notice.  
300V Micro Family  
Page 3 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS  
2 Vout, 50 W (e.g. V300C2C50BL)  
Parameter  
Efficiency  
Min  
72.5  
Typ  
73.9  
120  
2.8  
3.5  
0.02  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
150  
2.9  
4.5  
0.2  
25  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
2.7  
No load to full load; nominal input  
0
25.5  
17.5  
Current limit  
Short circuit current  
28.8  
28.8  
33.8  
33.8  
Output voltage 95% of nominal  
Output voltage <250 mV  
3.3 Vout, 75 W (e.g. V300C3V3C75BL)  
Parameter  
Efficiency  
Min  
77.6  
Typ  
79.8  
120  
4.3  
3.4  
0.06  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20 MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
150  
4.46  
5.1  
4.14  
0.4  
No load to full load; nominal input  
0
23.2  
15.9  
22.7  
31.8  
31.8  
Current limit  
Short circuit current  
26.2  
26.2  
Output voltage 95% of nominal  
Output voltage <250 mV  
3.3 Vout, 50 W (e.g. V300C3V3C50BL)  
Parameter  
Efficiency  
Min  
76.7  
Typ  
77.7  
160  
4.3  
2.7  
0.02  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
200  
4.46  
4
4.14  
0.2  
No load to full load; nominal input  
0
15.5  
10.6  
15.15  
20.6  
20.6  
Current limit  
Short circuit current  
17.5  
17.5  
Output voltage 95% of nominal  
Output voltage <250 mV  
5 Vout, 100 W (e.g. V300C5C100BL)  
Parameter  
Efficiency  
Min  
80.5  
Typ  
81.5  
105  
6.25  
4.4  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20 MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
132  
6.47  
6.6  
0.4  
20  
6.03  
0.1  
No load to full load; nominal input  
0
20.4  
14  
Current limit  
Short circuit current  
23  
23  
27  
27  
Output voltage 95% of nominal  
Output voltage <250 mV  
5 Vout, 50 W (e.g. V300C5C50BL)  
Parameter  
Efficiency  
Min  
79.5  
Typ  
81  
Max  
Unit  
%
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20 MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
72  
6.25  
2.8  
90  
6.47  
4
0.2  
10  
mV  
6.03  
Volts  
Watts  
%
Amps  
Amps  
Amps  
0.02  
No load to full load; nominal input  
0
10.2  
7
Current limit  
Short circuit current  
11.5  
11.5  
13.5  
13.5  
Output voltage 95% of nominal  
Output voltage <250 mV  
300V Micro Family  
Page 4 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)  
8 Vout, 100 W (e.g.V300C8C100BL)  
Parameter  
Efficiency  
Min  
80.2  
Typ  
82.3  
220  
9.7  
3.8  
0.02  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
275  
10.1  
4.4  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
9.36  
0.2  
No load to full load; nominal input  
0
12.7  
8.75  
12.5  
16.9  
16.9  
Current limit  
Short circuit current  
14.4  
14.4  
Output voltage 95% of nominal  
Output voltage <250 mV  
12 Vout, 150 W (e.g. V300C12C150BL)  
Parameter  
Efficiency  
Min  
84.3  
Typ  
85.3  
170  
14.3  
5
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20 MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
213  
14.9  
7.5  
13.7  
0.02  
0.2  
No load to full load; nominal input  
0
12.7  
8.75  
12.5  
16.3  
16.3  
Current limit  
Short circuit current  
14.4  
14.4  
Output voltage 95% of nominal  
Output voltage <250 mV  
12 Vout, 75 W (e.g. V300C12C75BL)  
Parameter  
Efficiency  
Min  
83.5  
Typ  
85  
Max  
Unit  
%
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20 MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
200  
14.3  
4
250  
14.9  
5.3  
mV  
13.7  
Volts  
Watts  
%
Amps  
Amps  
Amps  
0.02  
0.2  
No load to full load; nominal input  
0
6.37  
4.37  
6.25  
8.44  
8.44  
Current limit  
Short circuit current  
7.19  
7.19  
Output voltage 95% of nominal  
Output voltage <250 mV  
15 Vout, 150 W (e.g. V300C15C150BL)  
Parameter  
Efficiency  
Min  
85.5  
Typ  
86.5  
150  
17.8  
7
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20 MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
188  
18.5  
10.5  
0.2  
10  
17.1  
0.02  
No load to full load; nominal input  
0
10.2  
3
Current limit  
Short circuit current  
11.5  
11.5  
13  
13  
Output voltage 95% of nominal  
Output voltage <250 mV  
15 Vout, 75 W (e.g. V300C15C75BL)  
Parameter  
Efficiency  
Min  
84.2  
Typ  
85.2  
150  
17.8  
3
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
188  
18.5  
5
0.2  
5
17.1  
0.02  
No load to full load; nominal input  
0
5.1  
3.5  
Current limit  
Short circuit current  
5.75  
5.75  
6.75  
6.75  
Output voltage 95% of nominal  
Output voltage <250 mV  
300V Micro Family  
Page 5 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)  
24 Vout, 150 W (e.g. V300C24C150BL)  
Parameter  
Efficiency  
Min  
85.5  
Typ  
86.5  
150  
28.1  
4.9  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
188  
29.1  
7.4  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
27.1  
0.02  
0.2  
No load to full load; nominal input  
0
6.37  
3.5  
6.25  
8.44  
8.15  
Current limit  
Short circuit current  
7.19  
7.19  
Output voltage 95% of nominal  
Output voltage <250 mV  
24 Vout, 75 W (e.g. V300C24C75BL)  
Parameter  
Efficiency  
Min  
84.7  
Typ  
86.4  
100  
28.1  
2.1  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
125  
29.1  
3.8  
27.1  
0.02  
0.2  
No load to full load; nominal input  
0
3.19  
2.19  
3.13  
4.23  
4.23  
Current limit  
Short circuit current  
3.6  
3.6  
Output voltage 95% of nominal  
Output voltage <250 mV  
28 Vout, 150 W (e.g. V300C28C150BL)  
Parameter  
Efficiency  
Min  
85.5  
Typ  
86.5  
180  
32.7  
4.6  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20 MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
225  
33.9  
6.9  
31.5  
0.02  
0.3  
No load to full load; nominal input  
0
5.46  
3.75  
5.36  
6.97  
6.97  
Current limit  
Short circuit current  
6.16  
6.16  
Output voltage 95% of nominal  
Output voltage <250 mV  
28 Vout, 75 W (e.g. V300C28C75BL)  
Parameter  
Efficiency  
Min  
86  
Typ  
87.3  
65  
32.7  
4.3  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
82  
33.9  
5.5  
31.5  
0.02  
0.2  
No load to full load; nominal input  
0
2.73  
1.87  
2.68  
3.62  
3.62  
Current limit  
Short circuit current  
3.08  
3.08  
Output voltage 95% of nominal  
Output voltage <250 mV  
36 Vout, 150 W (e.g. V300C36C150BL)  
Parameter  
Efficiency  
Min  
85.5  
Typ  
87  
Max  
Unit  
%
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
300  
41.9  
4.8  
375  
43.4  
5.6  
mV  
40.4  
Volts  
Watts  
%
Amps  
Amps  
Amps  
0.02  
0.2  
No load to full load; nominal input  
0
4.25  
2.91  
4.17  
5.63  
5.63  
Current limit  
Short circuit current  
4.8  
4.8  
Output voltage 95% of nominal  
Output voltage <250 mV  
300V Micro Family  
Page 6 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)  
36 Vout, 75 W (e.g. V300C36C75BL)  
Parameter  
Efficiency  
Min  
82.5  
Typ  
85.6  
99  
41.9  
4
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
124  
43.4  
6.2  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
40.4  
0
0.2  
No load to full load; nominal input  
0
2.12  
1.45  
2.08  
2.81  
2.81  
Current limit  
Short circuit current  
2.39  
2.39  
Output voltage 95% of nominal  
Output voltage <250 mV  
48 Vout, 150 W (e.g. V300C48C150BL)  
Parameter  
Efficiency  
Min  
86.5  
Typ  
88.2  
55  
55.7  
3.5  
Max  
Unit  
%
mV  
Volts  
Watts  
%
Amps  
Amps  
Amps  
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20 MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
69  
57.7  
6.1  
53.7  
0.02  
0.2  
No load to full load; nominal input  
0
3.19  
2.19  
3.13  
4.22  
4.22  
Current limit  
Short circuit current  
3.6  
3.6  
Output voltage 95% of nominal  
Output voltage <250 mV  
48 Vout, 75 W (e.g. V300C48C75BL)  
Parameter  
Efficiency  
Min  
83  
Typ  
86  
Max  
Unit  
%
Notes  
Nominal input; full load; 25°C  
p-p; Nominal input; full load; 20MHz bandwidth  
25°C; recycle input voltage or PC to restart (>100 ms off)  
No load  
Ripple and noise  
Output OVP setpoint  
Dissipation, standby  
Load regulation  
Load current  
400  
55.7  
3.2  
500  
57.7  
4.5  
mV  
53.7  
Volts  
Watts  
%
Amps  
Amps  
Amps  
0.02  
0.2  
No load to full load; nominal input  
0
1.59  
1.09  
1.56  
2.11  
2.11  
Current limit  
Short circuit current  
1.79  
1.79  
Output voltage 95% of nominal  
Output voltage <250 mV  
300V Micro Family  
Page 7 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
BASIC MODULE OPERATION  
C2*  
4.7nF  
C4*  
4.7nF  
+IN  
PC  
PR  
+OUT  
SC  
F1*  
C1*  
0.2µF  
–IN  
–OUT  
C3*  
4.7nF  
C5*  
4.7nF  
For C1 – C5, keep leads and connections short.  
Figure 1 Basic module operation requires fusing, grounding, bypassing capacitors.  
* See Maxi, Mini, Micro Design Guide.  
Comprehensive Online Application Information  
The Design Guide and Applications Manual includes:  
• Application circuits  
• Design requirements  
• EMC considerations  
• Current sharing in power arrays  
• Thermal performance information  
• Recommended soldering methods  
• Accessory modules – filtering, rectification, front-ends  
• Mounting options  
...and more.  
CLICKꢀHERE TOꢀVIEW  
DESIGN GUIDE  
Also at vicorpower.com  
• PowerBench online configurators  
• Over 20 Application Notes  
• Online calculators – thermal, trimming, hold-up  
• PDF data sheets for ALL Vicor products  
300V Micro Family  
Page 8 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
PRIMARY CONTROL - PC PIN  
Module Enable/Disable  
Module Alarm  
The module may be disabled by pulling PC to 0 V (2.3 V  
max) with respect to the –Input. This may be done with an  
open collector transistor, relay, or optocoupler. Converters  
may be disabled with a single transistor or relay either directly  
or via “OR’ing” diodes for 2 or more converters. See Figure 2.  
The module contains “watchdog” circuitry which monitors  
input voltage, operating temperature and internal operating  
parameters. In the event that any of these parameters are  
outside of their allowable operating range, the module will  
shut down and PC will go low. PC will periodically go high  
and the module will check to see if the fault (as an example,  
Input Undervoltage) has cleared. If the fault has not been  
cleared, PC will go low again and the cycle will restart. The  
SC pin will go low in the event of a fault and return to its nor-  
mal state after the fault has been cleared. See Figures 3 and 5.  
Primary Auxiliary Supply  
During normal operation only, the PC Pin can source 5.7 V @  
1.5 mA. In the example shown in Figure 4, PC powers a mod-  
ule enabled LED.  
Input Undervoltage  
[a]  
Input Overvoltage  
Over Temperature  
Module Faults  
+IN  
+OUT  
SC  
+IN  
PC  
Auto  
Restart  
SW1  
50 Ω  
PC  
PR  
2-20 ms typ.  
f(VIN)  
1 K  
6 K  
SW2  
SW3  
5.7 Vdc  
PR  
1 M  
(0-3 mA)  
Disable  
1.23  
Vdc  
–IN  
–OUT  
SW1, 2, & 3 shown  
in "Fault" position  
–IN  
Disable = PC < 2.3 V  
[a] Not applicable for 300 Vdc Input family  
Figure 2 Module enable/disable.  
Figure 3 PC/SC module alarm logic.  
+IN  
PC  
Fault  
40 µs typ.  
5.7 V  
PC  
4 kΩ  
"Module  
Enabled"  
PR  
1.23 V  
2-20 ms typ.  
SC  
–IN  
Figure 4 LED on-state indicator.  
Figure 5 PC/SC module alarm timing.  
+IN  
+OUT  
Comparator  
Optocoupler  
PC  
SC  
Alarm  
PR  
4 k  
1.00 V  
–IN  
–OUT  
Figure 6 Isolated on-state indicator.  
Figure 7 Secondary side on-state indicator.  
300V Micro Family  
Page 9 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
SECONDARY CONTROL - SC PIN  
PARALLEL BUS - PR PIN  
Output Voltage Programming  
Parallel Operation  
The output voltage of the converter can be adjusted or  
programmed via fixed resistors, potentiometers or voltage  
DACs. See Figure 8.  
The PR pin supports paralleling for increased power with N+1  
(N+M) redundancy. Modules of the same input voltage, output  
voltage, and power level will current share if all PR pins are  
suitably interfaced.  
Compatible interface architectures include the following:  
AC coupled single-wire interface. All PR pins are connected  
to a single communication bus through 0.001 µF (500 V)  
capacitors. This interface supports current sharing and is fault  
tolerant except for the communication bus. Up to three  
converters may be paralleled by this method. See Figure 9.  
+OUT  
RU  
Trim Up  
Error  
Load  
SC  
Amp  
RD  
Trim Down  
1 kΩ  
0.033 μF  
Transformer coupled interface. For paralleling four or more  
converters a transformer coupled interface is required. See  
Figure 10.  
–OUT  
1.23 V  
For details on parallel operation please refer to the  
Design Guide & Applications Manual for Maxi, Mini, Micro Family.  
1,000 Vout  
Vnom – Vout  
RD (ohms) =  
RU (ohms) =  
4.7 nF  
+
+IN  
PC  
PR  
–IN  
1,000 (Vout –1.23) Vnom  
1.23 (Vout – Vnom)  
– 1,000  
0.2 µF  
Z1*  
Module 1  
Module 2  
0.001 µF  
Figure 8 Output voltage trim down and trim up circuit.  
4.7 nF  
4.7 nF  
0.2 µF  
Low inductance  
ground plane  
or bus  
Trim Down  
+IN  
PC  
PR  
–IN  
1. This converter is not a constant power device – it has a  
constant current limit. Hence, available output power is  
reduced by the same percentage that output voltage is  
trimmed down. Do not exceed maximum rated output current.  
0.001 µF  
Z1*  
2. The trim down resistor must be connected between the SC  
and pins. Do not bypass the SC pin directly with a  
capacitor.  
4.7 nF  
Parallel  
Bus  
Figure 9 AC coupled single-wire interface.  
* See Maxi, Mini, Micro Design Guide.  
Trim Up  
1. The converter is rated for a maximum delivered power. To  
ensure that maximum rated power is not exceeded, reduce  
maximum output current by the same percentage increase in  
output voltage.  
4.7 nF  
+
+IN  
PC  
PR  
–IN  
0.2 µF  
Z1*  
Module 1  
Module 2  
T1  
2. The trim up resistor must be connected between the SC  
and pins. Do not bypass the SC pin directly with a  
capacitor.  
4.7 nF  
4.7 nF  
3. Do not trim the converter above maximum trim range  
(typically +10%) or the output over voltage protection  
circuitry may be activated.  
+IN  
PC  
PR  
–IN  
0.2 µF  
Z1*  
T2  
Trim resistor values calculated automatically:  
On-line calculators for trim resistor values are available on the  
vicor website at:  
asp.vicorpower.com/calculators/calculators.asp?calc=1  
Resistor values can be calculated for fixed trim up, fixed trim  
down and for variable trim up or down.  
4.7 nF  
Parallel  
Bus  
Figure 10 Transformer-coupled interface.  
300V Micro Family  
Page 10 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
PARALLEL BUS /  
VOLTAGE DROP COMPENSATION  
+OUT  
SC  
• The +Out and –Out  
power buses should be  
designed to minimize  
and balance parasitic  
impedance from each  
module output to the  
load.  
Plane  
Module #1  
Designated  
Master  
+Out  
SC  
+S  
R7 21.0 k  
C3  
R4  
–OUT  
R9  
R1  
R8  
C2  
0.22 µF  
4.02 k  
R3  
U2  
R5  
U1  
R2  
2.55 k  
TLV431  
Vcc  
1.00 k  
R6  
1.65 k  
R Load  
R11  
36.5 k  
C1  
470 pF  
+OUT  
SC  
200mV  
+
+
R10  
1.24 k  
PS2701  
U3  
LM10  
• At the discretion of the  
power system designer,  
a subset of all modules  
within an array may be  
configured as slaves by  
connecting SC to –Out.  
Gnd  
L
O
A
D
Module #2  
trimmed  
–S  
–Out  
down 2 %  
See Component Selection section below.  
–OUT  
• This module is designed for point of load regulation, where remote sensing  
is not required. Active voltage drop compensator, as shown here, may be  
used in applications with significant distribution losses.  
+OUT  
SC  
• Do not use output  
OR’ing diodes with  
MicroMods.  
Module #3  
trimmed  
Please consult with the Micro Family Isolated Remote Sense Application Note  
for additional information.  
Ground  
Plane  
down 4 %  
–OUT  
Figure 11 N+1 module array output connections.  
Figure 12 Voltage drop compensation.  
PINꢀSTYLES*  
Designator  
Description  
Short  
Finish  
Tin/Lead  
Tin/Lead  
Gold  
Notes  
(None)  
Requires in-board, mounting  
L
S
N
F
Long  
On-board mounting for 0.065" boards  
Short ModuMate  
Long ModuMate  
Short RoHS  
Long RoHS  
SurfMate or in-board socket mounting  
Gold  
On-board socket mounting  
Gold  
Select for RoHS compliant in-board solder, socket, or SurfMate mounting  
Select for RoHS compliant on-board solder or socket mounting  
G
Gold  
*
Pin style designator follows the “B” after the output power and precedes the baseplate designator.  
Ex. V300C12T150BN2 — Long ModuMate Pins  
300V Micro Family  
Page 11 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
MECHANICAL DRAWINGS  
Converter Pins  
No. Function Label  
1
+In  
+
Primary  
Control  
2
PC  
3
4
5
Parallel  
–In  
PR  
–Out  
Secondary  
Control  
6
7
SC  
+
+Out  
Figure 13 Module outline  
ALL MARKINGS  
THIS SURFACE  
0.062 0.010  
1,57 0,25  
PCB THICKNESS  
0.800*  
20,32  
INBOARD  
SOLDER  
MOUNT  
ONBOARD  
SOLDER  
MOUNT  
0.525*  
13,34  
PLATED  
THRU HOLE  
DIA  
0.275*  
6,99  
SHORT PIN STYLE  
0.094 0.003  
LONG PIN STYLE  
ALUMINUM  
BASEPLATE  
0.094 0.003  
(7X)  
0.145*  
3,68  
2,39 0,08  
2,39 0,08  
PINS STYLES  
0.133  
3,38  
SOLDER:TIN/LEAD PLATED  
MODUMATE: GOLD PLATED COPPER  
RoHS: GOLD PLATED COPPER  
1
7
2
3
4
5
1.734**  
44,04  
2.000*  
50,80  
FOR SOLDERING METHODS AND PROCE-  
DURES PLEASE REFER TO THE MAXI, MINI,  
MICRO DESIGN GUIDE.  
6
0.06  
1,5  
Unless otherwise specified,  
dimensions are in inches  
mm  
R
(4X)  
0.53  
13,5  
0.45  
11,5  
.400*  
10,16  
0.003  
0,08  
*DENOTES TOL =  
**PCB WINDOW  
Decimals  
Tol.  
Angles  
1.090**  
27,69  
0.XX  
0.01  
0.25  
0.005  
0.127  
1°  
0.XXX  
Figure 14 PCB mounting specifications  
300V Micro Family  
Page 12 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  
300V Input  
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and  
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom  
power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no  
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make  
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and  
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are  
used to the extent Vicor deems necessary to support Vicors product warranty. Except where mandated by government requirements, testing of all  
parameters of each product is not necessarily performed.  
Specifications are subject to change without notice.  
Vicor’s Standard Terms and Conditions  
All sales are subject to Vicors Standard Terms and Conditions of Sale, which are available on Vicors webpage or upon request.  
Product Warranty  
In Vicors standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the  
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment  
and is not transferable.  
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS  
ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH  
RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR  
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.  
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable  
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes  
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and  
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operat-  
ing safeguards.  
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact  
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be  
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the  
product was defective within the terms of this warranty.  
Life Support Policy  
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS  
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support  
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform  
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the  
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the  
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products  
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the prod-  
ucts described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is  
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
Fax: 978-475-6715  
email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
300V Micro Family  
Page 13 of 13  
Rev 9.0  
vicorpower.com  
800 735.6200  
4/2013  

相关型号:

V300C8C100BL2

CONVERTER MOD DC/DC 8V 100W
VICOR

V300C8C100BL3

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-7
VICOR

V300C8C100BN

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-7
VICOR

V300C8C100BN2

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-7
VICOR

V300C8C100BN3

CONVERTER MOD DC/DC 8V 100W
VICOR

V300C8C100BS

CONVERTER MOD DC/DC 8V 100W
VICOR

V300C8C100BS2

CONVERTER MOD DC/DC 8V 100W
VICOR

V300C8C100BS3

DC DC CONVERTER 8V 100W
VICOR

V300C8E100B

CONVERTER MOD DC/DC 8V 100W
VICOR

V300C8E100B2

CONVERTER MOD DC/DC 8V 100W
VICOR

V300C8E100B3

CONVERTER MOD DC/DC 8V 100W
VICOR

V300C8E100BF

DC DC CONVERTER 8V 100W
VICOR