V72C36E150N2 [VICOR]
DC-DC Regulated Power Supply Module, 1 Output, 204.7W, Hybrid, MODULE-7;型号: | V72C36E150N2 |
厂家: | VICOR CORPORATION |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 204.7W, Hybrid, MODULE-7 |
文件: | 总11页 (文件大小:619K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Data Sheet
72V Input Micro Family
Features
• DC input range: 43 – 110 V (continuous)
• Isolated output
DC-DC Converter Module
• Encapsulated circuitry for shock and
vibration resistance
• Extended temperature range
(–55 to +100 °C)
• Input surge withstand: 150 V for 100 ms
• DC output: 3.3 – 48 V
• Programmable output: 10 to 110%
• Regulation: 0.2% no load to full load
• Efficiency: Up to 87%
•
Maximum operating temp: 100 °C, full load
• Power density: up to 90 W per cubic inch
• Height above board: 0.43 in. (10,9 mm)
• Parallelable, with N+M fault tolerance
• Low noise ZCS/ZVS architecture
Shown actual size:
2.28 x 1.45 x 0.5 in
57,9 x 36,8 x 12,7 mm
• RoHS Compliant (with F or G pin option)
Product Overview
Absolute Maximum Ratings
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching
provides high power density with low
noise and high efficiency.
Parameter
Rating
–0.5 to +155
–0.5 to +7.0
–0.5 to +7.0
–0.5 to +1.5
1.0
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Notes
+In to –In voltage
PC to –In voltage
PR to –In voltage
SC to –Out voltage
–Sense to –Out voltage
Isolation voltage
in to out
Applications
3000
1500
Vrms
Vrms
Test voltage
Test voltage
Test voltage
M-Grade
Railway/Transportation system applications
including communications systems,
information display, lighting, control
systems, ticket machines, passenger
entertainment, public address systems, door
control, industrial power systems and
power generation systems.
in to base
out to base
500
Vrms
Operating Temperature
Storage Temperature
–55 to +100
–65 to +125
500 (260)
750 (390)
5 (0.57)
°C
°C
M-Grade
°F (°C)
°F (°C)
in-lbs (N-m)
<5 sec; wave solder
<7 sec; hand solder
6 each
Pin soldering temperature
For details on proper operation please refer
to the Design Guide & Applications
Manual for Maxi, Mini, Micro Family.
Mounting torque
Part Numbering
e.g. V72C15C150BL
V72C
B
Baseplate
Blank: Slotted
2: Threaded
Product Grade Temperatures (°C)
Output Power
Vout Pout
3.3 V 75 W
Pin Style
Finish
Tin/Lead
Tin/Lead
Output Voltage
3V3 = 3.3 V
5 = 5 V
8 = 8 V
12 = 12 V
15 = 15 V
Grade
Operating
Storage
Blank: Short
E
C
T
H
=
=
=
=
=
-
10 to +100
20 to +100
40 to +100
40 to +100
55 to +100
-
-
-
-
-
20 to +125
40 to +125
40 to +125
55 to +125
65 to +125
L: Long
3: Through-hole
-
-
-
-
5 V
100 W
100 W
150 W
150 W
150W
150W
150W
150W
S: Short ModuMate Gold
8 V
N: Long ModuMate
F: Short RoHS
Gold
Gold
Gold
12 V
15 V
24 V
28 V
36 V
48 V
M
G: Long RoHS
24 = 24 V
28 = 28 V
36 = 36 V
48 = 48 V
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 1 of 11
Set your site on VICOR at vicorpower.com
MODULE FAMILY ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
110
150
42.6
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
mA
Notes
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
43
72
EN50155
<100 ms
41.7
36.5
35.2
111
115.5
121
1.5
PC pin low
MODULE OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Max
1
Unit
% Vout nom.
%
Notes
Output voltage setpoint
Line regulation
Nominal input; full load; 25 °C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
0.02
0.002
2
0.20
0.005
5
Temperature regulation
Power sharing accuracy
% / °C
%
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Programming range
10
110
%
+Out to –Out — Absolute Maximum Ratings
3.3 V
5 V
8 V
12 V
15 V
24 V
28 V
36 V
48 V
-0.5 to 4.7
-0.5 to 7.0
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications
engineering at 800-927-9474.
THERMAL RESISTANCE AND CAPACITY
Parameter
Min
Typ
0.24
0.21
10.9
2.8
Max
Unit
°C/Watt
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
°C/Watt
°C/Watt
Baseplate to ambient; 1000 LFM
Thermal capacity
°C/Watt
48
Watt-sec/°C
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 2 of 11
Set your site on VICOR at vicorpower.com
MODULE FAMILY ELECTRICAL CHARACTERISTICS (CONT.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
PRIMARY SIDE (PC = Primary Control; PR = Parallel)
PC bias voltage
5.50
1.5
5.75
2.1
6.00
3.0
Vdc
mA
PC current = 1.0 mA
PC voltage = 5.5 V
current limit
PC module disable
PC module enable delay
PC module alarm
2.3
2.6
4
2.9
7
Vdc
ms
Switch must be able to sink ≥4 mA. See Fig. 2
0.5
1.1
6.1
Vavg
MΩ
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30 Ω, <30 pF
PC resistance
0.9
5.7
150
375
2.4
1.0
5.9
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Volts
mA
500
2.5
625
2.6
12
Ω
Volts
25 °C
Minimum pulse width: 20 ns
Without PR buffer amplifier
modules
SECONDARY SIDE (SC = Secondary Control)
SC bandgap voltage
1.21
1.23
1000
0.033
1.25
Vdc
Ω
Referenced to –Sense
SC resistance
990
1010
SC capacitance
µF
SC module alarm
0
Vdc
With open trim; referenced to –Sense. See Fig. 7
MODULE GENERAL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Isolation test voltage (in to out)*
Isolation test voltage (in to base)*
Isolation test voltage (out to base)*
3000
1500
500
Vrms
Vrms
Vrms
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
Isolation resistance
10
MΩ
in to out, in to baseplate, out to baseplate
1.9
(52.8)
2.1
(59.3)
2.3
(65.8)
ounces
Weight (E, C, T grade)
(grams)
2.1
(58.7)
2.3
(65.2)
2.5
(71.7)
ounces
(grams)
Weight (H, M grade)
Temperature limiting
Agency approvals
100
115
°C
See Figs. 3 and 5. Do not operate coverter >100C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
cURus, cTÜVus, CE
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 3 of 11
Set your site on VICOR at vicorpower.com
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3 Vout, 75 W (e.g. V72C3V3C75BL)
Parameter
Efficiency
Min
78
Typ
80.5
105
4.3
3.2
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
132
4.46
3.7
4.14
0.2
No load to full load; nominal input
0
23.1
15.8
22.73
30.7
30.7
26.1
26.1
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
5 Vout, 100 W (e.g. V72C5C100BL)
Parameter
Efficiency
Min
81.3
Typ
82.3
120
6.25
4.2
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
150
6.47
5
0.2
20
6.03
0.02
No load to full load; nominal input
0
20.4
14
23
23
27
27
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
8 Vout, 100 W (e.g. V72C8C100BL)
Parameter
Efficiency
Min
82
Typ
83.6
180
9.7
6.3
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
225
10.1
7.5
9.36
0.2
No load to full load; nominal input
0
12.7
8.75
12.5
16.9
16.9
14.4
14.4
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
12 Vout, 150 W (e.g. V72C12C150BL)
Parameter
Efficiency
Min
85
Typ
86.3
220
14.3
4.3
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
275
14.9
5.3
13.7
0.02
0.2
No load to full load; nominal input
0
12.7
8.75
12.5
17.5
17.5
14.4
14.4
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
15 Vout, 150 W (e.g. V72C15C150BL)
Parameter
Efficiency
Min
84.2
Typ
85.9
150
17.8
3.6
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
188
18.5
4.3
0.2
10
17.1
0.02
No load to full load; nominal input
0
10.2
7
11.5
11.5
13.5
13.5
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 4 of 11
Set your site on VICOR at vicorpower.com
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
24 Vout, 150 W (e.g. V72C24C150BL)
Parameter
Efficiency
Min
83.5
Typ
84.9
116
28.1
6
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
145
29.1
7
27.1
0.02
0.2
No load to full load; nominal input
0
6.37
4.37
6.25
8.44
8.98
7.19
7.19
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
28 Vout, 150 W (e.g. V72C28C150BL)
Parameter
Efficiency
Min
85.3
Typ
86.2
105
32.7
5.3
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
132
33.9
6.2
31.5
0.02
0.2
No load to full load; nominal input
0
5.46
3.75
5.36
7.24
7.24
6.16
6.16
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
36 Vout, 150 W (e.g. V72C36C150BL)
Parameter
Efficiency
Min
85.2
Typ
86.9
72
41.9
5
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
90
43.4
5.6
40.4
0.02
0.2
No load to full load; nominal input
0
4.25
2.91
4.17
5.63
5.63
4.8
4.8
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
48 Vout, 150 W (e.g. V72C48C150BL)
Parameter
Efficiency
Min
84.2
Typ
85.3
70
55.7
6.0
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
88
57.7
6.8
53.7
0.02
0.2
No load to full load; nominal input
0
3.19
2.19
3.13
4.23
4.23
3.6
3.6
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 5 of 11
Set your site on VICOR at vicorpower.com
BASIC MODULE OPERATION
C2*
4.7nF
C4*
4.7nF
+IN
PC
PR
+OUT
SC
F1*
C1*
0.2µF
–IN
–OUT
C3*
4.7nF
C5*
4.7nF
For C1 – C5, keep leads and connections short.
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.
* See Maxi, Mini, Micro Design Guide.
Comprehensive Online Application Information
The Design Guide and Applications Manual includes:
• Application circuits
• Design requirements
• EMC considerations
• Current sharing in power arrays
• Thermal performance information
• Recommended soldering methods
• Accessory modules – filtering, rectification, front-ends
• Mounting options
...and more.
CLICKꢀHERE TOꢀVIEW
DESIGN GUIDE
Also at vicorpower.com
• PowerBench online configurators
• Over 20 Application Notes
• Online calculators – thermal, trimming, hold-up
• PDF data sheets for ALL Vicor products
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 6 of 11
Set your site on VICOR at vicorpower.com
PRIMARY CONTROL - PC PIN
Module Enable/Disable
Module Alarm
The module may be disabled by pulling PC to 0 V (2.3 V
max) with respect to the –Input. This may be done with an
open collector transistor, relay, or optocoupler. Converters
may be disabled with a single transistor or relay either directly
or via “OR’ing” diodes for 2 or more converters. See Figure 2.
The module contains “watchdog” circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will
shut down and PC will go low. PC will periodically go high
and the module will check to see if the fault (as an example,
Input Undervoltage) has cleared. If the fault has not been
cleared, PC will go low again and the cycle will restart. The
SC pin will go low in the event of a fault and return to its nor-
mal state after the fault has been cleared. See Figures 3 and 5.
Primary Auxiliary Supply
During normal operation only, the PC Pin can source 5.7 V @
1.5 mA. In the example shown in Figure 4, PC powers a mod-
ule enabled LED.
Input Undervoltage
[a]
Input Overvoltage
Over Temperature
Module Faults
+IN
+OUT
SC
+IN
PC
Auto
Restart
SW1
50 Ω
PC
PR
2-20 ms typ.
f(VIN
)
1 K
6 K
SW2
SW3
5.7 Vdc
PR
1 M
(0-3 mA)
Disable
1.23
Vdc
–IN
–OUT
SW1, 2, & 3 shown
in "Fault" position
–IN
Disable = PC < 2.3 V
[a] Not applicable for 300 Vdc Input family
Figure 2 — Module enable/disable.
Figure 3 — PC/SC module alarm logic.
+IN
PC
Fault
40 µs typ.
5.7 V
PC
4 kΩ
"Module
Enabled"
PR
1.23 V
2-20 ms typ.
SC
–IN
Figure 4 — LED on-state indicator.
Figure 5 —PC/SC module alarm timing.
+IN
+OUT
Comparator
Optocoupler
PC
SC
Alarm
PR
4 k
1.00 V
–IN
–OUT
Figure 6 —Isolated on-state indicator.
Figure 7 — Secondary side on-state indicator.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 7 of 11
Set your site on VICOR at vicorpower.com
SECONDARY CONTROL - SC PIN
PARALLEL BUS - PR PIN
Output Voltage Programming
Parallel Operation
The output voltage of the converter can be adjusted or
programmed via fixed resistors, potentiometers or voltage
DACs. See Figure 8.
The PR pin supports paralleling for increased power with N+1
(N+M) redundancy. Modules of the same input voltage, output
voltage, and power level will current share if all PR pins are
suitably interfaced.
Compatible interface architectures include the following:
AC coupled single-wire interface. All PR pins are connected
to a single communication bus through 0.001 µF (500 V)
capacitors. This interface supports current sharing and is fault
tolerant except for the communication bus. Up to three
converters may be paralleled by this method. See Figure 9.
+OUT
RU
Trim Up
Error
Load
SC
Amp
RD
Trim Down
1 kΩ
0.033 μF
Transformer coupled interface. For paralleling four or more
converters a transformer coupled interface is required. See
Figure 10.
–OUT
1.23 V
For details on parallel operation please refer to the
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
1,000 Vout
Vnom – Vout
RD (ohms) =
RU (ohms) =
4.7 nF
1,000 (Vout –1.23) Vnom
1.23 (Vout – Vnom)
– 1,000
+
–
+IN
PC
PR
–IN
0.2 µF
Z1*
Module 1
Module 2
0.001 µF
Figure 8 — Output voltage trim down and trim up circuit.
4.7 nF
4.7 nF
0.2 µF
Low inductance
ground plane
or bus
Trim Down
1. This converter is not a constant power device – it has a
constant current limit. Hence, available output power is
reduced by the same percentage that output voltage is
trimmed down. Do not exceed maximum rated output current.
+IN
PC
PR
–IN
0.001 µF
Z1*
2. The trim down resistor must be connected between the SC
and pins. Do not bypass the SC pin directly with a
capacitor.
4.7 nF
Parallel
Bus
Figure 9 — AC coupled single-wire interface.
* See Maxi, Mini, Micro Design Guide.
Trim Up
1. The converter is rated for a maximum delivered power. To
ensure that maximum rated power is not exceeded, reduce
maximum output current by the same percentage increase in
output voltage.
4.7 nF
+
–
+IN
PC
PR
–IN
0.2 µF
Z1*
2. The trim up resistor must be connected between the SC
and pins. Do not bypass the SC pin directly with a
capacitor.
Module 1
Module 2
T1
4.7 nF
4.7 nF
3. Do not trim the converter above maximum trim range
(typically +10%) or the output over voltage protection
circuitry may be activated.
+IN
PC
PR
–IN
0.2 µF
Z1*
T2
Trim resistor values calculated automatically:
On-line calculators for trim resistor values are available on the
vicor website at:
asp.vicorpower.com/calculators/calculators.asp?calc=1
Resistor values can be calculated for fixed trim up, fixed trim
down and for variable trim up or down.
4.7 nF
Parallel
Bus
Figure 10 — Transformer-coupled interface.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 8 of 11
Set your site on VICOR at vicorpower.com
PARALLEL BUS /
VOLTAGE DROP COMPENSATION
+OUT
SC
• The +Out and –Out
power buses should be
designed to minimize
and balance parasitic
impedance from each
module output to the
load.
Plane
Module #1
Designated
Master
+Out
SC
+S
R7 21.0 k
C3
R4
–OUT
R9
R1
R8
C2
0.22 µF
4.02 k
R3
U2
R5
U1
R2
2.55 k
TLV431
Vcc
1.00 k
R6
1.65 k
R Load
–
–
R11
36.5 k
C1
470 pF
+OUT
SC
200 mV
+
+
R10
1.24 k
PS2701
U3
LM10
• At the discretion of the
power system designer,
a subset of all modules
within an array may be
configured as slaves by
connecting SC to –Out.
Gnd
L
O
A
D
Module #2
trimmed
down 2 %
–S
–Out
See Component Selection section below.
–OUT
• This module is designed for point of load regulation, where remote sensing
is not required. Active voltage drop compensator, as shown here, may be
used in applications with significant distribution losses.
+OUT
SC
• Do not use output
OR’ing diodes with
MicroMods.
Module #3
trimmed
down 4 %
Ground
Plane
Please consult with the Micro Family Isolated Remote Sense Application Note
for additional information.
–OUT
Figure 11 — N+1 module array output connections.
Figure 12 — Voltage drop compensation.
PINꢀSTYLES*
Designator
Description
Short
Finish
Tin/Lead
Tin/Lead
Gold
Notes
(None)
Requires in-board, mounting
L
S
N
F
Long
On-board mounting for 0.065" boards
Short ModuMate
Long ModuMate
Short RoHS
Long RoHS
SurfMate or in-board socket mounting
Gold
On-board socket mounting
Gold
Select for RoHS compliant in-board solder, socket, or SurfMate mounting
Select for RoHS compliant on-board solder or socket mounting
G
Gold
*
Pin style designator follows the “B” after the output power and precedes the baseplate designator.
Ex. V72C15T150BN2 — Long ModuMate Pins
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 9 of 11
Set your site on VICOR at vicorpower.com
MECHANICAL DRAWINGS
Converter Pins
No. Function Label
1
+In
+
Primary
Control
2
PC
3
4
5
Parallel
–In
PR
–
–Out
–
Secondary
Control
6
7
SC
+
+Out
Figure 13 —Module outline
ALL MARKINGS
THIS SURFACE
0.062 0.010
PCB THICKNESS
1,57 0,25
0.800*
20,32
INBOARD
SOLDER
MOUNT
ONBOARD
SOLDER
MOUNT
0.525*
13,34
PLATED
0.275*
6,99
SHORT PIN STYLE
0.094 0.003
LONG PIN STYLE
ALUMINUM
BASEPLATE
THRU HOLE
DIA
0.094 0.003
(7X)
0.145*
3,68
2,39 0,08
2,39 0,08
PINS STYLES
0.133
3,38
SOLDER:TIN/LEAD PLATED
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
1
7
2
3
4
5
1.734**
44,04
2.000*
50,80
FOR SOLDERING METHODS AND PROCE-
DURES PLEASE REFER TO THE MAXI, MINI,
MICRO DESIGN GUIDE.
6
0.06
Unless otherwise specified,
dimensions are in inches
mm
R
(4X)
1,5
0.53
13,5
0.43
10,9
.400*
10,16
0.003
0,08
*DENOTES TOL =
**PCB WINDOW
Decimals
Tol.
Angles
1.090**
27,69
0.XX
0.01
0.25
0.005
0.127
1°
0.XXX
Figure 14 —PCB mounting specifications
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
Page 10 of 11
Set your site on VICOR at vicorpower.com
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or
maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original
purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products
returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the
product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability,
function, or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither
does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of
its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms
and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies
Vicor against all damages.
Vicor’s comprehensive line of powersolutions includes high density AC-DC and DC-DC modules
and accessory components, fully configurable AC-DC and DC-DC powersupplies, and complete
custom powersystems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or
malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available
upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
VicorCorporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
72V Micro Family
Rev. 2.0
05/12
Set your site on VICOR at vicorpower.com
相关型号:
©2020 ICPDF网 联系我们和版权申明