VE-21R-EX-B1 概述
CONVERTER MOD DC/DC 7.5V 75W
VE-21R-EX-B1 数据手册
通过下载VE-21R-EX-B1数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载DC-DC Converters
VI-200
VE-200
S
®
C
NRTL US
50 to 200 Watts
Features & Benefits
Product Highlights
• Isolated output
• Up to 50W/in3
The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of
“zero-current-switching” component-level DC-DC converters.
Operating at frequencies up to 2MHz, VI-200 family converters offer exceptional power
density, efficiency, noise performance, reliability and ease of use. Booster modules
(VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output
requirements. One or more boosters may be used to create synchronous arrays capable
of supplying several kilowatts of output power.
• cURus, cTÜVus
• Up to 90% efficiency
• Size: 4.6” x 2.4” x 0.5”
(116,8 x 61,0 x 12,7mm)
• Remote sense and current limit
• OVP, thermal shutdown
• Logic disable
The flexibility of Vicor’s power components is also available in half-size, half-power
VI-J00 MiniMods.
• Wide range output adjust
• Compatible power booster modules
• ZCS power architecture
• Low noise FM control
• CE Marked
• RoHS compliant (VE-200)
Part Numbering
VI
—
2
6
1
—
C
W
Family
Series
2 =200
B =Booster
Input
Output
M = 10V
1 = 12V
Grade
Power
VI=Non-RoHS
VE = RoHS
0= 12V
V= 24V
1= 24V
W= 24V
2= 36V
3= 48V
N =48V
4 = 72V
Z = 2V
K = 40V
4 = 48V
E = –10 to 85°C
C = –25 to 85°C
I = –40 to 85°C
≥ 5V
< 5V
Y = 3.3V
0 = 5V
U = 200W
V = 150W
U = 40A
V = 30A
W = 20A
X = 15A
Y = 10A
T = 110V
5 = 150V
6 = 300 V
P = 13.8V H = 52V
2 = 15V F = 72V
N = 18.5V D = 85V
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = –55 to 85°C W = 100W
X = 75W
Note: For additional
packaging options,
please see page 5.
7 = 150/300V
3 = 24V
L = 28V
J = 36V
B = 95V
Y = 50W
VI-200 DC-DC Converters
Page 1 of 7
Rev 3.9
08/2017
VI-200, VE-200
Maximum Power Available for VI-2xx-xx [a]
Input
Output
VOUT Designators
Low
Line
Voltage
75% Transient [b]
Nom. (Range)
Max
Power
Z
X
Y
X
0
X
Y
U
V
W
U
U
U
V
V
Y
U
X
X
W
X
V
X
T
X
R
X
M
X
1
X
P
X
2
X
N
X
3
X
L
X
J
X
K
X
4
X
H
F
D
B
12 (10 – 20)
24 (10 – 36)
n/a
n/a
18
22
n/a
36
0
V
1
X
X
X
X
--
U
V
X
Y
Y
Y
Y
X
X
X
X
X
X
X
X
X
X
X
-- -- -- --
24 (21 – 32)
24 (18 – 36)
U
V
U
V
U
V
U
V
V
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
n/a
18
n/a
60
W
2
W
W
U
U
V
W
W
U
36 (21 – 56)
48 (42 – 60)
48 (36 – 76)
72 (55 – 100)
110 (66 – 160)
150 (100 – 200)
150 (100 – 375)
W
U
U
v
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
-- -- --
36
72
3
U
U
U
V
U
U
U
V
U
U
U
U
U
U
U
n/a
45
n/a
110
n/a
215
n/a
425
N
4
U
V
n/a
85 [c]
n/a
T
V
W
V
W
V
-- --
5
U
W
U
U
W
U
V
V
V
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
U
7
Y
Y
Y
W
V
W
V
-- -- --
300 (200 – 400) 170 [d]
6
U
U
U
U
U
U
[a] For additional output power, “booster” modules are available. (VI-Bxx-xx).
[b] Transient voltage for 1 second.
[c] 12VOUT, 13.8VOUT, 15VOUT, 200W models are limited to 90VDC
.
[d] 15VOUT, 200W models are limited to 185VDC
.
Converter Specifications
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
Input Specifications
VI-200 E-Grade
VI-200 C-, I-, M-Grade
Test
Conditions
Parameter
Min
Typ
120 x 10-6
10%
Max
Min
Typ
120 x 10-6
10%
Max
Units
Coulombs
IIN
Inrush charge
200 x 10-6
Nominal line
Input reflected
ripple current – pp
Nominal line,
full load
VIN
VIN
120Hz,
nominal line
25+20 Log
30+20 Log
(V )
OUT
dB
dB
(V )
OUT
Input ripple
rejection
VIN
2400Hz,
nominal line
20+20 Log
(V )
OUT
No load power
dissipation
1.35
2
1.35
2
Watts
VI-200 DC-DC Converters
Page 2 of 7
Rev 3.9
08/2017
VI-200, VE-200
Converter Specifications (Cont.)
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
Output Characteristics
VI-200 E-Grade
VI-200 C-, I-, M-Grade
Test
Units
Parameter
Min
Typ
Max
2%
Min
Typ
Max
1%
Conditions
Setpoint accuracy
1%
0.5%
0.05%
VNOM
Load/line
regulation
LL to HL, 10%
VNOM
0.5%
0.2%
to Full Load
Load/line
regulation
LL to HL, No
VNOM
1%
0.2%
0.5%
0.02
Load to 10%
Output
temperature drift
Over rated
0.02
0.02
0.01
0.02
% / °C
temp.
Long term drift
Output ripple – pp:
2V, 3.3V
%/1K hours
20MHz
150
5%
60
100
3%
mV
bandwidth
20MHz
bandwidth
5V
2%
VNOM
20MHz
bandwidth
10 – 95V
3%
0.75%
1.5%
VNOM
VNOM
Trim range [a]
50%
0.5
110%
50%
0.5
110%
Total
0.25V max.
neg. leg
remote sense
compensation
Volts
OVP set point
Current limit
125% [b]
115%
105%
125% [b]
135%
125%
VNOM
Recycle power
Automatic
restart
105%
20%
135%
140%
IFULL LOAD
Short circuit
current [c]
Automatic
restart
20%
130%
IFULL LOAD
[a] 10V to 15V outputs, or “V” input range have standard trim range 10%. Consult factory for wider trim range.
3.3V output trim range 2.20 to 3.63V, 95V output –50 + 0% trim range.
[b] 131% nominal for booster modules.
[c] Output voltages of 3.3V or 5V incorporate foldback current limiting; For output voltages from 5.2V to 7.5V consult factory;
All other outputs provide constant current limiting.
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 5.
Control Pin Specifications
VI-200 E-Grade
Typ
VI-200 C-, I-, M-Grade
Typ
Test
Conditions
Parameter
Min
Max
Min
Max
Units
Gate out
impedance
50
1000
6
50
1000
6
Ohms
Ohms
Volts
Gate in impedance
Gate in open
circuit voltage
Use open
collector
Gate in low
threshold
0.65
0.95
0.65
0.95
Volts
mA
Gate in low
current
6
6
Power sharing
accuracy
1.05
1.05
VI-200 DC-DC Converters
Page 3 of 7
Rev 3.9
08/2017
VI-200, VE-200
Converter Specifications (Cont.)
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
Dielectric Withstand Characteristics
VI-200 E-Grade
VI-200 C-, I-, M-Grade
Typ
Test
Units
Parameter
Min
Typ
Max
Min
Max
Conditions
Baseplate
earthed
Input to output
3,000
3,000
VRMS
Output to
baseplate
500
500
VRMS
VRMS
Input to baseplate
1,500
1,500
Thermal Characteristics
VI-200 E-Grade
Typ
VI-200 C-, I-, M-Grade
Test
Units
Parameter
Min
Max
Min
Typ
80 – 90%
0.07
Max
Conditions
Efficiency
78 – 88%
0.07
Baseplate to sink
thermal impedance
With Vicor
°C/Watt
P/N 20266
Thermal
Cool and
recycle power
to restart
shutdown [d]
(Drivers only)
90
95
105
90
95
105
°C
[d] No overtemp protection in booster modules.
Mechanical Specifications
VI-200 E-Grade
VI-200 C-, I-, M-Grade
Typ
Test
Conditions
Parameter
Min
Typ
Max
Min
Max
Units
5.7
(160.2)
6.3
(178)
6.9
(195.8)
6.6
(187.2)
7.3
(208)
8.1
(228.8)
Ounces
(Grams)
Weight
Product Grade Temperatures
Parameter
Storage
Operating
-10 to + 85
-25 to + 85
-40 to + 85
-55 to + 85
Units
Notes
E
-20 to +100
-40 to +100
-55 to +100
-65 to +100
°C
°C
°C
°C
Overtemperature shutdown
95°C typical (recycle power
to restart)
C
I
M
Maximum Capacitance, Rated Output Voltage <5V
Rated VOUT (V)
2 to <3
IOUT Rating (A)
CMAX (µF)
1500
IOUT Rating (A)
>10 to 40
CMAX (µF)
5000
≤10
≤10
3 to <5
1000
>10 to 40
5000
Maximum Capacitance, Rated Output Voltage ≥5V
Rated VOUT (V)
5 to <7.5
7.5 to <10
10 to <28
>28
POUT Rating (W)
CMAX (µF)
1000
400
POUT Rating (W)
>50 to 200
CMAX (µF)
1500
700
≤50
≤50
≤50
≤50
>50 to 200
400
>50 to 200
500
150
>50 to 200
250
VI-200 DC-DC Converters
Page 4 of 7
Rev 3.9
08/2017
VI-200, VE-200
Basic Module Operation
C2a
C2b
C1a
C1b
F1
C3
+IN
–IN
ZeSrwoitCcuhrinregnt+OUT
Converter
–OUT
400
C3 (µF) =
VIN Minimum
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Design Guide & Applications Manual.
Output Connections and Considerations
The permissible load current[e] must never be exceeded during
normal, abnormal or test conditions. Converters subject to
dynamic loading exceeding 25% of rated current must be
Storage
Vicor products, when not installed in customer units, should
be stored in ESD safe packaging in accordance with
ANSI/ESD S20.20, “Protection of Electrical and Electronic
reviewed by Vicor Applications Engineering to ensure that the
Parts, Assemblies and Equipment” and should be maintained
converter will operate properly.
in a temperature controlled factory/warehouse environment
Under dynamic load, light load, or no load conditions, the
converter may emit audible noise. Converters that utilize remote
sense may require compensation circuitry to offset the phase
lag caused by the external output leads and load impedance.
Remote Sense leads must be protected for conditions such as
lead reversal, noise pickup, open circuit, or excessive output lead
resistance between the sense point and the converters output
terminals. For applications that may draw more than the rated
current, a fast acting electronic circuit breaker must be utilized
to protect the converter. Under no circumstance should the
rated current be exceeded. Utilizing or testing of current limit or
short circuit current will damage the converter. Ensure that the
total output capacitance connected to the converter does not
exceed the limits on Page 4.
not exposed to outside elements controlled between the
temperature ranges of 15ºC and 38ºC. Humidity shall not be
condensing, no minimum humidity when stored in an ESD
compliant package.
Nominal Power Rating
[e] Permissible load current:
Nominal VOUT
VI-200 DC-DC Converters
Page 5 of 7
Rev 3.9
08/2017
VI-200, VE-200
Mechanical Drawing
4.60
(116,8)
Standard
RoHS
0.080 (2,0) Dia (2) places
3.60
.50
0.080 (2,0) Dia (2) places
(91,4)
(12,7)
1.80
Solder plate over copper alloy Matte tin over copper alloy
(45,7)
.30±.015
(7,6)±(0,38)
Pin #
1
Function
+In
2
Gate In
Gate Out
-In
4
9
3
4
3
8
7
6
2.10
1.40
5
+Out
VI-200
(35,6)
1.00
(53,3)
.70
(25,4)
6*
7*
8*
9
+Sense
Trim
2
(17,8)
.40
(10,2)
1
5
.35±.015
(8,9)±(0,38)
-Sense
-Out
* Do not connect on booster modules
FULL R
.15
Standard
RoHS
.15
(3,8)
(3,8)
Product ID
this surface
.040 (1,0) Dia (7) places
.040 (1,0) Dia (7) places
Solder plate over copper alloy Matte tin over copper alloy
2.40
(61,0)
.30
4.20
1.75
(7,6) Min
.22
(106,7)
Max.
(44,5)
(5,6) MIN
.50
(12,7)
+.030 (0,76)
-.000 (0)
.01
.12
Aluminum Base
(3,0)
Packaging Options
SlimMod
FinMod
MegaMod
Chassis mount alternatives, one, two,
or three outputs: up to 600W
Flangeless package
Flangeless package with integral heat sink
1 up – 4.9¨ x 2.5¨ x 0.62¨ (124,4 x 63,5 x 15,7mm)
2 up – 4.9¨ x 4.9¨ x 0.62¨ (124,4 x 124,4 x 15,7mm)
3 up – 4.9¨ x 7.3¨ x 0.62¨ (124,4 x 185,4 x 15,7mm)
Longitudinal, 0.25”(6.35mm) fins — add suffix “–F1”
Longitudinal, 0.50”(12.7mm) fins — add suffix “–F2”
4.60”L x 1.80”W x 0.50”H
(116,8 x 45,7 x 12,7mm)
BusMod
To order the SlimMod configuration add the suffix “–S” to
the standard module part number.
Qty (2) grounding clips are included with each SlimMod
P/N 32187
Transverse, 0.25”(6.35mm) fins — add suffix “–F3”
Transverse, 0.50”(12.7mm) fins — add suffix “–F4”
4.60”L x 2.40”W x 1.08”H
(116,8 x 61,0 x 27,4mm)
Available with longitudinal or transverse fins of 0.25”(6.35
mm) or 0.50”(12.7mm) height. Add the
appropriate suffx to the module part number.
To order the BusMod fully assembled, add suffix “–B1” to
the standard module part number.
To order the BusMod separately:
Full-sized BusMod — P/N 06322
Qty (4) grounding clips are included with each FinMod
F1, F2 P/N 32185
F3, F4 P/N 32186
See BusMod Mechanical Drawings for more details.
VI-200 DC-DC Converters
Page 6 of 7
Rev 3.9
08/2017
VI-200, VE-200
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/vi-200_vi-j00 for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Contact Us: http://www.vicorpower.com/contact-us
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
www.vicorpower.com
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
©2017 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.
All other trademarks, product names, logos and brands are property of their respective owners.
VI-200 DC-DC Converters
Page 7 of 7
Rev 3.9
08/2017
VE-21R-EX-B1 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
VE-21R-EX-F1 | VICOR | CONVERTER MOD DC/DC 7.5V 75W | 获取价格 | |
VE-21R-EX-F2 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, | 获取价格 | |
VE-21R-EX-F3 | VICOR | CONVERTER MOD DC/DC 7.5V 75W | 获取价格 | |
VE-21R-EX-F4 | VICOR | DC DC CONVERTER 7.5V 75W | 获取价格 | |
VE-21R-EX-S | VICOR | CONVERTER MOD DC/DC 7.5V 75W | 获取价格 | |
VE-21R-EY | VICOR | CONVERTER MOD DC/DC 7.5V 50W | 获取价格 | |
VE-21R-EY-B1 | VICOR | CONVERTER MOD DC/DC 7.5V 50W | 获取价格 | |
VE-21R-EY-F1 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, | 获取价格 | |
VE-21R-EY-F2 | VICOR | CONVERTER MOD DC/DC 7.5V 50W | 获取价格 | |
VE-21R-EY-F3 | VICOR | CONVERTER MOD DC/DC 7.5V 50W | 获取价格 |
VE-21R-EX-B1 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8