VE-JT4-CX
更新时间:2024-10-29 15:20:29
品牌:VICOR
描述:DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid,
VE-JT4-CX 概述
DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, 电源模块
VE-JT4-CX 规格参数
是否无铅: | 不含铅 | 是否Rohs认证: | 符合 |
生命周期: | Active | 包装说明: | , |
Reach Compliance Code: | compliant | ECCN代码: | EAR99 |
风险等级: | 5.75 | 模拟集成电路 - 其他类型: | DC-DC REGULATED POWER SUPPLY MODULE |
最大输入电压: | 160 V | 最小输入电压: | 66 V |
标称输入电压: | 110 V | JESD-30 代码: | R-XDMA-P9 |
JESD-609代码: | e3 | 最大负载调整率: | 0.2% |
功能数量: | 1 | 输出次数: | 1 |
端子数量: | 9 | 最高工作温度: | 100 °C |
最低工作温度: | -25 °C | 最大输出电压: | 52.8 V |
最小输出电压: | 24 V | 标称输出电压: | 48 V |
封装主体材料: | UNSPECIFIED | 封装形状: | RECTANGULAR |
封装形式: | MICROELECTRONIC ASSEMBLY | 峰值回流温度(摄氏度): | NOT SPECIFIED |
认证状态: | Not Qualified | 表面贴装: | NO |
技术: | HYBRID | 温度等级: | OTHER |
端子面层: | Matte Tin (Sn) | 端子形式: | PIN/PEG |
端子位置: | DUAL | 处于峰值回流温度下的最长时间: | NOT SPECIFIED |
最大总功率输出: | 75 W | 微调/可调输出: | YES |
Base Number Matches: | 1 |
VE-JT4-CX 数据手册
通过下载VE-JT4-CX数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Half Brick, DC-DC Converters
VI-J00
VE-J00
S
®
C
NRTL US
25 to 100 Watts
Features & Benefits
Product Highlights
• Isolated output
• Up to 50W/in3
• cURus, cTÜVus
• CE Marked
The VI-J00 MiniMod family established a new standard in component-level DC-DC
converters. This “junior” size complement to the higher power VI-200 family offers up
to 100W of isolated and regulated power in a board mounted package. With thousands
of input/output/power combinations, and with a maximum operating temperature
rating of 100°C, the MiniMod provides nearly unlimited flexibiliy for power system
designers to meet demanding time to market requirements.
• Up to 90% efficiency
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven
by an installed base of over 8 million units, the MiniMod family combines state of
the art power density with the efficiency, low noise and reliability required by next
generation power systems.
• Size: 2.28” x 2.4” x 0.5”
(57,9 x 61,0 x 12,7mm)
• Remote sense and current limit
• Logic disable
• Wide range output adjust
• ZCS power architecture
• Low noise FM control
• RoHS compliant (VE verisons)
Part Numbering
VI
—
J
6
1
—
C
W
Family
Series
Input
Output
M = 10V
1 = 12V
Grade
Power
VI=Non-RoHS
VE = RoHS
J = J00
0= 12V
V= 24V
1= 24V
W= 24V
2= 36V
3= 48V
N =48V
4 = 72V
Z = 2V
K = 40V
4 = 48V
E = –10 to 100°C
≥ 5V
< 5V
Y = 3.3V
0 = 5V
C = –25 to 100°C W = 100W
I = –40 to 100°C X = 75W
M = –55 to 100°C Y = 50W
Z = 25W
W = 20A
X = 15A
Y = 10A
Z = 5A
T = 110V
5 = 150V
6 = 300V
P = 13.8V H = 52V
2 = 15V F = 72V
N = 18.5V D = 85V
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
Note: For additional
packaging options,
please see page 5.
7 = 150/300V
3 = 24V
L = 28V
J = 36V
B = 95V
VI-J00 DC-DC Converters
Page 1 of 7
Rev 3.0
06/2017
VI-J00, VE-J00
Maximum Power Available for VI-Jxx-xx
Input
Output
VOUT Designators
Low
Line
75%
Max
Voltage
Nom. (Range)
Transient[a]
Power
Z
Y
X
0
Y
X
Y
W
Y
V
Y
T
Y
Y
X
X
Y
X
X
X
X
X
Y
X
R
Y
Y
X
X
Y
X
X
X
X
X
Y
X
M
X
1
P
2
N
X
3
L
J
K
X
4
H
F
D
B
12 (10 – 20)
24 (10 – 36)
n/a
n/a
18
22
n/a
36
0
V
1
X
X
X
X
X
X
X
X
X
X
X
X
--
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
-- -- -- --
24 (21 – 32)
W
W
Y
W
W
Y
W
W
Y
W
W
Y
W
W
Y
W
W
Y
W
W
X
W
W
X
W
W
X
W
W
X
W
W
X
W
W
X
W
W
X
W
W
X
W
W
X
W
W
X
W
W
X
W
W
W
W
W
W
24 (18 – 36)
n/a
18
n/a
60
W
2
36 (21 – 56)
-- -- --
48 (42 – 60)
36
72
3
W
W
W
W
W
Y
W
W
W
W
W
Y
W
X
W
X
W
X
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
X
W
W
W
W
W
W
W
W
W
W
W
48 (36 – 76)
n/a
45
n/a
110
n/a
215
n/a
425
N
4
72 (55 – 100)
110 (66 – 160)
150 (100 – 200)
150 (100 – 375)
300 (200 – 400)
W
X
W
X
W
X
W
X
n/a
85
T
-- --
5
W
Y
W
Y
W
Y
W
Y
W
W
n/a
170
7
-- -- --
6
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
[a] Transient voltage for 1 second.
Converter Specifications
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
Input Specifications
VI-J00 E-Grade
VI-J00 C-, I-, M-Grade
Test
Conditions
Parameter
Min
Typ
60 x 10-6
10%
Max
Min
Typ
60 x 10-6
10%
Max
Units
Inrush charge
100 x 10-6
Coulombs
IIN
Nominal line
Input reflected
ripple current – pp
Nominal line,
full load
VIN
VIN
120Hz,
nominal line
25+20 Log
30+20 Log
(V )
OUT
dB
dB
(V )
OUT
Input ripple
rejection
VIN
2400Hz,
nominal line
20+20 Log
(V )
OUT
No load power
dissipation
1.35
2
1.35
2
Watts
VI-J00 DC-DC Converters
Page 2 of 7
Rev 3.0
06/2017
VI-J00, VE-J00
Converter Specifications (Cont.)
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
Output Characteristics
VI-J00 E-Grade
VI-J00 C-, I-, M-Grade
Test
Units
Parameter
Min
Typ
Max
2%
Min
Typ
Max
1%
Conditions
Setpoint accuracy
1%
0.5%
0.05%
VNOM
Load/line
regulation
LL to HL, 10%
VNOM
0.5%
0.2%
to Full Load
Load/line
regulation
LL to HL, No
VNOM
1%
0.2%
0.5%
0.02
Load to 10%
Output
temperature drift
Over rated
0.02
0.02
0.01
0.02
% / °C
temp.
Long term drift
Output ripple – pp:
2V, 3.3V
%/1K hours
20MHz
200
5%
100
2%
150
3%
mV
bandwidth
20MHz
bandwidth
5V
VNOM
20MHz
bandwidth
10 – 95V
3%
0.75%
1.5%
VNOM
VNOM
Trim range[a]
50%
0.5
110%
50%
0.5
110%
Total
0.25V max.
neg. leg
remote sense
compensation
Volts
Automatic
restart
Current limit
105%
105%
135%
140%
105%
105%
125%
130%
IFULL LOAD
IFULL LOAD
Short circuit
current
Automatic
restart
[a] 10V to 15V outputs, or “V” input range have standard trim range 10%. Consult factory for wider trim range.
95V output –50 + 0% trim range.
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 5.
Control Pin Specifications
VI-J00 E-Grade
Typ
VI-J00 C-, I-, M-Grade
Typ
Test
Conditions
Parameter
Min
Max
Min
Max
Units
Gate out
impedance
50
1000
6
50
Ohms
Ohms
Volts
Gate in impedance
1000
Gate in high
threshold
Use open
collector
6
6
Gate in low
threshold
0.65
0.65
Volts
mA
Gate in low
current
6
VI-J00 DC-DC Converters
Page 3 of 7
Rev 3.0
06/2017
VI-J00, VE-J00
Converter Specifications (Cont.)
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
Dielectric Withstand Characteristics
VI-J00 E-Grade
VI-J00 C-, I-, M-Grade
Typ
Test
Units
Parameter
Min
Typ
Max
Min
Max
Conditions
Baseplate
earthed
Input to output
3,000
3,000
VRMS
Output to
baseplate
500
500
VRMS
VRMS
Input to baseplate
1,500
1,500
Thermal Characteristics
VI-J00 E-Grade
Typ
VI-J00 C-, I-, M-Grade
Test
Units
Parameter
Efficiency
Min
Max
Min
Typ
80 – 90%
0.14
Max
Conditions
78 – 88%
0.14
With Vicor
°C/Watt
Baseplate to sink
P/N 20267
[d]
No overtemp protection in booster modules.
Mechanical Specifications
VI-J00 E-Grade
VI-J00 C-, I-, M-Grade
Typ
Test
Units
Parameter
Min
Typ
Max
Min
Max
Conditions
2.9
(82.8)
3.2
(92)
3.6
(101.2)
3.4
(96.3)
3.8
(107)
4.1
(117.7)
Ounces
(Grams)
Weight
Product Grade Temperatures
Parameter
Storage
Operating
-10 to + 100
-25 to + 100
-40 to + 100
-55 to + 100
Units
Notes
E
-20 to +105
-40 to +105
-55 to +105
-65 to +105
°C
°C
°C
°C
C
I
M
Maximum Capacitance, Rated Output Voltage <5V
Rated VOUT (V)
2 to <3
IOUT Rating (A)
CMAX (µF)
1500
IOUT Rating (A)
>10 to 20
CMAX (µF)
5000
≤10
≤10
3 to <5
1000
>10 to 20
5000
Maximum Capacitance, Rated Output Voltage ≥5V
Rated VOUT (V)
5 to <7.5
7.5 to <10
10 to <28
>28
POUT Rating (W)
CMAX (µF)
1000
400
POUT Rating (W)
>50 to 100
CMAX (µF)
1500
700
≤50
≤50
≤50
≤50
>50 to 100
400
>50 to 100
500
150
>50 to 100
250
VI-J00 DC-DC Converters
Page 4 of 7
Rev 3.0
06/2017
VI-J00, VE-J00
Basic Module Operation
C2a
C2b
C1a
C1b
F1
C3
+IN
–IN
ZeSrwoitCcuhrinregnt+OUT
Converter
–OUT
400
C3 (µF) =
VIN Minimum
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Design Guide & Applications Manual.
Output Connections and Considerations
The permissible load current[e] must never be exceeded during
normal, abnormal or test conditions. Converters subject to
dynamic loading exceeding 25% of rated current must be
Storage
Vicor products, when not installed in customer units, should
be stored in ESD safe packaging in accordance with
ANSI/ESD S20.20, “Protection of Electrical and Electronic
reviewed by Vicor Applications Engineering to ensure that the
Parts, Assemblies and Equipment” and should be maintained
converter will operate properly.
in a temperature controlled factory/warehouse environment
Under dynamic load, light load, or no load conditions, the
converter may emit audible noise. Converters that utilize remote
sense may require compensation circuitry to offset the phase
lag caused by the external output leads and load impedance.
Remote Sense leads must be protected for conditions such as
lead reversal, noise pickup, open circuit, or excessive output lead
resistance between the sense point and the converters output
terminals. For applications that may draw more than the rated
current, a fast acting electronic circuit breaker must be utilized
to protect the converter. Under no circumstance should the
rated current be exceeded. Utilizing or testing of current limit or
short circuit current will damage the converter. Ensure that the
total output capacitance connected to the converter does not
exceed the limits on Page 4.
not exposed to outside elements controlled between the
temperature ranges of 15ºC and 38ºC. Humidity shall not be
condensing, no minimum humidity when stored in an ESD
compliant package.
Nominal Power Rating
[e] Permissible load current:
Nominal VOUT
VI-J00 DC-DC Converters
Page 5 of 7
Rev 3.0
06/2017
VI-J00, VE-J00
Mechanical Drawing
2.28
(57,9)
Standard
RoHS
1.30
.49
0.080 Dia (2) places
0.080 Dia (2) places
Matte tin over copper
alloy
(33,0)
(12,4)
.65
Solder plate
(16,5)
over copper alloy
.30±.015
(7,6)±(0,38)
Pin #
Function
+In
Gate In
Gate Out
-In
+Out
+Sense
Trim
–Sense
–Out
1
2
3
4
5
6
7
8
4
3
9
8
7
6
2.10
1.40
VI-J00
(53,4)
(35,6)
1.00
.70
(17,8)
(25,4)
2
1
.40
(10,2)
5
.35± .015
(8,9)±(0,38)
9
Standard
RoHS
FULL R
.15
0.040 (1,0) Dia (7) places
Solder plate
0.040 Dia (7) places
Matte tin over copper
alloy
(3,8)
.15
(3,8)
over copper alloy
2.40
Product ID
this surface
(61,0)
1.90
(48,3)
1.75
(44,4) Max.
.30
(7,6) Min.
.22
(5,6) Min.
+.030 (0,76)
.50
-.000 (0)
(12,7)
.01
.12
(3,0)
Aluminum Base
PACKAGING OPTIONS
Flangeless package
Flangeless package
MegaMod Jr.
with integral heat sink
Chassis mount alternatives, one, two
or three outputs: up to 300W
Longitudinal, 0.25”(6.35mm) fins — add suffix “–F1”
Longitudinal, 0.50”(12.7mm) fins — add suffix “–F2”
2.28”L x 1.80”W x 0.50”H
(57,9 x 45,7 x 12,7mm)
1 up – 2.58¨ x 2.5¨ x 0.62¨ (65,5 x 63,5 x 15,7mm)
2 up – 2.58¨ x 4.9¨ x 0.62¨ (65,5 x 124,5 x 15,7mm)
3 up – 2.58¨ x 7.3¨ x 0.62¨ (65,5 x 185,4 x 15,7mm)
To order the SlimMod configuration add the suffix “–S” to
the standard module part number.
BusMod
Qty (2) grounding clips are included with each SlimMod
P/N 32187
Transverse, 0.25”(6.35mm) fins — add suffix “–F3”
Transverse, 0.50”(12.7mm) fins — add suffix “–F4”
2.28”L x 2.40”W x 1.08”H
(57,9 x 61,0 x 27,4mm)
Available with longitudinal or transverse fins of
0.25”(6.35mm) or 0.50”(12.7mm) height. Add the
appropriate suffix to the module part number.
To order the BusMod fully assembled, add suffix “–B1” to
the standard module part number.
To order the BusMod separately:
Half-sized BusMod — P/N 18952
Qty (4) grounding clips are included with each FinMod
F1, F2 P/N 32185
F3, F4 P/N 32186
See BusMod Mechanical Drawings for more details.
VI-J00 DC-DC Converters
Page 6 of 7
Rev 3.0
06/2017
VI-J00, VE-J00
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/vi-200_vi-j00 for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Contact Us: http://www.vicorpower.com/contact-us
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
www.vicorpower.com
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
©2017 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.
All other trademarks, product names, logos and brands are property of their respective owners.
VI-J00 DC-DC Converters
Page 7 of 7
Rev 3.0
06/2017
VE-JT4-CX 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
VE-JT4-CX-B1 | VICOR | CONVERTER MOD DC/DC 48V 75W | 获取价格 | |
VE-JT4-CX-F1 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, | 获取价格 | |
VE-JT4-CX-F2 | VICOR | CONVERTER MOD DC/DC 48V 75W | 获取价格 | |
VE-JT4-CX-F3 | VICOR | CONVERTER MOD DC/DC 48V 75W | 获取价格 | |
VE-JT4-CX-F4 | VICOR | CONVERTER MOD DC/DC 48V 75W | 获取价格 | |
VE-JT4-CX-S | VICOR | DC DC CONVERTER 48V 75W | 获取价格 | |
VE-JT4-CY | VICOR | DC DC CONVERTER 48V 50W | 获取价格 | |
VE-JT4-CY-B1 | VICOR | CONVERTER MOD DC/DC 48V 50W | 获取价格 | |
VE-JT4-CY-F1 | VICOR | CONVERTER MOD DC/DC 48V 50W | 获取价格 | |
VE-JT4-CY-F2 | VICOR | CONVERTER MOD DC/DC 48V 50W | 获取价格 |
VE-JT4-CX 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8