Data Sheet  
Off-Line Front Ends  
Single or Three Phase  
Strappable  
Features  
250 W, 500 W, 750 W, 115/230 Vac  
strappable single-phase  
1.5, 3, 5 kW, 208 Vac three-phase  
20 – 50 mS holdup  
UL, CSA, TÜV, VDE, BABT  
FCC/VDE Class B (single-phase)  
FCC/VDE Class A (three-phase)  
BUS OK, AC OK, DC OK status signal  
96 – 98% efficiency  
PC and chassis mount  
Front End Specifications  
(typical at T = 25˚C, nominal line, 75% load, unless otherwise specified)  
Single Phase (250, 500, 750W)  
Three Phase (1.5, 3, 5 kW)  
AC Line Input  
Strappable 115/230 Vac  
208 Vac +20%/–10%  
(Wye or Delta, ø to ø)  
N/A  
With Range Strap  
Without Range Strap  
Line Frequency  
90 Vac to 135 Vac  
180 Vac to 270 Vac  
47 to 63 Hz (C-Grade)  
47 to 440 Hz (I-Grade)  
N/A  
47 to 63 Hz (C-Grade)  
47 to 440 Hz (I-Grade)  
VI-26X, VI-J6X series compatible  
CE Marked  
Line Inrush Current  
115 Vac Operation  
230 Vac Operation  
240 Vac Operation  
35 A at peak line  
67 A at peak line  
52 A at peak line  
Product Highlights  
AC Leakage Current  
1.9 mA max. at 250 Vac,  
63 Hz (C- Grade)  
3.2 mA max. at 208 Vac, 63 Hz  
From AC line in, to highly regulated DC  
out, Vicor offers the total design solution  
through a complete family of off-line front  
end and DC-DC modular power components.  
Power Factor (at full load)  
0.52 to 0.65 (at low line input)  
0.9 (typical at nom. line)  
Holdup Time (at full load)  
Low Line  
250 W (60 Hz): 4 ms min.  
500, 750 W (60 Hz): 7 ms min.  
250 W (60 Hz): 27 ms min.  
500, 750 W (60 Hz): 29 ms. min.  
Nominal Line  
20 ms min. (47 Hz)  
5 ms min.  
Vicor’s family of off-line front ends  
AC Fail Warning Time  
(at full load)  
250W: None  
500, 750W: 6 ms min.  
interface VI-260 and VI-J60 series DC-DC  
converters, and MegaMods, to 100, 115,  
230 or 240 Vac single-phase and 208 Vac  
three-phase mains. In addition, front ends  
provide conducted EMI/RFI filtering to  
FCC/VDE (Class B single-phase, Class A  
three-phase), transient surge protection,  
active inrush limiting, a BUS OK status  
output (suitable for controlling Vicor  
DC-DC converter modules via their Gate In  
pin) and an AC OK status output for sys-  
tem use in the event of loss of the AC line.  
Module Gate Control Output  
(open drain FET, non-isolated,  
referenced to –DC output)  
Called BUS OK  
Called Module Enable  
ENABLE Active High (FET cutoff) Active High (FET cutoff)  
Vds max. 18 V transorb clamp  
Power up threshold DC bus:  
Power-up threshold >227 V  
Vds max: 15 V zener clamp  
250 W: 216 V, 12%  
500, 750 W: 244, 3.5%  
ENABLE  
Inactive state (DC BUS <190 V 5%)  
Current sinking 100 mA @  
.3 Vds max., threshold DC bus  
250 W: 172 V, 16%  
Inactive state (DC BUS <187 Vdc)  
Current sinking 100 mA @  
.3Vds max.  
500, 750 W: 175 V, 3.5%  
AC OK and BUS OK Status  
Outputs (optically isolated,  
transistor output; 500 W,  
750 W only)  
500, 750 W only  
AC OK and BUS OK  
70 Vce max.  
Operating Temperature  
(Free Convection)  
C: 0°C to +50°C (750 W: +45°C)  
I: -20°C to +50°C (750 W: +45°C)  
Off State Breakdown  
Voltage  
70 Vce max.  
On State Voltage  
On State Current  
On State Threshold  
(no load)  
Off State Threshold  
(load dependent)  
.4 Vce (sat.) max. at 1 mA  
15 mA max.  
80 – 89 Vac  
.4 Vce (sat.) max. at 1 mA  
15 mA max.  
>210 Vdc/187 Vac  
Storage Temperature  
85 – 76Vac  
<205 Vdc/<182 Vac  
-40°C to +80°C  
Conducted EMI/RFI  
Dielectric Withstand  
VDE 0871/FCC part 15, Class B  
AC line (both phases)  
to GND or case  
VDE 0871/FCC part 15, Class A  
AC line (all phases)  
to GND orcase  
1.5 kVAC; 2121 Vdc  
1.5 kVAC; 2121 Vdc  
Transient Surge Withstand  
Capability (with no  
disruption of function)  
Common Mode  
IEC 61000-4-5, Level 3  
IEC 61000-4-5, Level 3  
1.2/50 µs, 2 kV,  
either polarity  
1.2/50 µs, 2 kV,  
either polarity  
0 to 360 degree phase angle with  
respect to AC line  
0 to 360 degree phase angle with  
respect to AC line  
Normal Mode  
1.2/50 µs, 1 kV pulse,  
either polarity  
1.2/50 µs, 1 kV pulse,  
either polarity  
0 to 360 degree phase angle with  
respect to AC line  
0 to 360 degree phase angle with  
respect to AC line  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
Off-Line Front Ends  
Rev.1.3  
Page 1 of 5  
Set your site on VICOR at www.vicorpower.com  
THERMAL CONSIDERATIONS  
Free Convection Derating  
750W  
• 250 W: Derate output power linearly at 7.2 W/˚C over 50˚C.  
• 500 W: Derate output power linearly at 14.3 W/˚C over 50˚C.  
• 750 W: Derate output power linearly at 18.8 W/˚C over 45˚C.  
80  
70  
60  
50  
40  
Forced Convection  
The curves below represent worst case data for chassis mount-  
ed (enclosed) front ends, i.e., low line, full load. System con-  
ditions such as higher line voltage, lighter load or PC mount  
versions of the front ends will increase reliability if the data  
here is used as the nominal design criteria.  
0
100  
200  
300  
400  
500  
600  
The sigmoid shape of the curves at low air flows is due to the  
chassis mount cover restricting the airflow to the inboard com-  
ponents until an airflow of approximately 200 LFM is  
Airflow (LFM)  
achieved. Thereafter, the velocity of air rushing over the cover  
causes air to be pulled in through the side perforations, caus-  
ing a rapid improvement of cooling of internal components.  
Front End Selection Chart  
Model  
PC  
Mounting  
Chassis  
Output Power (Watts)  
Single Phase  
250  
500  
750  
Max. Amb. Temp. vs. Airflow (LFM) Over Cover  
(Full Load, 90 Vac In, Chassis Mount)  
VI-FPE6-CUX  
VI-FKE6-CUX  
VI-FPE6-CQX  
VI-FKE6-CQX  
VI-FPE6-CMX  
VI-FKE6-CMX  
250W  
80  
70  
60  
50  
40  
Three Phase  
1,500 3,000 5,000  
VI-TKY6-CHX  
VI-TKY6-CEX  
VI-TRY6-CCX  
0
100  
200  
300  
400  
500  
600  
Airflow (LFM)  
500W  
80  
70  
60  
50  
40  
0
100  
200  
300  
400  
500  
600  
Airflow (LFM)  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
Off-Line Front Ends  
Rev.1.3  
Page 2 of 5  
Set your site on VICOR at www.vicorpower.com  
Single Phase Front End Connection Diagram  
INPUT  
OUTPUT  
Ground all baseplates  
to Earth Ground  
(500 W, 750 W front end only)  
AC-OK+  
AC-OK–  
BUS-OK  
+V  
EARTH  
Vce sat.  
<70 V  
Earth Ground  
GROUND  
F1  
F2  
F3  
F4  
Fn  
<0.4 V @  
1.5 mA  
+IN  
L1 (Phase)  
GATE IN  
VI-x6x  
A.C. MAINS  
Module  
L2 (Neutral)  
–IN  
VDC–  
VDC+  
CONNECT  
ST1  
ST2  
ST1 TO ST2  
FOR 115 Vac  
OPEN FOR  
230 Vac  
+IN  
GATE IN  
VI-x6x  
Module  
–IN  
USE #4 HARDWARE  
TORQUED @ 5 in.-lbs.  
(4 PLACES)  
FUSING INFORMATION  
+IN  
GATE IN  
VI-x6x  
Module  
FOR SAFE OPERATION, REPLACE ONLY  
WITH RECOMMENDED FUSES  
–IN  
250 W — FUSE 1: 6.3 A / 250 V (IEC 5 x 20 mm) BUSSMAN  
GDB-6.3 OR 7 A / 250 V (3AG 1/4" x 1 1/4") LITTLEFUSE  
314-007 OR BUSSMAN MTH-7 OR ABC-7  
+IN  
GATE IN  
VI-x6x  
Module  
FUSES 2,3,4...n: 3 A / 250 V BUSSMAN PC-TRON  
–IN  
500 W — FUSE 1: 12A/250V BUSSMAN ABC-12,  
LITTLEFUSE 314-012  
FUSES 2,3,4...n: 3 A / 250 V BUSSMAN PC-TRON  
750 W — FUSE 1: 15 A / 250 V BUSSMAN ABC-15,  
LITTLEFUSE 314-015  
FUSES 2,3,4...n: 3 A / 250 V BUSSMAN PC-TRON  
Notes:  
1. If input power is applied with the DC output BUS shorted, the active inrush circuitry will usually prevent Fuse 1 from blowing.  
Remove power, clear shorts, wait a few minutes and reapply input power.  
2. If unit is strapped for 115V operation and 230V is applied, the internal overvoltage crowbar will clear Fuse 1. Replace fuse, strap correctly and reapply power.  
3. To control EMI/RFI most effectively, the return path to earth ground from either the front end or modules should be made via a good RF ground.  
User must assure proper grounding for safe operation.  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
Off-Line Front Ends  
Rev.1.3  
Page 3 of 5  
Set your site on VICOR at www.vicorpower.com  
Three Phase Front End Connection Diagram (1.5 kW, 3.0 kW only)  
Vce sat.<0.4 V  
F2  
@ 1.5 mA  
+V  
<70 V  
+IN  
GATE IN  
BUS-OK +  
BUS-OK –  
AC-OK +  
AC-OK –  
VI-x6x  
Module  
L3  
+V  
<70 V  
AC  
L2  
–IN  
MAINS  
L1  
N
F3  
F4  
Fn  
MOD ENBL  
Vdc+  
+IN  
GND  
EARTH  
GROUND  
Vdc–  
GATE IN  
VI-x6x  
Module  
–IN  
CAUTION: External capacitors connected to +Vdc and –Vdc will  
significantly increase inrush current. Also these capacitors are sub-  
ject to AC ripple voltages of approximately 40 V at full load.  
+IN  
GATE IN  
VI-x6x  
Module  
–IN  
+IN  
GATE IN  
VI-x6x  
Module  
[a] To control EMC most effectively, the return path to  
ground from either the front-end or modules should be made  
via a good RF ground (i.e., a braided wire) if possible.  
–IN  
NOTE: x,y capacitors not shown for clarity  
Three Phase Front End Connection Diagram (5.0 kW only)  
[a]  
Ground All Baseplates to Earth Ground  
Vce sat.<0.4V  
@ 1.5 mA  
F2  
+IN  
GATE IN  
+V  
CAUTION: External capacitors  
connected to +Vdc and –Vdc  
will significantly increase inrush  
current. Also these capacitors are  
subject to AC ripple voltages of  
approximately 40 V at full load.  
BUS-OK +  
<70 V  
VI-x6x  
Module  
BUS-OK –  
+V  
<70 V  
AC-OK +  
AC-OK –  
–IN  
MOD ENBL  
F3  
+IN  
GATE IN  
Vdc+  
VI-x6x  
Module  
Vdc–  
–IN  
L3  
L2  
AC  
MAINS  
F4  
L1  
+IN  
N
GND  
GATE IN  
VI-x6x  
Module  
EARTH  
GROUND  
–IN  
Fn  
+IN  
GATE IN  
VI-x6x  
Module  
–IN  
[a] To control EMC most effectively, the return path to  
ground from either the front-end or modules should be made  
via a good RF ground (i.e., a braided wire) if possible.  
NOTE: x,y capacitors not shown for clarity  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
Off-Line Front Ends  
Rev.1.3  
Page 4 of 5  
Set your site on VICOR at www.vicorpower.com  
Warranty  
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in  
normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper applica-  
tion or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the  
original purchaser only.  
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT  
NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warran-  
ty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions.  
Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in  
returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms  
of this warranty.  
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is  
assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve  
reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or  
circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not  
recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten  
life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes  
all risks of such use and indemnifies Vicor against all damages.  
Vicor’s comprehensive line of power solutions includes high density AC-DC  
and DC-DC modules and accessory components, fully configurable AC-DC  
and DC-DC power supplies, and complete custom power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor  
for its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a fail-  
ure or malfunction could result in injury or death. All sales are subject to Vicors Terms and Conditions of Sale, which  
are available upon request.  
Specifications are subject to change without notice.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending  
patent applications) relating to the products described in this data sheet. Interested parties should contact  
Vicor's Intellectual Property Department.  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
Fax: 978-475-6715  
email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
Off-Line Front Ends  
Rev. 1.3  
3/09  
Set your site on VICOR at www.vicorpower.com  

相关型号:

VE-XXH

POWER RELAY 1 POLE-5 A (MEDIUM LOAD CONTROL)
FUJITSU

VE02308000J0G

Strip Terminal Block
AMPHENOL

VE02313100J0G

Strip Terminal Block
AMPHENOL

VE02314100J0G

Strip Terminal Block
AMPHENOL

VE02315000J0G

Strip Terminal Block
AMPHENOL

VE02315100J0G

Strip Terminal Block
AMPHENOL

VE02318000J0G

Strip Terminal Block
AMPHENOL

VE02318100J0G

Strip Terminal Block
AMPHENOL

VE02319100J0G

Strip Terminal Block
AMPHENOL

VE02320100J0G

Strip Terminal Block
AMPHENOL

VE02322000J0G

Strip Terminal Block
AMPHENOL

VE02323000J0G

Strip Terminal Block
AMPHENOL