VE-TKY6-CHX [VICOR]
AC-DC Regulated Power Supply Module, 1 Output, 1500W, Hybrid, PACKAGE-10;型号: | VE-TKY6-CHX |
厂家: | VICOR CORPORATION |
描述: | AC-DC Regulated Power Supply Module, 1 Output, 1500W, Hybrid, PACKAGE-10 |
文件: | 总5页 (文件大小:196K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Data Sheet
Off-Line Front Ends
Single or Three Phase
Strappable
Features
•
250 W, 500 W, 750 W, 115/230 Vac
strappable single-phase
•
1.5, 3, 5 kW, 208 Vac three-phase
20 – 50 mS holdup
UL, CSA, TÜV, VDE, BABT
FCC/VDE Class B (single-phase)
FCC/VDE Class A (three-phase)
BUS OK, AC OK, DC OK status signal
96 – 98% efficiency
PC and chassis mount
•
Front End Specifications
(typical at T = 25˚C, nominal line, 75% load, unless otherwise specified)
•
•
Single Phase (250, 500, 750W)
Three Phase (1.5, 3, 5 kW)
•
AC Line Input
Strappable 115/230 Vac
208 Vac +20%/–10%
(Wye or Delta, ø to ø)
N/A
•
•
With Range Strap
Without Range Strap
Line Frequency
90 Vac to 135 Vac
180 Vac to 270 Vac
47 to 63 Hz (C-Grade)
47 to 440 Hz (I-Grade)
N/A
•
47 to 63 Hz (C-Grade)
47 to 440 Hz (I-Grade)
•
VI-26X, VI-J6X series compatible
CE Marked
•
Line Inrush Current
115 Vac Operation
230 Vac Operation
240 Vac Operation
35 A at peak line
67 A at peak line
52 A at peak line
Product Highlights
AC Leakage Current
1.9 mA max. at 250 Vac,
63 Hz (C- Grade)
3.2 mA max. at 208 Vac, 63 Hz
From AC line in, to highly regulated DC
out, Vicor offers the total design solution
through a complete family of off-line front
end and DC-DC modular power components.
Power Factor (at full load)
0.52 to 0.65 (at low line input)
0.9 (typical at nom. line)
Holdup Time (at full load)
Low Line
250 W (60 Hz): 4 ms min.
500, 750 W (60 Hz): 7 ms min.
250 W (60 Hz): 27 ms min.
500, 750 W (60 Hz): 29 ms. min.
Nominal Line
20 ms min. (47 Hz)
5 ms min.
Vicor’s family of off-line front ends
AC Fail Warning Time
(at full load)
250W: None
500, 750W: 6 ms min.
interface VI-260 and VI-J60 series DC-DC
converters, and MegaMods, to 100, 115,
230 or 240 Vac single-phase and 208 Vac
three-phase mains. In addition, front ends
provide conducted EMI/RFI filtering to
FCC/VDE (Class B single-phase, Class A
three-phase), transient surge protection,
active inrush limiting, a BUS OK status
output (suitable for controlling Vicor
DC-DC converter modules via their Gate In
pin) and an AC OK status output for sys-
tem use in the event of loss of the AC line.
Module Gate Control Output
(open drain FET, non-isolated,
referenced to –DC output)
Called BUS OK
Called Module Enable
ENABLE Active High (FET cutoff) Active High (FET cutoff)
Vds max. 18 V transorb clamp
Power up threshold DC bus:
Power-up threshold >227 V
Vds max: 15 V zener clamp
250 W: 216 V, 12%
500, 750 W: 244, 3.5%
ENABLE
Inactive state (DC BUS <190 V 5%)
Current sinking 100 mA @
.3 Vds max., threshold DC bus
250 W: 172 V, 16%
Inactive state (DC BUS <187 Vdc)
Current sinking 100 mA @
.3Vds max.
500, 750 W: 175 V, 3.5%
AC OK and BUS OK Status
Outputs (optically isolated,
transistor output; 500 W,
750 W only)
500, 750 W only
AC OK and BUS OK
70 Vce max.
Operating Temperature
(Free Convection)
C: 0°C to +50°C (750 W: +45°C)
I: -20°C to +50°C (750 W: +45°C)
Off State Breakdown
Voltage
70 Vce max.
On State Voltage
On State Current
On State Threshold
(no load)
Off State Threshold
(load dependent)
.4 Vce (sat.) max. at 1 mA
15 mA max.
80 – 89 Vac
.4 Vce (sat.) max. at 1 mA
15 mA max.
>210 Vdc/187 Vac
Storage Temperature
85 – 76Vac
<205 Vdc/<182 Vac
-40°C to +80°C
Conducted EMI/RFI
Dielectric Withstand
VDE 0871/FCC part 15, Class B
AC line (both phases)
to GND or case
VDE 0871/FCC part 15, Class A
AC line (all phases)
to GND orcase
1.5 kVAC; 2121 Vdc
1.5 kVAC; 2121 Vdc
Transient Surge Withstand
Capability (with no
disruption of function)
Common Mode
IEC 61000-4-5, Level 3
IEC 61000-4-5, Level 3
1.2/50 µs, 2 kV,
either polarity
1.2/50 µs, 2 kV,
either polarity
0 to 360 degree phase angle with
respect to AC line
0 to 360 degree phase angle with
respect to AC line
Normal Mode
1.2/50 µs, 1 kV pulse,
either polarity
1.2/50 µs, 1 kV pulse,
either polarity
0 to 360 degree phase angle with
respect to AC line
0 to 360 degree phase angle with
respect to AC line
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Off-Line Front Ends
Rev.1.3
Page 1 of 5
Set your site on VICOR at www.vicorpower.com
THERMAL CONSIDERATIONS
Free Convection Derating
750W
• 250 W: Derate output power linearly at 7.2 W/˚C over 50˚C.
• 500 W: Derate output power linearly at 14.3 W/˚C over 50˚C.
• 750 W: Derate output power linearly at 18.8 W/˚C over 45˚C.
80
70
60
50
40
Forced Convection
The curves below represent worst case data for chassis mount-
ed (enclosed) front ends, i.e., low line, full load. System con-
ditions such as higher line voltage, lighter load or PC mount
versions of the front ends will increase reliability if the data
here is used as the nominal design criteria.
0
100
200
300
400
500
600
The sigmoid shape of the curves at low air flows is due to the
chassis mount cover restricting the airflow to the inboard com-
ponents until an airflow of approximately 200 LFM is
Airflow (LFM)
achieved. Thereafter, the velocity of air rushing over the cover
causes air to be pulled in through the side perforations, caus-
ing a rapid improvement of cooling of internal components.
Front End Selection Chart
Model
PC
Mounting
Chassis
Output Power (Watts)
Single Phase
250
500
750
Max. Amb. Temp. vs. Airflow (LFM) Over Cover
(Full Load, 90 Vac In, Chassis Mount)
VI-FPE6-CUX
VI-FKE6-CUX
VI-FPE6-CQX
VI-FKE6-CQX
VI-FPE6-CMX
VI-FKE6-CMX
■
■
■
■
■
■
■
■
■
■
250W
■
■
80
70
60
50
40
Three Phase
1,500 3,000 5,000
VI-TKY6-CHX
VI-TKY6-CEX
VI-TRY6-CCX
■
■
■
■
■
■
0
100
200
300
400
500
600
Airflow (LFM)
500W
80
70
60
50
40
0
100
200
300
400
500
600
Airflow (LFM)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Off-Line Front Ends
Rev.1.3
Page 2 of 5
Set your site on VICOR at www.vicorpower.com
Single Phase Front End Connection Diagram
INPUT
OUTPUT
Ground all baseplates
to Earth Ground
(500 W, 750 W front end only)
AC-OK+
AC-OK–
BUS-OK
+V
EARTH
Vce sat.
<70 V
Earth Ground
GROUND
F1
F2
F3
F4
Fn
<0.4 V @
1.5 mA
+IN
L1 (Phase)
GATE IN
VI-x6x
A.C. MAINS
Module
L2 (Neutral)
–IN
VDC–
VDC+
CONNECT
ST1
ST2
ST1 TO ST2
FOR 115 Vac
OPEN FOR
230 Vac
+IN
GATE IN
VI-x6x
Module
–IN
USE #4 HARDWARE
TORQUED @ 5 in.-lbs.
(4 PLACES)
FUSING INFORMATION
+IN
GATE IN
VI-x6x
Module
FOR SAFE OPERATION, REPLACE ONLY
WITH RECOMMENDED FUSES
–IN
250 W — FUSE 1: 6.3 A / 250 V (IEC 5 x 20 mm) BUSSMAN
GDB-6.3 OR 7 A / 250 V (3AG 1/4" x 1 1/4") LITTLEFUSE
314-007 OR BUSSMAN MTH-7 OR ABC-7
+IN
GATE IN
VI-x6x
Module
FUSES 2,3,4...n: 3 A / 250 V BUSSMAN PC-TRON
–IN
500 W — FUSE 1: 12A/250V BUSSMAN ABC-12,
LITTLEFUSE 314-012
FUSES 2,3,4...n: 3 A / 250 V BUSSMAN PC-TRON
750 W — FUSE 1: 15 A / 250 V BUSSMAN ABC-15,
LITTLEFUSE 314-015
FUSES 2,3,4...n: 3 A / 250 V BUSSMAN PC-TRON
Notes:
1. If input power is applied with the DC output BUS shorted, the active inrush circuitry will usually prevent Fuse 1 from blowing.
Remove power, clear shorts, wait a few minutes and reapply input power.
2. If unit is strapped for 115V operation and 230V is applied, the internal overvoltage crowbar will clear Fuse 1. Replace fuse, strap correctly and reapply power.
3. To control EMI/RFI most effectively, the return path to earth ground from either the front end or modules should be made via a good RF ground.
User must assure proper grounding for safe operation.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Off-Line Front Ends
Rev.1.3
Page 3 of 5
Set your site on VICOR at www.vicorpower.com
Three Phase Front End Connection Diagram (1.5 kW, 3.0 kW only)
Vce sat.<0.4 V
F2
@ 1.5 mA
+V
<70 V
+IN
GATE IN
BUS-OK +
BUS-OK –
AC-OK +
AC-OK –
VI-x6x
Module
L3
+V
<70 V
AC
L2
–IN
MAINS
L1
N
F3
F4
Fn
MOD ENBL
Vdc+
+IN
GND
EARTH
GROUND
Vdc–
GATE IN
VI-x6x
Module
–IN
CAUTION: External capacitors connected to +Vdc and –Vdc will
significantly increase inrush current. Also these capacitors are sub-
ject to AC ripple voltages of approximately 40 V at full load.
+IN
GATE IN
VI-x6x
Module
–IN
+IN
GATE IN
VI-x6x
Module
[a] To control EMC most effectively, the return path to
ground from either the front-end or modules should be made
via a good RF ground (i.e., a braided wire) if possible.
–IN
NOTE: x,y capacitors not shown for clarity
Three Phase Front End Connection Diagram (5.0 kW only)
[a]
Ground All Baseplates to Earth Ground
Vce sat.<0.4V
@ 1.5 mA
F2
+IN
GATE IN
+V
CAUTION: External capacitors
connected to +Vdc and –Vdc
will significantly increase inrush
current. Also these capacitors are
subject to AC ripple voltages of
approximately 40 V at full load.
BUS-OK +
<70 V
VI-x6x
Module
BUS-OK –
+V
<70 V
AC-OK +
AC-OK –
–IN
MOD ENBL
F3
+IN
GATE IN
Vdc+
VI-x6x
Module
Vdc–
–IN
L3
L2
AC
MAINS
F4
L1
+IN
N
GND
GATE IN
VI-x6x
Module
EARTH
GROUND
–IN
Fn
+IN
GATE IN
VI-x6x
Module
–IN
[a] To control EMC most effectively, the return path to
ground from either the front-end or modules should be made
via a good RF ground (i.e., a braided wire) if possible.
NOTE: x,y capacitors not shown for clarity
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Off-Line Front Ends
Rev.1.3
Page 4 of 5
Set your site on VICOR at www.vicorpower.com
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in
normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper applica-
tion or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the
original purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warran-
ty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions.
Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in
returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms
of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve
reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or
circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not
recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten
life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes
all risks of such use and indemnifies Vicor against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor
for its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a fail-
ure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which
are available upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending
patent applications) relating to the products described in this data sheet. Interested parties should contact
Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Off-Line Front Ends
Rev. 1.3
3/09
Set your site on VICOR at www.vicorpower.com