Data Sheet  
VI-200, VE-200  
DC-DC Converters  
50 to 200 Watts  
Features  
RoHS compliant (VE-200)  
3
Up to 50 W/in  
cULus, cTÜVus  
Product Highlights  
Up to 90% efficiency  
Size: 4.6" x 2.4" x 0.5"  
(116,8 x 61,0 x 12,7mm)  
Remote sense and current limit  
OVP, thermal shutdown  
Logic disable  
Wide range output adjust  
Compatible power booster modules  
ZCS power architecture  
Low noise FM control  
CE Marked  
The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of  
“zero-current-switching” component-level DC-DC converters.  
Operating at frequencies up to 2 MHz, VI-200 family converters offer exceptional power  
density, efficiency, noise performance, reliability and ease of use. Booster modules  
(VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output  
requirements. One or more boosters may be used to create synchronous arrays capable of  
supplying several kilowatts of output power.  
The flexibility of Vicor’s power components is also available in half-size, half-power  
VI-J00 MiniMods.  
Isolated output  
Part Numbering  
VI  
2
6
1
C
W
Family  
Series  
Input  
Output  
M = 10V  
1 = 12V  
Grade  
Power  
VI = Non-RoHS 2 =200  
0= 12 V N =48V  
V= 24 V 4 = 72V  
1= 24V T = 110V  
Z = 2V  
K = 40V  
4 = 48V  
E = –10 to 85°C  
C = –25 to 85°C  
I = 40 to 85°C  
5 V  
< 5 V  
VE = RoHS  
B =Booster  
Y = 3.3V  
0 = 5V  
U = 200 W  
V = 150W  
U = 40 A  
V = 30 A  
P = 13.8V H = 52V  
2 = 15V F = 72V  
W= 24V  
2= 36V  
3= 48V  
5 = 150V  
6 = 300V  
X = 5.2V  
M = –55 to 85°C W = 100 W W = 20 A  
Note: For additional  
packaging options,  
please see page 4.  
W = 5.5V N = 18.5V D = 85V  
X = 75 W  
Y = 50 W  
X = 15 A  
Y = 10 A  
7 = 150/300V  
V = 5.8V  
T = 6.5V  
R = 7.5V  
3 = 24V  
L = 28V  
J = 36V  
B = 95V  
Maximum Power Available for VI-2xx-xx[a]  
Input  
Low Line  
75%  
Max Power  
Output  
Vout Designators  
5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36 40 48 52 72 85 95  
Voltage  
Nom. (Range)  
Vin  
Designators  
Transient[b]  
2
Z
3.3  
Y
5
0
X
X
Y
U
V
W
U
U
U
V
V
Y
U
W
X
V
X
Y
U
V
W
U
U
U
V
V
Y
U
T
R
X
M
X
1
X
P
X
2
X
N
X
3
X
L
X
J
X
K
X
4
X
H
F
D
B
12 (10-20)  
24 (10-36)  
n/a  
22  
n/a  
36  
0
V
1
X
--  
U
V
W
U
V
U
V
U
W
U
X
X
Y
U
V
W
U
U
U
V
V
Y
U
X
X
X
X
X
n/a  
X
Y
Y
V
X
X
X
X
X
X
X
X
X
X
X
-- -- -- --  
24 (21-32)  
18  
U
V
U
V
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
24 (18-36)  
n/a  
n/a  
60  
W
2
W
W
U
U
V
W
W
U
U
V
36 (21-56)  
18  
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
-- -- --  
48 (42-60)  
36  
72  
3
U
U
U
V
U
U
U
V
U
U
U
U
U
U
U
48 (36-76)  
n/a  
n/a  
110  
n/a  
215  
n/a  
425  
N
4
72 (55-100)  
110 (66-160)  
150 (100-200)  
150 (100-375)  
300 (200-400)  
45  
n/a  
85[c]  
T
5
W
V
W
V
-- --  
U
W
U
V
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
W
U
U
U
n/a  
170[d]  
7
Y
W
V
W
V
-- -- --  
6
U
U
U
U
[a] For additional output power, “booster” modules are available. (VI-Bxx-xx)  
[b] Transient voltage for 1 second.  
[c] 15 Vout, 200 W models are limited to 90 Vdc  
[d] 15 Vout, 200 W models are limited to 185 Vdc  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
VI-200 DC-DC Converters 50 to 200 Watts  
Rev. 3.1  
Page 1 of 5  
Set your site on VICOR at vicorpower.com  
CONVERTER SPECIFICATIONS  
(typical at T = 25°C, nominal line and 75% load, unless otherwise specified)  
BP  
INPUT SPECIFICATIONS  
VI-200 E-Grade  
Typ  
VI-200 C-, I-, M-Grade  
Parameter  
Min  
Max  
Min  
Typ  
Max  
Units  
Test Conditions  
Inrush charge  
120x10-6  
120x10-6  
200x10-6  
Coulombs Nominal line  
Input reflected  
ripple current – pp  
10%  
10%  
I
IN  
Nominal line, full load  
120 Hz, nominal line  
2400 Hz, nominal line  
Vin  
Vout  
Vin  
Input ripple rejection  
dB  
dB  
25+20Log  
30+20Log  
(
)
(
(
)
)
Vout  
Vin  
Vout  
20+20Log  
1.35  
No load power dissipation  
1.35  
2
2
Watts  
OUTPUT CHARACTERISTICS  
VI-200 E-Grade  
Typ  
VI-200 C-, I-, M-Grade  
Parameter  
Min  
Max  
2%  
Min  
Typ  
0.5%  
0.05%  
0.2%  
0.01  
Max  
Units  
VNOM  
VNOM  
Test Conditions  
Setpoint accuracy  
Load/line regulation  
Load/line regulation  
Output temperature drift  
Long term drift  
1%  
1%  
0.5%  
1%  
0.2%  
0.5%  
0.02  
LL to HL, 10% to Full Load  
LL to HL, No Load to 10%  
Over rated temp.  
V
NOM  
0.02  
0.02  
% / °C  
0.02  
%/1K hours  
Output ripple – pp:  
2 V, 3.3 V  
150  
5%  
3%  
60  
2%  
100  
3%  
mV  
20 MHz bandwidth  
20 MHz bandwidth  
20 MHz bandwidth  
5 V  
VNOM  
VNOM  
10 – 95 V  
0.75%  
1.5%  
Trim range[a]  
50%  
0.5  
110%  
50%  
0.5  
110%  
VNOM  
Total remote  
sense compensation  
Volts  
0.25 V max. neg. leg  
OVP set point  
125%[b]  
115%  
105%  
20%  
125%[b]  
135%  
125%  
130%  
VNOM  
INOM  
INOM  
Recycle power  
Current limit  
105%  
20%  
135%  
140%  
Automatic restart  
Short circuit current[c]  
[a]  
10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range 10%. Consult factory for wider trim range.  
3.3 V output trim range 2.20 to 3.63 V, 95 V output –50 + 0% trim range.  
131% nominal for booster modules.  
[b]  
[c]  
Output voltages of 3.3 V or 5 V incorporate foldback current limiting; For output voltages from 5.2 V to 7.5 V consult factory; All other outputs provide constant current limiting.  
CONTROL PIN SPECIFICATIONS  
VI-200 E-Grade  
Typ  
VI-200 C-, I-, M-Grade  
Parameter  
Min  
Max  
Min  
Typ  
Max  
Units  
Ohms  
Ohms  
Volts  
Volts  
mA  
Test Conditions  
Gate out impedance  
Gate in impedance  
50  
1000  
6
50  
1000  
6
Gate in open circuit voltage  
Gate in low threshold  
Gate in low current  
Use open collector  
0.65  
0.95  
0.65  
0.95  
6
6
Power sharing accuracy  
1.05  
1.05  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
VI-200 DC-DC Converters 50 to 200 Watts  
Rev. 3.1  
Page 2 of 5  
Set your site on VICOR at vicorpower.com  
CONVERTER SPECIFICATIONS (cont.)  
DIELECTRIC WITHSTAND CHARACTERISTICS  
VI-200 E-Grade  
VI-200 C-, I-, M-Grade  
Typ Max  
Parameter  
Min  
3,000  
500  
Typ  
Max  
Min  
3,000  
500  
Units  
VRMS  
VRMS  
VRMS  
Test Conditions  
Input to output  
Output to baseplate  
Input to baseplate  
Baseplate earthed  
1,500  
1,500  
THERMAL CHARACTERISTICS  
VI-200 E-Grade  
Typ  
VI-200 C-, I-, M-Grade  
Parameter  
Min  
Max  
Min  
Typ  
Max  
Units  
Test Conditions  
Efficiency  
78 – 88%  
0.07  
80 – 90%  
Baseplate to sink  
thermal impedance  
0.07  
95  
°C/Watt  
With Vicor P/N 20266  
Thermal shutdown[d]  
(Drivers only)  
Cool and recycle power  
to restart  
90  
95  
105  
90  
105  
°C  
[d]  
No overtemp protection in booster modules.  
MECHANICAL SPECIFICATIONS  
VI-200 E-, C-Grade  
VI-200 I-, M-Grade  
Typ  
Parameter  
Min  
Typ  
Max  
Min  
Max  
Units  
Test Conditions  
5.7  
(160.2)  
6.3  
(178)  
6.9  
(195.8)  
6.6  
(187.2)  
7.3  
(208)  
8.1  
(228.8)  
Ounces  
(Grams)  
Weight  
PRODUCT GRADE TEMPERATURES  
Parameter  
Storage  
Operating  
-10 to + 85  
-25 to + 85  
-40 to + 85  
-55 to + 85  
Units  
°C  
Notes  
E
C
I
-20 to +100  
-40 to +100  
-55 to +100  
-65 to +100  
Overtemperature shutdown  
95°C typical (recycle power  
to restart)  
°C  
°C  
M
°C  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
VI-200 DC-DC Converters 50 to 200 Watts  
Rev. 3.1  
Page 3 of 5  
Set your site on VICOR at vicorpower.com  
MECHANICAL DRAWING  
4.60  
(116,8)  
Standard  
0.080 (2,0) Dia (2) places  
Solder plate over copper alloy Matte tin over copper alloy  
RoHS  
3.60  
.50  
(12,7)  
0.080 (2,0) Dia (2) places  
(91,4)  
1.80  
(45,7)  
.30 .015  
(7,6) (0,38)  
Pin # Function  
1
+In  
2
3
4
5
6*  
7*  
8*  
9
Gate In  
Gate Out  
-In  
+Out  
+Sense  
Trim  
4
3
9
8
7
6
2.10  
(53,3)  
1.40  
VI-200  
(35,6)  
(25,4)  
1.00  
.70  
2
1
(17,8)  
(10,2)  
.40  
5
.35 .015  
(8,9) (0,38)  
-Sense  
-Out  
* Do not connect on booster modules  
FULL R  
.15  
(3,8)  
Standard  
.040 (1,0) Dia (7) places  
RoHS  
.15  
(3,8)  
Product ID  
this surface  
.040 (1,0) Dia (7) places  
Solder plate over copper alloy Matte tin over copper alloy  
2.40  
(61,0)  
.30  
(7,6) Min  
4.20  
(106,7)  
1.75  
.22  
(5,6) MIN  
Max.  
(44,5)  
.50  
(12,7)  
+.030 (0,76)  
-.000 (0)  
.01  
.12  
(3,0)  
Aluminum Base  
PACKAGING OPTIONS  
SlimMod  
FinMod  
MegaMod  
Chassis mount alternatives, one, two,  
or three outputs: up to 600 W  
Flangeless package with integral heat sink  
Flangeless package  
1 up – 4.9¨ x 2.5¨ x 0.62¨ (124,4 x 63,5 x 15,7 mm)  
2 up – 4.9¨ x 4.9¨ x 0.62¨ (124,4 x 124,4 x 15,7 mm)  
3 up – 4.9¨ x 7.3¨ x 0.62¨ (124,4 x 185,4 x 15,7 mm)  
Longitudinal, 0.25"(6.35 mm) fins — add suffix “F1”  
Longitudinal, 0.50"(12.7 mm) fins — add suffix “F2”  
4.60"L x 1.80"W x 0.50"H  
(116,8 x 45,7 x 12,7 mm)  
BusMod  
To order the SlimMod configuration add the suffix S” to  
the standard module part number.  
Qty (2) grounding clips are included with each SlimMod  
P/N 32187  
Transverse, 0.25"(6.35 mm) fins — add suffix “F3”  
Transverse, 0.50"(12.7 mm) fins — add suffix “F4”  
4.60"L x 2.40"W x 1.08"H  
(116,8 x 61,0 x 27,4 mm)  
Available with longitudinal or transverse fins of 0.25"(6.35  
mm) or 0.50"(12.7 mm) height. Add the appropriate suf-  
fix to the module part number.  
To order the BusMod fully assembled, add suffix “–B1”  
to the standard module part number.  
Qty (4) grounding clips are included with each FinMod  
F1, F2 P/N 32185  
F3, F4 P/N 32186  
To order the BusMod separately:  
Full-sized BusMod — P/N 06322  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
VI-200 DC-DC Converters 50 to 200 Watts  
Rev. 3.1  
Page 4 of 5  
Set your site on VICOR at vicorpower.com  
Warranty  
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal  
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance.  
Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only.  
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,  
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE.  
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the  
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned  
without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the  
factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.  
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed  
for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function,  
or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it con-  
vey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its compo-  
nents in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and  
Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor  
against all damages.  
Vicor’s comprehensive line of power solutions includes high density AC-DC  
and DC-DC modules and accessory components, fully configurable AC-DC  
and DC-DC power supplies, and complete custom power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its  
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunc-  
tion could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon  
request.  
Specifications are subject to change without notice.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent  
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual  
Property Department.  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
Fax: 978-475-6715  
email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
VI-200 DC-DC Converters 50 to 200 Watts  
Rev. 3.1  
11/10  
Set your site on VICOR at vicorpower.com  

相关型号:

VI-27V-CW

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CW-F1

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CW-F2

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CW-S

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CX

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CX-F2

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CX-S

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CY

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, MODULE-9

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CY-B1

DC-DC Regulated Power Supply Module, 50W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CY-F1

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CY-F2

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR

VI-27V-CY-F3

CONVERTER MOD DC/DC 5.8V 50W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VICOR