Features  
Product Highlights  
Isolated output  
The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of “zero-  
current-switching” component-level DC-DC converters.  
3
Up to 50 W/in  
cURus, cTÜVus  
Up to 90% efficiency  
Size: 4.6" x 2.4" x 0.5"  
(116,8 x 61,0 x 12,7mm)  
Remote sense and current limit  
OVP, thermal shutdown  
Logic disable  
Operating at frequencies up to 2 MHz, VI-200 family converters offer exceptional  
power density, efficiency, noise performance, reliability and ease of use. Booster mod-  
ules (VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power  
output requirements. One or more boosters may be used to create synchronous arrays  
capable of supplying several kilowatts of output power.  
Wide range output adjust  
Compatible power booster modules  
ZCS power architecture  
Low noise FM control  
CE Marked  
The flexibility of Vicor’s power components is also available in half-size, half-power  
VI-J00 MiniMods.  
RoHS compliant (VE-200)  
Part Numbering  
VI  
2
6
1
C
W
Family  
VI = Non-RoHS 2 =200  
VE = RoHS  
Series  
Input  
Output  
M = 10 V  
1 = 12 V  
P = 13.8 V H = 52 V  
2 = 15 V F = 72 V  
Grade  
Power  
0= 12 V N =48 V  
V= 24 V 4 = 72 V  
1= 24 V T = 110 V  
Z = 2 V  
Y = 3.3 V  
0 = 5 V  
K = 40 V  
4 = 48 V  
E = –10 to 85°C  
C = –25 to 85°C  
I = 40 to 85°C  
≥ 5 V  
< 5 V  
B =Booster  
U = 200 W  
V = 150 W  
U = 40 A  
V = 30 A  
W= 24 V  
2= 36 V  
3= 48 V  
5 = 150 V  
6 = 300 V  
7 = 150/300 V  
X = 5.2 V  
M = –55 to 85°C W = 100 W W = 20 A  
Note: For additional  
packaging options,  
please see page 5.  
W = 5.5 V N = 18.5 V D = 85 V  
X = 75 W  
Y = 50 W  
X = 15 A  
Y = 10 A  
V = 5.8 V  
T = 6.5 V  
R = 7.5 V  
3 = 24 V  
L = 28 V  
J = 36 V  
B = 95 V  
VI-200 DC-DC Converters  
Page 1 of 6  
Rev 3.5  
vicorpower.com  
800 927.9474  
04/2014  
VI-200, VE-200  
Maximum Power Available for VI-2xx-xx[a]  
Input  
Output  
Vout Designators  
Low Line  
Voltage  
Vin  
Transient[b]  
2
Z
3.3  
Y
5
0
5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36 40 48 52 72 85 95  
75%  
Designators  
Nom. (Range)  
Max Power  
X
X
Y
U
V
W
U
U
U
V
V
Y
U
W
V
X
Y
U
V
W
U
U
U
V
V
Y
U
T
R
M
1
P
2
N
3
X
X
U
V
W
U
U
U
V
U
W
U
L
X
X
U
V
W
U
U
U
V
U
W
U
J
X
X
U
V
W
U
U
U
V
U
W
U
K
X
X
U
V
W
U
U
U
V
U
W
U
4
X
X
U
V
W
U
U
U
V
U
W
U
H
X
F
X
D
X
B
X
12 (10-20)  
24 (10-36)  
24 (21-32)  
24 (18-36)  
36 (21-56)  
n/a  
n/a  
18  
n/a  
18  
36  
n/a  
45  
22  
n/a  
36  
n/a  
60  
0
V
1
W
2
3
N
4
X
--  
U
V
W
U
V
U
V
U
W
U
X
X
U
V
V
U
U
U
V
U
W
U
X
Y
U
V
W
U
U
U
V
V
X
U
X
Y
U
V
W
U
U
U
V
X
Y
V
W
W
U
U
V
X
X
V
X
X
U
V
W
U
U
U
V
U
W
U
X
X
U
V
W
U
U
U
V
U
W
U
X
X
U
V
W
U
U
U
V
U
W
U
X
X
U
V
W
U
U
U
V
U
W
U
X
X
U
V
W
U
U
U
V
U
W
U
-- -- -- --  
U
V
U
V
U
V
U
V
W
W
U
U
V
W
V
W
W
U
U
U
V
U
W
U
-- -- --  
48 (42-60)  
48 (36-76)  
72  
U
U
U
V
U
U
U
U
-- --  
U
U
U
U
n/a  
110  
n/a  
215  
n/a  
425  
72 (55-100)  
110 (66-160)  
150 (100-200)  
150 (100-375)  
300 (200-400)  
n/a  
85[c]  
n/a  
170[d]  
T
5
7
W
V
W
V
Y
U
U
-- -- --  
U
6
V
V
U
U
[a] For additional output power, “booster” modules are available. (VI-Bxx-xx)  
[c] 15 Vout, 200 W models are limited to 90 Vdc  
[b] Transient voltage for 1 second.  
[d] 15 Vout, 200 W models are limited to 185 Vdc  
CONVERTER SPECIFICATIONS  
(typical at T = 25°C, nominal line and 75% load, unless otherwise specified)  
BP  
INPUT SPECIFICATIONS  
VI-200 E-Grade  
Typ  
VI-200 C-, I-, M-Grade  
Parameter  
Min  
Max  
Min  
Typ  
Max  
Units  
Test Conditions  
Inrush charge  
120x10-6  
120x10-6  
200x10-6  
Coulombs Nominal line  
Input reflected  
10%  
10%  
I
IN  
Nominal line, full load  
120 Hz, nominal line  
2400 Hz, nominal line  
ripple current – pp  
Vin  
Vin  
Input ripple rejection  
dB  
dB  
25+20Log  
30+20Log  
(
)
(
(
)
Vout  
Vout  
Vin  
20+20Log  
1.35  
)
Vout  
No load power dissipation  
1.35  
2
2
Watts  
VI-200 DC-DC Converters  
Page 2 of 6  
Rev 3.5  
vicorpower.com  
800 927.9474  
04/2014  
VI-200, VE-200  
CONVERTER SPECIFICATIONS (cont.)  
OUTPUT CHARACTERISTICS  
VI-200 E-Grade  
VI-200 C-, I-, M-Grade  
Parameter  
Min  
Typ  
Max  
2%  
Min  
Typ  
0.5%  
0.05%  
0.2%  
0.01  
Max  
Units  
VNOM  
VNOM  
Test Conditions  
Setpoint accuracy  
Load/line regulation  
Load/line regulation  
Output temperature drift  
Long term drift  
1%  
1%  
0.5%  
1%  
0.2%  
0.5%  
0.02  
LL to HL, 10% to Full Load  
LL to HL, No Load to 10%  
Over rated temp.  
VNOM  
0.02  
0.02  
% / °C  
0.02  
%/1K hours  
Output ripple – pp:  
2 V, 3.3 V  
150  
5%  
3%  
60  
2%  
100  
3%  
mV  
20 MHz bandwidth  
20 MHz bandwidth  
20 MHz bandwidth  
5 V  
VNOM  
VNOM  
10 – 95 V  
0.75%  
1.5%  
Trim range[a]  
50%  
0.5  
110%  
50%  
0.5  
110%  
VNOM  
Total remote  
Volts  
0.25 V max. neg. leg  
sense compensation  
OVP set point  
125%[b]  
115%  
105%  
20%  
125%[b]  
135%  
125%  
130%  
VNOM  
Ifull load  
Ifull load  
Recycle power  
Current limit  
Short circuit current[c]  
105%  
20%  
135%  
140%  
Automatic restart  
Automatic restart  
[a]  
10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range 10%. Consult factory for wider trim range.  
3.3 V output trim range 2.20 to 3.63 V, 95 V output –50 + 0% trim range.  
131% nominal for booster modules.  
[b]  
[c]  
Output voltages of 3.3 V or 5 V incorporate foldback current limiting; For output voltages from 5.2 V to 7.5 V consult factory; All other outputs provide constant current limiting.  
CONTROL PIN SPECIFICATIONS  
VI-200 E-Grade  
Typ  
VI-200 C-, I-, M-Grade  
Parameter  
Min  
Max  
Min  
Typ  
50  
Max  
Units  
Ohms  
Ohms  
Volts  
Volts  
mA  
Test Conditions  
Gate out impedance  
Gate in impedance  
50  
1000  
6
1000  
6
Gate in open circuit voltage  
Gate in low threshold  
Gate in low current  
Use open collector  
0.65  
0.95  
0.65  
0.95  
6
6
Power sharing accuracy  
1.05  
1.05  
VI-200 DC-DC Converters  
Page 3 of 6  
Rev 3.5  
vicorpower.com  
800 927.9474  
04/2014  
VI-200, VE-200  
CONVERTER SPECIFICATIONS (cont.)  
DIELECTRIC WITHSTAND CHARACTERISTICS  
VI-200 E-Grade  
VI-200 C-, I-, M-Grade  
Typ Max  
Parameter  
Min  
3,000  
500  
Typ  
Max  
Min  
3,000  
500  
Units  
VRMS  
VRMS  
VRMS  
Test Conditions  
Input to output  
Output to baseplate  
Input to baseplate  
Baseplate earthed  
1,500  
1,500  
THERMAL CHARACTERISTICS  
VI-200 E-Grade  
Typ  
VI-200 C-, I-, M-Grade  
Parameter  
Min  
Max  
Min  
Typ  
Max  
Units  
Test Conditions  
Efficiency  
78 – 88%  
80 – 90%  
Baseplate to sink  
0.07  
0.07  
°C/Watt  
°C  
With Vicor P/N 20266  
thermal impedance  
Thermal shutdown[d]  
(Drivers only)  
Cool and recycle power  
to restart  
90  
95  
105  
90  
95  
105  
[d]  
No overtemp protection in booster modules.  
MECHANICAL SPECIFICATIONS  
VI-200 E-, C-Grade  
VI-200 I-, M-Grade  
Typ  
Parameter  
Min  
Typ  
Max  
Min  
Max  
Units  
Test Conditions  
5.7  
6.3  
6.9  
6.6  
7.3  
8.1  
Ounces  
(Grams)  
Weight  
(160.2)  
(178)  
(195.8)  
(187.2)  
(208)  
(228.8)  
PRODUCT GRADE TEMPERATURES  
Parameter  
Storage  
Operating  
-10 to + 85  
-25 to + 85  
-40 to + 85  
-55 to + 85  
Units  
°C  
Notes  
E
C
I
-20 to +100  
-40 to +100  
-55 to +100  
-65 to +100  
Overtemperature shutdown  
95°C typical (recycle power  
to restart)  
°C  
°C  
M
°C  
VI-200 DC-DC Converters  
Page 4 of 6  
Rev 3.5  
vicorpower.com  
800 927.9474  
04/2014  
VI-200, VE-200  
MECHANICAL DRAWING  
4.60  
(116,8)  
Standard  
RoHS  
3.60  
.50  
0.080 (2,0) Dia (2) places  
0.080 (2,0) Dia (2) places  
(91,4)  
(12,7)  
1.80  
Solder plate over copper alloy Matte tin over copper alloy  
(45,7)  
.30 .015  
(7,6) (0,38)  
Pin # Function  
1
+In  
2
Gate In  
Gate Out  
-In  
4
3
9
3
4
5
6*  
7*  
8*  
9
8
7
6
2.10  
1.40  
+Out  
VI-200  
(35,6)  
1.00  
(53,3)  
.70  
(25,4)  
+Sense  
Trim  
-Sense  
-Out  
2
1
(17,8)  
.40  
(10,2)  
5
.35 .015  
(8,9) (0,38)  
* Do not connect on booster modules  
FULL R  
.15  
Standard  
RoHS  
.15  
(3,8)  
(3,8)  
Product ID  
this surface  
.040 (1,0) Dia (7) places  
.040 (1,0) Dia (7) places  
Solder plate over copper alloy Matte tin over copper alloy  
2.40  
(61,0)  
.30  
4.20  
1.75  
(7,6) Min  
.22  
(106,7)  
Max.  
(44,5)  
(5,6) MIN  
.50  
(12,7)  
+.030 (0,76)  
-.000 (0)  
.01  
.12  
Aluminum Base  
(3,0)  
PACKAGING OPTIONS  
SlimMod  
FinMod  
MegaMod  
Chassis mount alternatives, one, two,  
or three outputs: up to 600 W  
Flangeless package with integral heat sink  
Flangeless package  
1 up – 4.9¨ x 2.5¨ x 0.62¨ (124,4 x 63,5 x 15,7 mm)  
2 up – 4.9¨ x 4.9¨ x 0.62¨ (124,4 x 124,4 x 15,7 mm)  
3 up – 4.9¨ x 7.3¨ x 0.62¨ (124,4 x 185,4 x 15,7 mm)  
Longitudinal, 0.25"(6.35 mm) fins — add suffix “F1”  
Longitudinal, 0.50"(12.7 mm) fins — add suffix “F2”  
4.60"L x 1.80"W x 0.50"H  
(116,8 x 45,7 x 12,7 mm)  
BusMod  
To order the SlimMod configuration add the suffix S” to  
the standard module part number.  
Qty (2) grounding clips are included with each SlimMod  
P/N 32187  
Transverse, 0.25"(6.35 mm) fins — add suffix “F3”  
Transverse, 0.50"(12.7 mm) fins — add suffix “F4”  
4.60"L x 2.40"W x 1.08"H  
(116,8 x 61,0 x 27,4 mm)  
Available with longitudinal or transverse fins of  
0.25"(6.35 mm) or 0.50"(12.7 mm) height. Add the  
appropriate suffix to the module part number.  
To order the BusMod fully assembled, add suffix “–B1”  
to the standard module part number.  
To order the BusMod separately:  
Qty (4) grounding clips are included with each FinMod  
F1, F2 P/N 32185  
Full-sized BusMod — P/N 06322  
F3, F4 P/N 32186  
See BusMod Mechanical Drawings for more details.  
VI-200 DC-DC Converters  
Page 5 of 6  
Rev 3.5  
vicorpower.com  
800 927.9474  
04/2014  
VI-200, VE-200  
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and  
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom  
power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no  
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make  
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked  
and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality con-  
trols are used to the extent Vicor deems necessary to support Vicors product warranty. Except where mandated by government requirements,  
testing of all parameters of each product is not necessarily performed.  
Specifications are subject to change without notice.  
Vicor’s Standard Terms and Conditions  
All sales are subject to Vicors Standard Terms and Conditions of Sale, which are available on Vicors webpage or upon request.  
Product Warranty  
In Vicors standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the  
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment  
and is not transferable.  
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DIS-  
CLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)  
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FIT-  
NESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MAT-  
TER.  
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be  
liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and  
assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor prod-  
ucts and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing  
and operating safeguards.  
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact  
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be  
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the  
product was defective within the terms of this warranty.  
Life Support Policy  
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS  
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support  
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform  
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to  
the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause  
the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor  
products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the prod-  
ucts described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is  
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
Fax: 978-475-6715  
email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
VI-200 DC-DC Converters  
Page 6 of 6  
Rev 3.5  
vicorpower.com  
800 927.9474  
04/2014  

相关型号:

VI-2NV-MX-B1

CONVERTER MOD DC/DC 5.8V 75W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR

VI-2NV-MX-F1

CONVERTER MOD DC/DC 5.8V 75W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR

VI-2NV-MX-F2

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR

VI-2NV-MX-F3

DC-DC Regulated Power Supply Module, 75W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR

VI-2NV-MX-F4

CONVERTER MOD DC/DC 5.8V 75W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR

VI-2NV-MX-S

CONVERTER MOD DC/DC 5.8V 75W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR

VI-2NV-MY

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR

VI-2NV-MY-B1

DC-DC Regulated Power Supply Module, 50W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR

VI-2NV-MY-F1

CONVERTER MOD DC/DC 5.8V 50W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR

VI-2NV-MY-F2

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VICOR