VI-CMUG-IQ [VICOR]
AC-DC Power Factor Correction Module, 1 Output, 575W, Hybrid;型号: | VI-CMUG-IQ |
厂家: | VICOR CORPORATION |
描述: | AC-DC Power Factor Correction Module, 1 Output, 575W, Hybrid |
文件: | 总7页 (文件大小:493K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Data Sheet
TM
PFC FlatPAC
575 W Power Factor Corrected
AC-DC Power Supply
Features
• Inputs: 85 – 264 Vac universal
• Meets FCC Part 15, EN55022,
Class A conducted emissions
• 75-85% efficiency
Actual size:
• cTÜVvs, CE marked
9.25 x 4.9 x 1.37 in
234,8 x 124,4 x 34,8 mm
• Remote sense and current limit
• 8-60 mS ride-through time
• OVP and thermal shutdown
• Up to 575 W output
PFC FlatPAC Selection Chart
[a]
V I -CMU -
-
[a]E for RoHS compliant
Product Highlights
The PFC FlatPAC uses Vicor’s field-proven
VI-HAM and Maxi DC-DC converters to
deliver up to 575 Watts of clean, reliable
power. The PFC FlatPAC is a single-output
power supply available with standard output
voltages from 3.3 – 54 Vdc.
Output Voltage
Output Power/Current Vout
V
5 V
V
12 V
OUT ≥
OUT ≤
Q = 80 A
Y = 3.3 V
0 = 5.0 V
1 = 12 V
2 = 15 V
3 = 24 V
L = 28 V
M = 575 W
J = 36 V
4 = 48 V
G = 54 V
It operates from an input of 85 – 264 Vac,
includes active power factor correction (0.99
power factor), and meets EN61000-3-2 har-
monic current limits. Internal filtering pro-
vides compliance to EN55022-A
conducted EMI. It is available in Vicor’s
low profile 1.37" (34,8 mm) FlatPAC
chassis, in either finned or conduction-
cooled (CC) versions.
Product Grade Temps. (°C)
Options
E = 0 to +85 case
C = 0 to +85 case
CC = Conduction cooled
I
= –30 to +85 case
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
PFC FlatPAC
Rev. 1.2
Page 1 of 7
Set your site on VICOR at vicorpower.com
FLATPAC SPECIFICATIONS
(typical at = 25°C, 120/240 Vac line and 75% load, unless otherwise specified)
INPUT CHARACTERISTICS
Parameter
AC line input
Universal
Min
Typ
Max
Unit
Note
85
264
Vac
Unit will operate at 400 Hz but may not meet
Power Factor or Total Harmonic Distortion specs.
Efficiency may be reduced.
Line frequency
47 – 63
Hz
Inrush current
230 Vac operation, full load
Ride-through time (full load)
85 – 264 Vac
20
60
A
8
ms
Dielectric withstand
Primary to chassis GND
Primary to secondary
Secondary to chassis GND
Power Factor
2,121
4,242
707
Vdc
Vdc
Vdc
0.99
7.5%
8.5%
Sinusuidal, 115 Vac, full load
Sinusuidal, 230 Vac, full load
Total Harmonic Distortion
OUTPUT CHARACTERISTICS (see datasheet for V375 Maxi family for additional info)
E-Grade
Typ
C-, I-Grade
Typ
Min
Max
Min
Max
Units
Note
Set point accuracy
Line regulation
low line
1%
2%
0.5%
1%
V
NOM
0.5%
0.5%
0.02%
0.02%
0.2%
0.2%
V
V
85 – 264 Vac, 0 – 350 W
115 – 264 Vac, 0 – 575 W
NOM
NOM
nominal to high line
Load regulation
low line
1%
1%
0.2%
0.2%
0.01
0.02
0.5%
0.5%
0.02
V
V
85 – 264 Vac, 0 – 350 W
115 – 264 Vac, 0 – 575 W
Over rated temperature
NOM
NOM
nominal to high line
Output temperature drift
Long term drift
Output ripple
3.3 V
0.02
0.02
%/°C
%/1 k hours
150
5%
3%
120
120
2%
150
150
3%
mVp-p
mVp-p
p-p
20 MHz bandwidth
20 MHz bandwidth
20 MHz bandwidth
5 V
12-54 V
See vicorpower.com for
trim calculator
Output voltage trimming
10%
110%
0.5
10%
110%
Total remote sense compensation
OVP set point
0.5
Volts
0.25 V max. neg. leg
Recycle power
125%
115%
102%
70%
120%
125%
135%
135%
V
NOM
Current limit
102%
70%
135%
140%
I
Automatic restart
NOM
Short circuit current
I
NOM
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
PFC FlatPAC
Rev. 1.2
Page 2 of 7
Set your site on VICOR at vicorpower.com
FLATPAC SPECIFICATIONS
(typical at = 25°C, 120/240 Vac line and 75% load, unless otherwise specified)
THERMAL CHARACTERISTICS
E-Grade
Typ
C-, I-Grade
Typ
Min
Max
Min
Max
Units
Note
Efficiency
70 – 80%
75 – 85%
Cool and recycle
power to restart
Shut down temp. — case
90
95
105
85
90
95
105
85
°C
°C
Operating temp. — case
See Thermal Curves
MECHANICAL SPECIFICATIONS
Parameter
Weight
Min
Typ
44.8 (1304)
Max
Unit
Note
Ounces (Grams)
SAFETY AGENCY APPROVALS
cTÜVus
CE
UL 60950-1, CSA 60950-1, EN60950-1, IEC 60950-1
Low voltage directive 73/23/EEC
EVIRONMENTAL CHARACTERISTICS/PRODUCT GRADE DESIGNATORS
Parameter
Min
Typ
Max
Unit
°C
Note
-20 to +100
-55 to +100
0 to +85
C-Grade and E-Grade
Storage temperature
°C
I-Grade
°C
C-Grade and E-Grade
I-Grade
Operating temperature (case)
-30 to +85
°C
EMI / EMC CHARACTERISTICS (Performed on selected samples representative of the PFC FlatPAC product family.)
Parameter
Conducted emissions
Min
Typ
Max
Unit
Note
EN 55022:1998, CISPR 22, Class A
EN 55022:1998, CISPR22, Class B
EN 61000-3-2:2000
Radiated emissions
Harmonic current emissions
Voltage fluctuations and flicker
Electrostatic discharge
EN 61000-3-3:1995
EN 61000-4-2, level 4, 8 kv contact, 15 kv air discharge
EN 61000-4-3, 80 MHz to 2.0 GHz, 10 v/m
EN 61000-4-4, Level 3; 500 v, 1 kv and 2 kv
EN 61000-4-5, Level 3; 500 v, 1 kv, 1.5 kv and 2 kv
EN 61000-4-6, Level 3; 150 kHZ to 80 MHz, 10 vrms
EN 61000-4-8, Level 4; 30 A/m, continuous field
EN61000-4-11
RF radiated immunity, E-field
Electrical fast transients/burst
Power line surge immunity
RF conducted immunity
Power frequency H-field Immunity
Voltage dips and interrupts
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
PFC FlatPAC
Rev. 1.2
Page 3 of 7
Set your site on VICOR at vicorpower.com
Note: All temperature derating performed at 120 Vac input
200 LFM
400 LFM
600 LFM
800 LFM
1000 LFM
FREE AIR
600
500
400
300
200
100
0
400
350
300
250
200
150
100
50
0
0
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (°C)
Ambient Temperature (°C)
Figure 1 — Output power derating vs. temperature, Vout ≥ 12 V
Figure 2 — Output power derating vs. temperature, Vout = 5 V
264
240
216
192
168
144
120
96
600
575
550
525
500
475
450
425
400
375
350
72
48
24
0
0
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
85
105 125 145 165 185 205 225 245 265
Ambient Temperature (°C)
Vin (Vrms)
Figure 3 — Output power derating vs. temperature, Vout = 3.3 V
Figure 4 — PFC FlatPAC Output Power Vs. Input Voltage
Inputs
7 AC IN L1
Terminals for
8 AC IN L2/N
9 CHASSIS GND
#16-12 AWG wire
Outputs
L1
10 +OUT (#10-32 Stud)
11 +OUT
AC Mains
Output connector,
L2/N
12 +SENSE (VTRIM*)
13 TRIM (ITRIM*)
14 –SENSE (IMON*)
15 –OUT
Amp P/N 644486-5;
mating connector,
MTA-100 IDC Series
Earth Ground
GND
16 –OUT (#10-32 Stud)
Note: Pins 1-6 connected to chassis GND (Not Used).
Figure 5 — AC input connections
Figure 6 — Electrical connections
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
PFC FlatPAC
Rev. 1.2
Page 4 of 7
Set your site on VICOR at vicorpower.com
600
500
400
300
200
100
0
600
550
500
450
400
350
300
Cold Plate
Temp (°C)
80
60
70
50
85
110
135
160
185
210
235
260
20 25 30 35 40 45 50 55 60 65 70 75 80 85
Input Voltage (Vac)
Ambient Temperature (°C)
Figure 7 — Power de-rating conduction cooled option
Figure 8 — Output power start-up de-rating @ –30° C
(I-Grade only). 5 minute warm up required before full power (see
Figure 4) is available.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
PFC FlatPAC
Rev. 1.2
Page 5 of 7
Set your site on VICOR at vicorpower.com
MOUNTING HOLE
ø 0.15 0.01 THRU
5 PLACES
+
10
16
4.562 0.010
4.960 0.030
(115,87 0,25ꢀ
(125,98 0,76ꢀ
10
11
12
13
14
15
16
3.83
(97,16ꢀ
2.281 0.010
7
8
9
(57,94 0,25ꢀ
1.17
(29,72ꢀ
–
0.199 0.010
(5,05 0,25ꢀ
0.18
6.00
(4,57ꢀ
(152,4ꢀ
1.375 0.020
(34,91 0,51)
1.11
( 28,19)
0.50
(12,57)
9.245 0.030
(234,82 0,76)
Figure 9a — Mechanical drawings; convection cooled.
Figure b — Mechanical drawings; conduction cooled.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
PFC FlatPAC
Rev. 1.2
Page 6 of 7
Set your site on VICOR at vicorpower.com
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or mainte-
nance. Vicor shall not be liable for collateral or consequential damage.
This warranty is extended to the original purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this
warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions.
Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning
the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no
responsibility is assumed for inaccuracies. Vicor reserves the right to make changes to any products without
further notice to improve reliability, function, or design. Vicor does not assume any liability arising out of the
application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others.
Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction
may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support appli-
cations assumes all risks of such use and indemnifies Vicor against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunc-
tion could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon re-
quest.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent ap-
plications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Vicor Express: vicorexp@vicr.com
Technical Support: apps@vicr.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
PFC FlatPAC
Rev. 1.2
09/08
Set your site on VICOR at vicorpower.com