VI-LUL-EW-CC [VICOR]
AC-DC Regulated Power Supply Module, 100W;型号: | VI-LUL-EW-CC |
厂家: | VICOR CORPORATION |
描述: | AC-DC Regulated Power Supply Module, 100W 输出元件 |
文件: | 总6页 (文件大小:491K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Data Sheet
FlatPACTM
50 to 600 Watts Autoranging
AC-DC Switchers
Features
• RoHS compliant (VE versions)
• Microcontroller architecture
• Inputs: 115/230 Vac autoranging
• Meets FCC Part 15, EN55022,
Class B conducted emissions
• 80 – 90% efficiency
Configuration Chart
• Any output: 1 to 95 Vdc
• Module enable/disable
0
1
1
E U U U
-
Typical Model: VI-RU
-
Input
Output
Input Characteristics
90–132/180–264 Vac
U = Autoranging
(except LU series)
115/230 Vac
1: 5 Vdc at 200 W
2: 12 Vdc at 200 W
3: 12 Vdc at 200 W
• UL, TÜV, CE marked
• Remote sense and current limit
• BUS OK and AC OK
(except LU series)
Substitute VE– for VI– for RoHS compliant versions
• 40 ms ride-through time
• OVP and thermal shutdown
• 1 output; up to 200 W
Configuration
Single Output
Total
# of
Power
Converters
Dimensions
• 1 or 2 outputs; up to 400 W
• 1, 2, or 3 outputs; up to 600 W
9.25" x 2.5" x 1.37"
VI-LU
VI-MU
VI-NU
-
50 – 200 W
200 – 400 W
300 – 600 W
1
2
3
(234,8 x 124,5 x 34,8 mm)
9.25" x 4.9" x 1.37"
-
(234,8 x 124,5 x 34,8 mm)
9.25" x 7.3" x 1.37"
Product Highlights
-
(234,8 x 185,4 x 34,8 mm)
If you’re looking for the convenience
of a complete, low profile, agency-
approved switching power supply, look
no further. The FlatPAC combines Vicor’s
workhorse VI-200 family of DC-DC
converters with a modular package and
front-end subassembly to provide from
50 to 600 W of output power from one
to three outputs.
Dual Output
VI-PU
9.25" x 4.9" x 1.37"
-
100 – 400 W
150 – 600 W
2
3
(234,8 x 124,5 x 34,8 mm)
9.25" x 7.3" x 1.37"
VI-QU
-
(234,8 x 185,4 x 34,8 mm)
Triple Output
VI-RU
9.25" x 7.3" 1.37"
-
150 – 600 W
3
(234,8 x 185,4 x 34,8 mm)
Output Voltage
A flat plate heat sink for use in conduction
cooled applications may be specified as an
alternate to the standard finned version by
adding “CC” to the end of the model
number.
Z = 2 V
W = 5.5 V
V = 5.8 V
T = 6.5 V
R = 7.5 V
M = 10 V
1 = 12 V
P = 13.8 V
2 = 15 V
N = 18.5 V
3 = 24 V
L = 28 V
J = 36 V
K = 40 V
4 = 48 V
H = 52 V
F = 72 V
D = 85 V
B = 95 V
Y = 3.3 V
0 = 5 V
X = 5.2 V
Vicor’s FlatPAC is also available with a
current controlled output using BatMod
converter modules of 12, 24, or 48 Vdc
outputs. This option is specified by
appending “BM” or “BC” (for conduction
cooled versions) to the end of the FlatPAC
model number.
Product Grade Temps. °C
Output Power/Current
Grade
Operating
Storage
–20 to +100
–20 to +100
–55 to +100
OUT
OUT
V
Y
X
≥5 V
V
Y
X
< 5 V
E =
0 to +85
= 50 W
= 10 A
C =
0 to +85
= 75 W
= 15 A
I
=
–30 to +85
W = 100 W
W = 20 A
V
U
= 150 W
= 200 W
V
U
= 30 A
= 40 A
Temperatures apply to product case.
Mixing VI-200 and BatMods in a single
FlatPAC is not permissible.
Output Power/Current
V
OUT ≥5 V
V
OUT < 5 V
Output Power/Current
The FlatPAC’s contemporary design
allows us to configure your order quickly
and provide rapid turnaround on standard
models. It is truly a complete power
solution, enabling you to spend more time
designing your system and less time
worrying about how to power it.
W= 100 W
V = 150 W
U = 200 W
S = 300 W
Q = 400 W
W= 20 A
V = 30 A
U = 40 A
S = 60 A
Q = 80 A
V
OUT ≥5 V
V
OUT < 5 V
S = 60 A
P = 90 A
M = 120 A
S = 300 W
P = 450 W
M = 600 W
Options
BC = BatMod/Conduction Cooled
BM = BatMod
FlatPAC
CC = Conduction Cooled
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Rev. 1.5
Page 1 of 6
Set your site on VICOR at vicorpower.com
SPECIFICATIONS
(typical at 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
AC line input
Autoranging
90 – 132/180 – 264
Vac
47 – 63
Hz
Hz
(C-Grade and E-Grade)
(I-Grade)
Line frequency
47 – 440
Inrush current: 115 Vac operation:
1 converter
16
23
39
A
A
A
@ peak line
@ peak line
@ peak line
2 converters
3 converters
Inrush current: 230 Vac operation
1 converter
32
47
78
A
A
A
@ peak line
@ peak line
@ peak line
2 converters
3 converters
Ride-through time (full load)
90/180 Vac low line
5
ms
ms
minimum
minimum
115/230 Vac nominal line
40
AC fail warning time
5
ms
minimum (low line, full load)
@ 1 mA (1.5 mA max.)
@ 30 mA
AC and BUS OK (2 and 3 converter models only)
Off state – Vce
70
V
V
On state – Vcesat
0.4
Module disable(2 and 3 converter models only, optically isolated LED input)
Continuous forward current
Forward voltage
1 – 30
mA
V
1.65
Dielectric withstand
Primary to chassis GND
Primary to secondary
Secondary to chassis GND
2,121
4,242
707
Vdc
Vdc
Vdc
OUTPUT SPECIFICATIONS
E-Grade
Typ
C-, I-Grade
Parameter
Min
Max
Min
Typ
Max
Unit
Notes
Set point accuracy
Load/line regulation
1%
2%
0.5%
1%
V
NOM
0.5%
1%
0.05%
0.2%
0.2%
0.5%
V
VNNOOMM
LL to HL, 10% to Full Load
LL to HL, No Load to full load
Output temperature drift
Long term drift
0.02
0.02
0.01
0.02
0.02
%/°C
Over rated temperature
%/1 k hours
Output ripple
2 V
150 mV
5%
60 mV
2%
100 mV
3%
p-p
p-p
p-p
20 MHz bandwidth
20 MHz bandwidth
20 MHz bandwidth
5 V
10 – 48 V
3%
0.75%
1.5%
Output voltage trimming1
50%
0.5
110%
50%
110%
Total remote sense
compensation
0.5
Volts
0.25 V max. neg. leg
Recycle power
OVP set point
125%
115%
105%
20%
125%
135%
125%
130%
V
NOM
Current limit
105%
20%
135%
140%
I
I
NOM
Automatic restart
Short circuit current2
NOM
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FlatPAC
Rev. 1.5
Page 2 of 6
Set your site on VICOR at vicorpower.com
SPECIFICATIONS (CONT.)
THERMAL CHARACTERISTICS
E-Grade
Typ
C-, I- Grade
Typ
Parameter
Min
Max
Min
Max
Units
Test Conditions
Efficiency
78 – 88%
95
80 – 90%
95
@5 V and higher
Cool and recycle power
to restart
Shut down temp. — case
Operating temp. — case
90
105
85
90
105
85
°C
°C
See Thermal Curves
MECHANICAL SPECIFICATIONS
E-Grade
Typ
C-, I- Grade
Typ
Parameter
Min
Max
Min
Max
Units
Test Conditions
Weight3
22.4
(652)
22.4
(652)
Ounces
(Grams)
AGENCY APPROVALS
Safety Standards
Markings
Notes
UL1604, UL60950-1
UL / CSA / EN / IEC 60950-1
cURus
cTÜVus,
CE Mark
Low Voltage Directive (73/23/EEC)
EMI / EMC Characteristics (Performed on selected samples representative of the U Series FlatPac product family.)
Parameter
Notes
Conducted emissions, LISN
Radiated emissions, 10 meters
Electrostatic discharge
EN 55022 and FCC R&R, Part 15, Subpart B, Class B
EN 55022; 1998 and FCC R&R, Part 15, Subpart B, Class A
IEC 61000-4-2: 1995, Level 4; 8 kV Contact, 15 kV Air Discharge
IEC 61000-4-3: 1997; 80 MHz to 1.0 GHz, 3 V/M, CW
EN 61000-4-4: 1995, Level 3; 2 kV,
RF radiated immunity, E-field
Electrical fast transients/burst
Surge immunity
EN 61000-4-5: 1996 Class 3; 2 kV Line to Ground, 1 kV Line to Line
IEC 61000-4-6: 1996, class 3, 10 Vrms, 150 kHz to 80 MHz
RF conducted immunity
Power frequency magnetic
IEC 61000-4-8: 1994, 30 to 300 A/M, 50Hz
IEC 61000-4-11: 1994
field immunity
Voltage dips and interrupts
1
2
3
10 V, 12 V and 15 V outputs, trim range 10%. Consult factory for wider trim range.
Output voltages of 5 V or less incorporate foldback current limiting, outputs greater than 5 V incorporate straight line current limiting.
For MU, PU series, multiply value by 2; for NU, QU, RU series, multiply value by 3.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FlatPAC
Rev. 1.5
Page 3 of 6
Set your site on VICOR at vicorpower.com
THERMAL CURVES
FREE AIR
50 LFM
100 LFM
250 LFM
500 LFM
750 LFM
1000 LFM
5 V Output
200
175
150
125
100
75
600
525
450
375
300
225
150
75
400
350
300
250
200
150
100
50
50
25
0
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
Ambient Temperature (Deg. C)
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
LU Series
MU, PU Series
NU, QU, RU Series
10 to 48 V Output
200
175
150
125
100
75
400
350
300
250
200
150
100
50
600
525
450
375
300
225
150
75
50
25
0
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
Ambient Temperature (Deg. C)
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
LU Series
MU, PU Series
NU, QU, RU Series
APPLICATION CIRCUITS
VLINE > 90 (180)Vac
AC
Line
AC Line
Interrupted
AC-OK
BUS-OK
T0 T1
T2 T3
T4
Conditions: Full Load 90 (180)Vac, AC Line
Time Interval
T0-T1
Min
0
Typ
0.1
40
–
Max
1.0
–
Units
ms
Notes
MOD-DIS –
MOD-DIS +
AC-OK –
AC-OK +
BUS-OK –
BUS-OK +
Internal
Supervisory
Circuits
2-Up
and
3-Up
T2-T3
0
ms
Ride-through time
Hold-up time
T2-T4
5
–
ms
(Optocouplers)
T3-T4
5
–
–
ms
AC fail warning time
Power Up and Power Down Sequencing
L1
1-Up
AC Mains
L2/N
Earth Ground
GND
+ Vout
+O
R1
+S
Trim
–S
R2
10K
AC Mains Connections
Vout RTN
–O
Resistor Values for Trimming Standard Output Voltages
Nom. Output Voltage
5 V
0.953
90
12 V
15.8
90
15 V
22.1
90
24 V
41.2
90
28 V
48.7
90
48 V Trim Range
R1(kΩ)
90.9
+10%, -10%
R2(kΩ)
90
Output Trimming
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FlatPAC
Rev. 1.5
Page 4 of 6
Set your site on VICOR at vicorpower.com
MECHANICAL DRAWINGS
Inputs
STANDARD MODELS
1 MOD DIS–
Input connector,
2 MOD DIS+
Amp P/N 644488-6;
3 AC OK–
mating connector,
4 AC OK+
1.375 0.020
(34,91 0,51ꢀ
MTA-100 IDC Series
5 BUS OK–
1.11
( 28,19ꢀ
6 BUS OK+
7 AC IN L1
Terminals for
0.50
8 AC IN L2/N
#16-12 AWG wire
9 CHASSIS GND
(12,57ꢀ
9.245 0.030
(234,82 0,76ꢀ
Outputs
10 +OUT (#10-32 Stud)
11 +OUT
CONDUCTION COOLED MODELS “–CC”
Output connector,
12 +SENSE (VTRIM*)
Amp P/N 644486-5;
13 TRIM (ITRIM*)
mating connector,
14 –SENSE (IMON*)
MTA-100 IDC Series
15 –OUT
16 –OUT (#10-32 Stud)
*On FlatPACs with BatMODs only.
LU SERIES
MOUNTING HOLE
ø 0.15 0.01 THRU
4 PLACES
10
11
12
13
14
15
16
2.540 0.030
(64,52 0,76ꢀ
7
2.156 0.010
8
(54,76 0,25ꢀ
9
1.27
(32,26ꢀ
0.192 0.010
(4,88 0,25ꢀ
0.18
6.00
(4,57ꢀ
(152,4ꢀ
MU SERIES
PU SERIES
MOUNTING HOLE
ø 0.15 0.01 THRU
5 PLACES
+
10
10
11
12
13
14
15
16
4.562 0.010
(115,87 0,25ꢀ
4.960 0.030
(125,98 0,76ꢀ
16
10
11
12
13
14
15
16
10
11
12
13
14
15
3.83
(97,16ꢀ
2.281 0.010
(57,94 0,25ꢀ
7
8
9
1.17
16
–
(29,72ꢀ
0.199 0.010
(5,05 0,25ꢀ
0.18
6.00
(4,57ꢀ
(152,4ꢀ
NU SERIES
QU SERIES
RU SERIES
MOUNTING HOLE
ø 0.15 0.01 THRU
6 PLACES
+
–
+
10
10
11
12
13
14
15
16
10
11
12
13
14
15
16
7.380 0.030
(187,45 0,76ꢀ
1
2
3
4
5
6
7.000 0.010
(177,8 0,25ꢀ
16
10
10
10
11
12
13
14
15
16
4.710 0.010
(119,63 0,25ꢀ
5.48
(139,19ꢀ
16
16
7
8
9
+
–
10
11
12
13
14
15
10
11
12
13
14
15
16
10
11
12
13
14
15
16
2.290 0.010
(58,17 0,25ꢀ
1.93
(49,02ꢀ
16
–
0.190 0.010
(4,83 0,25ꢀ
0.18
(4,57ꢀ
6.00
(152,4ꢀ
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FlatPAC
Rev. 1.5
Page 5 of 6
Set your site on VICOR at vicorpower.com
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or
maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original
purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned
without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the
product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed
for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function,
or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it con-
vey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its compo-
nents in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and
Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor
against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or
malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available
upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FlatPAC
Rev. 1.5
11/08
Set your site on VICOR at vicorpower.com