VI-MC60-MVH1 [VICOR]

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10;
VI-MC60-MVH1
型号: VI-MC60-MVH1
厂家: VICOR CORPORATION    VICOR CORPORATION
描述:

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10

输出元件
文件: 总8页 (文件大小:704K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ComPAC™  
DC-DC Switchers  
50 – 600 Watts; 1 – 3 Outputs  
Features & Benefits  
Configuration Chart  
Number of  
Modules  
RoHS Compliant (VE versions)  
Inputs 24, 48 and 300VDC  
Any output: 1 – 95VDC  
Configuration[a]  
Output Power  
Dimensions  
Single Output  
8.6 x 2.5 x 0.99in  
[218,4 x 63,5 x 25,2mm]  
VI‑LC  
50 – 200W  
100 – 400W  
300 – 600W  
1
2
3
Meets EN55022 Class A  
8.6 x 4.9 x 0.99in  
[218,4 x 124,5 x 25,2mm]  
VI‑MC  
conducted emissions (See Notes)  
8.6 x 7.3 x 0.99in  
[218,4 x 185,4 x 25,2mm]  
cULus, cTÜVus (60950-1)  
CE marked (LVD)  
VI‑NC  
Dual Output  
VI‑PC  
8.6 x 4.9 x 0.99in  
[218,4 x 124,5 x 25,2mm]  
80 – 90% efficiency  
Up to 10W/in3  
100 – 400W  
150 – 600W  
2
3
8.6 x 7.3 x 0.99in  
[218,4 x 185,4 x 25,2mm]  
VI‑QC  
Master disable  
Triple Output  
Overvoltage shutdown  
8.6 x 7.3 x 0.99in  
[218,4 x 185,4 x 25,2mm]  
VI‑RC  
150 – 600W  
3
[a] Substitute VE– for VI– for RoHS‑compliant versions  
Product Description  
Input Voltage  
Output Voltage  
ComPAC delivers up to 600W from  
one, two, or three outputs in a package  
just 0.99in [25,2mm] in height with the  
field‑proven performance, high efficiency  
and high reliability inherent in Vicor  
component‑level power converters.  
ComPAC meets conducted emissions of  
EN55022 Class A. ComPAC is offered with  
input voltage ranges optimized for industrial  
and telecommunication applications and  
provides extended input overvoltage  
capability, undervoltage lockout and  
master disable.  
Z = 2V  
Y = 3.3V  
0 = 5V  
2 = 15V  
N = 18.5V  
3 = 24V  
L = 28V  
J = 36V  
K = 40V  
4 = 48V  
H = 52V  
F = 72V  
D = 85V  
B = 95V  
Input  
Nominal Range Full  
Power  
Low Line  
75% Max.  
Power  
Maximum  
Power[b]  
Transient  
(1s)  
1 = 24V  
W = 24V  
3 = 48V  
N = 48V  
21 – 32V  
18 – 36V  
42 – 60V  
36 – 76V  
(1)  
(1)  
(2)  
(2)  
(2)  
18  
N/A  
36  
N/A  
72  
X = 5.2V  
W = 5.5V  
V = 5.8V  
T = 6.5V  
R = 7.5V  
M = 10V  
1 = 12V  
P = 13.8V  
41  
N/A  
N/A  
425  
6 = 300V 200 – 400V  
188  
[b] Max Output  
per Module  
5V  
Outputs  
>5V  
Outputs  
<5V  
Outputs  
(1)  
(2)  
150W  
200W  
150W  
200W  
30A  
40A  
Product Grade Case Temps. ºC  
Output Power / Current  
Packaging Options  
V
OUT 5V  
VOUT < 5V  
Y = 10A  
X = 15A  
W = 20A  
V = 30A  
U = 40A  
Grade  
E =  
Operating  
–10 to +85  
–25 to +85  
–40 to +85  
–55 to +85  
Storage  
Conduction Cooled Models Available.  
Add “‑CC” to the end of the part number.  
(Consult factory for details.)  
Extended heat sink available.  
Add “–H1” to end of part number.  
Y = 50W  
X = 75W  
–20 to +100  
–40 to +100  
–55 to +100  
–65 to +100  
C =  
W = 100W  
V = 150W  
U = 200W  
I =  
M =  
Output Power / Current  
Output Power / Current  
V
OUT 5V  
VOUT < 5V  
W = 20A  
V = 30A  
U = 40A  
S = 60A  
Q = 80A  
V
OUT 5V  
VOUT < 5V  
S = 60A  
W = 100W  
V = 150W  
U = 200W  
S = 300W  
Q = 400W  
S = 300W  
P = 450W  
M = 600W  
P = 90A  
M = 120A  
ComPAC™ DC-DC  
Page 1 of 8  
Rev 1.3  
10/2014  
ComPAC™ DC-DC Switchers  
Configurable Specifications  
Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified, VNOM is factory set output voltage and INOM is maximum rated output current.  
Input Specifications  
E-Grade  
Typ  
C-, I-, M-Grade  
Typ  
Parameter  
Min  
Max  
Min  
Max  
Unit  
Test Conditions  
24V  
21  
24  
32  
21  
24  
32  
VDC  
24V Wide  
18  
42  
24  
48  
36  
60  
76  
400  
2
18  
42  
24  
48  
36  
60  
76  
400  
2
VDC  
VDC  
See Fusing Information  
48V  
on Page 3  
48V Wide  
36  
48  
36  
48  
VDC  
300V  
200  
1.35  
300  
200  
1.35  
300  
VDC  
No Load Power Dissipation[c]  
Watts  
Sink or source to disable  
optocoupler (See Section 18  
ComPAC Technical Description  
in VI‑200™/VI‑J00™  
Master Disable Input Current[c]  
(Absolute Max., 20mA)  
4
4
mA  
mA  
Applications Manual)  
Quiescent Input Current  
Logic Disable[c]  
Current drawn from source  
when disabled  
7
10  
7
10  
[c] For MC, PC series, multiply value by 2; for NC, QC, RC series, multiply value by 3.  
Output Specifications  
Applies to each output individually.  
E-Grade  
C-, I-, M-Grade  
Typ  
Parameter  
Min  
Typ  
Max  
Min  
Max  
Units  
Test Conditions  
Set Point Accuracy  
Load / Line Regulation  
Load / Line Regulation  
Output Temperature Drift  
Long‑Term Drift  
Output Ripple  
1%  
2%  
0.5%  
1%  
0.5%  
0.05%  
0.2%  
0.01  
1%  
VNOM  
VNOM  
0.2%  
0.5%  
0.02  
LL to HL, 10% to full load  
LL to HL, no load to full load  
Over‑rated temperature range  
VNOM  
0.02  
0.02  
%/°C  
0.02  
%/1khrs.  
2V, 3.3V  
150  
250  
60  
100  
100  
150  
mVP‑P  
mVP‑P  
20MHz bandwidth  
20MHz bandwidth  
20MHz bandwidth  
5V  
10 – 48V  
3%  
0.75%  
1.5%  
110%  
VNOM  
P‑P  
Output Voltage Trimming[d]  
50%  
0.5  
110%  
50%  
0.5  
VNOM  
Volts  
Total Remote‑Sense  
Compensation[d]  
0.25V maximum allowable  
drop in –OUT lead  
OVP Set Point  
125%  
115%  
105%  
20%  
125%  
135%  
125%  
130%  
VNOM  
INOM  
INOM  
Recycle power to restart  
Automatic restart  
Current Limit  
105%  
20%  
135%  
140%  
Short‑Circuit Current[e]  
[d] 10, 12 and 15V outputs, trim range 10%. Consult factory for wider trim range.  
[e] Output voltages of 5V or less incorporate foldback current limiting, outputs greater than 5V incorporate straight line current limiting.  
ComPAC™ DC-DC  
Page 2 of 8  
Rev 1.3  
10/2014  
ComPAC™ DC-DC Switchers  
Configurable Specifications (Cont.)  
Thermal Characteristics  
E-Grade  
C-, I-, M-Grade  
Parameter  
Min  
Typ  
Max  
Min  
Typ  
Max  
Units  
Test Conditions  
Efficiency  
78 – 88%  
95  
80 – 90%  
95  
for 5V outputs and higher  
90  
105  
85  
90  
105  
85  
°C  
°C  
Cool and recycle power  
to restart  
Shut‑Down Temp. — Case [f]  
Operating Temp. — Case  
See Thermal Curves  
[f] Shut‑down temperature threshold is above maximum operating temperature. For over temperature protection, external means of disable should be  
employed below maximum operating temperature.  
Isolation Characteristics  
E-Grade  
Typ  
C-, I-, M-Grade  
Typ  
Parameter  
Min  
Max  
Min  
Max  
Unit  
Test Conditions  
Isolation  
Input to Output  
4,242  
707  
4,242  
707  
VDC  
VDC  
VDC  
Output to Case  
Input to Case  
2,121  
2,121  
Mechanical Specifications  
E-Grade  
Typ  
C-, I-, M-Grade  
Typ  
Parameter  
Min  
Max  
Min  
Max  
Units  
Test Conditions  
19.2  
19.2  
Ounces  
[Grams]  
Weight[g]  
[544]  
[544]  
[g] For MC, PC series, multiply value by 2; for NC, QC, RC series, multiply value by 3.  
Fusing Information  
Input Voltage  
24V  
10A  
20A  
35A  
48V  
7A  
300V  
2A  
LC Series (200W)  
MC, PC Series (400W)  
NC, QC, RC Series (600W)  
15A  
25A  
4A  
6A  
ComPAC™ DC-DC  
Page 3 of 8  
Rev 1.3  
10/2014  
ComPAC™ DC-DC Switchers  
Configurable Specifications (Cont.)  
Agency Approvals  
Safety Standards  
Markings  
Notes  
ANSI / ISA 12.12.01 ‑ 2012, C22.2 No. 213‑M1987  
UL / CSA / EN / IEC 60950‑1  
cURus  
cURus, cTÜVus,CE Marked  
Low Voltage Directive and RoHS Recast Directive  
as applicable.  
EMI / EMC Characteristics  
Performed on selected samples representative of the ComPAC product family.  
Parameter  
Notes  
Conducted Emissions  
EN 55022, Class A  
3‑Module configurations may require additional filter components under certain line and load conditions to comply  
with EN55022 class A.  
ESD  
IEC 61000‑4‑2 Level 4  
Top, Bottom and Sides  
ComPAC™ DC-DC  
Page 4 of 8  
Rev 1.3  
10/2014  
ComPAC™ DC-DC Switchers  
Thermal Curves  
FREE AIR  
50LFM  
100LFM  
250LFM  
500LFM  
750LFM  
1000LFM  
2V to 7.5V Output, Standard heat sink  
400  
350  
300  
250  
200  
150  
100  
50  
200  
175  
150  
125  
100  
75  
600  
525  
450  
375  
300  
225  
150  
75  
50  
25  
0
0
0
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (ºC)  
Ambient Temperature (ºC)  
Ambient Temperature (ºC)  
LC Series  
MC, PC Series  
NC, QC, RC Series  
10V to 95V Output, Standard heat sink  
200  
175  
150  
125  
100  
75  
400  
350  
300  
250  
200  
150  
100  
50  
600  
525  
450  
375  
300  
225  
150  
75  
50  
25  
0
0
0
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
0
5
10  
15  
20  
25  
30  
Ambient Temperature (ºC)  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (ºC)  
Ambient Temperature (ºC)  
LC Series  
MC, PC Series  
NC, QC, RC Series  
2V to 7.5V Output , H1 heat sink  
400  
350  
300  
250  
200  
150  
100  
50  
200  
175  
150  
125  
100  
75  
600  
525  
450  
375  
300  
225  
150  
75  
50  
25  
0
0
0
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
0
5
10  
15  
20  
25  
Ambi  
30  
e
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambent empeature °
Ambient Temperature (ºC)  
n
t
i
T
e
m
m  
p
e
r
a
t
r
u
r
°  
e
(ºC)  
Ambient Temperature (ºC)  
Ambient Temperature (°C)  
LC Series  
MC, PC Series  
NC, QC, RC Series  
10V to 95V Output, H1 heat sink  
400  
350  
300  
250  
200  
150  
100  
50  
600  
200  
175  
150  
125  
100  
75  
525  
450  
375  
300  
225  
150  
75  
50  
25  
0
0
0
0
5
10  
15  
20  
25  
Ambi  
30  
e  
35  
40  
45  
50  
55  
(ºC)  
60  
65  
70  
75  
80  
85  
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
n
t
T
e
m
p
e
r
a
t
u
r
e
Am  
b
ie
n
t  
T
e
m
p
e
r
a
t
u
r
e (ºC)  
Ambient Temperature (ºC)  
LC Series  
MC, PC Series  
NC, QC, RC Series  
ComPAC™ DC-DC  
Page 5 of 8  
Rev 1.3  
10/2014  
ComPAC™ DC-DC Switchers  
Mechanical Drawings  
All Models  
INPUTS  
Measure case temperature on this surface.  
1
Ground  
–Input  
2
0.99  
0.5  
3
4
5
+Input  
(25,15)  
(12,57)  
Standard Heat sink  
Disable–  
Disable+  
8.63.025  
(219,2  
,64)  
0.41  
(10,4)  
OUTPUTS  
+Output  
+Sense  
Trim  
A
1.37  
(34,80)  
1.12  
B
C
D
E
0.5  
Optional heat sink (H1)  
(28,4)  
(12,57)  
–Sense  
–Output  
9.25 .120  
(235,03,05)  
LC Series  
0.18  
(4,6)  
6.00  
2.76  
(152,4)  
(70,1)  
0
0.91  
(23,1)  
5
3
.41 (10,41)  
.75 (19,05)  
L
0.19  
(4,8)  
4
2
B
2.156  
1.14 (28,96)  
1.53 (38,86)  
2.54  
(64,5)  
A
(54,76)  
0.20  
D
(5,1)  
2.11 (53,59)  
1
C
.25 ꢀYꢁ  
ø.150 .005 ꢀTHR 4 ꢁPLACE  
(ø3,81 0,13)  
0.20  
(5,1)  
#8-32 EꢀRD  
2 ꢁPLACE  
MC, PC Series  
6.00  
2.76  
(70,1)  
0.18  
(4,6)  
(152,4)  
0
.41 (10,41)  
.75 (19,05)  
1.14 (28,96)  
1.53 (38,86)  
L
B
L
B
0.19  
(4,8)  
2.281  
A
3.04  
(77,2)  
(57,94)  
3.58  
D
C
L
B
A
D
(90,9)  
2.11 (53,59)  
4.562  
4.96  
(126,0)  
5
3
1
(115,87)  
2.83 (71,88)  
3.17 (80,52)  
3.56 (90,42)  
3.95 (100,33)  
4
A
2
D
C
0.20  
(5,1)  
4.53 (115,06)  
C
.25 ꢀYꢁ  
#8-32 EꢀRD  
4 ꢁPLACE  
ø.150 .005 ꢀTHR 5 ꢁPLACE  
(ø3,81 0,13)  
#10-32 EꢀRD  
2 ꢁPLACE  
NC, QC, RC Series  
0.18  
(4,6)  
2.76  
6.00  
#8-32 EꢀRD  
(70,1)  
(152,4)  
2 ꢁPLACE  
0
.41 (10,41)  
L
B
L
L
B
.75 (19,05)  
1.14 (28,96)  
1.53 (38,86)  
0.19  
(4,8)  
2.288  
A
(58,12)  
D
C
L
B
A
D
D
C
4.42  
2.11 (53,59)  
4.96  
(112,3)  
(126,0)  
2.83 (53,59)  
3.17 (80,52)  
3.56 (90,42)  
3.95 (100.33)  
L
7.380  
(187,45)  
7.00  
2.420  
(61,47)  
5
3
1
(177,8)  
4
2
4.53 (115,06)  
C
5.25 (133,35)  
5.59 (141,99)  
5.98 (151,89)  
6.37 (161,80)  
L
B
B
A
D
0.20  
(5,1)  
B
A
A
D
D
C
6.95 (176,53)  
C
C
.25 ꢀYꢁ  
#8-32 EꢀRD  
6 ꢁPLACE  
ø.150 .005 ꢀTHR 6 ꢁPLACE  
(ø3,81 0,13)  
#10-32 EꢀRD  
2 ꢁPLACE  
#10-32 EꢀRD  
2 ꢁPLACE  
ComPAC™ DC-DC  
Page 6 of 8  
Rev 1.3  
10/2014  
ComPAC™ DC-DC Switchers  
Long-Term Safe Operating Area Curves  
1% duty cycle max., ZS = 0.5Ω, for short duration transient capability refer to specifications.  
24V Inputs  
48V Input  
Standard  
100V  
Wide Range  
R.E.  
100V  
R.E.  
160V  
I.S.W.  
S.D.  
36V  
18V  
Full Load  
I.S.W.  
100V  
60V  
Full Load  
S.D.  
32V  
21V  
Normal Operating Area  
Normal Operating Area  
42V  
0.1  
1
10ms 100 1000  
0.1  
1
10ms 100 1000  
48V Wide Range Input  
300V Input  
276V  
R.E.  
R.E.  
800V  
I.S.W.  
I.S.W.  
125V  
76V  
500V  
400V  
100V  
Full Load  
S.D.  
Full Load  
S.D.  
Normal Operating Area  
10ms 100  
Normal Operating Area  
10ms 100 1000  
S.D.  
200V  
36V  
0.1  
1
1000  
500ms  
0.1  
1
500ms  
I.S.W.: Input surge withstand, no degradation of performance. R.E.: Ratings Exceeded. S.D.: Shutdown  
ComPAC™ DC-DC  
Page 7 of 8  
Rev 1.3  
10/2014  
ComPAC™ DC-DC Switchers  
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and  
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom  
power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor  
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves  
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by  
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.  
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where  
mandated by government requirements, testing of all parameters of each product is not necessarily performed.  
Specifications are subject to change without notice.  
Visit http://www.vicorpower.com/dc‑dc‑power‑systems/compac for the latest product information.  
Vicor’s Standard Terms and Conditions and Product Warranty  
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage  
(http://www.vicorpower.com/termsconditionswarranty) or upon request.  
Life Support Policy  
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE  
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used  
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and  
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to  
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform  
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms  
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies  
Vicor against all liability and damages.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the  
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property  
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.  
Contact Us: http://www.vicorpower.com/contact‑us  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800‑735‑6200  
Fax: 978‑475‑6715  
www.vicorpower.com  
email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
©2018 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.  
All other trademarks, product names, logos and brands are property of their respective owners.  
ComPAC™ DC-DC  
Page 8 of 8  
Rev 1.3  
10/2014  

相关型号:

VI-MC60-MW

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10
VICOR

VI-MC61-CU

DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, PACKAGE-10
VICOR

VI-MC61-CU-H1

DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, PACKAGE-10
VICOR

VI-MC61-CV

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10
VICOR

VI-MC61-CV-H1

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, PACKAGE-10
VICOR

VI-MC61-CW

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10
VICOR

VI-MC61-CW-CC

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10
VICOR

VI-MC61-EU

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10
VICOR

VI-MC61-EUH1

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10
VICOR

VI-MC61-EV

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10
VICOR

VI-MC61-EVH1

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10
VICOR

VI-MC61-EW-CC

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-10
VICOR