VI-MC6D-EU-H1 [VICOR]
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, PACKAGE-10;型号: | VI-MC6D-EU-H1 |
厂家: | VICOR CORPORATION |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, PACKAGE-10 |
文件: | 总8页 (文件大小:704K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ComPAC™
DC-DC Switchers
50 – 600 Watts; 1 – 3 Outputs
Features & Benefits
Configuration Chart
Number of
Modules
• RoHS Compliant (VE versions)
• Inputs 24, 48 and 300VDC
• Any output: 1 – 95VDC
Configuration[a]
Output Power
Dimensions
Single Output
8.6 x 2.5 x 0.99in
[218,4 x 63,5 x 25,2mm]
–
–
–
VI‑LC
50 – 200W
100 – 400W
300 – 600W
1
2
3
• Meets EN55022 Class A
8.6 x 4.9 x 0.99in
[218,4 x 124,5 x 25,2mm]
VI‑MC
conducted emissions (See Notes)
8.6 x 7.3 x 0.99in
[218,4 x 185,4 x 25,2mm]
• cULus, cTÜVus (60950-1)
• CE marked (LVD)
VI‑NC
Dual Output
VI‑PC
8.6 x 4.9 x 0.99in
[218,4 x 124,5 x 25,2mm]
• 80 – 90% efficiency
• Up to 10W/in3
–
–
100 – 400W
150 – 600W
2
3
8.6 x 7.3 x 0.99in
[218,4 x 185,4 x 25,2mm]
VI‑QC
• Master disable
Triple Output
• Overvoltage shutdown
8.6 x 7.3 x 0.99in
[218,4 x 185,4 x 25,2mm]
–
VI‑RC
150 – 600W
3
[a] Substitute VE– for VI– for RoHS‑compliant versions
Product Description
Input Voltage
Output Voltage
ComPAC delivers up to 600W from
one, two, or three outputs in a package
just 0.99in [25,2mm] in height with the
field‑proven performance, high efficiency
and high reliability inherent in Vicor
component‑level power converters.
ComPAC meets conducted emissions of
EN55022 Class A. ComPAC is offered with
input voltage ranges optimized for industrial
and telecommunication applications and
provides extended input overvoltage
capability, undervoltage lockout and
master disable.
Z = 2V
Y = 3.3V
0 = 5V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
H = 52V
F = 72V
D = 85V
B = 95V
Input
Nominal Range Full
Power
Low Line
75% Max.
Power
Maximum
Power[b]
Transient
(1s)
1 = 24V
W = 24V
3 = 48V
N = 48V
21 – 32V
18 – 36V
42 – 60V
36 – 76V
(1)
(1)
(2)
(2)
(2)
18
N/A
36
N/A
72
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
41
N/A
N/A
425
6 = 300V 200 – 400V
188
[b] Max Output
per Module
5V
Outputs
>5V
Outputs
<5V
Outputs
(1)
(2)
150W
200W
150W
200W
30A
40A
Product Grade Case Temps. ºC
Output Power / Current
Packaging Options
V
OUT ≥ 5V
VOUT < 5V
Y = 10A
X = 15A
W = 20A
V = 30A
U = 40A
Grade
E =
Operating
–10 to +85
–25 to +85
–40 to +85
–55 to +85
Storage
Conduction Cooled Models Available.
Add “‑CC” to the end of the part number.
(Consult factory for details.)
Extended heat sink available.
Add “–H1” to end of part number.
Y = 50W
X = 75W
–20 to +100
–40 to +100
–55 to +100
–65 to +100
C =
W = 100W
V = 150W
U = 200W
I =
M =
Output Power / Current
Output Power / Current
V
OUT ≥ 5V
VOUT < 5V
W = 20A
V = 30A
U = 40A
S = 60A
Q = 80A
V
OUT ≥ 5V
VOUT < 5V
S = 60A
W = 100W
V = 150W
U = 200W
S = 300W
Q = 400W
S = 300W
P = 450W
M = 600W
P = 90A
M = 120A
ComPAC™ DC-DC
Page 1 of 8
Rev 1.3
10/2014
ComPAC™ DC-DC Switchers
Configurable Specifications
Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified, VNOM is factory set output voltage and INOM is maximum rated output current.
Input Specifications
E-Grade
Typ
C-, I-, M-Grade
Typ
Parameter
Min
Max
Min
Max
Unit
Test Conditions
24V
21
24
32
21
24
32
VDC
24V Wide
18
42
24
48
36
60
76
400
2
18
42
24
48
36
60
76
400
2
VDC
VDC
See Fusing Information
48V
on Page 3
48V Wide
36
48
36
48
VDC
300V
200
1.35
300
200
1.35
300
VDC
No Load Power Dissipation[c]
Watts
Sink or source to disable
optocoupler (See Section 18
ComPAC Technical Description
in VI‑200™/VI‑J00™
Master Disable Input Current[c]
(Absolute Max., 20mA)
4
4
mA
mA
Applications Manual)
Quiescent Input Current
Logic Disable[c]
Current drawn from source
when disabled
7
10
7
10
[c] For MC, PC series, multiply value by 2; for NC, QC, RC series, multiply value by 3.
Output Specifications
Applies to each output individually.
E-Grade
C-, I-, M-Grade
Typ
Parameter
Min
Typ
Max
Min
Max
Units
Test Conditions
Set Point Accuracy
Load / Line Regulation
Load / Line Regulation
Output Temperature Drift
Long‑Term Drift
Output Ripple
1%
2%
0.5%
1%
0.5%
0.05%
0.2%
0.01
1%
VNOM
VNOM
0.2%
0.5%
0.02
LL to HL, 10% to full load
LL to HL, no load to full load
Over‑rated temperature range
VNOM
0.02
0.02
%/°C
0.02
%/1khrs.
2V, 3.3V
150
250
60
100
100
150
mVP‑P
mVP‑P
20MHz bandwidth
20MHz bandwidth
20MHz bandwidth
5V
10 – 48V
3%
0.75%
1.5%
110%
VNOM
P‑P
Output Voltage Trimming[d]
50%
0.5
110%
50%
0.5
VNOM
Volts
Total Remote‑Sense
Compensation[d]
0.25V maximum allowable
drop in –OUT lead
OVP Set Point
125%
115%
105%
20%
125%
135%
125%
130%
VNOM
INOM
INOM
Recycle power to restart
Automatic restart
Current Limit
105%
20%
135%
140%
Short‑Circuit Current[e]
[d] 10, 12 and 15V outputs, trim range 10%. Consult factory for wider trim range.
[e] Output voltages of 5V or less incorporate foldback current limiting, outputs greater than 5V incorporate straight line current limiting.
ComPAC™ DC-DC
Page 2 of 8
Rev 1.3
10/2014
ComPAC™ DC-DC Switchers
Configurable Specifications (Cont.)
Thermal Characteristics
E-Grade
C-, I-, M-Grade
Parameter
Min
Typ
Max
Min
Typ
Max
Units
Test Conditions
Efficiency
78 – 88%
95
80 – 90%
95
for 5V outputs and higher
90
105
85
90
105
85
°C
°C
Cool and recycle power
to restart
Shut‑Down Temp. — Case [f]
Operating Temp. — Case
See Thermal Curves
[f] Shut‑down temperature threshold is above maximum operating temperature. For over temperature protection, external means of disable should be
employed below maximum operating temperature.
Isolation Characteristics
E-Grade
Typ
C-, I-, M-Grade
Typ
Parameter
Min
Max
Min
Max
Unit
Test Conditions
Isolation
Input to Output
4,242
707
4,242
707
VDC
VDC
VDC
Output to Case
Input to Case
2,121
2,121
Mechanical Specifications
E-Grade
Typ
C-, I-, M-Grade
Typ
Parameter
Min
Max
Min
Max
Units
Test Conditions
19.2
19.2
Ounces
[Grams]
Weight[g]
[544]
[544]
[g] For MC, PC series, multiply value by 2; for NC, QC, RC series, multiply value by 3.
Fusing Information
Input Voltage
24V
10A
20A
35A
48V
7A
300V
2A
LC Series (200W)
MC, PC Series (400W)
NC, QC, RC Series (600W)
15A
25A
4A
6A
ComPAC™ DC-DC
Page 3 of 8
Rev 1.3
10/2014
ComPAC™ DC-DC Switchers
Configurable Specifications (Cont.)
Agency Approvals
Safety Standards
Markings
Notes
ANSI / ISA 12.12.01 ‑ 2012, C22.2 No. 213‑M1987
UL / CSA / EN / IEC 60950‑1
cURus
cURus, cTÜVus,CE Marked
Low Voltage Directive and RoHS Recast Directive
as applicable.
EMI / EMC Characteristics
Performed on selected samples representative of the ComPAC product family.
Parameter
Notes
Conducted Emissions
EN 55022, Class A
3‑Module configurations may require additional filter components under certain line and load conditions to comply
with EN55022 class A.
ESD
IEC 61000‑4‑2 Level 4
Top, Bottom and Sides
ComPAC™ DC-DC
Page 4 of 8
Rev 1.3
10/2014
ComPAC™ DC-DC Switchers
Thermal Curves
FREE AIR
50LFM
100LFM
250LFM
500LFM
750LFM
1000LFM
2V to 7.5V Output, Standard heat sink
400
350
300
250
200
150
100
50
200
175
150
125
100
75
600
525
450
375
300
225
150
75
50
25
0
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (ºC)
Ambient Temperature (ºC)
Ambient Temperature (ºC)
LC Series
MC, PC Series
NC, QC, RC Series
10V to 95V Output, Standard heat sink
200
175
150
125
100
75
400
350
300
250
200
150
100
50
600
525
450
375
300
225
150
75
50
25
0
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
Ambient Temperature (ºC)
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (ºC)
Ambient Temperature (ºC)
LC Series
MC, PC Series
NC, QC, RC Series
2V to 7.5V Output , H1 heat sink
400
350
300
250
200
150
100
50
200
175
150
125
100
75
600
525
450
375
300
225
150
75
50
25
0
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
Ambi
30
e
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambent empeature °
Ambient Temperature (ºC)
n
t
i
T
e
m
m
p
e
r
a
t
r
u
r
°
e
(ºC)
Ambient Temperature (ºC)
Ambient Temperature (°C)
LC Series
MC, PC Series
NC, QC, RC Series
10V to 95V Output, H1 heat sink
400
350
300
250
200
150
100
50
600
200
175
150
125
100
75
525
450
375
300
225
150
75
50
25
0
0
0
0
5
10
15
20
25
Ambi
30
e
35
40
45
50
55
(ºC)
60
65
70
75
80
85
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
n
t
T
e
m
p
e
r
a
t
u
r
e
Am
b
ie
n
t
T
e
m
p
e
r
a
t
u
r
e (ºC)
Ambient Temperature (ºC)
LC Series
MC, PC Series
NC, QC, RC Series
ComPAC™ DC-DC
Page 5 of 8
Rev 1.3
10/2014
ComPAC™ DC-DC Switchers
Mechanical Drawings
All Models
INPUTS
Measure case temperature on this surface.
1
Ground
–Input
2
0.99
0.5
3
4
5
+Input
(25,15)
(12,57)
Standard Heat sink
Disable–
Disable+
8.63.025
(219,2
,64)
0.41
(10,4)
OUTPUTS
+Output
+Sense
Trim
A
1.37
(34,80)
1.12
B
C
D
E
0.5
Optional heat sink (H1)
(28,4)
(12,57)
–Sense
–Output
9.25 .120
(235,03,05)
LC Series
0.18
(4,6)
6.00
2.76
(152,4)
(70,1)
0
0.91
(23,1)
5
3
.41 (10,41)
.75 (19,05)
L
0.19
(4,8)
4
2
B
2.156
1.14 (28,96)
1.53 (38,86)
2.54
(64,5)
A
(54,76)
0.20
D
(5,1)
2.11 (53,59)
1
C
.25 ꢀYꢁ
ø.150 .005 ꢀTHR 4 ꢁPLACE
(ø3,81 0,13)
0.20
(5,1)
#8-32 EꢀRD
2 ꢁPLACE
MC, PC Series
6.00
2.76
(70,1)
0.18
(4,6)
(152,4)
0
.41 (10,41)
.75 (19,05)
1.14 (28,96)
1.53 (38,86)
L
B
L
B
0.19
(4,8)
2.281
A
3.04
(77,2)
(57,94)
3.58
D
C
L
B
A
D
(90,9)
2.11 (53,59)
4.562
4.96
(126,0)
5
3
1
(115,87)
2.83 (71,88)
3.17 (80,52)
3.56 (90,42)
3.95 (100,33)
4
A
2
D
C
0.20
(5,1)
4.53 (115,06)
C
.25 ꢀYꢁ
#8-32 EꢀRD
4 ꢁPLACE
ø.150 .005 ꢀTHR 5 ꢁPLACE
(ø3,81 0,13)
#10-32 EꢀRD
2 ꢁPLACE
NC, QC, RC Series
0.18
(4,6)
2.76
6.00
#8-32 EꢀRD
(70,1)
(152,4)
2 ꢁPLACE
0
.41 (10,41)
L
B
L
L
B
.75 (19,05)
1.14 (28,96)
1.53 (38,86)
0.19
(4,8)
2.288
A
(58,12)
D
C
L
B
A
D
D
C
4.42
2.11 (53,59)
4.96
(112,3)
(126,0)
2.83 (53,59)
3.17 (80,52)
3.56 (90,42)
3.95 (100.33)
L
7.380
(187,45)
7.00
2.420
(61,47)
5
3
1
(177,8)
4
2
4.53 (115,06)
C
5.25 (133,35)
5.59 (141,99)
5.98 (151,89)
6.37 (161,80)
L
B
B
A
D
0.20
(5,1)
B
A
A
D
D
C
6.95 (176,53)
C
C
.25 ꢀYꢁ
#8-32 EꢀRD
6 ꢁPLACE
ø.150 .005 ꢀTHR 6 ꢁPLACE
(ø3,81 0,13)
#10-32 EꢀRD
2 ꢁPLACE
#10-32 EꢀRD
2 ꢁPLACE
ComPAC™ DC-DC
Page 6 of 8
Rev 1.3
10/2014
ComPAC™ DC-DC Switchers
Long-Term Safe Operating Area Curves
1% duty cycle max., ZS = 0.5Ω, for short duration transient capability refer to specifications.
24V Inputs
48V Input
Standard
100V
Wide Range
R.E.
100V
R.E.
160V
I.S.W.
S.D.
36V
18V
Full Load
I.S.W.
100V
60V
Full Load
S.D.
32V
21V
Normal Operating Area
Normal Operating Area
42V
0.1
1
10ms 100 1000
0.1
1
10ms 100 1000
48V Wide Range Input
300V Input
276V
R.E.
R.E.
800V
I.S.W.
I.S.W.
125V
76V
500V
400V
100V
Full Load
S.D.
Full Load
S.D.
Normal Operating Area
10ms 100
Normal Operating Area
10ms 100 1000
S.D.
200V
36V
0.1
1
1000
500ms
0.1
1
500ms
I.S.W.: Input surge withstand, no degradation of performance. R.E.: Ratings Exceeded. S.D.: Shutdown
ComPAC™ DC-DC
Page 7 of 8
Rev 1.3
10/2014
ComPAC™ DC-DC Switchers
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/dc‑dc‑power‑systems/compac for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Contact Us: http://www.vicorpower.com/contact‑us
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800‑735‑6200
Fax: 978‑475‑6715
www.vicorpower.com
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
©2018 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.
All other trademarks, product names, logos and brands are property of their respective owners.
ComPAC™ DC-DC
Page 8 of 8
Rev 1.3
10/2014
相关型号:
©2020 ICPDF网 联系我们和版权申明