VI-RCNY31-CWVVH1 [VICOR]
DC-DC Regulated Power Supply Module, 3 Output, Hybrid, PACKAGE-20;型号: | VI-RCNY31-CWVVH1 |
厂家: | VICOR CORPORATION |
描述: | DC-DC Regulated Power Supply Module, 3 Output, Hybrid, PACKAGE-20 输出元件 |
文件: | 总4页 (文件大小:149K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC-DC Switchers
50 to 600W
1-3 Outputs
™
C o m P AC
Product Highlights
ComPAC meets Bellcore, British
Telecom and IEC specifications for
transient protection; Bellcore, British
Telecom and FCC/VDE specifications
for EMI/RFI; and benefits from the
proven field performance, high
efficiency and inherent high reliability
of our VI-200 component-level power
converters. With input voltage ranges
optimized for industrial and
telecommunication applications,
ComPAC provides extended input
overvoltage capability, input reverse
polarity protection, undervoltage
lockout, and master disable. In a
package just .99" (25,2mm) in height,
ComPAC delivers up to 600W
from one, two or three outputs of
1 to 95Vdc.
Features
➤ Inputs 24, 48, and 300Vdc
➤ 80-90% Efficiency
➤ Up to 10W/Cubic Inch
➤ Reverse Polarity Protected
➤ Master Disable
➤ Any Output: 1 to 95Vdc
➤ High Surge Withstand:
Bellcore, British Telecom BTR 2511,
EN-61000-4-5
➤ Overvoltage Shutdown
➤ EMI/RFI Specifications:
Bellcore TR-TSY-000513,
British Telecom BTR 2511,
FCC Class A, EN55022 Class B
➤ UL, CSA, TÜV (IEC 950)
ComPAC Configuration Chart
Total Power
Part No.
Dimensions
Single Outputs: 50-200W VI-LC
8.6"L x 2.5"W x 0.99"H
(218,4 x 63,5 x 25,2mm)
–
–
–
Use the configuration chart at the right to define your
Vicor part number(s).
100-400W VI-MC
300-600W VI-NC
8.6"L x 4.9"W x 0.99"H
(218,4 x 124,5 x 25,2mm)
Conduction Cooled Models Available
Add "-CC" to the end of the part number
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
Dual Outputs: 100-400W VI-PC
150-600W VI-QC
8.6"L x 4.9"W x 0.99"H
(218,4 x 124,5 x 25,2mm)
–
–
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
Triple Outputs: 150-600W VI-RC
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
–
Input Voltage
Output Voltage
Product Grade
Nominal
Range
Z = 2V
Y = 3.3V
0 = 5V
M = 10V
1 = 12V
2 = 15V
3 = 24V
L = 28V
4 = 48V
E = -10°C to +85°C
C = -25°C to +85°C
= -40°C to +85°C
1 = 24V 21 - 32V (1)
W = 24V 18 - 36V (1)
3 = 48V 42 - 60V (2)
N = 48V 36 - 76V (2)
6 = 300V 200 - 400V (2)
I
M = -55°C to +85°C
(1 to 95V, consult factory)
Output Power/Current
Output Power/Current
Output Power/Current
Vout ≥ 5V
Vout < 5V
Vout ≥ 5V
Vout < 5V
Vout ≥ 5V
Vout < 5V
Y = 50W
X = 75W
W = 100W
V = 150W
U = 200W
10A
15A
20A
30A
40A
W = 100W
V = 150W
U = 200W
S = 300W
Q = 400W
20A
30A
40A
60A
80A
S = 300W
P = 450W
M = 600W
60A
90A
120A
Max output for 5V Outputs >5V Outputs <5V Outputs
(1)
(2)
150W
200W
150W
200W
30A
40A
Fo r la t e s t Vic o r P ro d u c t In fo rm a t io n : w w w .vic r.c o m
Vers 1 11/99 1 of 4
ComPAC Specifications
(Typical at 25°C, nominal line and 75% load, unless otherwise specified)
E-GRADE
C-, I-, M-GRADE
TYP
PARAMETER
MIN
TYP
MAX
MIN
MAX
BROWNOUT* TRANSIENT**
UNITS
NOTES
Input Characteristics
24V (21-32V)
24V Wide (18-36V)
48V (42-60V)
48V Wide (36-76V)
300V (200-400V)
Input surge withstand
21
18
42
36
200
24
24
48
48
300
32
36
60
76
400
21
18
42
36
200
24
24
48
48
300
32
36
60
76
400
18
n/a
36
n/a
170
36
n/a
72
n/a
425
Volts
Volts
Volts
Volts
Volts
See Fusing Information below
See Fusing Information below
See Fusing Information below
See Fusing Information below
See Fusing Information below
(Up to 200 mS, Z = .5Ω, no interruption
s
of performance, see: Long Term Safe Operating Area Curves)
24V & 48V Bellcore, British Telecom BTR 2511
300V, EN-61000-4-5
24V & 48V Bellcore TR-TSY-000513, Issue 2, Rev. 1
British Telecom BTR 2511, Issue 2
Transient specification
EMI/RFI
300V FCC Pt. 15 Subpart J, Class “A”
VDE 0871 Class “A”
No load power dissipation4 1.35
Master disable input current3
(Absolute max., 20 mA)
2
4
1.35
2
4
Watts
mA
Sink or source into disable
optocoupler
Current drawn from source
when disabled
Input current logic disable3
7
10
7
10
mA
Reverse polarity protection
No damage to unit with
external fuse
Output Characteristics (applies to each output individually)
Setpoint accuracy
Load/line regulation
Load/line regulation
Output temperature drift
Long term drift
Output ripple - pp:
2V
1%
2%
0.5%
1%
0.5%
0.05%
0.2%
0.01
1%
V
NOM
0.2%
0.5%
0.02
V
LL to HL, 10% to Full Load
LL to HL, No Load to 10%
Over rated temperature
NOM
V
NOM
0.02
0.02
%/°C
%/1K hours
0.02
150mV
5%
3%
60mV
2%
0.75%
100mV
3%
1.5%
110%
p-p
p-p
p-p
20 MHz bandwidth
20 MHz bandwidth
20 MHz bandwidth
5V
10-48V
Output voltage trimming1 50%
Total remote sense
110%
50%
compensation1
OVP set point
0.5
0.5
Volts
0.25V max. neg. leg
Recycle power
Automatic restart
125%
115%
105%
20%
125%
135%
125%
130%
V
NOM
Current limit
105%
20%
135%
140%
INOM
INOM
Short circuit current2
Thermal Characteristics
Efficiency
Shutdown temp. — case 90
Operating temp. — case
78-88%
95
80-90%
95
105
85
90
105
85
°C
°C
Cool and recycle power to restart
See Thermal Curves
Isolation Characteristics
Isolation
Input Voltage
Vdc
Vdc
Input to output
Output to case
Input to case
4242
707
2121
Vdc
Mechanical Specifications
Weight4
19.2 (544)
19.2 (544)
Ounces (Grams)
Fusing Information
24V
48V
7A
15A
25A
300V
2A
4A
1 Up (200W)
2 Up (400W)
3 Up (600W)
10A
20A
35A
6A
Safety Agency Approvals
UL, CSA, TÜV, VDE, IEC 950, CE Mark
Environmental Characteristics/Product Grade Designators
E-grade
C-grade
I-grade
M-grade
Storage Temperature
Operating Temperature
Case
-20°C to +100°C
-10°C to +85°C
-40°C to +100°C
-25°C to +85°C
-55°C to +100°C
-40°C to +85°C
-40°C to +85°C
-65°C to +100°C
-55°C to +85°C
-55°C to +85°C
*Brownout 75% of rated load.
**Transient voltage for one second.
1
10V, 12V and 15V outputs, trim range ± 10%. Consult factory for wider trim range.
2
3
4
Output voltages of 5V or less incorporate foldback current limiting, outputs of 10V and above incorporate straight line current limiting.
For PC series, multiply value by 2; for QC series, multiply value by 2; for RC series, multiply value by 3.
For 2 ups, multiply by 2; for 3 ups, multiply by 3.
Fo r la t e s t Vic o r P ro d u c t In fo rm a t io n : w w w .vic r.c o m
Vers 1 11/99 2 of 4
Thermal Curves, 5V Output (Standard heatsink; for H1 heatsink use FlatPAC curves, page 8)
FREE AIR
750 LFM
50 LFM
100 LFM
250 LFM
500 LFM
1000 LFM
400
350
300
250
200
150
100
50
600
525
450
375
300
225
150
75
200
175
150
125
100
75
50
25
0
0
0
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
1 Up
2 Up
3 UP
Thermal Curves, 10V to 48V Output (Standard heatsink; for H1 heatsink use FlatPAC curves, page 8)
FREE AIR
750 LFM
50 LFM
100 LFM
250 LFM
500 LFM
1000 LFM
200
175
150
125
100
75
400
600
525
450
375
300
225
150
75
350
300
250
200
150
100
50
50
25
0
0
0
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
1 Up
2 Up
3 UP
Long Term Safe Operating Area Curves
Standard
100V
24V Inputs
R.E.
Wide Range
48V Input
100V
R.E.
160V
I.S.W.
Full Load
S.D.
I.S.W.
Full Load
100V
60V
S.D.
32V
21V
36V
18V
Normal Operating Area
10ms 100
Normal Operating Area
42V
0.1
1
1000
0.1
1
10ms
100 1000
48V Wide Range Input
300V Input
276V
R.E.
R.E.
800V
I.S.W.
Full Load
I.S.W.
Full Load
125V
76V
500V
400V
100V
S.D.
S.D.
Normal Operating Area
Normal Operating Area
S.D.
200V
36V
0.1
1
10ms
100
1000
0.1
1
10ms
100 1000
500 ms
500 ms
Fo r la t e s t Vic o r P ro d u c t In fo rm a t io n : w w w .vic r.c o m
Vers 1 11/99 3 of 4
Mechanical Drawings
All Models
INPUTS
1
2
3
4
5
Ground
-Input
+Input
Disable-
Disable+
.99
Standard Units
.5
(12,57)
(25,15)
STANDARD UNITS
8.63±.025
(219,2
.41
±,64)
(10,4)
OUTPUTS
A
B
C
D
E
+Output
+Sense
Trim
-Sense
-Output
Optional Heatsink (H1)
1.37
1.12
(28,4)
.5
(12,57)
(34,80)
OPTIONAL HEATSINK (H1)
9.25 ±.120
(235,0±3,05)
1 Up
.18
4,6
6.00
2.76
70,1
152,4
0
5
.91
.41 (10,41)
.75 (19,05)
1.14 (28,96)
1.53 (38,86)
A
.19
4,8
23,1
4
3
B
C
D
2.54
64,5
2.156
54,76
.20
5,1
2
1
2.11 (53,59)
.25 TYP
E
.20
5,1
#8-32 STUD
2 PLACES
ø.150 ± .005 THRU 4 PLACES
ø3,81 ± 0,13
2 Up
.18
4,6
6.00
2.76
70,1
152,4
0
.41 (10,41)
.75 (19,05)
1.14 (28,96)
1.53 (38,86)
A
A
.19
4,8
B
C
D
2.281
57,94
3.04
3.58
90,9
77,2
2.11 (53,59)
E
A
4.96
4.562
5
3
1
2.83 (71,88)
3.17 (80,52)
3.56 (90,42)
3.95 (100,33)
126,0
115,87
4
2
B
C
D
B
C
D
.20
5,1
4.53 (115,06)
.25 TYP
E
E
#10-32 STUD
2 PLACES
#8-32 STUD
4 PLACES
ø.150 ± .005 THRU 5 PLACES
ø3,81 ± 0,13
3 Up
.18
4,6
6.00
2.76
70,1
#8-32 STUD
2 PLACES
152,4
0
.41 (10,41)
.75 (19,05)
1.14 (28,96)
1.53 (38,86)
A
A
A
.19
B
C
D
B
C
D
2.288
58,12
4,8
4.42
2.11 (53,59)
E
A
E
A
4.96
112,3
2.83 (71,88)
3.17 (80,52)
3.56 (90,42)
3.95 (100,33)
126,0
B
C
D
7.380
7.00
2.420
61,47
5
187,45
177,8
4
4.53 (115,06)
E
A
3
1
5.25 (133,35)
5.59 (141,99)
5.98 (151,89)
6.37 (161,80)
2
.20
5,1
B
C
D
B
C
D
B
C
D
6.95 (176,53)
.25 TYP
E
E
E
#10-32 STUD
2 PLACES
#10-32 STUD
2 PLACES
#8-32 STUD
6 PLACES
ø.150 ± .005 THRU 6 PLACES
ø3,81 ± 0,13
Fo r la t e s t Vic o r P ro d u c t In fo rm a t io n : w w w .vic r.c o m
Vers 1 11/99 4 of 4