NL1013T-02AC [VIMARLOW]
Single-Stage Thermoelectric Module;![NL1013T-02AC](http://pdffile.icpdf.com/pdf2/p00328/img/icpdf/NL1013T-01AC_2019675_icpdf.jpg)
型号: | NL1013T-02AC |
厂家: | ![]() |
描述: | Single-Stage Thermoelectric Module |
文件: | 总3页 (文件大小:514K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Technical Data Sheet for NL1013T
Single-Stage Thermoelectric Module
NOMINAL PERFORMANCE IN VACUUM
Hot Side Temperature (°C)
Δ Tmax (°C):
Qmax (watts):
Imax (amps):
Vmax (vdc):
27
61
4.8
1.0
8.5
7.42
0.77
50
69
5.4
1.0
9.6
--
AC Resistance (ohms):
Device ZT
--
PRODUCT FEATURES
ORDERING OPTIONS
Model Number
Description
TEM, Top and Base Metallized
Exterior
TEM, Base Metallized Exterior
TEM, No Metallized Exterior
TEM, No Metallized Exterior, RTV,
Sealed, Special Wires
•
•
•
•
RoHS EU Compliant
Maximum process temperature is 220°C.
Ceramic Material: Aluminum Oxide
Metallized Exterior Surfaces are Au flash, suitable for
soldering.
NL1013T-01AC
NL1013T-02AC
NL1013T-03AC
•
RTV Sealing options available.
NL1013T-04AC
OPERATION CAUTIONS
INSTALLATION
For maximum reliability, storage and operation below
130°C in a non-condensing environment is recommended.
To minimize thermal stress, use linear/proportional
temperature control or a similar method rather than an
ON/OFF method.
Recommended mounting methods: Bonding with thermal
epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEC Installation Guide.
II-VI Marlow – Dallas, TX USA
214-340-4900
877-627-5691
marlow.sales@ii-vi.com
Marlow Industries Europe
GmbH - Germany
+49 (0) 6150 5439 - 403
info@marlow-europe.eu
II-VI Japan Inc.
81 43 297 2693 (tel)
center@ii-vi.co.jp
www.ii-vi.co.jp
II-VI Singapore Pte., Ltd.
(65) 6481 8215 (tel)
info@ii-vi.com.sg
Marlow Industries China, II-VI
Technologies Beijing
86-10-643 98226
info@iivibj.com
MI Form 005-0808 Rev. A
DOC # 102-0292 REV K - PAGE 1 OF 3
www.marlow.com
ENVIRONMENT: 10^-5 TORR VACUUM
Hot Side Temperature: 27°C
Hot Side Temperature: 50°C
HEAT
LOAD
HEAT
(WATTS)
80
60
40
20
80
60
40
20
LOAD
(WATTS)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
0
8
6
4
2
0
0
8
6
4
2
0
Q=0
T=0
Q=0
T=0
0.0
0.2
0.4
0.6
0.8
1.0
0.0
0.2
0.4
0.6
0.8
1.0
CURRENT (AMPS)
CURRENT (AMPS)
POWER GENERATION PERFORMANCE CURVES
Hot Side Temperature (°C)
Hot Side Temperature (°C)
55
60
65
70
75
80
85
30 35 40 45 50 55
65
75
85
0.04
0.035
0.03
0.025
0.02
0.015
0.01
0.005
0
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
1.2
1
Tc=27°C
Tc=50°C
0.8
0.6
0.4
0.2
0
Power
2.7
Voltage
3.2
Power
Voltage
0.2
0.7
1.2
1.7
2.2
0.3 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9
Heat (W)
Heat (W)
Normalized Off-Peak Performance
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
Hot Side Temperature (°C)
Cold Side Temperature (°C)
Optimum Efficiency, η (%)
Optimum Power (W)
85
27
55
27
35
27
2.52 1.28 0.37
0.087 0.021 0.002
1.021 0.487 0.138
12.00 11.20 10.65
1.79 0.85 0.24
0.20 0.10 0.03
16.86 16.88 16.85
Optimum Voltage (V)
Load Resistance for Opt η (Ω)
Open Circuit Voltage, VOC (V)
Short Circuit Current (A)
Thermal Resistance (°C/W)
Efficiency
Voltage
10
0
1
2
3
4
5
6
7
8
9
Load Resistance Ratio
MI Form 005-0808 Rev. A
DOC # 102-0292 REV K - PAGE 2 OF 3
www.marlow.com
(+), White *
-01AC, -02AC, -03AC:
Leads: 28 AWG, Buss,
Solid Tinned Copper
.518
[13.16]
-04AC ONLY: Leads: 28 AWG, Stranded,
Teflon Insulated
(-), Black *
.518
[13.16]
2.00 +/-0.250
[50.80+/-6.35]
-01AC, -02AC,
-03AC:
.095+/-.005
[2.41 +/-0.13]
1.375 +/-0.075
[34.93+/-1.90]
-04AC ONLY:
.005 [0.13]
.001 [0.03]
A
Cold Side, Tc *
.001 [0.03]
A
* Hot Side, Th
-04AC ONLY:
Perimeter
Sealed
Dimensions are in inches, and millimeters are in [ ].
*NOTE: Cold side, hot side, positive leads, and negative leads are valid only for thermoelectric cooling. For
power generation, see below.
For customer support or general questions please contact a local office or visit our website at www.marlow.com.
Power Generation performance information is given in a nitrogen environment and cold side temperatures of 27°C and 50°C.
Module temperature does not include thermal resistance of heat sinks. For performance information in vacuum, other cold side
temperatures, or specific heat sinks, consult one of our applications engineers.
TYPICAL POWER GENERATION CONFIGURATION
EXAMPLE:
(-)
(+)
Hot Side, Th
Cold Side, Tc
MI Form 005-0808 Rev. A
DOC # 102-0292 REV K - PAGE 3 OF 3