XLT2418-06AC [VIMARLOW]
Single-Stage Thermoelectric Cooler;型号: | XLT2418-06AC |
厂家: | II-VI Marlow, Inc. |
描述: | Single-Stage Thermoelectric Cooler |
文件: | 总2页 (文件大小:164K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TECHNICAL DATA SHEET
XLT2418
Single-Stage Thermoelectric Cooler
RoHS EU Compliant
TYPICAL PERFORMANCE VALUES
Hot Side Temperature (°C)
∆ Tmax (°C-dry N2):
Qmax (watts):
Imax (amps):
Vmax (vdc):
27°C
56.5
127
13.9
14.1
0.83
50°C
64.0
141
13.8
15.7
---
AC Resistance (ohms):
MECHANICAL CHARACTERISTICS
1.760 [44.70]
4.0±.5
.40±.10
[10.16±2.54]
POSITIVE LEAD (WHITE)
LEADWIRES: 20 AWG, 19/32 STRANDING,
TEFLON INSULATED
1.575 [40.01]
1.558
[39.57]
NEGATIVE LEAD (BLACK)
.40±.10
[10.16±2.54]
1.558 [39.57]
COLD SIDE, Tc
.002 [0.05]
.001 [0.03]
A
.092±.001
[2.34±0.025]
.001 [0.03]
A
Dimensions in [ ] are millimeters
Ceramic Material: Alumina (AC)
HOT SIDE, Th
ORDERING OPTIONS
AVAILABLE MODIFICATIONS
Model Number
Description
Rated operating temperature of 125°C.
Designed for temperature cycling applications.
Capable of rapid heating and cooling rates.
Porch configuration for high strength leadwire connection.
RTV sealing option available.
XLT2418-03AC
XLT2418-04AC
XLT2418-05AC
XLT2418-06AC
XLT2418-07AC
XLT2418-08AC
XLT2418-36AC
Leadwires
No Leadwires
Leadwires, Sealed
Leadwires, Diced, 64 sections
No Leadwires, Sealed
Leadwire pad and TEC Sealed
Leadwires, Sealed, Six Coolers,
ACR matched set
Lapped option available for multiple module applications.
Set of modules ACR matched available.
For customer support or general questions please contact a local office or visit our website at www.marlow.com.
DOC # 102-0320 REV K - PAGE 1 OF 2
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN
Hot Side Temperature 50°C
Hot Side Temperature 27°C
60
Heat
Load (W)
0
60
50
40
30
20
10
Heat
Load (W)
50
0
10
10
40
20
20
30
30
30
40
40
50
50
60
20
60
70
70
80
10
80
90
90
100
110
0
0
20
18
16
14
12
10
8
100
18
16
14
12
10
8
Q = 0
Q = 0
T = 0
T = 0
6
6
4
4
2
2
0
0
0
4
8
12
16
20
0
4
8
12
16
20
Current (amps)
Current (amps)
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at
877-627-5691.
Installation
Recommended mounting method: Clamp with uniform pressure to a flat surface with thermal interface material. For additional
information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 125°C in a non-condensing environment is recommended. To minimize
thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
CONTACT US:
For customer support or general questions please contact a local office below or visit our website at www.marlow.com.
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
214-340-4900 (tel)
Marlow Industries Europe GmbH
Brunnenweg 19-21
64331 Weiterstadt
Germany
214-341-5212 (fax)
Tel.: +49 (0) 6150 5439 - 403
Fax: +49 (0) 6150 5439 - 400
info@marlow-europe.eu
877-627-5691 (tech support)
www.marlow.com
II-VI Japan Inc.
II-VI Singapore Pte., Ltd.
Blk. 5012, Techplace II
#04-07 & 05-07/12, Ang Mo Kio Ave. 5
Singapore 569876
Marlow Industries China, II-VI
Technologies Beijing
A subsidiary of II-VI Incorporated
Rm 202, 1# Lize 2nd Middle Road
Wangjing, Chaoyang District
Beijing 100102 China
010-64398226 ext 105 (tel)
010-64399315 (fax)
info@iivibj.com
WBG Marive East 17F
2-6 Nakase, Mihama-ku
Chiba-Shi, Chiba 261-7117
Japan
(65) 6481 8215 (tel)
(65) 6481 8702 (fax)
info@ii-vi.com.sg
81 43 297 2693 (tel)
81 43 297 3003 (fax)
center@ii-vi.co.jp
www.ii-vi.co.jp
www.ii-vi.com.sg
DOC # 102-0320 REV K - PAGE 2 OF 2