26MT../36MT.. Series
Vishay High Power Products
Three Phase Bridge
(Power Modules), 25/35 A
FEATURES
• Universal, 3 way terminals: push-on, wrap
around or solder
• High thermal conductivity package, electrically
insulated case
• Center hole fixing
• Excellent power/volume ratio
• UL E300359 approved
• Gold plated terminals solderable using lead (Pb)-free
solder; solder alloy Sn/Ag/Cu (SAC305); solder
temperature 260 to 275 °C
D-63
• RoHS compliant
• Designed and qualified for industrial and consumer level
DESCRIPTION
A range of extremely compact, encapsulated three phase
bridge rectifiers offering efficient and reliable operation. They
are intended for use in general purpose and instrumentation
applications.
PRODUCT SUMMARY
IO
25/35 A
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL
CHARACTERISTICS
26MT
25
36MT
35
UNITS
A
IO
TC
70
60
°C
50 Hz
60 Hz
50 Hz
60 Hz
360
375
635
580
475
500
1130
1030
IFSM
A
I2t
A2s
VRRM
TJ
100 to 1600
- 55 to 150
V
°C
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
V
RRM, MAXIMUM REPETITIVE
VRSM, MAXIMUM NON-REPETITIVE
IRRM MAXIMUM
AT TJ MAXIMUM
mA
VOLTAGE
CODE
TYPE NUMBER
PEAK REVERSE VOLTAGE
V
PEAK REVERSE VOLTAGE
V
10
20
100
200
150
275
40
400
500
60
600
725
26MT../36MT..
80
800
900
2
100
120
140
160
1000
1200
1400
1600
1100
1300
1500
1700
Document Number: 93565
Revision: 03-Nov-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
1
26MT../36MT.. Series
Three Phase Bridge
(Power Modules), 25/35 A
Vishay High Power Products
FORWARD CONDUCTION
VALUES
26MT
PARAMETER
SYMBOL
TEST CONDITIONS
UNITS
36MT
35
25
70
A
Maximum DC output current at TC
IO
120° rect. conduction angle
60
°C
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
360
375
300
314
635
580
450
410
6360
0.88
1.13
7.9
475
500
400
420
1130
1030
800
730
11 300
0.86
1.03
6.3
No voltage
reapplied
Maximum peak, one-cycle
non-repetitive forward current
IFSM
A
100 % VRRM
reapplied
Initial
TJ = TJ maximum
No voltage
reapplied
Maximum I2t for fusing
I2t
A2s
100 % VRRM
reapplied
Maximum I2√t for fusing
I2√t
VF(TO)1
VF(TO)2
rt1
I2t for time tx = I2√t x √tx; 0.1 ≤ tx ≤ 10 ms, VRRM = 0 V
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ maximum
( I > π x IF(AV)), TJ maximum
A2√s
Low level of threshold voltage
High level of threshold voltage
Low level forward slope resistance
High level forward slope resistance
Maximum forward voltage drop
Maximum DC reverse current
RMS isolation voltage
V
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ maximum
( I > π x IF(AV)), TJ maximum
mΩ
rt2
5.2
5.0
VFM
TJ = 25 °C, IFM = 40 Apk - per single junction
TJ = 25 °C, per junction at rated VRRM
1.26
1.19
V
µA
V
IRRM
VINS
100
TJ = 25 °C, all terminal shorted; f = 50 Hz, t = 1 s
2700
THERMAL - MECHANICAL SPECIFICATIONS
VALUES
26MT 36MT
PARAMETER
SYMBOL
TEST CONDITIONS
UNITS
Maximum junction and storage
temperature range
TJ, TStg
RthJC
- 55 to 150
1.42
0.2
°C
Maximum thermal resistance,
junction to case
DC operation per bridge
(based on total power loss of bridge)
1.35
0.2
K/W
Maximum thermal resistance,
case to heatsink
RthCS
Mounting surface, smooth, flat and greased
Approximate weight
20
g
Mounting torque 10 %
Bridge to heatsink with screw M4
2.0
Nm
www.vishay.com
2
For technical questions, contact: ind-modules@vishay.com
Document Number: 93565
Revision: 03-Nov-08
26MT../36MT.. Series
Three Phase Bridge
(Power Modules), 25/35 A
Vishay High Power Products
160
140
120
100
80
1000
26MT.. Series
26MT.. Series
100
10
1
Per junction
+
-
TJ = 25 °C
120° (rect.)
~
TJ = 150 °C
60
0
0
1
5
10
15
20
25
30
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Total Output Current (A)
Instantaneous Forward Voltage (V)
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Forward Voltage Drop Characteristics
55
50
45
40
35
30
25
20
15
10
5
55
50
45
40
35
30
25
20
15
10
5
26MT.. Series
TJ = 150 °C
120° (rect.)
0
0
0
25
50
75
100
125
150
5
10
20
25
Total Output Current (A)
Maximum Allowable Ambient Temperature (°C)
Fig. 3 - Total Power Loss Characteristics
320
300
280
260
240
220
200
180
160
140
120
100
80
400
At any rated load condition and with
rated VRRM applied following surge.
Maximum non-repetitive surge current
versus pulse train duration.
360
320
280
240
200
160
120
80
Initial TJ = 150 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
Initial TJ = 150 °C
No voltage reapplied
Rated VRRM reapplied
26MT.. Series
26MT.. Series
0.01
10
100
0.1
1
Number of Equal Amplitude Half Cycle
Current Pulses (N)
Pulse Drain Duration (s)
Fig. 4 - Maximum Non-Repetitive Surge Current
Fig. 5 - Maximum Non-Repetitive Surge Current
Document Number: 93565
Revision: 03-Nov-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
3
26MT../36MT.. Series
Three Phase Bridge
(Power Modules), 25/35 A
Vishay High Power Products
150
1000
36MT.. Series
36MT.. Series
130
110
90
100
Per junction
TJ = 25 °C
TJ = 150 °C
120° (rect.)
10
+
-
~
70
50
1
0
5
10
15
20
25
30
35
40
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Total Output Current (A)
Instantaneous Forward Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
Fig. 6 - Current Ratings Characteristics
80
70
60
50
40
30
20
10
0
80
70
60
50
40
30
20
10
0
36MT.. Series
TJ = 150 °C
120° (rect.)
0
5
10
15
20
25
30
35
0
25
50
75
100
125
150
Total Output Current (A)
Maximum Allowable Ambient Temperature (°C)
Fig. 8 - Total Power Loss Characteristics
450
400
350
300
250
200
150
100
500
At any rated load condition and with
rated VRRM applied following surge.
Maximum non-repetitive surge current
versus pulse train duration.
450
400
350
300
250
200
150
100
Initial TJ = 150 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
Initial TJ = 150 °C
No voltage reapplied
Rated VRRM reapplied
36MT.. Series
36MT.. Series
0.01
1
10
100
0.1
1
Number of Equal Amplitude Half Cycle
Current Pulses (N)
Pulse Drain Duration (s)
Fig. 9 - Maximum Non-Repetitive Surge Current
Fig. 10 - Maximum Non-Repetitive Surge Current
www.vishay.com
4
For technical questions, contact: ind-modules@vishay.com
Document Number: 93565
Revision: 03-Nov-08
26MT../36MT.. Series
Three Phase Bridge
(Power Modules), 25/35 A
Vishay High Power Products
10
1
Steady state value:
RthJC = 1.42 K/W
(DC operation)
0.1
26MT.. Series
per bridge
0.01
0.001
.
.
0.001
0.01
0.1
1
10
100
Square Wave Pulse Duration (s)
Fig. 11 - Thermal Impedance ZthJC Characteristics
10
1
Steady state value:
RthJC = 1.35 K/W
(DC operation)
0.1
36MT.. Series
per bridge
0.01
0.001
.
.
0.001
0.01
0.1
1
10
100
Square Wave Pulse Duration (s)
Fig. 12 - Thermal Impedance ZthJC Characteristics
Document Number: 93565
Revision: 03-Nov-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
5
26MT../36MT.. Series
Three Phase Bridge
(Power Modules), 25/35 A
Vishay High Power Products
ORDERING INFORMATION TABLE
Device code
36
MT 160
1
2
3
26 = 25 A (average)
36 = 35 A (average)
1
2
3
-
-
-
Current rating code
Basic part number
Voltage code x 10 = VRRM
CIRCUIT CONFIGURATION
+
~
-
LINKS TO RELATED DOCUMENTS
http://www.vishay.com/doc?95251
Dimensions
www.vishay.com
6
For technical questions, contact: ind-modules@vishay.com
Document Number: 93565
Revision: 03-Nov-08
Outline Dimensions
Vishay Semiconductors
D-63
DIMENSIONS in millimeters (inches)
6.3 x 0.8 (0.25 x 0.03)
0.8 (0.31)
Suggested plugging force:
400 N maximum;
axially applied to fast on terminals
23 (0.90)
21 (0.83)
10
(0.39)
25.3 (0.99) MAX.
-
~
~
~
5.2
(0.20)
28.5
(1.12)
16
(0.63)
Not to scale
+
Document Number: 95251
Revision: 04-Nov-08
For technical questions, contact: indmodules@vishay.com
www.vishay.com
1
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Revision: 12-Mar-12
Document Number: 91000
1
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Vishay:
VS-26MT10 VS-26MT100 VS-26MT120 VS-26MT140 VS-26MT160 VS-26MT20 VS-26MT40 VS-26MT60 VS-
26MT80 VS-36MT10 VS-36MT100 VS-36MT120 VS-36MT140 VS-36MT160 VS-36MT40 VS-36MT60 VS-36MT80
VS-36MT20
相关型号:
VS-36MT20
Bridge Rectifier Diode, 3 Phase, 35A, 200V V(RRM), Silicon, ROHS COMPLIANT, D-63, 5 PINWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
VS-36MT60
Bridge Rectifier Diode, 3 Phase, 35A, 600V V(RRM), Silicon, ROHS COMPLIANT, D-63, 5 PINWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
VS-36MT80
Bridge Rectifier Diode, 3 Phase, 35A, 800V V(RRM), Silicon, ROHS COMPLIANT, D-63, 5 PINWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
VS-36SMB-IM2
Power/Signal Relay, POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.015A (COIL), 36VDC (COIL), 530mW (COIL), 10A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANTWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FUJITSU
VS-36SMB-NR-IM2
Power/Signal Relay, POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.014A (COIL), 36VDC (COIL), 530mW (COIL), 15A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANTWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FUJITSU
VS-36SMB-NR-SM2
Power/Signal Relay, POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.014A (COIL), 36VDC (COIL), 530mW (COIL), 15A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANTWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FUJITSU
VS-36SMB-NR-UC
Power/Signal Relay, POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.014A (COIL), 36VDC (COIL), 530mW (COIL), 15A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANTWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FUJITSU
VS-36SMBU-5-SM2
POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.015A (COIL), 36VDC (COIL), 530mW (COIL), 14A (CONTACT), 150VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANTWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FUJITSU
VS-36SMBU-E-SM2
POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.015A (COIL), 36VDC (COIL), 530mW (COIL), 14A (CONTACT), 150VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANTWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FUJITSU
VS-36SMBU-SM2
Power/Signal Relay, POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.015A (COIL), 36VDC (COIL), 530mW (COIL), 14A (CONTACT), 150VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANTWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FUJITSU
VS-36SMC-IM2
POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.015A (COIL), 36VDC (COIL), 530mW (COIL), 10A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANTWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FUJITSU
VS-36SMC-N-SM2
Power/Signal Relay, SPST, Momentary, 0.015A (Coil), 36VDC (Coil), 530mW (Coil), 10A (Contact), 24VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANTWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FUJITSU
©2020 ICPDF网 联系我们和版权申明