VHR30-2800T SERIES  
HIGH RELIABILITY COTS DC-DC CONVERTERS  
Models Available  
Input: 9 V to 80 V continuous, 100 V transient  
30 W, triple outputs of 3.3 V, 5 V, 12 V, 15 V  
-40 °C to 100 °C Operation  
1.0 DESCRIPTION  
1.1 FEATURES  
The VHR series of industrial grade DC-DC converters provides cost  
effective, high reliability solutions for use in defense, avionics and  
manufacturing industries. The VHR industrial grade products  
leverage decades of VPT's proven heritage in military and  
aerospace electronics.  
High Reliability at Low Cost  
30 Watts Output Power  
Three Independent Fully Isolated Outputs  
Wide Input Voltage Range: 9 to 80 Volts per MIL-STD-704 and  
MIL-STD-1275  
High Input Transient Voltage: 100 Volts for 1 sec per  
MIL-STD-1275  
Each Output can be configured as a Positive or Negative Output  
Zero Cross Regulation  
No Minimum Load Requirement  
Input Undervoltage Lockout  
Fixed Frequency  
VPT’s VHR30-2800T series is ideal for non flight-critical solutions in  
military, avionics, unmanned systems as well as manufacturing  
equipment and controls. A wide input voltage range which  
accommodates nominal 28 V inputs, low input and output ripple,  
fixed operating frequency and companion EMI filters simplify  
system design while ensuring operating success in the most rugged  
of environments.  
Output Soft Start  
Short Circuit Protection  
These converters are designed and manufactured in a facility  
certified to ISO9001, J-STD-001 and IPC-A-610.  
Magnetic Feedback, no Optoisolators  
Wide Temperature Range, -40 °C to 100 °C  
Internally Conformal Coated  
This product may incorporate one or more of the following U.S.  
patents:  
Standard Six Sided Non-Hermetic Rugged Metal Package  
1.2 COMPLIANCE  
5,784,266  
5,790,389  
5,963,438  
5,999,433  
6,005,780  
6,084,792  
6,118,673  
MIL-STD-1275  
MIL-STD-704  
Meets MIL-STD-461C-F and EN55022 when used with an  
appropriate VHR EMI Filter  
1.3 PACKAGING  
Low-profile: 1.885” x 1.325” x 0.400”  
Max weight: 50 g  
1.4 SIMILAR PRODUCTS AND ACCESSORIES  
DVTR 30 W triple output DC-DC Converter  
VPT30 30 W triple output COTS DC-DC Converter  
EMI filters, Thermal Pads, Front-End Modules and Accessories  
2.0  
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com  
1
VHR30-2800T SERIES DATASHEET  
2.0 DESCRIPTION  
2.1 BLOCK DIAGRAM  
Post  
Regulator  
Post  
Regulator  
UNDER  
VOLTAGE  
SHUTDOWN  
Post  
Regulator  
PRIMARY  
HOUSEKEEPING  
SUPPLY  
PWM  
CONTROL  
VOLTAGE  
AMPLIFIER  
2.2 CONNECTION DIAGRAM  
(Shown with optional VHRF3-28 EMI filter, recommended for input voltages > 13V, and optional negative output configuration.)  
2.0  
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com  
2
VHR30-2800T SERIES DATASHEET  
2.2 CONNECTION DIAGRAMS (CONTINUED)  
(Shown with optional VHRF10-28 EMI filter, recommended for input voltages < 13V, and optional stacked output configuration.)  
Inhibit Circuit (Shown with optional capacitor for turn-on delay)  
2.0  
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com  
3
VHR30-2800T SERIES DATASHEET  
3.0 SPECIFICATIONS  
3.1 ABSOLUTE MAXIMUM RATINGS  
Absolute Maximum Ratings  
Input Voltage (Continuous):  
Input Voltage (Transient, 1 sec):  
80 V  
100 V  
Operating Temperature (Full Load):  
Storage Temperature:  
Lead Solder Temperature (10 seconds):  
-40 °C to 100 °C  
-55° C to 125 °C  
300 °C  
3.2 PERFORMANCE SPECIFICATIONS  
Tcase = -40 °C to 100 °C, Vin = +28 V ± 5%, Full Load, Unless Otherwise Specified  
VHR30-2800T  
Parameter  
INPUT  
Conditions  
Min  
Typ  
Max  
Units  
4
Voltage  
9
-
28  
-
80  
V
V
Continuous  
3
100  
Transient, 1 sec  
INH < 1.5 V  
No Load  
Current  
-
-
1
90  
5
130  
mA  
mA  
5
20 Hz to 10 MHz  
-
9.8  
8
30  
-
90  
11  
mA  
V
Ripple Current  
Undervoltage Lockout  
Turn On  
3
-
8.9  
V
Turn Off  
OUTPUT STATIC  
2
0
-
-
30  
5
W
W
Power  
Load Fault Power Dissipation  
Short Circuit  
2
FUNCTION  
3
Output Inhibited  
Output Enabled  
0
9
-
1.5  
13  
V
V
Inhibit Pin Input  
3
11  
Inhibit Pin Open Circuit Voltage  
GENERAL  
5
77  
82  
-
%
Efficiency  
Switching Frequency  
Input  
Output  
500 V DC, Tcase = 25 °C  
100 V DC, Tcase = 25 °C  
400  
325  
100  
20  
500  
400  
-
-
-
550  
475  
-
-
50  
kHz  
kHz  
MΩ  
MΩ  
g
Isolation Input / Output / Case  
Isolation Output / Output  
Weight  
-
MTBF (MIL-HDBK-217F)  
GM @ Tcase = 55 ºC  
672  
kHr  
3.3 V Output  
5 V Output  
Parameter  
Conditions  
Min  
Typ  
Max  
Min  
Typ  
Max  
Units  
OUTPUT STATIC  
Voltage  
Tcase = 25 °C  
Tcase = -40 °C to 100 °C  
3.25  
3.21  
0
3.3  
3.3  
-
3.35  
3.38  
10  
4.92  
4.87  
0
5
5
-
5.08  
5.13  
15  
V
V
2
W
Power  
2
0
-
-
40  
2
3
0
-
-
40  
2
3
A
Current  
Ripple Voltage  
20 Hz to 10 MHz  
Vin = 9 V to 80 V  
No Load to Full Load  
100  
20  
100  
20  
mVpp  
mV  
mV  
5
-
-
Line Regulation  
Load Regulation  
-
3
30  
-
3
30  
OUTPUT DYNAMIC  
Load Step, Half to Full Load  
Output Transient  
-
-
140  
120  
280  
240  
-
-
100  
90  
200  
180  
mVpk  
µs  
1
Recovery  
3, 5  
Output Transient  
-
-
50  
50  
100  
100  
-
-
60  
50  
120  
100  
mVpk  
µs  
Line Step , Vin = 16 V to 40 V  
1
Recovery  
5
Delay  
-
-
14  
0
20  
15  
-
-
14  
0
20  
25  
ms  
Turn On , Vin = 0 to 28 V  
Overshoot  
mVpk  
GENERAL  
3
-
-
1000  
-
-
1000  
µF  
Capacitive Load  
1.  
2.  
3.  
4.  
5.  
Time for output voltage to settle to within 1% of its nominal value  
Derate linearly to 0 at 110 °C  
Verified by qualification testing  
Operation down to 9 V is possible after the input voltage is taken above 11 V to start the module  
Tested with a balanced full load of 10 W per each output  
2.0  
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com  
4
VHR30-2800T SERIES DATASHEET  
3.2 PERFORMANCE SPECIFICATIONS (CONTINUED)  
Tcase = -40 °C to 100 °C, Vin = +28 V ± 5%, Full Load, Unless Otherwise Specified  
12 V Output  
15 V Output  
Parameter  
Conditions  
Min  
Typ  
Max  
Min  
Typ  
Max  
Units  
OUTPUT STATIC  
Voltage  
Tcase = 25 °C  
Tcase = -40 °C to 100 °C  
11.82  
11.7  
12  
12  
12.18  
12.3  
14.77  
14.62  
15  
15  
15.23  
15.38  
V
V
2
0
-
15  
0
-
15  
W
Power  
2
0
-
-
40  
2
1.25  
100  
20  
0
-
-
40  
2
1
A
Current  
Ripple Voltage  
20 Hz to 10 MHz  
Vin = 9 V to 80 V  
No Load to Full Load  
100  
20  
mVpp  
mV  
mV  
5
-
-
Line Regulation  
Load Regulation  
-
3
30  
-
3
30  
OUTPUT DYNAMIC  
Load Step, Half to Full Load  
Output Transient  
-
-
120  
0
240  
100  
-
-
110  
0
220  
100  
mVpk  
µs  
1
Recovery  
3, 5  
Output Transient  
-
-
150  
50  
300  
100  
-
-
180  
50  
360  
100  
mVpk  
µs  
Line Step , Vin = 16 V to 40 V  
1
Recovery  
5
Delay  
-
-
14  
0
20  
50  
-
-
14  
0
20  
50  
ms  
Turn On , Vin = 0 to 28 V  
Overshoot  
mVpk  
GENERAL  
3
-
-
500  
-
-
500  
µF  
Capacitive Load  
1.  
2.  
3.  
4.  
5.  
Time for output voltage to settle to within 1% of its nominal value  
Derate linearly to 0 at 110 °C  
Verified by qualification testing  
Operation down to 9 V is possible after the input voltage is taken above 11 V to start the module  
Tested with a balanced full load of 10 W per each output  
2.0  
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com  
5
VHR30-2800T SERIES DATASHEET  
4.0 PERFORMANCE CURVES  
4.1 EFFICIENCY PERFORMANCE CURVES  
Tcase = 25 °C, Full Load, Unless Otherwise Specified  
4.1.1 VHR30-283R31212T Efficiency (%) vs. Output Power (W) 4.1.2 VHR30-2851515T Efficiency (%) vs. Output Power (W)  
2.0  
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com  
6
VHR30-2800T SERIES DATASHEET  
5.0 MECHANICAL OUTLINES AND PINOUT  
Standard Metal Package:  
1.885in 47.88mm MAX  
1.550in 39.37mm  
0.245in 0.015 6.22mm 0.38  
.400in 10.16mm MAX  
2X MOUNTING HOLE  
0.165in 4.19mm  
0.004  
+
0.125in  
0.003  
-
+
0.10  
0.08  
3.18mm  
BASEPLATE SURFACE  
-
10X SEAL  
0.600in 15.24mm  
4
3
2
1
0.083in 0.002  
2.10mm 0.05  
5
6
0.400in 10.16mm  
0.250in 6.35mm  
0.200in 5.08mm  
0.100in 2.54mm  
0in 0mm  
0.050in 1.27mm  
0.200in 5.08mm  
10X PIN  
0.039in 0.002  
1mm 0.05  
7
8
9
10  
0.350in 8.89mm  
0.375in 9.53mm  
1.  
2.  
3.  
4.  
Case temperature is measured on the center of the baseplate surface.  
Materials: Baseplate (Aluminum, conductive conversion coating); Cover (Nickel Plated); Pins (Copper, gold over nickel plating)  
Mounting holes are not threaded. Recommended fastener is 4-40  
This Package is not hermetic. VPT offers a wide range of hermetic products. Please contact VPT for details if hermetic products are required.  
Pin Function  
Pin Function  
1
2
3
4
5
INCOM  
INHIBIT  
CASE  
6
OUTRET1  
7
+VOUT2  
8
OUTRET2  
+VOUT3  
28V IN  
+VOUT1  
9
10  
OUTRET3  
2.0  
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com  
7
VHR30-2800T SERIES DATASHEET  
6.0 PACKAGE PIN DESCRIPTION  
Pin  
Function  
Description  
1
2
INCOM  
Input Return Connection.  
This is an open collector input. Logic Low = Disabled Output. Connect the inhibit pin to input common to disable the output.  
Unconnected, open collector or open drain = Enabled Output.  
INHIBIT  
CASE  
3
Case Connection.  
4
28VIN  
Positive Input Voltage Connection.  
Positive Output 1 Voltage Connection.  
Output Return 1 Connection.  
5
+VOUT1  
OUTRET1  
+VOUT2  
OUTRET2  
+VOUT3  
OUTRET3  
6
7
Positive Output 2 Voltage Connection.  
Output Return 2 Connection.  
8
9
Positive Output 3 Voltage Connection.  
Output Return 3 Connection.  
10  
7.0 ENVIRONMENTAL SCREENING  
Screening  
Condition  
Internal Visual  
IPC-A-610, Class 3  
Final Electrical  
External Visual  
100% at 25 °C  
Internal Procedure  
8.0 ORDERING INFORMATION  
VHR30-  
28  
5
15  
15  
T
1
2
3
4
5
6
(1)  
Product  
Series  
(2)  
(3)  
Output 1  
(4)  
Output 2  
(5)  
Output 3  
(6)  
Nominal Input  
Voltage  
Number of  
Outputs  
VHR30-  
28  
28 Volts  
3R3  
5
3.3 Volts  
5 Volts  
5
12  
15  
5 Volts  
12 Volts  
15 Volts  
12  
15  
12 Volts  
15 Volts  
T
Triple  
Please contact your sales representative or the VPT Inc. Sales Department for more information concerning additional  
environmental screening and testing, different input voltage, output voltage, power requirements, and source inspection.  
2.0  
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com  
8
VHR30-2800T SERIES DATASHEET  
9.0 CONTACT INFORMATION  
To request a quotation or place orders please contact your sales representative or the VPT, Inc. Sales Department at:  
Phone:  
Fax:  
(425) 353-3010  
(425) 353-4030  
E-mail:  
vptsales@vptpower.com  
All information contained in this datasheet is believed to be accurate, however, no responsibility is assumed for possible errors or  
omissions. The products or specifications contained herein are subject to change without notice. VPT, its logo and tagline are  
registered trademarks in the U.S. Patent and Trademark Office.  
10.0 ADDITIONAL INFORMATION  
Visit the VPT website for additional technical resources, including:  
Product Literature  
Application Notes and White Papers  
Technical Video Labs  
Additional Products For Avionics/Military,  
Hi-Temp, Hi-Rel COTS, and Space Applications  
2.0  
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com  
9

相关型号:

VHR30-283R31215T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-283R31512T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-283R31515T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-283R3512T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-283R3515T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-283R3S

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-2851212T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-2851215T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-2851512T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-2851515T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-285512T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT

VHR30-285515T

HIGH RELIABILITY COTS DC-DC CONVERTERS
VPT