ILPA100VU-S081ST [Vitec]
100W Water-Proof Constant Voltage LED Driver;型号: | ILPA100VU-S081ST |
厂家: | Vitec Power |
描述: | 100W Water-Proof Constant Voltage LED Driver |
文件: | 总2页 (文件大小:288K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ILPA100VU SERIES
100W Water-Proof Constant Voltage LED Driver
–
–
–
–
–
–
–
Wide Input Voltage 90 to 305VAC, 47 to 63Hz
Constant Output Voltage Available From 12VDC Thru 105VDC
Over Voltage, Over Current, Short Circuit, Lighting, and Over Temperature Protection
High Efficiency (up to 93%)
Active Power Factor Correction (PFC) (99% typical)
IP67 Waterproof Rating, Metal Housing
Comply with UL8750 & EN61347 Safety Regulation (Pending)
3 Year Warranty
Approvals:
Single Output
Max.
Efficiency
Over Voltage Protection
Min / Typ / Max
14V / 15V / 16V
27V / 30V / 34V
40V / 47V / 50V
47V / 52V / 57V
54V / 59V / 63V
60V / 68V / 75V
91V / 95V / 100V
120V / 125V / 140V
Max.
Output Power
100W
Part Number
Output Voltage
Output Current (220VAC, Full Load)
ILPA100VU-S012ST
ILPA100VU-S024ST
ILPA100VU-S036ST
ILPA100VU-S042ST
ILPA100VU-S048ST
ILPA100VU-S054ST
ILPA100VU-S081ST
ILPA100VU-S105ST
12 VDC
24 VDC
36 VDC
42 VDC
48 VDC
54 VDC
81 VDC
105 VDC
8.33 A
4.05A
2.75 A
2.25 A
1.95 A
1.75 A
1.23 A
0.95 A
91%
93%
93%
93%
92%
93%
93%
93%
100W
100W
100W
100W
100W
100W
100W
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Power Factor Correction
Efficiency
Test Conditions
Min.
90
47
Typ.
Max.
305
63
100
1.20
0.60
65
Unit
VAC
Hz
W
A
A
A
%
%
Operating Voltage
Vin=90 to 264VAC
0
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Vin=110VAC
99
96
Vin=220VAC
Io=Full Load, Vin=230VAC
No Load, VIn=230VAC
Io=Full Load
93
1.5
1
%
W
%
No-Load Power Consumption
Line Regulation
Load Regulation
Vin=230VAC
2
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
Over Voltage Protection
110
Over Current Protection
Over Temperature Protection
135
110
180
% Io
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
When power on or off
Io=Full Load, Vin=100VAC
10
3
%
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
uF electrolytic capacitor.
Ripple & Noise (Peak to Peak)
2
% Vo
Conditions
Parameter
Operating Temperature
Test Conditions
Min.
-35
Typ.
Max.
70
Unit
°C
Storage Temperature
-40
85
°C
Relative Humidity
5
95
%
Operation temperature at 25°C, calculated per MIL-HDBK-217F
Life Time at 25°C ambient temperature
No output power derating from -35°C to 60°C
0.439M
0.193M
Hours
Hours
Approvals and Compliance
Parameter
Standards
EMI
EN55015
EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-1-1, EN61547
EMS
UL8750 Compliant to UL1310 Class 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2
No.250.0, EN61347-1,EN61347-2-13
IP67 Rating
Safety UL/c-UL, T-mark, CE
Waterproof
Mechanical
Parameter
Specification
Dimension, Net Weight
184x67.5x37mm (7.24x2.66x1.46 inches), 950g approx.
650mm, Black(ACL), White(ACN), Green(GND)
220mm, Red(V+), Black(V-)
Input Electric Wire
Output Electric Wire
相关型号:
©2020 ICPDF网 联系我们和版权申明